Goodman A/C NOT COOLING! More Than Just The Obvious! 

Jeff’s HVAC Adventures
Подписаться 7 тыс.
Просмотров 8 тыс.
50% 1

In this video we take a look at a second floor Goodman Central A/C system that isn’t cooling AT ALL! Lets goooo!
Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!
WisePro 1000v Insulated Screwdriver set: amzn.to/43nBUV6
Avhrit Electric Pipe Cutter amzn.to/4e6YDKb
Discount code to save 10% : 104H1TFB
TOPTES Combustible Gas Leak Detectors.
4 TO CHOSE FROM!
PT210S
amzn.to/3QSHJEu
Discount Code: GSYQFS4Z
PT299
amzn.to/3R38JlS
Discount Code: 4A3HH88Q
PT199
amzn.to/3M5kTYs
10% off with code: N83SX3Q6
PT520B+ Professional Gas Leak Detector amzn.to/494fISD
10% off with code: R98D8JH8
TOPTES CT-300 CO Detector: amzn.to/499s23E
Discount Code: 953OHRKL
Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!
amzn.to/3KwRw0m
Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
Tesman TN-213 NCV Tester amzn.to/3rVZY3j
10% off with code: FJDYR4W3
Topdon Thermal Camera for Android amzn.to/46Wldkf
Topdon Thermal Camera for iPhone amzn.to/46Twvpu
WisePro Tradesman Backpack:
amzn.to/4912DYW
If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!
Support the Channel with a Super Thanks or
PayPal: ​⁠@JeffsHVACAdventures
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures
Like and Subscribe!
Questions, comments or to just say Hi, email me
jeffshvacadventures@gmail.com

Опубликовано:

 

5 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 58   
@agostinodibella9939
@agostinodibella9939 3 месяца назад
Nice job. I have one of the more recent Rheem condenser units where one screw on each side lets you remove the four side covers for easy cleaning. It has been working great for six years now.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Yea I love that Rheem design.
@46fd04
@46fd04 3 месяца назад
If there is an A-frame style evaporator inside the furnace duct work, pull it out and take a look under it. If the customer has a dig or cat, there could be a matt of animal fur stuck to the underside of the evaporator.
@bills6946
@bills6946 2 месяца назад
When you replace a capacitor, always check the amperage of the fan and compressor afterwards against nameplate amperage. Sometimes a bad cap will burn the windings of the fan or compressor. If it does, the amperage will be higher than nameplate, indicating you probably have to replace the motor or compressor.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 месяца назад
Good stuff.
@markcotter2355
@markcotter2355 3 месяца назад
nice intro mix. agree with ya , you got to have a hot enough flame.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Thanks
@woodystokes1543
@woodystokes1543 3 месяца назад
Nice work and good information 😊
@chrissipple1018
@chrissipple1018 3 месяца назад
Remember sweating suction line is caused by what ever the Dew Point is. If it sweat's it sill can be over or under charge.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Good point
@Wrenchmonkey1
@Wrenchmonkey1 3 месяца назад
How much did you charge those suckers for that half-assed cleaning?
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
What it costs.
@CaryS2
@CaryS2 3 месяца назад
I’m confused, wouldn’t a dirty condenser result in a low subcooling? And subsequently, cleaning the condenser would help to cool the refrigerant more and increase the subcooling. What you said sounds backwards from that.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
No low Subcooling would result in low refrigerant charge or wide open metering device. High Subcooling could be dirty condenser, over charge, restriction in refrigeration circuit.
@CaryS2
@CaryS2 3 месяца назад
I’m not trying to be difficult, I’m just trying to understand. It just doesn’t make sense to me that if the condenser was extra dirty, say packed with mud, then the heat exchanger would be very ineffective so it should not be able to cool the refrigerant below the saturation temperature very much at all. I would think that would be called low amount of sub-cooling. And if the condenser was perfectly clean with max amount of pristine surface area for heat transfer, that seems like it would be able to cool the refrigerant to the maximum amount possible thereby achieving a large amount of sun-cooling below the saturation temperature.
@corruptedbrain6
@corruptedbrain6 3 месяца назад
common and run would read OL if it was out on thermal.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
🤙
@Eddy63
@Eddy63 3 месяца назад
Excellent advice Jeff ... Thx
@beerbrewer7372
@beerbrewer7372 3 месяца назад
I'm a noob so forgive my stupid question: how can the compressor thermal switch be open when the capacitor is pretty much dead?
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
The dead cap would cause the compressor to go into thermal OL. When the unit has a dead cap, every time you hear that buzz for 1-2 seconds… the compressor is trying to start and then going into thermal OL. The OL switch is internally installed on AC compressors.
@beerbrewer7372
@beerbrewer7372 3 месяца назад
@@JeffsHVACAdventures Thanks for taking the time to answer my question!
@craigmix4760
@craigmix4760 Месяц назад
filter dryer on wrong way
@JeffsHVACAdventures
@JeffsHVACAdventures Месяц назад
🤔
@martinheatingcoolingmartin4693
@martinheatingcoolingmartin4693 3 месяца назад
Are you Flat Rate? Customer approved the work? I was but went back to T&M. I’m probably leaving money on the table. But I do feel to do a cap, clean test & check I didn’t have to spend the extra time to get anything approved. I can do all that within the first hour plus minimal parts but of course I’m definitely not making as much.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
We just switched to flat rate this year. But it’s our company policy anything over $300 need approval from the customer. Which is most tickets.
@cengeb
@cengeb 3 месяца назад
Whia insulated, more better
@DabblelyDiddly
@DabblelyDiddly 3 месяца назад
my air handler quit one day, so i opened it up.. seeing as i already do this to change the filter.. and noticed the cap was just cryin down the blower case. ordered one and installed it, its been 7 years now.. so yeah it was just the cap.
@dc6233
@dc6233 3 месяца назад
That's just your air handler, so the cap only assists the indoor fan, that doesn't care if there's any refrigerant in the system or not, it just blows air. Whereas the compressor is affected by low or over filled refrigerant.
@joshstevens9826
@joshstevens9826 3 месяца назад
Hi sc and hi sh is a restriction, no way washing the coil fixed that
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
SC was a little higher than you’d like but definitely worked a whole lot better. Also had to let it run 15 or so min before numbers started normalizing. I Might have been being a little impatient
@nickmrt2670
@nickmrt2670 3 месяца назад
So is it fair to say replacing the filter/dryer fixes this? Thx
@FrenchBeefCDN
@FrenchBeefCDN 3 месяца назад
@@nickmrt2670only if it’s the filter causing the restriction. Measure across the suspected restriction, shouldn’t be more than 2-3•f refrigerant saturation temperature drop.
@phoenixhvac-r828
@phoenixhvac-r828 3 месяца назад
You advocate to not have tunnel vision and not just replace cap and go, but you didn't show any footage of you checking temperture split, condensate drain, indoor blower and cap etc...
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Some customers like to stay with you when you’re inside their home. I usually respect their privacy and avoid the weird questions when this happens and just not film. I have tons of other videos of me demonstrating the procedures you mentioned. Check them out 🤙
@sergiohernandez4163
@sergiohernandez4163 3 месяца назад
On my area we always wash the coils and check freon if we Replace any parts
@4Rascos
@4Rascos 3 месяца назад
​@@sergiohernandez4163definitely half ass job
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
@@4Rascosbecause if I didn’t film it, it didn’t happen right?
@4Rascos
@4Rascos 3 месяца назад
@@JeffsHVACAdventures you yourself said you didn't take the outside cover off because it was too much work. 😉
@cengeb
@cengeb 3 месяца назад
Damn, these things are loud and annoying. Mitsubishi mini splits spoiled me. Silence inside and out. heating and cooling, these noise makers are a disaster once you go Mitsubishi mini splits
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Right you are!
@leskeegan9033
@leskeegan9033 3 месяца назад
I had one for 4 years and replaced it with a Lenox which I had before and never looked back.
@corruptedbrain6
@corruptedbrain6 3 месяца назад
i always recommend tubros all the way. They are better. Also, you installed the capacitor incorrectly. Youre suppose to hide the label of the cap plus, recommend new contactors cause its happened to me where i leave and 2 months later that contactor goes out. I give the customers multiple options and let them decide you know
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Pretty sure you’re joking about the cap label but I didn’t want to run the bill up too high on the customer. I did mention it but They barely approved the work I did do.
@corruptedbrain6
@corruptedbrain6 3 месяца назад
@@JeffsHVACAdventures Im joking about the label 😂 good job though bro. I've learned as long as you gave them options just to cover your butt
@clintgray1623
@clintgray1623 3 месяца назад
So put in $60 turbos and you can get the proper size capacitor for less money , so you have to carry more capacitors on the truck Basically lazy techs not
@corruptedbrain6
@corruptedbrain6 3 месяца назад
@@clintgray1623 turbos
@lynnprince6635
@lynnprince6635 3 месяца назад
Guess you have not been zapped enough, working on a unit with power still to the contractor 😮
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Been zapped plenty. lol. Learn to be more careful. 😅
@BartlettTFD
@BartlettTFD 3 месяца назад
The camera work on this RU-vid video is not awful but close to it. Shots are way too tight👎
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Not a professional videographer. Just an HVAC guy showing what I find.
@angiespencer4156
@angiespencer4156 3 месяца назад
You call that quality lol
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Yes. I don’t film everything so if there was something you were expecting to see or hear in this video, I apologize for not filming it.
@happyyardservice2914
@happyyardservice2914 3 месяца назад
That should be a 45/5 not 40. Sus
@JeffsHVACAdventures
@JeffsHVACAdventures 3 месяца назад
Watch again friend. Zoom in if you have to. It’s a 40/5. 1:05
@happyyardservice2914
@happyyardservice2914 3 месяца назад
@@JeffsHVACAdventures Oh yeah, just never seen 40/5 for Goodman. I was like wait.. what. LOL
@AmandaHugenkiss2915
@AmandaHugenkiss2915 3 месяца назад
​@@JeffsHVACAdventuresdoes it cause any harm if a higher value cap is used, eg a 45 or higher where a 40 is specified?
@JeffsHVACAdventures
@JeffsHVACAdventures 2 месяца назад
@@AmandaHugenkiss2915 there won’t be any immediate damage. It can get you out of a jam. But the long term will shorten the life of the compressor.
Далее
5 Calls, One Sunday!  THEY JUST KEPT COMING!
29:20
Просмотров 7 тыс.
Air Conditioner Not Cooling What Will I Find?
21:59
Просмотров 44 тыс.
Two Disgustingly Clogged Condensate Drain Lines!
17:56
Просмотров 1,7 тыс.
HVAC Advanced: Triple Evacuation
6:54
Просмотров 11 тыс.
Goodman System Not Cooling Due to Major Issue | HVAC
14:59
HVAC No Cooling Service Call WORST HELICOPTER EVER !!
22:15
Forced-air Furnaces: The What, Why, and How
22:05
Просмотров 1,3 млн
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
Explaining Superheat and Subcooling to Your Apprentice!
14:14
Daiken death trap - How do people do stuff like this?!?
24:39