This one covers how the gas valve on the millivolt system is wired.
This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. If you have suggestions or comments they are welcome.
If you are a homeowner looking to repair your own appliance, understand that the voltages can be lethal, the fuels are highly flammable and high pressures are used. Know your limits.

Хобби

Опубликовано:

 

17 окт 2013

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 200   
@grayfurnaceman
@grayfurnaceman 10 лет назад
Thanks for the support. More coming. GFM
@grayfurnaceman
@grayfurnaceman 10 лет назад
thanks for the support GFM
@tbonemoon1330
@tbonemoon1330 3 года назад
I just started working for a HVAC company who is the only company in my area who works on fireplaces that they didn't install and I never learned anything about fireplaces in school so your videos are very helpful.
@grayfurnaceman
@grayfurnaceman 3 года назад
Glad it helps. GFM
@Lazyguy2112
@Lazyguy2112 7 лет назад
thanks gray man, had a service call today on a wall heater. wasn't sure why it wasn't working from the stat but I think you just explained it to me.
@grayfurnaceman
@grayfurnaceman 7 лет назад
Glad it helped. GFM
@nesc39
@nesc39 8 лет назад
Awesome video. I had no idea how my tstat was making my boiler fire without a transformer! Now I know
@kensolis1708
@kensolis1708 5 месяцев назад
Thank you grayfurnaceman. Been watching your videos and not only did I save money but I also learned a lot from you.
@grayfurnaceman
@grayfurnaceman 5 месяцев назад
Thanks for the support. GFM
@grayfurnaceman
@grayfurnaceman 10 лет назад
There are a couple more of these coming. GFM
@geojor
@geojor 10 лет назад
another informative video, thanks for your efforts...
@Rinebo
@Rinebo 5 месяцев назад
Been learning from you for over a decade now!
@russomd
@russomd 7 лет назад
You saved me a $1000 with these videos. THANK YOU!!!
@grayfurnaceman
@grayfurnaceman 7 лет назад
Glad you got it going GFM
@iluvbowhuntingtoo
@iluvbowhuntingtoo 9 лет назад
very informative ... thanks for taking the time to do this video
@grayfurnaceman
@grayfurnaceman 9 лет назад
iluvbowhuntingtoo Welcome. GFM
@99.99.9
@99.99.9 3 года назад
Thanks for the video. What is under the brass colored screw on the top right, and what does it do?
@nickjeschelnig3346
@nickjeschelnig3346 8 лет назад
I want to convert this to LP! What spring conversion kit would i need ? TY!!
@mnalep2
@mnalep2 9 лет назад
Hi Gray, I have a gas valve chain, on an old Luxaire, (SH-125). The gas valve is a Honeywell VS87A9X4X2. I replaced the limit switch about 3 years ago. I think I replaced the thermopile about 5 years ago (but I am not positive I replaced, maybe I just cleaned it). About once, or twice, a winter the main burner does not ignite - even though the pilot is on and thermostat is calling for heat. I have found that if I tap on the valve chain, it will usually ignite after a few taps. Do you think this is a thermopile issue, or gas pressure issue, or sticking gas valve issue, or something else. I replaced the limit switch about 3 years ago. I have some pictures of the gas valve train, but not sure how to post them here. The gas valve has 6 screws with wires attached - 2 screws for Thermostat (TH1 and TH2), 2 screws for thermopile/Pilot generator (RED, WHITE), and 2 screws for the limit switch (L1 and L2). I watched your videos on thermopiles, and antique furnaces. That got me to think I should put a meter on the gas valve, both while the burners are on, and after burners kick off. (I thought the millivolt readings might be useful to compare against later if it does not light again later this winter). These are what I thought I saw: 1) With the burners on: T-stat wire leads read 126 (on 200 mvDC scale) LIMIT switch leads read -4.5 (on 200 mvDC) Thermopile leads read 1 (on 200 mvDC), and 379 2000 mvDC 2) After the burners tripped off: T-stat wire leads read 1 (on 200 mvDC scale) and 611 on 2000 mvDC LIMIT switch leads read 0 (on 200 mvDC) Thermopile leads read 1 (on 200 mvDC), and 630 2000 mvDC I only changed to the 2000 mvDC setting if I saw reading of 1 on the 200 mvDC setting. Are these readings looking correct to you for a functioning gas valve? That is, am I reading it right? I ask because one of your videos showed, I think showed, 544 mvDC when you put a flame on the thermopile, and 310 mv with the pilot on it, and you stated a thermopile will trigger the valve at between 125 to 300 mv. (My readings seemed to be from 379 mv to 630 when I put the meter in the 2000 mv range). Also the autoranging meter you used displayed "0.544" - which I thing you said was 544 mV? I used a manual ranging meter, and mine showed as "379" on 2000 mV. (I hope I am getting this right?) Can you help me diagnose what I am seeing, and what might be wrong? I can send pictures of the valve if that would help. Thanks
@terrylight3086
@terrylight3086 7 лет назад
thank you..i could not understand when I removed my wall furnace, I had no power going to it.. was making me nervous I was missing something in the wall!
@SendLead
@SendLead 10 лет назад
great refresher its been a while since I've delt with one.
@m.n.3490
@m.n.3490 8 лет назад
Hi Gray. I have watched many of your videos and they are great and educational. Thanks you so much for sharing your experience! I now have a problem with a new combination valve that I just installed on a milllivolt (thermopile generator) on Luxaire SH-125 gas furnace. (I replaced the valve as the main burners sometimes did not come on unless I tapped the regulator/gas valve. The old valve was a nuisance having to tap on it occasionally to open the gas valve, but it worked fine otherwise - including the pilot). The old valve was a Honeywell, with six screws in the valve body for all the leads It also had a pilot line that was fed off of a separate gas cock mounted just before the main gas cock valve. This is different from the new installed WhiteRodgers valve where the pilot line feeds out of, and is controlled by, the new combination valve. Could this be the reason the pilot goes out on high LIMIT - it is no longer indepandent of the valve control unit? The new valve seems to work fine up until the point where the limit switch is tripped and at that event the combination valve 'clunks' and main burners close - and the pilot flame goes out. So at that point the furnace is no longer operational since the pilot light is off. I had my multi meter on the two leads of the thermopile's connections at the combination valve at TH-PG and PG. The millivolts reading was 400 Mv with only the Pilot on. It drops to about 375Mv when the burners come on. When the LIMIT activates, the millivolts readings immediately drop, and the main burners and the Pilot flame both go off. (That is how I knew the pilot went out at that moment - the millivolts sudden drop and observation that pilot was out.) My new valve looks just like the on in this video. The new combination valve is actually a WhiteRodgers 36C03U, for 750 millivolt pilot generator furnaces. I have wired the limit, pilot generator and thermostat as described in the installation instructions, with the LIMIT switch leads on the power 'pigtail' of the screw in power feed, and the TH-PG terminal. The pilot generator leads are to the TH-PG, and the PG terminals, on the combination valve. The thermostat wires are to the TH, and TH-PG screws. (Not sure which is red or white at that point, as it is just two black wires in the furnace cabinet - but I assume it does not matter?) Could I have a faulty gas valve (even though it's brand new)? Have I wired something wrong? Is the Thermopile ok? (is 400 MV while connected to the combination valve) and just the PILOT FLAME adequate voltage? Do you think I need a new thermopile? I am really stumped. I can even turn the gas cock on the combination valve off, and on, several times, and the PILOT stays lit whilte the burners go off and on. The PILOT stays lit when the main burners fire up, and when the blower motor comes on. It seems wrong that the LIMIT switch should turn off the main burners and the PILOT FLAME! Should I cap the pilot outlet on the combination valve and put the pilot line back to the old, separate, pilot gas cock? Please, any help you can give me would be much appreciated. Thanks, Matt mnalep@aol.com
@gods959
@gods959 Год назад
Great tutorial, thanks for sharing your knowledge. New subscriber
@HVACShopTalk
@HVACShopTalk 10 лет назад
Good info, thanks
@dennisqwertyuiop
@dennisqwertyuiop 10 лет назад
These were used on gas logs for fireplaces I seen many
@rodgraff1782
@rodgraff1782 Год назад
Williams went to a very small generator for their wall furnaces, that gave us headaches for years. I think it only produced 180 millivolts. You could only use the length of thermostat wire that they gave you. You have to keep the T stat wire away from 120 volt wires. I had a wall furnace that would turn on every time the refrigerator ran. Caused by running the stat wire too close to the 120 volt romex supplying the refrigerator.
@grayfurnaceman
@grayfurnaceman Год назад
That's a cool one. I have not seen that thermopile. Must have been fun to diagnose. GFM
@grayfurnaceman
@grayfurnaceman 10 лет назад
Thanks. More coming
@oabus
@oabus 7 лет назад
that was royal RFT-50 OIL fryer.
@mrsayao
@mrsayao 7 лет назад
Hey GFM! I love your videos! Can you explain how a high limit switch would be wired on these 3 terminal millivolt systems? Seems like our old 4 terminal millivolt gas valve won't keep the pilot lit. I swapped out the thermopile even though it tested good =\. The bi-metal limit switch is reading some resistance, however in hindsight, I didn't remove it completely from the system. Are limit switches normally open or closed on these millivolt systems?
@grayfurnaceman
@grayfurnaceman 7 лет назад
The limit is usually wired in the TH circuit. Limits are usually normally closed. GFM
@brianahrendt7596
@brianahrendt7596 7 лет назад
Hey, great videos. I have a Hearthstone Sterling DV nat gas stove. 12 years old, don't use it much. Leave it shut down 6 months. Just started it up, had a hard time keeping pilot to stay lit. Took quite a few tries. After it finally stayed lit, I turned on T Stat remote and gas valve did not open. A few tries and it finally ignited both burners. After a minute, all went out. Same thing a few times in a row. This unit has a thermocouple and a thermopile. Which one do you think I should replace? Thanks for the help!!
@grayfurnaceman
@grayfurnaceman 7 лет назад
If the pilot is blue and covering the thermocouple and thermopile, you could have a problem with output from the thermopile. You should have 325 MV or more output with the burner off. Be sure all wire terminals are tight. Hope this helps. GFM
@gerardomireles122
@gerardomireles122 8 лет назад
very nice good video Gray
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Gerardo Micelles Merry Christmas GFM
@lelecocopuffs
@lelecocopuffs 8 лет назад
nice never see one like this before
@danm9718
@danm9718 3 года назад
Can anyone tell me how to connect a draft spill switch to a millivolt system?
@jottie4213
@jottie4213 9 лет назад
BTW thanks for your posts
@billyrayhartman8864
@billyrayhartman8864 6 лет назад
I have a White-Rogers millivolt gas valve on a gas log Model # 36C03U-333 I just installed this new gas valve the thermopile is putting out 500 millivolts I put in a new one. I have wired the thermopile to the TH-PG and PG terminals and the wall switch to the PG and TH terminals. The pilot light is strong the wall switch ohms out good. The gas valve won't open even if I jumper from PG to TH. This is the second valve I have put in thought the first one was bad but not 2 in a row. Any suggestions out there would be welcome Thanks Bill
@grayfurnaceman
@grayfurnaceman 6 лет назад
Is there a limit switch that you have not found? GFM
@wdhewson
@wdhewson 10 лет назад
Thanks. More good work. Have you ever taken apart a "typical" gas valve and made a video to share with us?
@grayfurnaceman
@grayfurnaceman 10 лет назад
Actually I have. Look here: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-DLxhKrSEDwE.html
@jottie4213
@jottie4213 9 лет назад
to install a milivolt thermostat would you connect to the same terminals as the on off switch on a gas fireplace/stove. Which terminal or terminals have the voltage present.
@grayfurnaceman
@grayfurnaceman 9 лет назад
Jan Otting Just use the same terminals as the switch. Be sure all connections are tight. GFM
@jottie4213
@jottie4213 9 лет назад
Thank You sir
@martincortez1337
@martincortez1337 9 лет назад
thanks is very informative can you explain how to replace a gas valve of fireplace?
@grayfurnaceman
@grayfurnaceman 9 лет назад
Martin Cortez First, have very small hands and prepare to swear. I did a video on gas valve replacement. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-g8jMJIBVRGo.html Good luck. GFM
@grayfurnaceman
@grayfurnaceman 10 лет назад
Thanks. I'm rather simple minded so I guess it follows. GFM
@tomlawrence4394
@tomlawrence4394 6 лет назад
I have a gas fireplace that we don't use but I know works. Right now I have a wire (low voltage) sticking out of the wall. I think it used to be a thermostat but it's been a while and I forget. Was going to just connect it to a switch, but there is no electrical box in the wall, just a wire sticking out of a hole. To use the fireplace now, I just need to connect these wires. It's long due for me to deal with this eyesore, but what do I use? Just get a thermostat or should I cut open the wall and put in a box and a switch? It's all finished drywall so I'd rather not open it up if I don't have to.
@grayfurnaceman
@grayfurnaceman 6 лет назад
You can use a standard light switch. Just replace the screws with moly type drywall fasteners. Can then mount a switch covert the light switch.
@thatcryptoguy7313
@thatcryptoguy7313 5 лет назад
Awesome video. Hope you can help.My thermostat won’t turn on my boiler. Boiler is running but doesn’t care what thermostat says. Any ideas?
@grayfurnaceman
@grayfurnaceman 5 лет назад
By running, do you mean there is an inducer fan running? GFM
@mark.r8900
@mark.r8900 5 лет назад
hi, i thought this gas valve is composed of a pilot valve and a main gas valve. so if the main valve solenoid is between TH and PG , then the pilot gas valve must be between Th-PG and PG? is this correct? thanks.
@grayfurnaceman
@grayfurnaceman 5 лет назад
There is no PG terminals in most of these valves. GFM
@jp410
@jp410 Год назад
Great video, GRM. Thank you for your thoroughness. Can you shed any light on the types of furnace gas valves that were outlawed, the kinds with the red plastic dials? I'm going to need to be able to identify whether our cabin has one of those valves or not, in my efforts to get it working. I was told those can no longer be replaced or found.
@grayfurnaceman
@grayfurnaceman Год назад
Give me a brand and model # of the valve. GFM
@jp410
@jp410 Год назад
​@@grayfurnaceman Don't know, but I'm heading up tomorrow, I'll get back to you on it. Thank you. And yes, it's GFM not GRM isn't it.
@grayfurnaceman
@grayfurnaceman Год назад
@@jp410 Yup. GFM
@jp410
@jp410 Год назад
@@grayfurnaceman Honeywell (I believe) is the brand, and the model is VS821A1277. The guy I spoke with from Williams mentioned that it's the IT valves that were discontinued, and are difficult or impossible to replace. I haven't been able to find out what an IT valve is, or whether the one we have is one of those.
@econowestheatingairplumbin2945
nice work
@grayfurnaceman
@grayfurnaceman 7 лет назад
Thanks for the support. GFM
@gyver471
@gyver471 4 года назад
So what terminals would you put the leads to test for voltage?
@grayfurnaceman
@grayfurnaceman 4 года назад
On this valve, between TH and PG. Also, you can look for the curly line and check between the 2 ends. Look at 4:25 on the video. GFM
@EurekaRecycler
@EurekaRecycler 9 лет назад
Me again, on a 2 wire valve what should the resistance reading normally be? I disconnected the thermopile/ PG and the pilot lite stays on... why? Thank you.
@grayfurnaceman
@grayfurnaceman 9 лет назад
EurekaRecycler If the pilot stays on with the thermopile disconnected, and the valve is not installed backwards, the valve must be replaced. The pilot safety is not working and could cause a fire. Resistance on that valve should be very low, perhaps less than 20 ohms. GFM
@EurekaRecycler
@EurekaRecycler 9 лет назад
grayfurnaceman This furnace looks old with only 2 wires on the valve. Would you know where I could get one of these valves? Do you ( if so how to ) retrofit/upgrade these components? Thank you!
@grayfurnaceman
@grayfurnaceman 9 лет назад
EurekaRecycler The replacement is quite complicated. Best left to the professional. If you insist on replacing it yourself, you can use this video: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-g8jMJIBVRGo.html Hope it helps. GFM
@jamiehenderson1797
@jamiehenderson1797 6 лет назад
Help... I just bought a house with a gas fireplace (LP). I have had no luck getting it to work. The unit has no label and no one will service it without knowing the brand so I am trying to do it myself. The main gas valve does not open. I jumped the wall switch and can hear the valve click, but nothing flows through. I bought a new valve and thermopile set but it behaves the same. I have a sit 820 nova mv. It has a magnetic safety valve that I don't think is opening. So gas pressure is good, wall switch is good, thermopile and thermocouple is new, main valve is new, pilot lights but does not stay lit and gas valve does not open. No propane smell as well. I am ready to spend $1000 for a new burner and log set but I keep thinking that this should work. House inspector took 30 minutes to get it started but the flame poured out a foot high from one location. Hasn't worked since.
@grayfurnaceman
@grayfurnaceman 6 лет назад
Well, If you send detailed pics to Grayfurnaceman@gmail.com I will try to help. GFM
@workingshlub8861
@workingshlub8861 8 лет назад
can you use a run a 24v style thermostat off a milivolt gas valve? your videos are very informative.
@buffalobilljohnston
@buffalobilljohnston 6 лет назад
depending on the technical specifications, some do both Voltage: 24VAC and 750mV Compatible: Yes. see Mfr #: 1C20-101 emerson or MFR #: 4PU51 dayton.
@DONALD1951
@DONALD1951 5 лет назад
No. Unless there is a relay in between.
@oabus
@oabus 7 лет назад
I have a royal rpt-50 oil fryer using propane. My question is does the gas valve adjust the fuel mixture?
@grayfurnaceman
@grayfurnaceman 7 лет назад
steven chandler The gas valve does not mix air with fuel. What comes out of the valve is pure propane. Air is mixed with the fuel in the burner. GFM
@oabus
@oabus 7 лет назад
thank you sir
@UltraHydrophobiccoat
@UltraHydrophobiccoat 3 года назад
Can you do a video to show the wiring diagram inside of gas valve? It is confused just see TH PG terminals. Also will white and red leads matter on which terminal should be connected? Thanks
@grayfurnaceman
@grayfurnaceman 3 года назад
I will put it on the list. GFM
@brandifarmer6474
@brandifarmer6474 Год назад
Why does my natural gas fireplace vent free insert thermostat work backwards
@ericat7422
@ericat7422 7 лет назад
Hi, my pilot is working just fine but when I try to turn on the flame with the light switch, it's not igniting. I called a fireplace pair company and they said I need to call an electrician. Is this an electrical problem? I want to be sure before I have an electrician come out.
@gavinyost9044
@gavinyost9044 7 лет назад
Erica T i have the same problem! and not sure who to call either.
@belindahalbert6089
@belindahalbert6089 9 лет назад
what would cause a propane fireplace to burn when you are lighting the pilot.. the burner also comes on.. it should not even be able to burn until you turn the nob from the PILOT position to ON position should it? Please help. thank you
@grayfurnaceman
@grayfurnaceman 9 лет назад
If the main gas comes on while lighting the pilot, the gas valve is leaking by. It needs to b e replaced. GFM
@belindahalbert6089
@belindahalbert6089 9 лет назад
grayfurnaceman it also will not kick off by the remote or manually the only way to get it on and off is to light it and then turn the on / pilot / off nob to off position
@williamm200
@williamm200 6 лет назад
Thanks so much.!!
@grayfurnaceman
@grayfurnaceman 6 лет назад
Welcome GFM
@jimbroni2651
@jimbroni2651 9 лет назад
I was cleaning my thermopile and a shop lite that had bare wires sent110volts through the thermopile, to gas valve model#36CO3U type433 and thermostat and fried all three,which I have replaced with new parts heres the Q.my wires are not color coded and during the trouble shooting process have know idea where the go also there are only two wires I bought a Honeywell RTH2300/RTH221 thermostat with 7 connection??? help
@grayfurnaceman
@grayfurnaceman 9 лет назад
jim broni Boy, you are unlucky. If you have only heat without cooling, all you need is 2 wires to the thermostat. One from the gas valve and one from thermopile. Hope this helps. GFM
@plsniper
@plsniper Год назад
So, where would I connect the white and red wires from the thermostat?
@grayfurnaceman
@grayfurnaceman Год назад
One wire to TH, the other to TH-PG to the other. GFM
@troquero54
@troquero54 10 лет назад
Question: My wife accidentally pull the TH PG wires off and I re-connect them. The problem is when I turn on the pilot successfully, the pilot turns off when I turn the heat knob to high on the thermostat. Any advise?
@grayfurnaceman
@grayfurnaceman 10 лет назад
Juan Rivera First, be sure all wire connections are tight. Next, you might send me a pic of the wiring that was broken. GFM
@thomascoolberth2648
@thomascoolberth2648 5 лет назад
Are these things used in gas fireplaces and the like ? Not in gas boilers/furnaces?
@grayfurnaceman
@grayfurnaceman 5 лет назад
The most common usage is in fireplaces and free standing heaters that may need to be used in power outages. As boilers and gas furnaces use 120 volt power, they are not used there. GFM
@pappabob29
@pappabob29 8 лет назад
Can two of the millivolt wall furnaces be controlled by one thermostat?? Is there a two pole thermostat so the signal from one furnace won't open a gas valve on another furnace that has no pilot?? Thank you
@grayfurnaceman
@grayfurnaceman 8 лет назад
There is nothing that I know of. It could be done if you have a low voltage control system using a relay. GFM
@jeffpowell860
@jeffpowell860 7 лет назад
I am having the same issue. I am looking at wiring it up to the "fan" relay. Just need to figure out the two relay contact points and Ill have a multistage setup :)
@matthewwegner5560
@matthewwegner5560 7 лет назад
But where does the half volt come from? is it kind of a ohm thing?
@grayfurnaceman
@grayfurnaceman 7 лет назад
The thermopile makes electricity from the heat of the pilot. GFM
@matthewwegner5560
@matthewwegner5560 7 лет назад
Thank you
@jeffpowell860
@jeffpowell860 7 лет назад
en.wikipedia.org/wiki/Thermoelectric_effect
@1stFlyingeagle
@1stFlyingeagle 2 года назад
Does it matter where red or white goes from thermopile to gas valve? Seen many videos and it is confusing. Is there a manufacturing spec on this?
@grayfurnaceman
@grayfurnaceman 2 года назад
No, the wires are interchangeable. GFM
@codyharris3741
@codyharris3741 Год назад
I have a monnessen gas fire place that uses a remote controlled thermostat and would like to put a wired thermostat to it is that possible on my set up
@grayfurnaceman
@grayfurnaceman Год назад
You would have to change all the controls. GFM
@itzaalmanza5512
@itzaalmanza5512 8 месяцев назад
Does this work for a deep fryer
@jeffharrison9318
@jeffharrison9318 9 лет назад
Wondering how to wire a fireplace gas valve that does not have low voltage connections on it? Thanks
@grayfurnaceman
@grayfurnaceman 9 лет назад
Jeff Harrison I need to know more info. By low voltage do you mean millivolt or 24 volt? GFM
@jeffharrison9318
@jeffharrison9318 9 лет назад
Looking to hook up a thermostat to a Polaris fireplace model PG 200-N with a serial # of 02149. Thanks
@mark1verses14and15
@mark1verses14and15 Год назад
Is there a way to trigger the wall switch in the event of a power outage where the fire place has not "battery accessory"? Seems like you could use a 9 volt battery and tap the wall switch wires leading to the fireplace. Or something similar - in an emergency.
@grayfurnaceman
@grayfurnaceman Год назад
This all depends on the system. Some are set up with a manual switch that will operate the burner without power. It may be located under the access panel below the burner assembly. Merry Christmas GFM
@mark1verses14and15
@mark1verses14and15 Год назад
@@grayfurnaceman First - Merry Christmas (see Galatians 4v4-5) Second - thank you for the response Third - Seems a manual switch would still need some power - no? What I have: Heat-n-Glo Model SL-550TR I looked and found the manual switch - it works. I see the "wall switch" is the alternative to the "manual" switch. (We do not have a remote.) What happens when the manual switch is turned on/off? Opens the gas valve? Needs no electric (even milli-volts worth)? Thanks again and look forward to your response. It is 22 degrees F below windchill and -1 degree F where I reside in the mid-west.
@grayfurnaceman
@grayfurnaceman Год назад
@@mark1verses14and15 I believe that unit is millivolt operated. The switch inside the unit is in parallel to the wall switch and either should operate the fireplace. The fan will not operate but it will heat. Merry Christmas GFM
@mark1verses14and15
@mark1verses14and15 Год назад
@@grayfurnaceman Thanks for your attention and Merry Christmas! Isaiah 53
@paulk7895
@paulk7895 Год назад
So if i have dexen 6003ks millivolt and gas fireplace without the fan, then I don’t need a power hook up? I can hear gas coming but very slowly and when i try to light i see a small spark but doesn’t light up. Is this indication of a bad or clogged valve? It hasn’t been used for a decade if ever was.
@grayfurnaceman
@grayfurnaceman Год назад
If you are trying to start it with a piezo ignitor, (you press a red button for spark), you may simply have air in the gas line. Just keep doing it until it lights the pilot. GFM
@paulk7895
@paulk7895 Год назад
@@grayfurnaceman thanks, i will try that
@derrellw5685
@derrellw5685 5 лет назад
Great videos👍👍👍 What is the black wire connected to th/pg?
@grayfurnaceman
@grayfurnaceman 5 лет назад
It connects the thermopile to the pilot safety solenoid. GFM
@derrellw5685
@derrellw5685 5 лет назад
I had to replace my aquastat and noticed that the wiring diagram for the millivolt gas valve says I can disconnect the pilot safety solenoid line from the th/pg terminal and connect it to a 'supplemental high limit switch'. Is the aquastat considered a 'shls'? When I wire the aquastat the traditional way my pilot and burner wont stay lit. Its a brand new millivolt gas valve and aquastat.
@josea2462
@josea2462 8 месяцев назад
Question does it matter which PH wire we use . Can we switch the white and red wire without any problem ? Since they are both PG ?
@grayfurnaceman
@grayfurnaceman 8 месяцев назад
Those wires are interchangeable. GFM
@gfdfperte4248
@gfdfperte4248 8 лет назад
What is the Millivolt volt reading when checked with a meter for a good thermo unit.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Gfdf Perte If the circuit is open (thermostat open), 4 to 600 MV. Closed thermostat, 125 to 250. Hope this helps. GFM
@gfdfperte4248
@gfdfperte4248 8 лет назад
yes thanks very much. Closed thermo is when it is heated. Thanks
@DONALD1951
@DONALD1951 5 лет назад
600-750 milivolts open circuit.
@ratoneJR
@ratoneJR 7 лет назад
In a milivolt system, is there a thermocouple and a thermopile? Or... does the thermopile do the job of both parts?
@grayfurnaceman
@grayfurnaceman 7 лет назад
No and yes. To further explain, some millivolt systems, meaning any system that uses only millivolt controls for the operation of gas controls, will use the thermopile for both operation of the main gas and pilot safety controls. However, some systems use both. The thermocouple is used for the pilot safety. The thermopile is used to power the main gas. Hope this helps. GFM
@ratoneJR
@ratoneJR 7 лет назад
grayfurnaceman I was worried you might say that. lol. Thanks for the info.
@dtrrtd774
@dtrrtd774 6 лет назад
How much current does the gas valve require to remain actuated? I assume the main gas valve requires higher current than the pilot shutoff valve.
@mostlikelywedoitservices6926
@mostlikelywedoitservices6926 2 года назад
Gray where is a good supply house to order Fireplace gas valves from and universal pilot assy?
@grayfurnaceman
@grayfurnaceman 2 года назад
I don't have any trusted sources. Your local HVAC dealer will probably be able to help. GFM
@mostlikelywedoitservices6926
@mostlikelywedoitservices6926 2 года назад
Gray thank you for responding back. Happy New Year.
@Orrphan
@Orrphan 6 месяцев назад
So the red is the common dc connection? Older thermopile I’m removing from a Williams and replacing with a 700 robert Shaw valve and is giving reading of red wire being negative. My new thermopile is reading red as positive. What gives?
@grayfurnaceman
@grayfurnaceman 6 месяцев назад
Polarity is not an issue for these components. It will work either way if you wire it in the way the old one was. GFM
@Orrphan
@Orrphan 6 месяцев назад
Thank you for prompt response.I noticed it works either way and kinda figured with no polarity markings. I know AC will work either way, even though it doesn’t make it right to reverse polarity. I was just blown away how old thermopiles red wire is negative. I’m just going to put positive lead on piggybacked terminal with thermostat wire. Thanks again for great vid.
@Daledavispratt
@Daledavispratt 5 лет назад
I searched for the next part of this series..did you post it?
@grayfurnaceman
@grayfurnaceman 5 лет назад
I guess I forgot it. It is posted there now. Thanks for the update. GFM
@Barrymacockkiner3050
@Barrymacockkiner3050 Год назад
How would would one turn on the gas fireplace when the pilot light is lit but only standing, in a power outage. Mine is a multi volt system as well.
@Barrymacockkiner3050
@Barrymacockkiner3050 Год назад
It’s also on a switch.
@grayfurnaceman
@grayfurnaceman Год назад
@@Barrymacockkiner3050 There is also a switch in the control center under the fireplace. Merry Christmas GFM
@tubalcain1
@tubalcain1 5 лет назад
I need some desperate help here please … I have an Empire GWT-35-2 with an R5245 valve system. A few days ago I started up the system again for the new season by lighting the pilot light and turning the unit on. No problems starting up however the unit will NOT shut off. It stays on and the only way to turn it off is by turning the main gas valve off. I have a brand new thermostat and a brand new thermopile(generator)…. I have no clue what could be happening. I have never had this problem with this unit in the past 14 years. Any suggestions?
@grayfurnaceman
@grayfurnaceman 5 лет назад
If there is no power to the main gas valve, and the burner is still on, the gas valve has failed. GFM
@tubalcain1
@tubalcain1 5 лет назад
@@grayfurnaceman Forgive me for my ignorance but what do you mean by "power to the gas valve"? The only wires attached to the valve are the 2 (white and red) from the thermostat and 2 from the thermopile.. plus 1 from the limit switch. I have the thermostat on the lowest setting when I light the pilot however the burner kicks on immediately when it's lit... very strange. Is it possible I have the wires in the wrong place? Possibly the limit switch is bad?
@tubalcain1
@tubalcain1 5 лет назад
I purchased a new main valve and installed it... the unit is doing the same thing. The burner will go on as soon as I light the pilot. Could a bad limit switch be causing this?
@grayfurnaceman
@grayfurnaceman 5 лет назад
Try this easy test. Remove one of the wires (not the thermopile). If the burner stops, there is a problem in the wiring or thermostat. GFM
@tubalcain1
@tubalcain1 5 лет назад
After days and days of trying to figure out what was going on with my gas heater I FINALLY figured it out and my house is warm and cozy again!!!!! It turns out that the 2 wires from the thermostat connecting to the main valve were badly brittle and falling apart. the two wires were touching each other close to where the outer shield was stripped. I ended up cutting about 8 inches of wire completely off because the shielding was just falling apart and brittle (from the heat I guess)… Good thing I had plenty of extra wire to pull from the wall or I would have had to splice another piece. So my question NOW is this common with thermostat wire getting brittle like this... Is there some sort of protection from the extreme heat that I can use so this wont happen again? Heat resistant wire wrap of some sort?? Thank you grayfurnaceman for your suggestions!
@RFULCHER1
@RFULCHER1 4 года назад
Hi How do I connect a three wire thermostat wire to my gas wood stove so it powers the thermostat (nest) Thanks
@grayfurnaceman
@grayfurnaceman 4 года назад
I would have to see the furnace diagram to be able to help. GFM
@RFULCHER1
@RFULCHER1 4 года назад
Would a photo of the hook up on the stove help If so how do I send it to you Thanks for your help
@grayfurnaceman
@grayfurnaceman 4 года назад
@@RFULCHER1 You can try. Send to Grayfurnaceman@gmail.com GFM
@cookytrix
@cookytrix 6 лет назад
i know this vid is old but for what i wanna do, i cant find anything. i would like to have a switch in my living space that turns my hot water heater up and down. its a long walk outside to the heater and it doesnt need to be on high all the time. is there a way to run a wire or something? or maybe a special thermostat or remote something or other? its a 15 year old gas unit. thanx
@grayfurnaceman
@grayfurnaceman 6 лет назад
Not unless you have considerable skills in electrical and gas controls. GFM
@cookytrix
@cookytrix 6 лет назад
i have some. dont know what "considerable" means exactly. my dad was general contractor and ive been in all phases of construction since 1982. is there a special device or my existing contol needs to be modified?
@grayfurnaceman
@grayfurnaceman 6 лет назад
Give me the model number of the heater. GFM
@cookytrix
@cookytrix 6 лет назад
Unitrol - Robert Shaw 66-184-335 R110RTSP is the control info. i live in a cold climate and the model info is wrapped under two insulative jackets and tape. sorry if this control info isnt enough but the jackets come off as a last resort. thank you for your time gary :)
@grayfurnaceman
@grayfurnaceman 6 лет назад
There is no way to make that control work from a distance. All temp control is inside the control. GFM
@myron215genus
@myron215genus Год назад
I just replaced the valve but when it calls for heat I hear the click but the pilot go’s out
@grayfurnaceman
@grayfurnaceman Год назад
You probably have either a thermopile that is weak or not covered by the flame or you have a short in your wiring. Be sure your wiring follows the diagram. GFM
@tasawarahmed7200
@tasawarahmed7200 2 года назад
need me some tharmoncopil do u help me???
@wisconsinbush2940
@wisconsinbush2940 3 года назад
If I have a millivolt gas valve. Do I have to use a millivolt thermostat? Or can I use a regular heat only thermostat?
@grayfurnaceman
@grayfurnaceman 3 года назад
The millivolt thermostat will provide anticipation where the 24 volt one will not. That means you will have wider temp variations in the structure. GFM
@wisconsinbush2940
@wisconsinbush2940 3 года назад
@@grayfurnaceman Temp variations as far as set points on the thermostat fluctuating from set point to shut off?
@grayfurnaceman
@grayfurnaceman 3 года назад
@@wisconsinbush2940 Meaning wider swings in temp of the structure. A little colder when it starts, then a little warmer when shuts off. Probably 3 to 4 degrees F. GFM
@wisconsinbush2940
@wisconsinbush2940 3 года назад
@@grayfurnaceman Correct.
@xiaojie895
@xiaojie895 4 года назад
Anyone can explain to me why some pilot assemblies have thermocouple only, some have thermopile only and some have both of them???? Thanks
@grayfurnaceman
@grayfurnaceman 4 года назад
In many cases, the thermopile will not shut down the pilot safety switch within the required 3 minutes after pilot light outage due to its high output. The Thermocouple will shut down. GFM
@xiaojie895
@xiaojie895 4 года назад
@@grayfurnaceman Thank you sir
@B640000cg
@B640000cg 9 лет назад
How a gas valve works
@angelroman7314
@angelroman7314 9 месяцев назад
Ty
@jimbroni2651
@jimbroni2651 9 лет назад
again ,my two wires that go up to the thermostat are not color coded they are both black one is connected to the TH-GP terminal and the other is wire sent to the combination control and then back to the TH terminal so at my thermostat both wires are black and have been removed without labeling (helpful brother)which wire goes to the TH and which goes to the TH-GP terminal, you said the red is always return so that should go to the TH and the white should go to the TH-GP??? by the way my gas valve is the same as in your video... my luck has manifested in other ways as in I always pick losing lottery numbers thanks GFM
@grayfurnaceman
@grayfurnaceman 9 лет назад
jim broni With the 2 wires, it makes no difference. I should have explained better. Your thermostat appears to operate off of its batteries, so it does not need a power source. GFM
@itsmetheuglykid
@itsmetheuglykid 3 года назад
I need to know what that black wire is.
@grayfurnaceman
@grayfurnaceman 3 года назад
I could tell you, but then I would have to kill you. lol It operates the pilot safety valve. GFM
@itsmetheuglykid
@itsmetheuglykid 3 года назад
@@grayfurnaceman lol ya I ended up finding it in the comments...prolly shoulda tried that first. My neighbors fireplace and pilot light goes out when I wiggle this wire. The mV on the thermopile looked good. That particular fireplace doesn't have a thermocouple...does it sound like a bad safety valve? I can hear it click when it shuts the gas off. Thanks for the quick witty response btw 😁 you're video is still helping people almost a decade later 😉
@grayfurnaceman
@grayfurnaceman 3 года назад
@@itsmetheuglykid First, I would be sure the push on connection is tight. If it still drops out, replace the valve. GFM
@tselinsky6452
@tselinsky6452 3 года назад
Millivolt is such a genius system, makes me wonder why we've moved away from them. Who wants to be cold when the power goes out?
@grayfurnaceman
@grayfurnaceman 3 года назад
The problem with millivolt systems is voltage drop. With voltage that low, any poor connection will stop the unit from functioning. You are also stuck with natural air flow. No fan to move the air. GFM
@tselinsky6452
@tselinsky6452 3 года назад
@@grayfurnaceman interesting, because I just had to replace a thermopile and when I took it off, the connection was obviously the issue - the wire was poorly attached. But honestly if one has steam heat, you can't beat having heat when the power goes down, like during a blizzard.
@obedb093
@obedb093 6 лет назад
What does TH stand for?
@grayfurnaceman
@grayfurnaceman 6 лет назад
It is the thermostat connection. GFM
@tasawarahmed7200
@tasawarahmed7200 2 года назад
plzz help me
@grayfurnaceman
@grayfurnaceman 2 года назад
What is your question? GFM
@benjaminkelly9772
@benjaminkelly9772 Год назад
U forget ur high limit?😮
@mountainviews5025
@mountainviews5025 3 года назад
Why would you be eating while doing a video it's hard to understand what you say
@TheColtl45
@TheColtl45 4 года назад
Geez stop smacking your lips....
@chen-Po
@chen-Po 2 года назад
Don’t know what you are talking about.
@lavellharris4998
@lavellharris4998 4 месяца назад
Talk too much and don't get to the point
@stevesund6293
@stevesund6293 8 лет назад
Is there a way to run the gas fireplace when the pilot is lit and the power is out? I have a switch connected to the TH and PG (above) which lights the fireplace. I was told when the power goes out I can not use the switch to turn on the fireplace.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Steve Sound Yours sounds like its a thermopile system. If so, the unit will run normally without power. If there is a fan, it won't work. GFM
Далее
Grayfurnaceman makes sand burn
2:48
Просмотров 10 тыс.
Наше обычное утро 💕
00:42
Просмотров 914 тыс.
Pitco Millivolt Troubleshooting
10:07
Просмотров 236 тыс.
How the fireplace thermopile system is wired
4:30
Просмотров 573 тыс.
The simple check of the gas valve
8:46
Просмотров 1 млн
Part 3 80% Gas Furnace ( wiring & IFC )
34:23
Просмотров 28 тыс.
Brilliant Tips and Ideas You Can Easily Do at Home
8:12
Millivolt Valve for Remote Control and Wall Switch
12:14
Thermostat Wiring at Control Boards
14:53
Просмотров 57 тыс.
🥹Он герой (shawn_cnhk on IG)
0:15
Просмотров 3,8 млн