Тёмный

Freezing in HVAC Systems 3D 

HVAC School
Подписаться 351 тыс.
Просмотров 60 тыс.
50% 1

In this 3D video, we look at the causes and effects of freezing in HVAC systems (buildup of frost or ice on the equipment).
Water freezes at 32°F or 0°F. When a surface, such as an evaporator coil, is below water’s freezing point and contains moisture, frost or ice may form on that surface. In many cases, freezing in HVAC systems starts at the evaporator coil and works its way out; freezing can happen when the suction saturation temperature stays below 32°F for an extended period of time.
Some HVAC/R applications, such as commercial freezers and heat pumps in heating mode, need to operate under below-freezing conditions; the formation of frost or ice will hinder heat transfer over time, and periodic defrosting will be required. Evaporator coils in cooling mode should NOT freeze; when freezing happens, it will block system airflow. In general, evaporator coils will be about 35°F below the return air temperature.
The rate at which freezing occurs will depend on the amount of moisture in the air, the length of time at which the evaporator coil temperature is below freezing, the temperature of the return air, the air velocity, and the overall coil design.
When you encounter a frozen system, allow it to defrost completely before troubleshooting. You may allow the system to defrost by leaving it off with (or sometimes without) the blower running. In some cases, you may be able to use a heat gun or run the heat pump in heating mode for a short period. Be mindful of the water as the ice melts and take steps to prevent water damage.
A low evaporator coil temperature may be caused by low load (low airflow and/or low indoor temperature), refrigerant undercharge, low outdoor ambient temperatures, blower issues, and refrigerant side restrictions. We can prevent low load by advising customers not to set their thermostats below 72°F in cooling mode on standard equipment. We can also prevent low airflow from being a factor by making sure we replace dirty filters and clean the evaporator coil and blower wheels as necessary. When freezing happens due to a low refrigerant charge or a restriction, we may also notice high superheat; in humid climates, freezing of this nature can cause the entire system to freeze up.
Buy your virtual tickets or learn more about the HVACR Training Symposium at hvacrschool.com/symposium.
Read all the tech tips, take the quizzes, and find our handy calculators at www.hvacrschool.com/.

Опубликовано:

 

5 июл 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 47   
@jpenn727
@jpenn727 Год назад
Great video and content. Thank you!
@jaymz0074
@jaymz0074 Год назад
The fact that you put out free education with your own time is amazing. Hope Jesus blesses you and your family mightily.😊
@sayfassunnah3310
@sayfassunnah3310 6 месяцев назад
Become Muslim. Jesus is a Prophet in Islam.
@jaymz0074
@jaymz0074 6 месяцев назад
@@sayfassunnah3310 allah is a fake God, Jesus Christ is the way and truth and life for eternal salvation.
@matttzzz2
@matttzzz2 3 месяца назад
Both of you are deluded. Allah isn't a god and Jesus was just a jew who got killed for trying to be a cult leader
@easygrowingcanadian1359
@easygrowingcanadian1359 11 месяцев назад
One more small note, when it comes to airflow, always check return air vents and make sure they're not blocked or extremely dirty, because then it's exactly like having a clogged filter
@Garyganeu
@Garyganeu 11 месяцев назад
Great basic fundamentals that every HVAC tech needs when diagnosing a frozen evaporator coil.
@hoivien3001
@hoivien3001 Год назад
Thank you a lot for this channel.
@jameskennett8666
@jameskennett8666 11 месяцев назад
The visuals in this video 🔥🔥🔥
@imrocSupermarketRefrig
@imrocSupermarketRefrig Год назад
Outstanding graphics presentation.
@iraniantrucker9311
@iraniantrucker9311 Год назад
Awesome video thanks for your support
@BigSad49702
@BigSad49702 4 месяца назад
Did a better job at helping me understand this than my instructor.
@mperry94
@mperry94 Год назад
Thank you!
@padilla7019
@padilla7019 Год назад
Great information and very clear
@JaykeSapalaran-iq3qs
@JaykeSapalaran-iq3qs Год назад
Great video presentation ❤
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Thankyou for the video. Please do more
@brianmcdermott1718
@brianmcdermott1718 Год назад
Good info, Thanks Bryan.
@edwinbarahona4486
@edwinbarahona4486 11 месяцев назад
Thank you. For the Information.
@kidkider4237
@kidkider4237 Год назад
Thank you for this!
@johnd6111
@johnd6111 Год назад
Great Video
@rubenrojas8632
@rubenrojas8632 Год назад
GREAT VIDEO THANK YOU.🥶
@vitaliimazur9218
@vitaliimazur9218 Год назад
Thanks a lot for this video
@reyeslirio4127
@reyeslirio4127 11 месяцев назад
I like your explanation good job.
@briantagg2678
@briantagg2678 3 месяца назад
Nicely Done! 🤝✌️
@DavidBendel
@DavidBendel Год назад
Thanks!
@bikerbobcat
@bikerbobcat 11 месяцев назад
Good video, good reminders. Straight to the point. Got sent to deal with a frozen rooftop commercial unit last week and everyone was scratching their heads (filter is good, right? Blower's moving, right? Got pressure right?). Meanwhile nobody bothered to clean the solid compacted dust on the indoor return grills, pulling so hard it was picking them up... But hey, that's why they pay me the big bucks on colorful paper. XD
@AndyGaudet
@AndyGaudet 11 месяцев назад
I just want to say that I really appreciate all the advice and knowledge you give to us in your videos, and I can't thank you enough for taking the time to make ones like these (with all the animations). All hats off to you and your team. 🫡
@soleilsoleil8287
@soleilsoleil8287 Год назад
Magnificent
@Uncle_Jesse
@Uncle_Jesse Год назад
great vid
@joshuapitong899
@joshuapitong899 11 месяцев назад
Thank you.😊
@georgepruitt637
@georgepruitt637 Год назад
Just like they taught us-- back in 1972 !!!!
@OziBlokeTimG
@OziBlokeTimG Год назад
Nice work bro
@MAGAMAN
@MAGAMAN 11 месяцев назад
Just had this happen due to undersized copper tubing that wasn't replaced when the AC was updated. A nice little $1400 repair.
@inflateopassion
@inflateopassion Год назад
THANK s
@frankdiaz433
@frankdiaz433 11 месяцев назад
excellent
@ChristopherSugg
@ChristopherSugg Год назад
I've asked this so many times but is this a software you are using or do you pay someone to create the video? I am an HVAC instructor and would love to make content like this for my class to cover specific lessons.
@HVACS
@HVACS Год назад
Yes I work with a professional 3D animator
@hejimmy1722
@hejimmy1722 11 месяцев назад
Very good
@cristianramirez-zj2nj
@cristianramirez-zj2nj Год назад
Awesome video !! Can you make and talk about diagnosing reversing valves ? Bypassing ?
@marklongo4847
@marklongo4847 27 дней назад
Why does low refrigerant cause this though? Just would like a better understanding of why low amount of refrigerant in the system would cause ice up
@sonGOKU._.
@sonGOKU._. 11 месяцев назад
What if you have 40 degree coil, 10 degree sub cool(txv) suction 126 liquid 312 but the suction line temp doesn’t goes below 68 f?
@Cypher15100
@Cypher15100 11 месяцев назад
Does the coil temperature to air difference differ in refrigeration? I’m a refrigeration apprentice and was told the coil is 10-15° cooler than the space, but this video is saying it’s a 35° difference
@chasecampoli4830
@chasecampoli4830 11 месяцев назад
First art I assisted video?
@davidsaldate1562
@davidsaldate1562 11 месяцев назад
My system freezes sometimes because the blower fails to start with the compressor. I have a split system. This can happen once or twice a month, specially during the monsoon season. I just turn off the system, wait to de-freeze and I am good for another couple of weeks until it happens again. Any ideas? Could it be the blower capacitor?
@mohammadhamayoon9538
@mohammadhamayoon9538 11 месяцев назад
@f.villanueva
@f.villanueva Год назад
🤍👍👍👍❤
Далее
Diagnosing a Grounded Compressor 3D
6:30
Просмотров 25 тыс.
КАКОЙ У ТЕБЯ ЛЮБИМЫЙ МАРМЕЛАД?
00:40
КТО ЭТО БЫЛ?
25:31
Просмотров 736 тыс.
Class - What Superheat Signifies
17:07
Просмотров 227 тыс.
Diagnosing a Locked Compressor 3D
10:02
Просмотров 43 тыс.
Why does an AC freeze
23:39
Просмотров 146 тыс.
AC LOW on Refrigerant! How To Know!
7:16
Просмотров 55 тыс.
Oxy-Acetylene Brazing 3D
15:47
Просмотров 143 тыс.
How to Fix Frozen AC Coils in 10 Minutes
10:15
Просмотров 15 тыс.