Why is my air conditioner not cooling? Here's why your Goodman air conditioner runs but does not blow cold air. On this video I show how the repair could be as simple as a bad hard start on your Goodman air conditioner. Although this is a Goodman air conditioner, this repair will fix most AC units of different brands.
Fieldpiece SMAN Gauges link: amzn.to/3rO1Czr
Capacitor Links
Be sure microfarads match your units capacitor.
45/5 capacitor: amzn.to/3gVBsHv
5-2-1- Hard Start Compressor Saver Kit Link- amzn.to/367jfA7
If you'd like to support the channel, you can do so by shopping for tools or whatever you need on AMAZON at no extra cost to you through this link,
amzn.to/3vC9PaF
Tools That Can Make You Easy Money: www.dirtymaintenancenation.co...
If I've provided any value for you and you'd like to donate $1.00 or more into my online tip jar, you can do so through this link, (all cards accepted)
squareup.com/store/dirty-main...
Friend me on Facebook! dirtymainten...
This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission at no extra cost to you. Lex Vance is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon .com
#propertymanagement #maintenancetechnician #multifamilyhousing #apartmentmaintenance #handyman #Tallahassee

Развлечения

Опубликовано:

 

13 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 82   
@LexVance
@LexVance 2 года назад
Tools That Can Make You Easy Money: www.dirtymaintenancenation.com/diy-tools-for-men/ Fieldpiece SMAN Gauges link: amzn.to/3rO1Czr Capacitor Links Be sure microfarads match your units capacitor. 45/5 capacitor: amzn.to/3gVBsHv 5-2-1- Hard Start Compressor Saver Kit Link- amzn.to/367jfA7 If you'd like to support the channel, you can do so by shopping for tools or whatever you need on AMAZON at no extra cost to you through this link, amzn.to/3vC9PaF If I've provided any value for you and you'd like to donate $1.00 or more into my online tip jar, you can do so through this link, (all cards accepted) squareup.com/store/dirty-maintenance-nation This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission at no extra cost to you. Lex Vance is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon .com
@sknight0391
@sknight0391 2 года назад
Ol" Lex has got those nerves of steel, he didn't even flinch when the other unit turned on! 💪😁✌️
@LexVance
@LexVance 2 года назад
👍😆👍 Thank you so much for Shannon!
@bennyhill3642
@bennyhill3642 Год назад
Lol I thought the same thing!
@theweekday1071
@theweekday1071 2 года назад
I'm a young tech only 24 years old and I'm learning so much from your videos. Keep up the great work lex
@LexVance
@LexVance 2 года назад
Awesome! I'm having a blast making the videos and helping any way I can. Thank you so much for watching Weekday!
@roberts1159
@roberts1159 2 года назад
Nice troubleshooting as usual. Thanks for sharing this video.
@LexVance
@LexVance 2 года назад
You're welcome Robert! Thank you so much for watching!
@FrantzB3472
@FrantzB3472 2 года назад
Good job Lex. I always learn something from you videos. Thanks for sharing
@LexVance
@LexVance 2 года назад
You're welcome Frantz! Thank you so much for watching!
@phillipgroom9187
@phillipgroom9187 2 года назад
Good job. Never seen one of those before myself. Good information, thanks for sharing. Be carful and stay cool.
@LexVance
@LexVance 2 года назад
Thank you so much for watching Phillip!
@edwardgarza5104
@edwardgarza5104 2 года назад
Hey Lex, you may know this, the potential relay that's with the start capacitor is a normally closed contact and is design to open the contract to take the start capacitor out of the circuit once voltage has been applied to the compressor for about one to 2 secs. And sometimes the potential relay is faulty and the relay never opens the contact which leaves the start capacitor in the circuit which would cause over amping on the compressor. Good way to test to see if the relay is working is to place your amp clamp around one of the wires going to the start capacitor and watch it to make sure the amps cut off once compressor turns on. If your still reading amps relay is not doing its job. Great video.
@LexVance
@LexVance 2 года назад
Right on Edward! I'm still learning this style as I've never seen these. Thank you man!
@edwardgarza5104
@edwardgarza5104 2 года назад
Yes sir, it's always good practice to replace the potential relay with the start capacitor, and not all potential relays are created equal the coil in the relays are size to match the compressor as they use reverse polarity from the compressor voltage to energize the relay. Their pretty cool relays on how they work once you know how they work. They used them all day long on single phase refrigeration condensers.
@rottiev264
@rottiev264 2 года назад
And just to add to that, you should read a high resistance through the coil, usually 2 and 5, and the NC contacts are 1 and 2 Nice work skid👍
@williamzelonis5606
@williamzelonis5606 2 года назад
Absolutely! Standard procedure is to change the relay if the start capacitor is defective.
@rpgoodwinjr15
@rpgoodwinjr15 2 года назад
Good job. Learned something about Goodman has a hard start kit on this particular unit and can cause the breaker to trip. Thanks for the tip.
@LexVance
@LexVance 2 года назад
You're welcome Robert! Thank you so much for watching!
@jaimegonzalez6926
@jaimegonzalez6926 2 года назад
Thank you learn something new every day bring some more videos we will watch them your ability to explain things good is what brings me back to your videos.
@LexVance
@LexVance 2 года назад
You're welcome Jaime! Thank you so much for watching!
@efman2k3
@efman2k3 2 года назад
Great video! Thanks for posting!
@LexVance
@LexVance 2 года назад
Thank you so much for watching Efrain!
@Deniz-hp1me
@Deniz-hp1me 2 года назад
bromen i gotta be honest you are the best , when i watch you i have to take notes literally ! on a notebook . so good at teaching wish my lead was as good about explaining . ugh terrible trainer ! good looking out broheem !!
@LexVance
@LexVance 2 года назад
Right on! So glad I can help. Thank you so much for watching Deniz!
@larrydotson324
@larrydotson324 2 года назад
Great vid Skid! Yup, it's been ridiculously hot and top it off with all of the rain.
@LexVance
@LexVance 2 года назад
Good to hear from you Larry!
@Eddy63
@Eddy63 2 года назад
Nice easy repair ... Nice looking complex your at ...
@LexVance
@LexVance 2 года назад
It's 3 years old. Still a baby. Thank you so much for watching Eddy!
@ScorpioandSebek
@ScorpioandSebek 2 года назад
Good job skid. I have a couple of hard starts but have never had to use them yet. Those straight cool systems seem a little more maintenance friendly than heat pumps
@LexVance
@LexVance 2 года назад
Yes they are. Now that I'm getting to know them, I really like them. Thank you so much for watching Scorpio!
@realSamAndrew
@realSamAndrew 2 года назад
Big money no whammy! Loves it!
@LexVance
@LexVance 2 года назад
👍😆👍 Lots of sick days watching that game show. Thank you so much for watching Sam!
@RayeSoCaLA
@RayeSoCaLA 2 года назад
I like that craftsman meter with the Cap function Bromie. Can’t stand how I gotta hit buttons multiple times on my UEI. Also left my Hotel engineer job to be a HVAC service tech. I enjoyed it but you’re right. No appreciation for pennies. They need to start dishing out the cheddar!
@LexVance
@LexVance 2 года назад
Amen! Good to hear from you RAYe!
@letslockit
@letslockit 2 года назад
Your the man!
@LexVance
@LexVance 2 года назад
Thank you so much for watching letslockit!
@gods959
@gods959 Год назад
Great tutorial thanks for sharing your knowledge blessing and more blessings to you and your family in Jesus name Amen
@LexVance
@LexVance Год назад
Thank you so much for watching Charles!
@bennyhill3642
@bennyhill3642 Год назад
Amen!!!
@derick441
@derick441 2 года назад
Those units are 7 to 9 subcool. I would suspect a issue with that txv with that superheat so high.
@LexVance
@LexVance 2 года назад
Right on. I'm still getting used to these units with the rotary compressors. They're a strange bunch. Good to hear from you Derick!
@tomtamichristoffersen1215
@tomtamichristoffersen1215 2 года назад
Nice fix Lex! Next weekend it’s someone else’s turn 😂😂
@LexVance
@LexVance 2 года назад
👍😆👍 Thank you so much for watching Tom!
@makeawish197534
@makeawish197534 2 года назад
Bro I am on call too men…. Last day is on Friday. I can’t wait..🙏
@LexVance
@LexVance 2 года назад
My last day is today. 🤞 Thank you so much for watching Juan!
@Justin-bb2hj
@Justin-bb2hj 2 года назад
Most Goodman that come with txv’s around here have hard starts from the factory idk. Btw if that hard start went bad they wouldn’t start.
@LexVance
@LexVance 2 года назад
It popped the breaker and wouldn't start. I've seen this before and once I change the hard start, it fixes it. I haven't heard from either of them again. One was 2 months ago. No call back. And this video was filmed a week ago and no call back. 🤞 Thank you so much for watching Justin!
@dyershvac5884
@dyershvac5884 2 года назад
Hey Lex! Hope you doing well bro and staying cool. I was gonna ask you if you have had a chance to try the sporlan smart probes yet?
@LexVance
@LexVance 2 года назад
No I haven't, but I would love to!
@dyershvac5884
@dyershvac5884 2 года назад
Dude those things are awesome!! I'm getting some asap. Damn things on back order here in GA for some reason
@johnsutter1497
@johnsutter1497 2 года назад
Does it matter what red lead goes on the hard start? Thank you have a good weekend
@SonicOrbStudios
@SonicOrbStudios 2 года назад
Nope, those two capacitor wires can be swapped All day
@LexVance
@LexVance 2 года назад
What David said. 😆 Thank you so much for watching John!
@adamedwards2435
@adamedwards2435 2 года назад
Lex, do you do any painting and flooring?
@LexVance
@LexVance 2 года назад
No, I don't have time. I chase AC's mostly due to it being Florida and hot 11 months a year. We have painting and flooring crews that do all that. Thank you so much for watching Adam!
@bennyhill3642
@bennyhill3642 Год назад
1 year old. Question, breaker flips when a.c. is turned off on the thermostat?
@LexVance
@LexVance Год назад
I'd need to be there for this head scratcher 🤔.
@dennisqwertyuiop
@dennisqwertyuiop 2 года назад
the resistor across hard start cap,,does it affect reading ?
@LexVance
@LexVance 2 года назад
That's a good question. 😆 I'm still new to this style and I'm not sure. Thank you so much for watching Dennis!
@lilmg4444
@lilmg4444 Год назад
So a system can get low on refrigerant without a leak?
@LexVance
@LexVance Год назад
I don't think so. Sometimes they're hard to find.
@frediszamora3800
@frediszamora3800 Год назад
Question lex why don’t you ever use a drill?
@LexVance
@LexVance Год назад
I do sometimes. I like the feel of screwdrivers. Thank you so much for watching Fredis!
@borys444
@borys444 2 года назад
Give her the ol gundy mama!!!!
@LexVance
@LexVance 2 года назад
👍😆👍 Thank you so much for watching Nicholas!
@josezarate4118
@josezarate4118 2 года назад
👊😎🛠🛠🛠👍
@LexVance
@LexVance 2 года назад
Thank you so much for watching Jose!
@westonhuffman7908
@westonhuffman7908 2 года назад
Well, Only if you couldn't do that job if the digital gauges were out of charge.
@LexVance
@LexVance 2 года назад
Thank you so much for watching Weston!
@donnierobertson3088
@donnierobertson3088 2 года назад
Ok
@LexVance
@LexVance 2 года назад
Thank you so much for watching Donnie!
@zueszues3178
@zueszues3178 2 года назад
By chase you wouldnt know why a heater turns on and doesnt turns off
@LexVance
@LexVance 2 года назад
Bad thermostat or sequencer intermittently gets stuck. I'd have to be there with my volt meter for this head scratcher.
@zueszues3178
@zueszues3178 2 года назад
My heater runs with the water heater the hot water gos threw a coil
@zueszues3178
@zueszues3178 2 года назад
I changed the thermostat but doesn’t work it still stays on
@LexVance
@LexVance 2 года назад
@@zueszues3178 Yikes. Maybe some low voltage wire touching somewhere and it's steady calling for heat. I've seen that too.
Далее
Fixing Another Goodman Air Conditioner
12:41
Просмотров 7 тыс.
Outside AC Unit Tripping Breaker (Bad Compressor)
15:08
ac compressor isn't  starting !
10:33
Просмотров 52 тыс.
Heat pump tripping the breaker diagnostic HVAC
7:59
Просмотров 12 тыс.
Outside AC Unit Not Running But Inside Is
8:57
Просмотров 396 тыс.