Тёмный

Generator fail to start | diesel generator Common problems | crank fail | Fail to stop  

Power Learning  channel
Подписаться 61 тыс.
Просмотров 12 тыс.
50% 1

Опубликовано:

 

2 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 43   
@mesumbearmstrong1301
@mesumbearmstrong1301 Год назад
Thanks very much,i wish this teaching should go with a video sir,so can know the relay and fuses controlling the solenoid
@MollaAlem-s8y
@MollaAlem-s8y Год назад
Model 1506A perkins generator 250 kva there is also ECU crank but not starting what the problem?
@beleteabiye6203
@beleteabiye6203 8 месяцев назад
THE generator show governer alar it is not startes when i make start will near to start and then will stop, what i will do?
@DieselGeneratortraining
@DieselGeneratortraining 8 месяцев назад
What is the model of Generators
@Mohamadmouatasim90
@Mohamadmouatasim90 Год назад
Thank you very much 🥰 Why "failed to stop " is related to oil pressure sensor instead of the Solenoid,?
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Great point!
@alastairwaters9114
@alastairwaters9114 Год назад
Majority of generator controllers use the oil pressure switch to detect if engine is running, so if you have faulty oil pressure switch then the controller might expect to see that switch open when we shut off engine but if its closed then the controller is still thinking that engine is running. Simple
@muflihmuslih9979
@muflihmuslih9979 3 месяца назад
Sir our Smartgen operating or ranking start fiw time quickly buzzer alarm coming & outermatic generator stop how check sir i need instructions thanks
@GiftSilaseze
@GiftSilaseze 23 дня назад
i have follow you for a good time what i need is certification to show that i have attended your training , thank you
@hayleyesuskassa6473
@hayleyesuskassa6473 6 месяцев назад
How to check fuel relay fuel selonoid practically ?
@teehashashth
@teehashashth Год назад
I had 6010 controller with fail to stop alarm . I change 3 vdo10 bar oil pressure sensor but still the same condition... suddenly it fail to stop gone and then I can run it. After 5 second again stop and show stopping and cannot be reset . After timer goes out I had fail to stop again .... what shall I do?
@Mechanics_world007
@Mechanics_world007 Год назад
Thank you for sharing your experience about gen set troubleshooting my dear friend
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Ur welcome
@FrederickNuqui-s4x
@FrederickNuqui-s4x Год назад
Mebay 25kva sir they change after that start is o.k but a few second will off.what is the problem sir thanks
@-wheeling9509
@-wheeling9509 Месяц назад
Thanks brother
@dipupandit4156
@dipupandit4156 Год назад
your dg why dish pley sow the. run feedback fail. please really caterpillar have DG. 500 kV
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Which engine C18 and which controller type
@kishorkumarbaroriya5459
@kishorkumarbaroriya5459 Год назад
Hi, if engine failed to start so more chaces of MPU not sence the RPM and air trapped in fuel.
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Many aspects
@NkosinathiNotununu
@NkosinathiNotununu Год назад
Hi sir , what happens if the generator is starting via a relay and through a direct wire but does not run on its own it requires one to hold accelerator and once you let go of the accelerator it then switch itself off. I also get the fail to stop alarm. The generator doesn't not start via the control panel. . Where should I start checking? Thank you
@zahidhassan3314
@zahidhassan3314 5 месяцев назад
Sir pcc module ki viedo banye
@exclusivesafar
@exclusivesafar Год назад
Good job 👍
@gibsmhel5579
@gibsmhel5579 Год назад
Sir i have problem my generator start to fail then i direct the solinoid it its running i change the realy then start running not also running
@DieselGeneratortraining
@DieselGeneratortraining Год назад
U need expert inspection
@m.habdullah8052
@m.habdullah8052 Год назад
Thanks 👍
@muhammadjunaid9332
@muhammadjunaid9332 Год назад
Dear sir,In emergency how we can bypass oil pressure sensor..
@alastairwaters9114
@alastairwaters9114 Год назад
You shouldn't have to by pass it? Depends what controller you have but when cranking remove the oil switch wire and that should by pass it but you shouldn't bypass it unless you want to see metal lol
@honoratojrogoc4535
@honoratojrogoc4535 Год назад
Thank you my friend watching from isarael
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Thank you too
@magisamarcy1012
@magisamarcy1012 Год назад
Actuator not working that's why engine fail to start connection is not normally works
@magisamarcy1012
@magisamarcy1012 Год назад
That's my problem my friend i hope you give some tips for me to fix my problem thanks
@aliaditv4122
@aliaditv4122 Год назад
Sir guidelines chaiye
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Send your inquires on Info.powerlearning@gmail.com
@nalkamannalkaman4937
@nalkamannalkaman4937 Год назад
Super explained sir thq
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Thanks
@mandaragat3395
@mandaragat3395 Год назад
Thank you my friend...
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Ur welcome
@malikshahid4859
@malikshahid4859 Год назад
😅😅😅😅😅
@DieselGeneratortraining
@DieselGeneratortraining Год назад
😁😁😁😁😁
@sarathiv.s4192
@sarathiv.s4192 Год назад
Failed to start, low oil pressure light indicated
@mauriceamollo8237
@mauriceamollo8237 Год назад
While changing oil filter,is a must to fill it with oil before installation just like fuel filters?
@kewalsingh9934
@kewalsingh9934 Год назад
pls make in ATS foult video
@DieselGeneratortraining
@DieselGeneratortraining Год назад
Ok noted always comment what u want to learn about
Далее
Cummins Generator 500kva - Engine Hunting Problem
13:05
Diesel generator maintenance in Tamil-A B C D Check
16:38
Generator Starting problems and troubleshoot
7:44
Просмотров 47 тыс.
Genset failed to start (Cummins 100kva)
6:32
Просмотров 9 тыс.
Engine failure to start due to a bad  Relay  #perkins
8:12