Тёмный

FibroPool Heat Pump Installation Guide (Covers ALL Models) 

FibroPool
Подписаться 574
Просмотров 26 тыс.
50% 1

In this video, we'll walk you through the entire installation of one of our heat pumps (in this case the FH055/255). If you purchased a different model, don't worry-all models have a very similar process. The 3 way bypass valve is required only:
1. If pool pump is 1.5 hp or more
2. If plumbing is 2"
3. If you have multiple return jets on your pool (at least 3 returns).

Хобби

Опубликовано:

 

26 июн 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 6   
@jenniferhouston1682
@jenniferhouston1682 21 день назад
We just set up our new fh255 heat pump but the fan will not start? What could be causing this?
@edwardpena655
@edwardpena655 Месяц назад
What if my pressure gauge is at 3.7 mpa, is that a problem?
@Fibropool
@Fibropool Месяц назад
Yes that's a problem. My first guess is that your heater isn't getting enough water flow to collect heat from your unit, so it's building pressure inside. Could be either an underpowered pump or a bypass that's not open enough (if you have one). You may be sending just enough water to not trip the flow switch.
@mahakarsha
@mahakarsha 9 месяцев назад
This is soo wrong. Where is the one way value for the heater return. In this config you are still going to feed the heater when you bypass the heater only in reverse way. Come on guys. People are going to follow your video and should not be this bad. Also, there should be a one way valve just before the salt generator.
@Fibropool
@Fibropool 9 месяцев назад
When you have a situation like this with gravity drawing water away from the heat pump and salt generator, those are good points but not strictly required. Still, there is nothing wrong with adding those valves in this situation, and we do generally recommend including them, if possible. Thanks for the comment!
@peppy.kay11
@peppy.kay11 Месяц назад
Thanks for this comment! Unfortunately, I didn't read it before I set everything up. So now I'm going to have to adjust and add a one-way valve to the heater line that feeds to the Tee. Would a one-way check valve for sump pump work? Or is there something else I need to get?
Далее
Do I need a heater bypass?
2:38
Просмотров 22 тыс.
Поём вместе с CLEXXD🥵 | WICSUR #shorts
01:00
Fitting a new air source heat pump for this pool
10:58
Pool Heat Pump Calibration Explained (Madimack)
14:12
Fibropool FH-120 problem
2:00
Просмотров 1,3 тыс.
FibroPool Heater   Getting Started
1:44
Просмотров 4,1 тыс.
Fibropool FH-120 unboxing and installation
13:47
Просмотров 4,8 тыс.
FibroPool Heater   Getting Started
1:44
Просмотров 33 тыс.
Первая встреча 💙
0:37
Просмотров 1,2 млн
Nika loves to eat chicken #cat #cats
0:17
Просмотров 56 млн
Как то так🤷🏼‍♀️❤️
0:31
Просмотров 2 млн