just as the title says, modified the exhaust on my generator so that I can run the genny inside the shed, and vent all exhaust gasses outside. and it runs everything in my house except for my stove.
Perfectly legal: Pertinent reference data: Article 705.NEC702.6 contains an exception to the transfer equipment requirement: “Exception: Temporary connection of a portable generator without transfer equipment shall be permitted where conditions of maintenance and supervision ensure that only qualified persons service the installation and where the normal supply is physically isolated by a lockable disconnecting means or by disconnection of the normal supply conductors.” The term as defined in the 2011 NEC reads as follows: Qualified Person. One who has skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the hazards involved. (no degree or certification necessary, just basic knowledge training available everywhere) 110.25 Lockable Disconnecting Means: Where a disconnecting means is required to be lockable open elsewhere in this Code, it shall be capable of being locked in the open position. The provisions for locking shall remain in place with or without the lock installed. (you can't lock it with a chain or some other thing that is all removed when unlocked, the lock has to be a feature of your breaker box and be able to lock the main breaker open. You CAN legally turn an outlet into a generator inlet through your panel and do so without an interlock or a transfer switch if your main breaker or box has locking function, provided its a temporary connection of a portable generator.

Авто/Мото

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@charlesboston1
@charlesboston1 2 года назад
if your going to back feed your house , make damm sure the main breaker is turned off to prevent energizing the main grid and endangering people lives
@onemansjunk1252
@onemansjunk1252 Год назад
I have a similar set up. But I feel hot air coming from around the exhaust. Is that normal or is my setup not air tight
@AaronsAutomotive
@AaronsAutomotive Год назад
As long as you don't smell any exhaust fumes you should be fine. Mine let's off hot air out the back as well, the fan that built into the generator electric side moves air from its internal fan to keep it from ovr heating odds are that what you are feeling. If there is no odor of exhaust you should be good.
@onemansjunk1252
@onemansjunk1252 Год назад
@@AaronsAutomotive yeah no odor. And when I put my combustible fumes meter it doesn't detect anything. When I put my meter at end of pipe it whales. My carbon monoxide detected doesn't pick anything up. It just worries me cause I felt hot air about 3 inches left and right of the pipe. It does feel like a warm air fan type wind
@360kidmac9
@360kidmac9 Год назад
Title picture shed is not the same shed in video
@michaeltang7238
@michaeltang7238 2 года назад
Would you like to test generator inlet box ?
@AaronsAutomotive
@AaronsAutomotive 2 года назад
Michael I would LOVE to test a generator inlet box. You can email me at Ahainstocky@gmail.com for any inquiries 😀
@TheAmericanCelt
@TheAmericanCelt Год назад
Among the other redneck, bushcraft, jerry rigged mayhem we could talk about... Why didnt you go out the side of the shed for the exhaust? Would have been alot more weather resistant than the homemade water fall you created by going through the roof.. Just sayin, Just sayin...
@jrose7849
@jrose7849 2 года назад
Dangerous and usually illegal way to connect a generator. Does the proper connection cost more? Yes. Is it worth your life and the health and safety of the hydro workers working hard to restore your electricity? Hell yes.
Далее
90% Don't Know About This Fatal Generator Connection
11:17
Will a Car Muffler Make a Generator Quiet?
10:40
Просмотров 2,4 млн
Generator Backfeeding to a house for dummies 101
11:58
Просмотров 244 тыс.
Will a car muffler make a generator any quieter
5:17
Просмотров 699 тыс.
Chinese diesel heater test IN WINTER! (will it work?)
19:39
Forced-air Furnaces: The What, Why, and How
22:05
Просмотров 1,3 млн
Weld On Exhaust Adapter fittings for Generators
2:19
Просмотров 2,4 тыс.
Generator Shed Build
23:08
Просмотров 46 тыс.
How to make a generator quieter - 9 Ways That Work!
15:09
что за звук?
0:15
Просмотров 3,8 млн