Fnirsi HRM-10 Internal Resistance Tester 

Julian Ilett
Подписаться 200 тыс.
Просмотров 5 тыс.
50% 1

A precision internal resistance and voltage tester with 4-wire probes and an easy-to-read LCD display.
The voltage measurement has 4 decimal places of precision and the resistance measurement has a precision of 0.01 milliohms.
AliExpress: s.click.aliexpress.com/e/_oE6...
Amazon: www.amazon.com/FNIRSI-Resista...
Code: FNUK22
Time: July 11th - July 24th

Наука

Опубликовано:

 

10 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 33   
@firasgh871
@firasgh871 14 дней назад
شكرا على الفيديو لقد تمنيت أن ارى ذلك من زمن
@G1ZQCArtwork
@G1ZQCArtwork 20 дней назад
Hmmmm, odd question, that tube is metal, and therefore just shorting the probes, so why not just touch the cell contacts with the jaws together.!? These meters use Twin wires because the extra wire is a sense wire, to remove the resistance of the probe cables.! What am I missing.?
@dino6627
@dino6627 20 дней назад
By doing this the resistance of the probe cables is still not being measured, but the resistance of the tube and extra contact point will be measured. From the video it seems to be low enough, but I would prefer to use a plastic or foam insulator between the probe contacts to keep them apart and use them directly.
@JulianIlett
@JulianIlett 20 дней назад
Yeah, for some reason that doesn't work. If you just touch the closed probes onto the ends of a cell, the resistance reading is too high and very unstable.
@EsotericArctos
@EsotericArctos 19 дней назад
I have seen budget oscilloscopes from the same company. They are okay for general use, but found them quite inaccurate with measurements, sometimes 10 percent or more out on the measurements. It looks like this device may be slightly more accurate than the oscilloscopes, but maybe still a little out.
@vink6163
@vink6163 7 дней назад
An 18650 battery holder might be easiest - you could mount it on a wooden board and connect the probes (or even buy a four-pin connector and wire it directly to the battery holder) so measuring a bunch of cells is as easy as putting them in and out of the battery holder.
@firasgh871
@firasgh871 14 дней назад
ماهو اسم الجهاز الأخر ورقم الموديل . ملاحظة : يجب على مصنعين البطاريات أن يكون النحاس الصافي المغلفن هو ونهاية التوصيلات حتى ةان كان على شكل برغي ويفضل صولية بفتحة للربط السهل مع بطاريه أخرى
@tonyh6309
@tonyh6309 19 дней назад
A simple solution is to use 2 small magnets, eg. 5x5x3mm, with insulation between them, attached to a battery terminal. Then clip the Kelvin clips across the magnets. The bigger the magnets the greater the clamping force to the battery terminal, minimising resistance (or more importantly variation in contact resistance) during the measurements. Obviously the limit is how wide the Kelvin clips will open and the size of the battery terminal. This arrangement allows a hands-off measurement eliminating variations from varying hand pressure.
@stub1116
@stub1116 17 дней назад
When are going to do some more projects with microcontrollers' ?
@GadgetReviewVideos
@GadgetReviewVideos 19 дней назад
one solution that comes to mind is putting an insulator between the clamps that keep them separated and then taking the ends and touching them to the end of the battery.
@RichardSloan65
@RichardSloan65 19 дней назад
I haven't read the comments yet I'm thinking the copper tube might as well been left out
@kapegede
@kapegede 20 дней назад
How about testing inductors and capacitors in comparision to a Mesr-100 ESR meter?
@mauanderuk
@mauanderuk 19 дней назад
Or for find shorts on PCB's
@ErrorMessageNotFound
@ErrorMessageNotFound 19 дней назад
Do they have alternative probes available ?
@flagpoleeip
@flagpoleeip 19 дней назад
The voltage reading 18650 Li-ion was exactly the same on both meters??? why did you say it wasn't?
@vink6163
@vink6163 7 дней назад
It wasn't exactly the same, there was about 10 millivolts of difference, which is relevant when it's supposed to measure to an accuracy of 0.1 millivolts. It would be like using meters that measure to the nearest volt, and one reads 3 volts but the other reads 103 volts. Quite a big difference given the precision it's supposed to have.
@vytautasslenderis2702
@vytautasslenderis2702 5 дней назад
Why did you insert those copper tubes? No need. Simply close the probes, the short length of the tips will have almost no effect. You still inserted another piece of metal, which may have even more effect on the readings, one more contact point. "Solving" one problem by creating another :)
@lint2023
@lint2023 20 дней назад
What was that small scope you used?
@JulianIlett
@JulianIlett 20 дней назад
It's an Aarontek 30MHz, but there are dozens of small handheld scopes available now.
@singlesteve2011
@singlesteve2011 19 дней назад
you could of used a small peice of nickel strip spot welded to the 18650
@andyshap
@andyshap 20 дней назад
Would a magnet work? Solder a block to the magnet and the probes grab the block. Attach magnet to the end of the cell.
@JulianIlett
@JulianIlett 20 дней назад
I've just checked a magnet - it's resistance is about 1.5mohm - quite a bit higher than the copper tube which was about 0.03mohm. Also, soldering to a magnet is problematic - heat damages the magnet.
@andyshap
@andyshap 19 дней назад
@@JulianIlett it was worth a try! Thanks, Julian. I would think a battery holder would work
@Brian_Of_Melbourne
@Brian_Of_Melbourne 19 дней назад
@@andyshap Clipping the Kelvin Clips to an 18650 battery holder seemed like the obvious solution as soon as the 'problem' was raised.
@juancarlossandoval5628
@juancarlossandoval5628 11 дней назад
Thanks foe the review. Have you check its accuracy? Planning to buy this for lion batts ang capacitor Internal resistance test job.
@craigtucker777
@craigtucker777 8 дней назад
I will NEVER buy something with scraped numbers off components, that means I can't repair it witch means I don't own it
@vink6163
@vink6163 7 дней назад
How would you repair something with a microcontroller in it that has embedded, locked, flash? You can read the chip number and replace it, but without the firmware it still won't function. So having chip numbers on it probably won't help with repairability. Scraping numbers off the chips is only done so they can use factory seconds destined for the rubbish and not get caught by the company that paid to have the chips fabricated, it's not done to hide anything from the buyer.
@craigtucker777
@craigtucker777 7 дней назад
@@vink6163 but they erase markings even on opamps, I dont care for their reasons, I'm not bying fnirsi and simmilar e waste anymore.
@craigtucker777
@craigtucker777 7 дней назад
@@vink6163 RU-vid keep deleting my comments, why scrub numbers on opamp? Just no
@craigtucker777
@craigtucker777 7 дней назад
@@vink6163 so why from op amp
@vink6163
@vink6163 6 дней назад
@@craigtucker777 It probably didn't meet the specifications, or the batch was found to fail early, or had some other problem so the company didn't want it released with their brand name on it, so they told the factory to destroy them. But many Chinese factories just scrape the numbers off and sell them cheap for low-cost products where either they don't care if it breaks, or the problem with the component doesn't matter. The companies making the chips don't like it because it means people aren't buying their proper chips and they're not getting royalties, but it seems to be difficult to stop it from happening.
Далее
My First Sodium Ion Battery
22:16
Просмотров 41 тыс.
I Built a EXTREME School Bus!
21:37
Просмотров 7 млн
I Don't Get Why People Still Use These Joints
17:26
Просмотров 624 тыс.
Junctek BL105F Coulometer
22:30
Просмотров 3,9 тыс.
Every Component of a Switch Mode Power Supply Explained
23:10
Fnirsi FNB58 USB Fast Charge Tester
21:12
Просмотров 18 тыс.
Battery  low 🔋 🪫
0:10
Просмотров 13 млн
iPhone socket cleaning #Fixit
0:30
Просмотров 17 млн