Тёмный

Ground-Fault Circuit Interrupters (GFCIs) 

MikeHoltNEC
Подписаться 116 тыс.
Просмотров 11 тыс.
50% 1

Опубликовано:

 

17 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 49   
@LLAMA-gym
@LLAMA-gym 6 месяцев назад
Didn’t realize how much I just love watching someone passionate about a subject. Inspiring to levels absolutely unmeasurable.
@MikeHoltNEC
@MikeHoltNEC 6 месяцев назад
Aww thank you for noticing my passion.
@Dredpath1
@Dredpath1 11 месяцев назад
We need more people like Mike Holt in this world
@ideclarejoshua
@ideclarejoshua 11 месяцев назад
In school getting my apprenticeship hours, learning this stuff now. Cool to see you are posting on RU-vid, my second home. Thumbs up!
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Welcome to a great trade! God Bless, Mike
@OnusofStrife
@OnusofStrife 6 месяцев назад
Enjoying your videos as a curious homeowner laymen. I recently went around my house and tested all my outside GFCIs. Some did not reset. Watching this made me realize the failure to reset means the receptacle needs to be replaced as the electronics have failed. That makes sense but was totally not obvious.
@MikeHoltNEC
@MikeHoltNEC 5 месяцев назад
Wow, scary. Glad my work helped you make your home safer.
@Ariccio123
@Ariccio123 7 месяцев назад
I haven't even watched the whole video yet, I just want to evangelize about the wonders of audible alarm GFCIs - these should be the standard! It's a really user friendly option for everybody!
@matthewcarroll6640
@matthewcarroll6640 11 месяцев назад
Mike definitely has a method of teaching that makes it easy to follow and understand, so definitely gotta give him props. Thank you for all your materials. Mike.
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Thank you!
@j81851
@j81851 11 месяцев назад
Mike you look so good. Serving the Lord and others along with a good life has a very positive effect. Thank you for all your efforts. After 50 years in the trade you are the champion of electrical safety and a personal hero of mine. Long life good health and prosperity to you. Love to meet you one day and return a smile and a warm handshake! Be blessed my brother.
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
How sweet is this message my Brother. Let's make it happen.
@shaneoakley8757
@shaneoakley8757 5 месяцев назад
I’m in an apprenticeship program with the state of NC to get a standard certification as a level 1 electrical inspector and let me just tell you. Mike Holt gets mentioned a lot! 😎 Love and appreciate these videos! I keep them playing as I travel all over the state
@MikeHoltNEC
@MikeHoltNEC 5 месяцев назад
Lol, give a shout out to them for me.
@shaneoakley8757
@shaneoakley8757 5 месяцев назад
@@MikeHoltNEC I sure will!!
@TRYtoHELPyou
@TRYtoHELPyou 11 месяцев назад
test monthly, will do. Even though this is geared towards the students and professionals this is great information for the non-professional non-student (formal) trying to better themselves by gaining knowledge about the subject. Thanks all for doing what you do!
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Thank you.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 11 месяцев назад
Great explanation of imbalance
@highwaymen1237
@highwaymen1237 11 месяцев назад
Great video. Watched you're downhill bike video, very impressive.
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Lol... thanks.
@bohill1832
@bohill1832 10 месяцев назад
According to the NEC, can GFCI outlets be installed in bathrooms 16” above finished floor.
@MikeHoltNEC
@MikeHoltNEC 10 месяцев назад
The required sink receptacle in bathrooms must be installed in accordance with 210.52(C), which would not permit it to be 16" above finished floor. However other receptacles in the bathroom or other rooms in residential or commercial occupancies can be installed at any height, even in the floor.
@robertseverino8931
@robertseverino8931 11 месяцев назад
Hi Mike! I appreciate you sharing all your knowledge with all of us which has always been of an immense value to me. I have a request for you that’s probably been done in the past, but I’m sure you could make it happen. If possible to transfer all your electrical books ober to Autible or any audio format. If you do have it in this format, please advise or send link. Thank you!
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Send me an email, Mike@MikeHolt.com, and let's discuss this further.
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
All of our Products that include Video also include audio streaming.
@harpreetkaur5947
@harpreetkaur5947 11 месяцев назад
Hello Mike, I have been watching and learning through your vedios for few years now. If possible can you please make a vedio on NEC Article 501. I know you made a vedio few years ago on Hazardous Area Classification. But if you would make a detailed vedio on wiring methods, Conduits, Fittings, Conduit Seals, Enclosures, Termination boxes inside Class 1 Div 1, Class 1 Div 2 areas. What are design considerations at the boundaries of each area. I work in Waste Water Industry, if you could explain using examples from lift station etc that would be great. There are multiple people around me that can use your guidance for a better understanding of Article 501. Also this will touch some topics of NFPA 820. Thanks.
@davem5392
@davem5392 11 месяцев назад
I would really appreciate with all the commercial restaurant requirements if you could go over function of 3 phase breakers. I think most do not understand this
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
? A three-phase breaker functions just like a two-pole or single-pole breaker...
@zebiosogliani7132
@zebiosogliani7132 9 месяцев назад
Why not use GFCI break type in the electrical panel instead of the outlet type?
@MikeHoltNEC
@MikeHoltNEC 9 месяцев назад
GFCI is set to trip between 4 - 6 mA, if you used it for the entire house, expect that you'll be losing power often.
@mikeadler434
@mikeadler434 11 месяцев назад
👍👍
@wuilliamscoa3467
@wuilliamscoa3467 4 месяца назад
Think about your answer!
@MikeHoltNEC
@MikeHoltNEC 4 месяца назад
What?
@jolyonwelsh9834
@jolyonwelsh9834 Месяц назад
The newer GFCI receptacles now knock themselves out of operation when the protection is lost for whatever reason.
@MikeHoltNEC
@MikeHoltNEC Месяц назад
No, there are multiple options. One option is a sound, a light, or deenergize.
@jolyonwelsh9834
@jolyonwelsh9834 Месяц назад
@@MikeHoltNEC the ones I have seen simply deenergize.
@MikeHoltNEC
@MikeHoltNEC Месяц назад
You must be using Leviton. P&S states "automatic self-test every 3 seconds. If the device ever fails, the indicator light flashes to signal it should be replaced." Now you learned something new.
@jolyonwelsh9834
@jolyonwelsh9834 Месяц назад
@@MikeHoltNEC I use P&S as well. I've never known that they sound an alarm.
@MikeHoltNEC
@MikeHoltNEC Месяц назад
I'm sure it's in their instructions.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 11 месяцев назад
I came up with an idea, imagine a non-contact voltage tester or detector, that is a watch type that you wear on your wrist, when you touch it hot wire, watch detects voltage, transmits signal to cell phone, cell phone transmits signal to disconnect with receiver and disconnects circuit, and or entire sub panel or panel, what do you think about my idea ? Oh, maybe false tripping ? Insulated coil Ring on index finger that detects current through finger, then to watch, cell phone, and trip circuit, sub panel or panel or disconnect with receiver
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Sounds like it's complicated that this watch would know what breaker to turn off. Let me know if you ever get such a device made.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 11 месяцев назад
@@MikeHoltNEC I’m working on it now, not as easy as I thought to detect voltage, current, I am learning about op-amps, I imagine when I figure this part out, the rest will be easy, I am thinking
@MikeHoltNEC
@MikeHoltNEC 11 месяцев назад
Would be nice.
@genebowdish.mageniemagic
@genebowdish.mageniemagic 11 месяцев назад
@@MikeHoltNEC I just posted one of my circuits I was talking about, could be smaller, could be wireless, I have many more ideas on this topic, Gene Bowdish
@wuilliamscoa3467
@wuilliamscoa3467 4 месяца назад
Máster you should translate your books to spanish you going to make a lot of Money!
@MikeHoltNEC
@MikeHoltNEC 4 месяца назад
My products are based on the National Electrical Code for those living in the US. I feel that to provide a safe installation, the electrical professional needs to speak and read English. So there is no plan to translate any of our products into Spanish. Note: Money doesn't drive me; just electrical safety.
@wuilliamscoa3467
@wuilliamscoa3467 4 месяца назад
@@MikeHoltNEC👍🏼
@wuilliamscoa3467
@wuilliamscoa3467 4 месяца назад
The nec is translated to spanish, to humble my friend!
@MikeHoltNEC
@MikeHoltNEC 4 месяца назад
@@wuilliamscoa3467 What does this have to do with your original question and my original response.
Далее
GFCI, Special Purpose Type 26.3
13:07
Просмотров 7 тыс.
Industry Voltages
18:44
Просмотров 9 тыс.
moto tag - AirTag для Android
00:47
Просмотров 428 тыс.
AFCIs, Clearing Series and Parallel Arcing Fault
17:47
Grounding Versus Bonding (26min:26sec)
26:26
Просмотров 249 тыс.
Electrical Theory - Introduction
22:24
Просмотров 37 тыс.
Where Does Grounded Electricity Actually Go?
19:36
Where Should We Be Using Dual Function Breakers?
15:32
Просмотров 115 тыс.
Neutral-to-Earth Voltage (NEV), NEC 2020, (44min:40sec)
44:40
Grounding, Objectionable Current [250.6, 2020 NEC]
18:15