С помощью ESPhome и устройства pzem-004t v3 можно сделать мониторинг электропотребления дома или отдельных устройств для Home Assistant.
s.click.aliexpress.com/e/_Dk0... - pzem-004t v3 по прекрасной цене
s.click.aliexpress.com/e/_DET... Tuya Smart ZigBee Energy Meter Single Phase 80A
00:40 - pzem-004T v 3.0 общая информация
02:20 - подавать 5В или 3,3В на pzem-004t?
04:00 - осторожно, 220В
05:40 - характеристики pzem-004T v 3.0
09:42 - подключение
10:58 - ESPHome
17:16 - команда на сброс
19:30 - полевые испытания стенда
26:20 - немного о ценах
Часть кода:
uart:
id: energomonitor_uart
rx_pin: D1
tx_pin: D2
baud_rate: 9600
sensor:
- platform: pzemac
current:
name: "220V Current"
voltage:
name: "220V Voltage"
energy:
name: "220V Energy"
power:
name: "220V Power"
id: power_monitor
frequency:
name: "220V Frequency"
power_factor:
name: "220V Power Factor"
update_interval: 1s
address: 1
- platform: total_daily_energy
name: "220V Total Daily Energy"
power_id: power_monitor
filters:
- multiply: 0.001
accuracy_decimals: 2
unit_of_measurement: kW
icon: mdi:counter
- platform: integration
name: "220V Energy Meter"
sensor: power_monitor
time_unit: h
filters:
Multiplication factor from W to kW is 0.001
- lambda: return x * (0.001);
unit_of_measurement: kWh
icon: mdi:counter
restore: true
switch:
- platform: uart
uart_id: energomonitor_uart
name: "220V Energy Reset"
data: [0x01, 0x42, 0x80, 0x11]

time:
- platform: homeassistant
id: hass_time

Опубликовано:

 

4 май 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 185   
@user-zv5os3gi5q
@user-zv5os3gi5q 3 года назад
Большое Вам спасибо за Ваши видео. Все очень доходчиво и понятно. Желаю удачи и успехов!
@pharaon1963
@pharaon1963 2 года назад
Спасибо за работу, все интересно. Хочу себе тоже такую штуковину сделать. Лайк и подписка:)
@awcfunclub
@awcfunclub 3 года назад
Шикарно! Очень доходчиво!
@user-ij6ts4wc7t
@user-ij6ts4wc7t 2 года назад
Отлично! Настолько все разжевано, что даже шансов ковер спалить не осталось!😄
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Шансы спалить что-то есть всегда, техника безопасности превыше всего!
@EvgenMo1111
@EvgenMo1111 2 года назад
2 штуки прикрутил, работает
@darkbaton
@darkbaton Год назад
как тебе это удалось? ,я уже неделю сижу по ночам и не смог разгадать секрет как подключить более одного устройства, и диоды пробовал, и стоп бит менял, и RX резистором подтягивал и baud_rate менял, итог 1- 1 устройство работает, но как только ты подключаешь линию данных от второго устройста шина перестает работать Modbus CRC Check failed! C071!=00
@EvgenMo1111
@EvgenMo1111 Год назад
@@darkbaton я перепрошил одну из pzem в проге PZEM_Master_Modbus, получил разные адреса устройств
@rbland
@rbland 2 года назад
Good detailed video. You would get a lot of views if it was in English 🙂
@tomaspucalik3850
@tomaspucalik3850 3 года назад
Děkuji vše funguje
@Symbol_great
@Symbol_great 3 года назад
Спасибо, реально интересен Ваш опыт. Я так и не понял почему одни 5в подключают, а другие 3.3, но только с 3.3 есп заработал с экранчиком 1602 и переходником IIC/I2C без подсветки за 2 бакса+. Только собрал такой на д1 мини, но на тасмоте. Как мне кажется, всё ещё проще. Подсоединил и прошил в 2 клика без особых настроек тасмоту (если не считать настройку сети вайфай и м2т сервера через вебморду) и все залетела в НА само через интеграцию Tasmota (18 объектов отключаемых). Как я понял, нужно собрать свою версию тасмоты если использовать дисплей.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Я сначала тоже думал с дисплеем делать, но зная себя, в этот дисплей я буду заглядывать раз в 2 года. а в ESPhome прошивать тоже все это довольно легко и просто, но я попытался вытащить почти все, что можно с этого модуля.
@Asmcavr
@Asmcavr 3 года назад
Для esp8266 предельное напряжение 3.6v , я хз какой кретин их в 5 вольт сует
@nikolatesla3416
@nikolatesla3416 2 года назад
@@Asmcavr то что там на самой плате контроллера есть конвертор напряжения вам ничего не говорит?
@Asmcavr
@Asmcavr 2 года назад
@@nikolatesla3416 не на всех платах есть понижайка.
@isayev007
@isayev007 8 месяцев назад
Дякую за контент! ;)
@Symbol_great
@Symbol_great 3 года назад
Д1 мини стоит 2$, просто вы выбрали на видео про версию, она дороже. только нашел Д1 мини на Али за 1.86 $ с бесплатной доставкой,продажи под 2 тыщи и 4.9 рейтинга. Зарядник можно использовать от старого моб. Без дисплея использовал корпус JG4-01 (Габаритные размеры составляют: по длине 37мм, по ширине 88мм и по высоте 59мм). Пришлось сделать вырез и вынести винтовую гребунку на крышку для компактности. Цена копейки, 35 грн не считая доставки.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
И точно на видео версия 3.0, не досмотрел я. За наводку на корпус буду благодарен, а то алиэкспресс ничего не показывает по запросу JG4-01.
@Symbol_great
@Symbol_great 3 года назад
@@BootuzDinamontuz KLS24-JG4-01 тут брал разные для тестов и издевательства www.kosmodrom.com.ua/el.php?name=JG4-01 ПДФ чертеж www.kosmodrom.com.ua/pdf/JG4-01.pdf Немного защёлка по середине мешали
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
@@Symbol_great , о, Харьков. А я олень на али ищу, а тут прямо под боком. Спасибо за наводку.
@user-gu4rh2om5l
@user-gu4rh2om5l 2 года назад
Спасибо, очень все отлично и понятно!!!!! Пожалуйста покажите ваши поделки реализованные в корпусе.!!!! Если таковое случилось.
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Реализация проекта будет аж через полгода, не ранее. Пока только тестовый вариант.
@alexandrshutko982
@alexandrshutko982 4 месяца назад
С килоомным резистором на самом деле все просто. Да без него на 3.3в работает. СЕЙЧАС работает на новом железе. Но ток на оптопаре получается на пределе ее чувствительности. Оптопары деградируют. Деградирует в ней и светодиод и фотоэлемент и сама среда между ними (если есть). В итоге через некоторое время связь с pzem может пропасть. Вот чтобы такого не допустить и уменьшают килоомный токоограничивающий резистор до 500ом путем подключения к уже имеющемуся килоомному параллельно еще одного.
@asupsp700
@asupsp700 4 месяца назад
Поддерживаю. У меня тоже работает на 1K, но на будущее поставил 510 Ом.
@silentage6310
@silentage6310 Месяц назад
так оно же наоброт, уменьшая напряжение ток увеличиваете и сгорит быстрее. по логике уменьшают сопротивление чтобы на меньшем напряжении (3.3 вместо 5) они горели ярче...
@alexandrshutko982
@alexandrshutko982 Месяц назад
@@silentage6310 это не так работает :-) Закон Ома вам в помощь.
@alexandrshutko982
@alexandrshutko982 Месяц назад
@@silentage6310 Нет. Это так не работает. Закон Ома - ток равен напряжение разделить на сопротивление. Уменьшаем напряжение - уменьшаем ток. Вы наверное путаете с импульсными источниками питания, у которых при понижении напряжения действительно повышается потребляемый ток. Но там сопротивление цепи питания считанные омы и оно не взрывается/сгорает только потому, что эта цепь включается на короткое время с частотой сотни килогерц умным контроллером.
@KenIdo
@KenIdo Год назад
Как подключить pzem-004t, находящийся в другой локальной сети (подключенной к интернет) к hass? Хотя бы в какую сторону думать?
@user-hf6iv9rs6x
@user-hf6iv9rs6x 2 года назад
Вопрос автору канала: не подскажете ли, как модернизировать библиотеку для PZEM-004t, чтобы ограничить количество попыток чтения микроконтроллером. Сейчас при пропадании напряжения сети микроконтроллер виснет при попытке чтения данных из PZEM-004t. Энергомонитор не может ответить микроконтроллеру и микроконтроллер зависает в подпрограмме чтения данных. Как этого избежать?
@e2nomy
@e2nomy 2 года назад
Glad you copied my code :) .... Spacibo :)
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Where? Show me.
@inhibitz
@inhibitz 2 года назад
на esp32 есть один минус (в частности на tasmota): пропадают данные за текущий день в случае сброса по питанию (ну например скачок в сети по напряжению), в вашем случае то как ?
@neomatic3988
@neomatic3988 2 года назад
Это в большинстве так если накопленное значение обрабатывает модуль а не хоум ассистент.
@System32mm
@System32mm Год назад
total_daily_energy обнулялся по UTC 00:00, меня это страшно бесило. Хотя с 0 до 2 почти нет нагрузки. Но мой внутренний перфекционист был в ярости.... Нашел решение!!! 🙂 time: - platform: sntp id: sntp_time timezone: UTC-02:00 Примечание: -02:00 на самом деле означает смещение +2 часов относительно UTC. Инвертированый знак...
@user-jj6oo7bw9u
@user-jj6oo7bw9u Год назад
А можно ли на micropython то же самое реализовать?
@ilyaroskov2003
@ilyaroskov2003 2 года назад
Добрый день, когда вы компилировали файл. Время на видео 19:08, в строке TX Pin: GPIO4 RX Pin: GPIO5. А мы используем порты wemos 1 и 2. Это верно?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Крайне не рекомендую использовать пины, которые как последовательный порт работают. Лог не будете видеть, а иногда это нужно. Пробуйте другие пины.
@VasiliyK72
@VasiliyK72 Год назад
@@BootuzDinamontuz Добрый вечер! По поводу смены пинов UART . А что можно UART организовать на любых пинах? А почему логи не работают на последовательном порту?
@konstantinekostromin5917
@konstantinekostromin5917 Год назад
У меня посему то не правильно показания 220V Energy Meter 2 минуты назад 1 882,4877 kWh
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Если у вас много устройств pzem подключено к одному и тому же ведущему, то нужно сначала каждому устройство присвоить адрес. Процедура описана в даташите в пункте 2.4 Read and modify the slave parameters. Максимум допустимо 247 устройств.
@shserg000
@shserg000 3 года назад
А Вы можете подсказать как организовать начало отчёта устройства с показаний счётчика?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
@Сергей Шуплецов а там смещение добавить нужно. - platform: pzem004t # ... filters: - offset: 2.0
@shserg000
@shserg000 3 года назад
@@BootuzDinamontuz т.е. в смещении указать непосредственно что раньше счетчик насчитал я правильно понимаю?
@shserg000
@shserg000 3 года назад
В offset 32000.0 ? Верно?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
@@shserg000 , сколько нужно, столько и пишите.
@awcfunclub
@awcfunclub 3 года назад
Не мешало бы yaml где то публиковать. А то народ с экрана плохо копирует и будет куча комментариев: а у меня не работает
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
О, точно. а тоя сразу и не подумал об этом. Прям в подписи к видео и написал.
@shserg000
@shserg000 2 года назад
Доброго времени суток! Ситуация такая работало и работает отлично с Вашим кодом без проблем не так уж давно заметил одну интересную вещь суточное потребление сбрасывалось как положено в 24:00 а сейчас перескочила на 14:00. Проверил все устройства с кем он может синхронизироваться, везде все соответствует реальному времени. Почему сброс происходит в 14:00 непонятно. Подскажите как этот недуг побороть
@neomatic3988
@neomatic3988 2 года назад
Если не разобрались - сброс происходит средствами вемоса. Для этого у него поднимается клиент нтп. Это могут быть какие то неверные настройки часовых поясов. Правильнее делать это на стороне хом асистанса. И подсчет и часовой пояс будут верными. Через утилити метр (коммунальные счетчики)
@ivahov555
@ivahov555 3 года назад
Можно уточнить, почему если ESP32 используется, то надо подавать 5в?
@ivahov555
@ivahov555 3 года назад
Напряжение питания и уровень TTL могут отличатся ведь
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Если ESP32 то можно подавать 5В. Там логика толерантна к 5В. А в 8266 не толерантна.
@anti-spy
@anti-spy 2 года назад
Как программно убрать не корректные значения во время запуска? Хочу считать потребление не только в квт, но и в деньгах. А при таком запуске, сразу 7 евро накидывает...
@edvaledval7699
@edvaledval7699 2 года назад
Приветствую. В квартиру приходит 3 фазы. На неделе получу 1 pzem. Возник вопрос. На схеме к pzem кольцо накинуто на N.Если я тоже накину кольцо на N , будут передаваться данные ? Если нет возник другой вопрос, как запитывать pzem. от фазы на которую накинуто кольцо ? Спасибо
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
На фазный, от фазы.
@edvaledval7699
@edvaledval7699 2 года назад
@@BootuzDinamontuz Спасибо
@ulinkot
@ulinkot 2 года назад
логика как на esp32 так и на esp8266 3.3v. Многие говорят, что пины esp толерантны к 5v но это неправильно.. Вообще данный миф про толерантность 5v(на esp8266) возник еще тогда когда esp32 даже не существовало. По поводу UART подключения данного модуля, в любом случае на модуль подается 5v и пины из UART подрубается или через транзисторную сборку или резисторную, а вообще можно тупо купить плату логики конвертера (тупо мини сборка из полевиков) для согласования 3.3 с 5v в обе стороны. Зачем подрубать 5v к модулю когда есть 3.3v? Скорее в данной ситуации (тупо читаем данные с модуля) незачем, но вы получаете больше одностороннюю UART связь (принимать модуль данные может сбойно из-за не открытия 5v уровня, конечно при условии что вы пишите в него данные...) Гальваническая развязка с оптронами там нужна по причине не сгорания, а разности потенциалов платы... На этой плате вместо нормального гальванически изолированного блока питания стоит смесь из конденсатора стаба и еще чегото.. коснись ее и будет худо.. Вообще бы в данном видео осветить вопрос переделки блока питания на нормальный.. esp8266 в пике может и 320mA хавать. На esp8266 два аппаратных UART, один как вы уже заметили "логер" (тупо uart подрубили к ch340), а второй UART можно через туже arduino переключать и работать с ним (а по видео кажись вы использовали вообще программный uart что нутакое..) нутакое...
@ssovych
@ssovych 2 года назад
А можно для 3-х фаз просто повесить 3 PZEMки на разные пины ESP? Например PZEM1: D1,D2; PZEM2: D3,D4; PZEM3: D5,D6?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Можно.
@ssovych
@ssovych 2 года назад
@@BootuzDinamontuz А что в таком случае писать в конфиге uart?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
ID прописывать. Типа такого uart: id: uart_bus tx_pin: D0 rx_pin: D1 baud_rate: 9600
@ssovych
@ssovych 2 года назад
@@BootuzDinamontuz Спасибо, я так и думал. Накидал черновик, проверить пока не могу, жду PZEMки с Алиэкспреса. uart: - id: uart_1 rx_pin: D1 tx_pin: D2 baud_rate: 9600 - id: uart_2 rx_pin: D3 tx_pin: D4 baud_rate: 9600 - id: uart_3 rx_pin: D5 tx_pin: D6 baud_rate: 9600 modbus: sensor: - platform: pzemac current: name: "PZEM-004T P1 Current" voltage: name: "PZEM-004T P1 Voltage" energy: name: "PZEM-004T P1 Energy" power: name: "PZEM-004T P1 Power" id: power_monitor1 frequency: name: "PZEM-004T P1 Frequency" power_factor: name: "PZEM-004T P1 Power Factor" update_interval: 30s modbus_id: uart_1 - platform: pzemac current: name: "PZEM-004T P2 Current" voltage: name: "PZEM-004T P2 Voltage" energy: name: "PZEM-004T P2 Energy" power: name: "PZEM-004T P2 Power" id: power_monitor2 frequency: name: "PZEM-004T P2 Frequency" power_factor: name: "PZEM-004T P2 Power Factor" update_interval: 30s modbus_id: uart_2 - platform: pzemac current: name: "PZEM-004T P3 Current" voltage: name: "PZEM-004T P3 Voltage" energy: name: "PZEM-004T P3 Energy" power: name: "PZEM-004T P3 Power" id: power_monitor3 frequency: name: "PZEM-004T P3 Frequency" power_factor: name: "PZEM-004T P3 Power Factor" update_interval: 30s modbus_id: uart_3
@RocketFox007
@RocketFox007 2 года назад
А почему на один UART все не повесить?
@dilkins_fpv
@dilkins_fpv 2 года назад
у меня к тебе вопросс, если взять кольцо и нарастить провод в несколько метров, скажется ли это на показаниях?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Не должно, но смысл? питание psem должно идти от того же источника, на котором измеряется ток. Так что нужно пземку разместить поближе, а уже от нее провода с данными вывести подальше.
@user-pe5tt6ro3i
@user-pe5tt6ro3i 2 года назад
Есть ли возможность без HA как то считывать потребление? Просто со смартфона, например через вебморду esp. Есть ли такие прошивки?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Вполне, ищете в гугле Pzem-004 V3 + esp32. И без проблем найдете скетч.
@102diy
@102diy 2 года назад
Tasmota
@pharaon1963
@pharaon1963 2 года назад
Есть видео поподробнее с графиками напряжения? Создается ли архив с данными ?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Архив с данными создается в Home Assistant.
@pharaon1963
@pharaon1963 2 года назад
@@BootuzDinamontuz Спасибо
@mykhailoromanenko705
@mykhailoromanenko705 2 месяца назад
а якщо замінити стаб 7133(30мА) на 7533(100мА) або 7333(250мА)? тоді можна прибрати доп. БЖ? ..... хочу спробувати, якщо не вб'є, напишу результат ))
@mykhailoromanenko705
@mykhailoromanenko705 2 месяца назад
я живий :). все вийшло. використав HT7333-1. Працює норм. АЛЕ. Просідає напруга до стабілізатора при підєднанні ESP. А переробляти всю схему нема бажання. Такі справи, використовуємо окремий AC-DC для ESP.
@id3388871
@id3388871 3 года назад
вопрос сохранения накапливаемого значения энергии при выключении питания esp8266
@slavak7815
@slavak7815 3 года назад
Home Assistant пишет в базу данных
@Asmcavr
@Asmcavr 3 года назад
Никаких проблем- читайте документацию на ESPHOME.
@ivahov555
@ivahov555 3 года назад
PZEM у себя хранит данные
@joramotorsportteam3277
@joramotorsportteam3277 2 года назад
12:30 A kak s 3Faznoj setju izmerenija???
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ZbLrY648QoM.html адреса прописать уникальные надо и 3 устройства.
@AndreyShalobasov
@AndreyShalobasov 2 года назад
Столкнулся с нелогичными показаниям от PZEM 004t v3. Один модуль у меня стоит в щитке в бойлерной в доме и мониторит только линию с кондиционером. Больше на линии ничего нет. Показания через Wemos идут в home assistant. На днях поставил сборку из трех модулей PZEM в основной щит, в гараже, те ближе уже к трубостойке. Соответственно прошил разные адреса на модулях Трансформаторы повесил отдельно на каждую фразу. Так вот, показания силы тока и мощности на той фазе, где кондиционер, не соответствуют показаниям модуля, который отдельно измеряет линию с кондиционером. Кондей потребляет сейчас около 1квч. Мощность примерно 1кВт. Но если его включить или выключить, то на модуле, который измеряет общую нагрузку на фазе изменение существенно больше, чем 1квт. Почти в 2 раза. С силой тока такая же история. Кондей включен - на фазе 11А, на кондее 7А Кондей выключен - на фазе 1,7А, на кондее 1А. На счёт мощности, я понял в чем проблема. Мой Косяк подключения. Я все три модуля запитал от одной фазы. Соответственно при расчёте мощности он использует неверные данные по напряжению и по коэффициенту мощности. Но ведь силу тока он измеряет напрямую с провода. Верно? Или я что-то не понимаю в логике? Буду признателен, если кто-то прокомментирует историю с разными показаниями по силе тока. Спасибо.
@michaelfoma262
@michaelfoma262 2 года назад
Привет ! можеш скинуть пример своего скетча ?
@AndreyShalobasov
@AndreyShalobasov 2 года назад
@@michaelfoma262 для трёх фаз интересует?
@michaelfoma262
@michaelfoma262 2 года назад
Да!
@AndreyShalobasov
@AndreyShalobasov 2 года назад
@@michaelfoma262 esphome: name: pzem-3ph platform: ESP8266 board: nodemcuv2 # Enable logging logger: # Enable Home Assistant API api: ota: password: "xxx" wifi: ssid: "xxxx" password: "xxxx" # Enable fallback hotspot (captive portal) in case wifi connection fails ap: ssid: "Pzem-3Ph Fallback Hotspot" password: "xxxx" captive_portal: uart: id: ubus rx_pin: D4 tx_pin: D3 baud_rate: 9600 stop_bits: 1 modbus: id: mbus uart_id: ubus sensor: - platform: pzemac address: 1 modbus_id: mbus current: name: "L1 current" voltage: name: "L1 voltage" energy: name: "L1 energy" power: name: "L1 power" frequency: name: "L1 frequency" power_factor: name: "L1 power factor" update_interval: 10s - platform: pzemac address: 2 modbus_id: mbus current: name: "L2 current" voltage: name: "L2 voltage" energy: name: "L2 energy" power: name: "L2 power" frequency: name: "L2 frequency" power_factor: name: "L2 power factor" update_interval: 10s - platform: pzemac address: 3 modbus_id: mbus current: name: "L3 current" voltage: name: "L3 voltage" energy: name: "L3 energy" power: name: "L3 power" frequency: name: "L3 frequency" power_factor: name: "L3 power factor" update_interval: 10s
@foma72ify
@foma72ify 2 года назад
@@AndreyShalobasov Спасибо вот мой пример: uart: id: energy_uart rx_pin: 16 tx_pin: 17 baud_rate: 9600 stop_bits: 2 modbus: id: menergy_uart uart_id: energy_uart sensor : - platform: pzemac address: 1 modbus_id: menergy_uart current: name: "Current1" voltage: name: "Voltage1" energy: name: "Energy1" power: name: "Power1" id: power_monitor1 frequency: name: "Frequency1" power_factor: name: "Power Factor1" update_interval: 10s - platform: pzemac address: 2 modbus_id: menergy_uart current: name: "Current2" voltage: name: "Voltage 2" energy: name: "Energy2" power: name: "Power2" id: power_monitor2 frequency: name: "Frequency2" power_factor: name: "Power Factor2" update_interval: 10s - platform: pzemac address: 3 modbus_id: menergy_uart current: name: "Current3" voltage: name: "Voltage3" energy: name: "Energy3" power: name: "Power3" id: power_monitor3 frequency: name: "Frequency3" power_factor: name: "Power Factor3" update_interval: 10s - platform: total_daily_energy name: "Total Daily Energy1" power_id: power_monitor1 filters: - multiply: 0.001 accuracy_decimals: 2 unit_of_measurement: kW icon: mdi:counter - platform: total_daily_energy name: "Total Daily Energy2" power_id: power_monitor2 filters: - multiply: 0.001 accuracy_decimals: 2 unit_of_measurement: kW icon: mdi:counter - platform: total_daily_energy name: "Total Daily Energy3" power_id: power_monitor3 filters: - multiply: 0.001 accuracy_decimals: 2 unit_of_measurement: kW icon: mdi:counter - platform: integration name: "Energy Meter1" sensor: power_monitor1 time_unit: h filters: # Multiplication factor from W to kW is 0.001 - lambda: return x * (0.001); unit_of_measurement: kWh icon: mdi:counter restore: true - platform: integration name: "Energy Meter2" sensor: power_monitor2 time_unit: h filters: # Multiplication factor from W to kW is 0.001 - lambda: return x * (0.001); unit_of_measurement: kWh icon: mdi:counter restore: true - platform: integration name: "Energy Meter3" sensor: power_monitor3 time_unit: h filters: # Multiplication factor from W to kW is 0.001 - lambda: return x * (0.001); unit_of_measurement: kWh icon: mdi:counter restore: true switch: - platform: uart uart_id: energy_uart name: "Energy Reset1" data: [0x01, 0x42, 0x80, 0x11] - platform: uart uart_id: energy_uart name: "Energy Reset2" data: [0x02, 0x42, 0x80, 0xE1] - platform: uart uart_id: energy_uart name: "Energy Reset3" data: [0x03, 0x42, 0x81, 0x71] time: - platform: homeassistant id: hass_time
@user-mu6yn5ce8w
@user-mu6yn5ce8w 2 года назад
А дайте пожалуйста прямую ссылку на готовое устройство zigbee
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
cutt.ly/Zbm0Txe - готовое решение для Zigbee
@user-mu6yn5ce8w
@user-mu6yn5ce8w 2 года назад
@@BootuzDinamontuz а можно ссылку не через летишопс? Так не открывается, ругается на россиян :(
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
aliexpress.ru/item/1005002409588154.html
@rzh84
@rzh84 3 года назад
Как это 10 pzemок? Насколько я знаю у pzem только три адреса: 1 , 2 и 3.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
По умолчанию адрес всегда 0х01. Но можно установить от 0х01 до 0хF7.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ZbLrY648QoM.html вот тут рассказываю как работать с адресами.
@darkbaton
@darkbaton Год назад
Спасибо за видео! все по делу как всегда! так держать! подключил одну все работает, не нарадуюсь но вот решил подключить еще одну и возникли траблы которые я так и не смог решить. я уже неделю сижу по ночам и не смог разгадать секрет как подключить более одного устройства, и диоды пробовал, и стоп бит менял, и RX резистором подтягивал и baud_rate менял, итог всегда один- 1 устройство работает, но как только ты подключаешь линию данных от второго устройства шина перестает работать и пишет в логах ошибку. Modbus CRC Check failed! C071!=00 Может у тебя есть готовое решение этой проблемы? форумы особо не помогли с решением.
@BootuzDinamontuz
@BootuzDinamontuz Год назад
Это во второй серии. Там нужно адрес назначить другой. И можно хоть сотню (привираю малехо) соединять в кучу.
@darkbaton
@darkbaton Год назад
@@BootuzDinamontuz все сделал по шагам урока, ничего у меня не получилось Слушай а можешь подсказать как в скетче прописать несколько UART? нашел несколко примеров на гит хабе, но и эта инфа не помогла, при проверке выдает ошибку "слишком много UART, выберите один" основной конфиг: uart: - id: uart_0 rx_pin: 12 tx_pin: 13 baud_rate: 9600 # id: energomonitor_uart0_1 sensor: - platform: pzemac current: name: "220V Current 1" voltage: name: "220V Voltage 1" update_interval: 1s address: 0x01 - platform: pzemac current: name: "220V Current 2" voltage: name: "220V Voltage 2" update_interval: 1s address: 0x02 конфиг под 2 uart: uart: - id: uart_0 rx_pin: 12 tx_pin: 13 baud_rate: 9600 # id: energomonitor_uart0_1 - id: uart_1 rx_pin: 32 tx_pin: 33 baud_rate: 9600 работаю с платой NodeMCU32S
@BootuzDinamontuz
@BootuzDinamontuz Год назад
@@darkbaton а прописать адреса, разные в Пземки не получилось? Серию следующую не смотрели?
@darkbaton
@darkbaton Год назад
@@BootuzDinamontuz следующую серию смотрел, но она мне особо не помогла. Делал все как в уроке, не совсем понятен момент по этим самым адресам и где они прописываются. а скомпилировал и записал все в ЕСП32, подключил плату, проврил, светодиод мигает, подал питание на ПЗЕМКу, перезалил новый скетч в ЕСП32, Посомтрел в Мониторинге порта, там идут каракули какие то, Далее взял ЕСП и перезалил в нее конфиг ЕСПХОУМ. По итогу опять та же песня. Сегодня повторю все операции сначала.
@darkbaton
@darkbaton Год назад
@@BootuzDinamontuz По итогу решил проблему прописыванием адресов с помощью CP2102 через программу PZEM Modbus Master. Кстати все корректно заработало без подтягивающего резистора и диодов, при условии использования вышеперечисленных компонентов невозможно было по воздуху обновить конфиг платы.
@Tsykhan
@Tsykhan 3 года назад
Я так розумію що КЗ на шунті - не є нормальним явищем? У мене між двома контактами трансформатора і одним контактом живлення модуля КЗ. В результаті чого на виході отримую нулі. Паралельно транса увімкнено резистор з 0 опором.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Шунт і токовий трансформатор це абсолютно різні речі. Шунт використовується на постійному струмі, трансформатор на змінному. У вас яка pzem?
@Tsykhan
@Tsykhan 3 года назад
@@BootuzDinamontuz я про внутрішній шунт модуля, який там має бути на навантаження 10А. У мене V3.0. Щойно перевірив на Arduino - те саме. В моніторі порту - помилки.
@Tsykhan
@Tsykhan 3 года назад
Роздивився там між контактами резюк R500 схоже він і заставляє прозвонку верещати
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Модуль для вимірювання змінного струму?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
На модулі написано що він на 10А?
@Koliadjun
@Koliadjun 3 года назад
Зробив собі майже так само, але на esp 01. GPIO1 та GPIO3. Але кнопка скидання не працює. Не розумію чому. Пробував різні адреси різні чек суми не допомогає. Може хто вкурсі чому так. Прошивка Esphome.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Код в студію. Треба чітко знати яка у вас адреса. Як знайти її розказую у наступному відео. І як чексуми прописувати
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Ось тут ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ZbLrY648QoM.html
@Koliadjun
@Koliadjun 3 года назад
Я дивився дане відео. substitutions: esphome_name: energy_monitoring # Enable Home Assistant API api: reboot_timeout: 60min password: !secret esphome_api_pass ota: password: !secret esphome_ota_pass uart: - id: pzem004 rx_pin: GPIO3 tx_pin: GPIO1 baud_rate: 9600 time: - platform: sntp id: my_time switch: - platform: uart uart_id: pzem004 name: "PZEM004T positive Reset Energy" data: [0x01, 0x42, 0x80, 0x11] sensor: - platform: pzemac current: name: "PZEM-004T V3 Current" voltage: name: "PZEM-004T V3 Voltage" energy: name: "PZEM-004T V3 Energy" filters: # Multiplication factor from W to kW is 0.001 - multiply: 0.001 - offset: 21784 unit_of_measurement: kW power: name: "PZEM-004T V3 Power" id: PZEM004T_POWER frequency: name: "PZEM-004T V3 Frequency" power_factor: name: "PZEM-004T V3 Power Factor" update_interval: 10s - platform: total_daily_energy name: "Total Daily Energy" power_id: PZEM004T_POWER filters: # Multiplication factor from W to kW is 0.001 - multiply: 0.001 unit_of_measurement: kW
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Команда на скидання показників вірна, має працювати. Я бачу - offset: 21784. Тож після скидання має показувати 21784.
@Koliadjun
@Koliadjun 3 года назад
@@BootuzDinamontuz Команда вірна але не працює)) не розумію в чому проблема...
@slavak7815
@slavak7815 3 года назад
С тремя фазами может оказаться не все так просто ... как вы собираетесь напряжение измерять ?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Вот если объясните в чем могут быть проблемы, может и найу решение.
@slavak7815
@slavak7815 3 года назад
@@BootuzDinamontuz , в сетях с трехфазным током напряжение измеряется между фазами , и там оно должно быть 380(400) в. , Да, между одной фазой и нейтраллю будет 220 ...Но я бы поостерегся измерений межфазного напряжения , не зная схемотехника данного прибора. Не претендую на истину, я, конечно, не электрик .
@slavak7815
@slavak7815 3 года назад
@@BootuzDinamontuz , да и по току тоже не все ясно ... измерить потребление по каждой фазе , сложить ?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Сразу скажу, если нет знаний и опыта, лезть в такие электросети не стоит, купите готовое изделие. Я т очно не буду рассказывать как работать с таким напряжением, так как не хочу брать на себя ответственность в том, что кто-то что-то не так увидит и услышит.
@slavak7815
@slavak7815 3 года назад
@@BootuzDinamontuz, полностью согласен
@johanwolbink1516
@johanwolbink1516 2 года назад
Very Nice Video. Please can I get the File u used in ESPHome ?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Sorry, I do not understand what files are in question? Esphome flasher can be found at esphome.io/. And the program code is in the description for the video.
@johanwolbink1516
@johanwolbink1516 2 года назад
@@BootuzDinamontuz Thanks fot your quik answher. I mean the programcode you used. I have it running but I don't get teh results. Everything is zero.
@johanwolbink1516
@johanwolbink1516 2 года назад
I have only this :# Example configuration entry uart: rx_pin: D6 tx_pin: D5 baud_rate: 9600 modbus: sensor: - platform: pzemac current: name: "PZEM-004T V3 Current" voltage: name: "PZEM-004T V3 Voltage" energy: name: "PZEM-004T V3 Energy" power: name: "PZEM-004T V3 Power" frequency: name: "PZEM-004T V3 Frequency" power_factor: name: "PZEM-004T V3 Power Factor" update_interval: 60s
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
uart: id: energomonitor_uart rx_pin: D1 tx_pin: D2 baud_rate: 9600 sensor: - platform: pzemac current: name: "220V Current" voltage: name: "220V Voltage" energy: name: "220V Energy" power: name: "220V Power" id: power_monitor frequency: name: "220V Frequency" power_factor: name: "220V Power Factor" update_interval: 1s # address: 1 - platform: total_daily_energy name: "220V Total Daily Energy" power_id: power_monitor filters: - multiply: 0.001 accuracy_decimals: 2 unit_of_measurement: kW icon: mdi:counter - platform: integration name: "220V Energy Meter" sensor: power_monitor time_unit: h filters: # Multiplication factor from W to kW is 0.001 - lambda: return x * (0.001); unit_of_measurement: kWh icon: mdi:counter restore: true switch: - platform: uart uart_id: energomonitor_uart name: "220V Energy Reset" data: [0x01, 0x42, 0x80, 0x11] time: - platform: homeassistant id: hass_time
@johanwolbink1516
@johanwolbink1516 2 года назад
@@BootuzDinamontuz I have used your code. Thank you . But i don't get the values. 220V Current = UNKNOW Etc . Please let me know what i am doing Wrong
@102diy
@102diy 2 года назад
Последовательное включение пзэмки и еспшки это конечно ещё то решение, если эта связка зарыта в щиток и к примеру вырубали напругу, то что каждый раз вот так вот эту систему заводить? ))))) что то тут определённо не так, может это связано с питанием 3.3в которые вы продаёте от esp8266 на pzem? Все таки может пзэмке для корректной работы требуется 5v и может быть не зря везде это написано, а то утверждение что работает от 3.3 это чисто эксперимент и уход от характеристик которые прописал производитель. Сегодня приехал мне этот модуль - буду проверять на выходных, но момент с включением сначала одного а потом другого - крайне кривой на мой взгляд!
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
PZEM запитывается от 220В!!!!! И в щитке стоит прекрасно и работает свзяка есп и пзем. ТОлько ЕСП нужно от блока питания запитывать.
@102diy
@102diy 2 года назад
@@BootuzDinamontuz в видео вы много раз подчеркнули момент, что сначала нужно включать pzem, а потом esp, чтобы не было посыла некоего "мусора" и соответственно при включении, чтобы в esp не регистрировалось непонятных показателей, в ситуации когда они оба стоят в щитке и при подаче 220v стартуют одновременно - в вашем случае как раз таки этот первый непонятный пакет данных летит в esp? - если так, то считаю что это небольшая но проблема.
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
@@102diy ну как бы после пропажи и включения 220В в доме, ЕСП нужно пару секунд, чтобы включится. Так что проблема не критична.
@102diy
@102diy 2 года назад
@@BootuzDinamontuz тоесть нет проблемы? Или все таки есть? Просто если она действительно остаётся то я сразу буду делать расчёт на то что нужно реализовывать таймер отложеного старта esp
@102diy
@102diy 2 года назад
@@BootuzDinamontuz на днях собрал похожую сборку (использовал ESP8266 ESP-01, т.к. их у меня куча и вполне достаточно учитывая что используется только пара пинов для связи с PZEM), прошивка у меня практически во всех устройствах Tasmota и эта сборка не стала исключением. Показательно кстати - сегодня вырубали электричество раз 10 на разные промежутки времени. Ничего в Total не подкидывает при включении - всё норм. Питание на ESP и интерфейсной части PZEM от Hi-link модуля на 5 вольт (он просто тоже у меня лежал и ждал своего часа), через стабилизатор AMS1117 на 3.3v. Выровнял показания Energy Total один-в-один с электросчетчиком, теперь наблюдаем как будет вести себя. Рано пока говорить о точности, прошло мало времени (4 дня) - на первый взгляд вроде нормально всё.
@viktor6net
@viktor6net Год назад
что за релюшка от перенапряжения?
@BootuzDinamontuz
@BootuzDinamontuz Год назад
А хз. Китайская какая-то недорогая.
@viktor6net
@viktor6net Год назад
@@BootuzDinamontuz а где покупали?
@BootuzDinamontuz
@BootuzDinamontuz Год назад
Не дам рекомендацию, там подорожала доставка существенно. И теперь она не 8 баксов стоит, а 12.
@GERGE_GERGE
@GERGE_GERGE 2 года назад
никак не получается сбрасывать показания помогите пожалуйста решить проблему
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
а это не помогает? switch: - platform: uart uart_id: energomonitor_uart name: "220V Energy Reset" data: [0x01, 0x42, 0x80, 0x11]
@GERGE_GERGE
@GERGE_GERGE 2 года назад
@@BootuzDinamontuz нет не помогает
@ulinkot
@ulinkot 2 года назад
сделай нормальный uart мостик, а не то что автор тут наплел и все сбросится. даже тупо, 5v + uart ttl converter (3.35). ну или на крайний сделай провода короче.
@dmytrokalkatin2445
@dmytrokalkatin2445 Год назад
получилось решить вопрос, как? у меня тоже не сбрасывает (
@mim2990
@mim2990 9 месяцев назад
25:20 чайник в мене пропрацював 3 роки, і здох тен. а у Вас:?
@Koliadjun
@Koliadjun 3 года назад
А ще може хтось спробував показники скидати на постачальника електроенергії?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Не сертифікований пристрій. Постачальник електрики не буде приймати таку інфу.
@Koliadjun
@Koliadjun 3 года назад
Тут питання імітувати дії внесення показників на сайті чи чат-бот. Методів якими моя компанія отримує від мене показник є багато oe.if.ua/uk/submit_metrics. Пробував esphome.io/components/http_request.html але не дуже знаюсь в тонкощах HTTP запитів. Проблема виникла у тому щоб сайт пам'ятав що я залогувався
@Asmcavr
@Asmcavr 3 года назад
А не проще взять sonoff pow2 ?
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Кому-то проще.
@Asmcavr
@Asmcavr 3 года назад
@@BootuzDinamontuz а что сложного? Интеграция в HA через ESPHOME, там все уже написано за нас- бери и пользуйся, а сервер sonoff можно смело слать лесом и полем😉
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
Sonoff pow 2 вроде как 15А меряет максимум. А тут до 100А.
@BootuzDinamontuz
@BootuzDinamontuz 3 года назад
А до 15А у меня есть розетки за 8 баксов.
@Asmcavr
@Asmcavr 3 года назад
@@BootuzDinamontuz кто вам такое сказал😉
@user-nc1zf7fi4e
@user-nc1zf7fi4e Год назад
"Воды" налил не по-детски... 🙂
@BootuzDinamontuz
@BootuzDinamontuz Год назад
Мое кино, моя вода.
@user-nc1zf7fi4e
@user-nc1zf7fi4e Год назад
@@BootuzDinamontuz Вышел на сцену - не жди только цветы, бывают и помидоры. 🙂
@neomatic3988
@neomatic3988 2 года назад
Оценивать точность китайского устройства относительно другого китайского устройства это так по домашнему 🤣
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
У вас в доме полным полно китайских устройств. Или нет?
@neomatic3988
@neomatic3988 2 года назад
@@BootuzDinamontuz конечно. А вас?
@BootuzDinamontuz
@BootuzDinamontuz 2 года назад
Да тоже до чёртиков. И работают, точные. И в ближайшем магазине электрики вы купите такие же китайские вольтметры, только типа фирменные.
@neomatic3988
@neomatic3988 2 года назад
@@BootuzDinamontuz так и комментарий был, относительно выражения в видео - точные. Относительно чего? ))) хоть бы относительно китайской цешки. Чтобы не быть голословным ))). А так, если бы правильнее выбрать выражение, то - Относительно точное.
@dexxxqqq
@dexxxqqq Год назад
Спасибо за видео. 3.3 вольта действительно с ESP32 ему хватает. Но не получается ничего считать, не выдает никаких показаний. Брал с гитхаба скетч. #include #include HardwareSerial PzemSerial2(2); PZEM004T pzem(&PzemSerial2);
Далее
Она Может Остановить Дождь 😱
00:20
Она Может Остановить Дождь 😱
00:20