Тёмный

Fire hose pressure test - Procedures explained in detail 

Hope at Sea (Prasobh Sugadhan)
Подписаться 7 тыс.
Просмотров 4,4 тыс.
50% 1

This is a video detailing the procedure to carry out a fire hose pressure test onboard. It needs to be carried out as per company SMS Manual.
Any defects need to be rectified at the earliest. Also, a entry needs to be done both in FFA PMS as well as Deck log book.
I hope this video will help you in your future career paths ❤️.

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@prasobhsugadhan
@prasobhsugadhan 2 года назад
Dear viewers, May I kindly request you to SUBSCRIBE and click the BELL ICON for keeping this channel growing. Thank you.
@sebuhihesenzade8268
@sebuhihesenzade8268 Год назад
@prasobhsugadhan Good day Sir. I have 2 questions regarding pressure test 1.Do you open any anchor wash or any other fire hydrant when you conduct this test? Or you don't ? 2.I have watched other videos and I noticed that some people closes also fire hydrant after nozzle shut off and when the hose attained required pressure .Is it correct or not? Because if i close also hydrant it can damage fire main system and lines of vessel kindly clarify this issue Best regards
@prasobhsugadhan
@prasobhsugadhan Год назад
Logically, since the fire pump is a centrifugal pump, the line can never be over pressurized. Also, there is a relief valve fitted. Now, coming to actual working situation, atleast the anchor wash will be kept partly open, so that any surge pressure can be avoided. The pipeline, as it gets old, loses its strength internally due to erosion and pitting. Externally due to corrosion. Hence, to deal with untoward rupture, the easiest way is to keep the anchor wash slightly open so that the line will never over pressurize. Regards ♥️
@sebuhihesenzade8268
@sebuhihesenzade8268 Год назад
@@prasobhsugadhan Appreciate. Best Regards
@prasobhsugadhan
@prasobhsugadhan Год назад
Thank you sir Regards ❤️
@ChiefAndy-du
@ChiefAndy-du 3 месяца назад
must rinse with Fresh water, otherwise easy easy damage by salt water
@prasobhsugadhan
@prasobhsugadhan 3 месяца назад
Yes sir. Appreciate the feedback. Regards ♥️
@amemathew
@amemathew 2 года назад
Thanks for the video, informative stuff. Keep uploading 🙏🏽
@asmeahagos1192
@asmeahagos1192 2 года назад
Perfectly explained thank you GBU
@prasobhsugadhan
@prasobhsugadhan 2 года назад
Welcome sir.
@rocabscabrera
@rocabscabrera 2 года назад
interesting topic again today😀
@prasobhsugadhan
@prasobhsugadhan 2 года назад
Thank you sir for making my day. 😂
Далее
ХОМЯК ВСЕХ КИНУЛ
10:23
Просмотров 634 тыс.
DFR Hose Testing Procedures
14:15
Просмотров 4,7 тыс.
Fire Plan Container - Contents Explained
4:44
Просмотров 2,9 тыс.
Rocket Stability
12:45
Просмотров 282 тыс.
How to Pressure Test a Fire Hydrant
4:50
Просмотров 18 тыс.
FURUNO FE 700 ECHOSOUNDER EXPLAINED IN DETAIL
12:26
Просмотров 12 тыс.