Join Rob and Ryan as they take out an internal Worcester combi and install an external Grant combi, in half a day. We hope you enjoy the vlog, and please subscribe for more content like this :-) Stay safe!

Опубликовано:

 

21 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@alimack5489
@alimack5489 9 месяцев назад
Top work chaps, used to do oil myself don’t miss it having to clean my tools after every job, and smelling like it used to get back up. Having said that they are built to last never seen or heard of modulating oil boilers before.
@BartonOilBurnerServices
@BartonOilBurnerServices 9 месяцев назад
Thanks for the great comment
@stuartadams9012
@stuartadams9012 10 месяцев назад
Nice work guys
@BartonOilBurnerServices
@BartonOilBurnerServices 10 месяцев назад
Thanks for the great comment
@owsi2297
@owsi2297 10 месяцев назад
Great video guys👏 what was exactly wrong with the Worcester Heatslave 2 ? I find them pretty bulletproof. Cheers
@BartonOilBurnerServices
@BartonOilBurnerServices 10 месяцев назад
Thanks for the comment. The jacket had totally rotted out. Not sure it had been power flushed last time and the prv had been weeping and they just kept filling it so low or no inhibitor. But yes i agree they are usually ok. Have a good weekenmd!
@martinwright7093
@martinwright7093 10 месяцев назад
Nice one. Is there a particular reason why you fit an external electrical isolator? Couldn't you just use the fused spur inside the house for isolation?
@BartonOilBurnerServices
@BartonOilBurnerServices 10 месяцев назад
Thanks for the comment. The reason we fit the isolator is for safe isolation when you work on it. It kills all lives to the boiler. It means you can work on the boiler even without the customer being at home and still isolate it correctly if required. Great question!
@paul_my_plumbs_uk
@paul_my_plumbs_uk 10 месяцев назад
Subscribed 👍🏿👍🏿 and CRACK ON team Barton 🎉🎉
@BartonOilBurnerServices
@BartonOilBurnerServices 10 месяцев назад
Great stuff ! Thanks
@chriscars3578
@chriscars3578 10 месяцев назад
Great boilers
@BartonOilBurnerServices
@BartonOilBurnerServices 10 месяцев назад
Totally agree as long as you maintain them correctly. Thanks for the great comment!
@jigsey.
@jigsey. 9 месяцев назад
My Firebird boiler was due to be serviced today, but after he opened it up .. he said it's proper knackered, he doesn't know hows it's working, but it is, just not efficient.. So I'm getting solar panels installed in December, I checked the company they also do grant vortex condenser oil boilers.. How do you think they compare to the firebird ones... Thanks
@BartonOilBurnerServices
@BartonOilBurnerServices 8 месяцев назад
Thanks for the comment. My opinion only, I would only fit a Grant Combi. If you keep on top of them they are ok. If i was to fit another make it would br firebird. Hope this helps
@ryanmoore363
@ryanmoore363 9 месяцев назад
Nice video! I fitted one 2 weeks ago but having issues just with the heating.. have you had problems ever with the heating pump relay?
@BartonOilBurnerServices
@BartonOilBurnerServices 9 месяцев назад
Hi. There is no relay as such on the later combis. We have had a run of the circulating pumps nw. you can tell as the red and orange lights are both on on the pump. Hope this helps?
@ryanmoore363
@ryanmoore363 9 месяцев назад
@@BartonOilBurnerServices the hot water pump works fine, the heating one just won’t engage for longer then a second, even when pressing the service button.. tried another pump from my van and doing the same.. no air in system etc.. someone said it might be the non return valve after the pump so will check that tomorrow.. weird one as never had this issue before
@BartonOilBurnerServices
@BartonOilBurnerServices 9 месяцев назад
@@ryanmoore363 I dont think it will be that tbh. if you email me your number i can call you tomorrow and try help if i can? info@bartonoilburnerservices.co.uk
@andrewwhitnet3557
@andrewwhitnet3557 3 месяца назад
Hi,thanks for the videos. I'M Converting to oil frim sollid fuel añd am concidering where ro site the oil tank.Can you tell me minimum height of tank outlet above floor levell where boiler will sit please.Thanks,
@BartonOilBurnerServices
@BartonOilBurnerServices 3 месяца назад
Hi. Thanks for the comment. The tank height does not matter. If the oil pump is lower than the bottom of the tank that is good. If not then you need a tiger loop near to the boiler. we have a vlog on that so it will explain it for you, Have a good weekend!
@andrewwhitnet3557
@andrewwhitnet3557 3 месяца назад
@@BartonOilBurnerServices Thanks for your reply,how high from the floor is the oil pump?The tank base will end up being 17 inches higher than the kitchen floor will this be OK for gravity feed without a tiger loop?.
@BartonOilBurnerServices
@BartonOilBurnerServices 3 месяца назад
@@andrewwhitnet3557 That will not need a tiger loop. Have a great weekend.
@andrewwhitnet3557
@andrewwhitnet3557 3 месяца назад
@@BartonOilBurnerServices Thanks.
Далее
How to service a Grant oil fired boiler
44:48
Просмотров 32 тыс.
Schoolboy - Часть 2
00:12
Просмотров 6 млн
Grant Vortex Combi Boiler Service
10:54
Просмотров 48 тыс.
How To Install A Hive Smart Thermostat - Combi Boiler
14:22
Another house saved from a combi
9:47
Просмотров 146 тыс.
ECA Arceus 12kW Electric Combi Boiler Install
18:58
Просмотров 36 тыс.
Is Your Central Heating System Losing Pressure?
6:43
Просмотров 340 тыс.
Combi boiler conversion - Working in stages
13:27
Просмотров 4 тыс.
Oil Boiler Install With Some Dangerous Discoveries
26:25
How Condensing Boilers Work - Plumbing Tips
6:01
Просмотров 15 тыс.