Тёмный
No video :(

Hanna Lab - Learn How to Set Up and Calibrate the Hanna Instruments pH, EC, TDS Combo Tester HI98129 

Hanna Instruments, Inc.
Подписаться 12 тыс.
Просмотров 91 тыс.
50% 1

Опубликовано:

 

21 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 66   
@rundowner46
@rundowner46 2 года назад
Good morning kassandra. I just bought model #HI98129 PH/EC/TDS combo tester. Reading the manual I couldn't figure out how to change, the temperature units of measurement. This presentation video, made it very easy to understand. I kept press but not, holding mode button. For 6 seconds after the unit was turned off. Thank you for the presentation video. Now I need some distilled water.
@Arycke
@Arycke 6 лет назад
I used this in field research and it worked wonderfully. The tolerance is nominal and it is quite portable. Thank you for the upload and product.
@ChrisGtek
@ChrisGtek 2 года назад
I’ve had my Hanna combo Meter since 2011 haven’t looked back since i even own a blue lab combo one I prefer my Hanna meter anytime 👍👍👍
@NatureBound
@NatureBound 4 года назад
I'm on my third one this year. My last one lasted two weeks, never dropped, never went dry, used and cleaned daily. kinda getting sick of spending $200 at a time for something that can't last more than a few months.
@kbg4life07
@kbg4life07 4 года назад
Dang mine has been running strong for 7 years already
@fernandoolalde6231
@fernandoolalde6231 3 года назад
@@kbg4life07 😐
@wayneessar7489
@wayneessar7489 3 года назад
Isn't there a two year warranty?
@heywoodjablome5630
@heywoodjablome5630 Год назад
@@wayneessar7489 just one year, but no warranty against careless or clumsy users.
@serpico2206
@serpico2206 4 года назад
Why dont you guys deliver “calibrated” version of this product ? its 150 $.... cant you guys do “pre calibrated” electrodes?
@dennfox1464
@dennfox1464 4 года назад
Best question on this page!
@tee228
@tee228 3 года назад
i think its calibrated out the factory but after being stored on store shelves for who knows how long, the probe could possibly dry out a bit making it not as accurate
@jagdishraval7466
@jagdishraval7466 3 года назад
My new instrument is autometic goes in 10.01 Ph Calibration even on selecting 7.01 as well using 7.01 buffar
@agassociates8486
@agassociates8486 4 года назад
Just bought your HI98129. I'm unable to calibrate it even after following all the steps. ph 7.01 solution shows 7.18 and ph 4.01 solution shows 4.57. Can you guide?
@peaches021272
@peaches021272 4 года назад
Simple to follow with this video.
@Babykuttyvibes
@Babykuttyvibes 4 года назад
Trying to do the two point calibration with brand new HI98129. Always getting the WRNG message when i am switching from 7.01 buffer(HI7007) to 4.01buffer(HI7004). I rinse the electrode in RO water before putting it in 4.01 buffer. What must be going wrong? Please advice..
@moritzkeller4502
@moritzkeller4502 3 года назад
I am wondering as well, nothing about this errorcode in the manual. Have you found a solution?
@clutch1126
@clutch1126 3 года назад
Still no answer... Crap giving me the same thing
@redrhapsody1415
@redrhapsody1415 2 года назад
Try leaving the probe in your solution for a bit longer. The probe says wrng when it doesn't detect the correct solution. After a few seconds the error message should go away allowing you to proceed. Hopefully this helps you in your endeavors!
@haidermehdi1322
@haidermehdi1322 4 года назад
good evening can you tell me how to calibrate the hanna H199300 consuctivity meter
@jojimonty2506
@jojimonty2506 6 лет назад
Where can I get the test solutions? My meter is not reading correctly.
@HannaInc
@HannaInc 6 лет назад
Hi Joji. You can visit a local retailer or visit hanna's website for buffers and cleaning/storage solutions. How old is your meter? Can you give me a little bit more information about what's going on?
@malte4919
@malte4919 5 лет назад
Really like my Hanna combo, but can't your company give names which I can remember? What do I need to calibrate? 1805226 or 2590522 or was it 598643? :(
@HannaInc
@HannaInc 5 лет назад
Hi Bee. Glad you like your meter! We do have some long names for our products, but hopefully we can help simplify it for you. If you visit hannainst.com you can find all the calibration solutions you need. Typically with this meter, you would want pH 7.01 Buffer (HI7007) pH 4.01 buffer (HI7004) pH 10.01 Buffer (HI7010) & 1413 µS/cm EC Standard (HI7031) Depending on what you're measuring, you may not need the pH 10.01 buffer. It all depends on your need. Hope this helps!
@myneymo77
@myneymo77 3 года назад
My left button, only switch off the unit, anyone can help? No mode button functioning
@rundowner46
@rundowner46 2 года назад
I had the same problem buddy. Until I watched the video. I'm a slow one. Took me a few to many off a one. To understand; how to get there. I turned mine on. Then made sure it was in ph mode. Pressed the mode button. Which will show off. Now hold for 6 seconds. Changed the temperature range. The instructions in the manual were confused. But kassandra cleared it up for me. Thank you kassandra. I hope your doing well. Since all this covid $h!t. Hope this helps Le Badger? I hope all is well buddy.
@clutch1126
@clutch1126 3 года назад
Bought one of these but when calibrating it tells me wrng when put on to 4.01 solution. Cleaned for over an hour and soaked in 7.01...
@redrhapsody1415
@redrhapsody1415 2 года назад
Hopefully you found a solution! What I did when this problem occurred was rinsing with DI water in between cal solution. It will still say wrng when you go to place the probe into the next solution but, ignore that and leave it in the next solution for a minute and it should continue with calibrations. The probe will say wrng when it doesn't detect the correct solution and after a few seconds it should allow you to proceed. Hopefully this helps the next person who has this problem!
@matutawavitabernard1702
@matutawavitabernard1702 6 лет назад
need how to i can make calibration
@HannaInc
@HannaInc 6 лет назад
Hi MATUTA, calibration is really simple. Press the MODE button until you see CAL on the screen. From there, it will prompt you for your buffers.
@nawelder768
@nawelder768 6 лет назад
PLEASE I WOULD LIKE TO KNOW HOW TO CHANGE THE POINT OF CALIBRATION OF CONDUCTIVITY BECAUSE 1413 IS TO HIGH
@HannaInc
@HannaInc 6 лет назад
Hi nanou. You want to be in EC/TDS mode. From there you can enter calibration mode and change the setting from there. Hope this helps! You can find the demonstration at 3:47 in the video.
@naveedakhtarid
@naveedakhtarid 2 года назад
how to remove wrng error during ph calibration process.
@naveedakhtarid
@naveedakhtarid 2 года назад
The answer of this question is still pending..... Plz any expert in calibration help
@redrhapsody1415
@redrhapsody1415 2 года назад
The meter gives the error message "wrng" when it doesn't detect the correct solution. After a few moments it should go away allowing you to proceed with your calibrations. This occurred for me when I would rinse my meter with DI water after the 7.01 solution prior to putting it into the 4.01pH solution. Hopefully this helps!
@miguelcarrera83
@miguelcarrera83 5 лет назад
Hello Can you help me? I can't calibrate my HI98129. I'm using a new 1413 microsiemens solution, but the screen says "Wrong" My Hi98129 is new too. What could be the problem?
@HannaInc
@HannaInc 5 лет назад
Hi Miguel. It sounds like you're in the pH mode. The first thing you want to do is put the meter in EC mode, and then enter Calibration.
@miguelcarrera83
@miguelcarrera83 5 лет назад
@@HannaInc No, I'm in the EC mode. Another thing? Thank you.
@HannaInc
@HannaInc 5 лет назад
@@miguelcarrera83 Are you in µS or ppm mode. Is it asking you for the 1413 or 1382 when you enter CAL mode?
@miguelcarrera83
@miguelcarrera83 5 лет назад
@@HannaInc In microsiemens mode. I have 0.5 of conversion factor and 2.0% of temperature coeficient
@HannaInc
@HannaInc 5 лет назад
@@miguelcarrera83 contact tech@hannainst.com They can help you step by step to see what's happening. Hope this helps!
@solangeriveragarces313
@solangeriveragarces313 6 лет назад
you have an email for information?
@HannaInc
@HannaInc 6 лет назад
You can contact sales@hannainst.com or visit hannainst.com for more info!
@kennethtomer5553
@kennethtomer5553 5 лет назад
Stay away from these. I bought one for christmas and did not work right out of package. And the warranty is not covered because hydro store did not give me a receipt.. what a waste
@HannaInc
@HannaInc 5 лет назад
Hi Kenneth. Buying from a store can sometimes mean the meter may have been sitting for a while. Electrodes need to be rehydrated with storage solution when they become dry. I'd recommend soaking it in your storage solution for 2 hours and then trying it again. If it still doesn't work, contact tech@hannainst.com
@kennethtomer5553
@kennethtomer5553 5 лет назад
Not when it won’t even power on
@raymondolivares1093
@raymondolivares1093 5 лет назад
98129 test TDS as well?
@HannaInc
@HannaInc 5 лет назад
Hi Raymond. Yes it does!
@g_pokesport9165
@g_pokesport9165 6 лет назад
My meter looks exactly like this but reads in ph, ms, ppt.
@HannaInc
@HannaInc 6 лет назад
Hi Gary! You must have the HI98130 meter. Awesome choice!
@jakeyasutomi
@jakeyasutomi 6 лет назад
Holding the mode button only turns my meter on. Is there anything else I can do to calibrate it ?
@HannaInc
@HannaInc 6 лет назад
Hi Jake, The Mode button does turn the meter on, but once it's on, press the button again and hold it. You'll see CAL displayed on the screen. Release the button and it will ask you for your first calibration buffer. If you still have issues let me know!
@emilianobernardo4285
@emilianobernardo4285 6 лет назад
I just want to ask about the calibration of the High range ph meter I was confused while I'm doing calibrate using buffer ph 7.01 then after a few Seconds 10.01 was indicated in LCD screen instead of 4.01. it's there's any problem ? or I can use also the 10.01 for the 2nd point of calibrating?.
@HannaInc
@HannaInc 6 лет назад
The tester will automatically recognize which buffer you use. It seems it is just going to the next point up, but if you were to use pH 4.01, it would recognize and calibrate accordingly. Using pH 4.01 or 10.01 first will do a 1 point calibration by default.
@harmeetsingh371
@harmeetsingh371 5 лет назад
Hello maam one of my ec/ph meter didnot calibrate model hanna HI98130
@HannaInc
@HannaInc 5 лет назад
Hi Harmeet. Would it not enter calibration mode or not stabilize? Many times, a stabilization issue is due to a dehydrated electrode. It's important to keep it stored in storage solution. Something that works is if you let your electrode soak in storage solution for an hour, it will rehydrate and should work just fine.
@DontWorryImNorwegian
@DontWorryImNorwegian 5 лет назад
You don't show/tell people how to get the damn thing into calibration mode before showing how to calibrate it!
@HannaInc
@HannaInc 5 лет назад
Hey there! Not to worry. If you press the mode button for 3 seconds it will bring you into calibration mode.
@gabesworld7830
@gabesworld7830 2 года назад
paid like 150 for this is I remember correctly and after less than a year it will not calibrate. Sucks!
@naveedakhtarid
@naveedakhtarid 2 года назад
Plz,
@yesinekhan8423
@yesinekhan8423 3 года назад
wow you are so cute
@betosito124
@betosito124 2 года назад
You are right
Далее
Are You Making These Top 10 pH Mistakes?
6:46
Просмотров 124 тыс.
The Bingo Paradox: 3× more likely to win
30:15
Просмотров 332 тыс.
Ph метр HANNA COMBO HI98129
3:27
Просмотров 736
Damascus Steel From Stick Welding Electrodes
14:15
Просмотров 340 тыс.
From DNA to protein - 3D
2:42
Просмотров 19 млн
A Beginners Guide: Electrical Conductivity (EC)
11:50
Просмотров 185 тыс.