Heat Load Calculation in Hindi | Heat Load Calculation in HVAC Part - 1 

Tec Engineering
Подписаться 19 тыс.
Просмотров 117 тыс.
50% 1

This tutorial explains about " heat load calculation using formula " and explain how to heat load in wall and roof. Hope you will understand heat load calculation in hvac.
Download for uses in data table
tecengineering...
Heat Load Calculation in Hindi | Heat Load Calculation in HVAC Part - 2
• Heat Load Calculation ...
Heat Load Calculation in Hindi | Heat Load Calculation in HVAC Part - 3
• Heat Load Calculation ...
Heat Load Calculation in Hindi | Infiltration Heat Load Calculation in HVAC Part - 4
• Heat Load Calculation ...
Ventilation System in Hindi | Heating Ventilation and Air Conditioning Part - 5
• Ventilation System in ...
Thanks and Love #TecEngineering
LIKE | COMMENT | SHARE | SUBSCRIBE
=====================================
==========
Website www.tecenginee...
Facebook / tecengineering.in
WhatsApp Group chat.whatsapp....
================================================
==============
WhatsApp Number +917036691232
E-Mai :- tecmep46@gmail.com
Any hvac & mep design & Drafting please contact me

Опубликовано:

 

30 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 86   
@shyamalsaha4474
@shyamalsaha4474 6 месяцев назад
Can you provide a sample calculation for a/c load of a ship ?
@tecengineering2018
@tecengineering2018 6 месяцев назад
Yes
@MohdRashid_9455
@MohdRashid_9455 5 лет назад
Hi sir, How did come out side and inside area 0.25 ???? pls clarify...
@sandrosherma2830
@sandrosherma2830 3 года назад
Im pretty sure only indian people understand 100% of what he is talking... dude, for us its really difficult, at least try a robot to talk for you
@sourajitpattanaik8850
@sourajitpattanaik8850 9 месяцев назад
How to get cfm easily
@tecengineering2018
@tecengineering2018 6 месяцев назад
Ton x 400 kr do = Cfm mil jaega
@sattarabdul6016
@sattarabdul6016 15 дней назад
Sirji, aapney N , S, W, E sey Heat gain ke baarey kuch mention hi nahi kiya😊
@aabidali2628
@aabidali2628 4 года назад
Value of inside air is 0.65 not 0.25..
@thethrillingworld8527
@thethrillingworld8527 4 года назад
can you help me in getting the table for r values ?
@prakashratha6967
@prakashratha6967 4 года назад
How did you take O/A & I/A as 0.25 for wall and for roof how you know I/A as 0.6
@avinashs7284
@avinashs7284 3 года назад
Ishrae data book bro
@Entertainment-gq6hd
@Entertainment-gq6hd 5 лет назад
out area aur inside area 0.25 kaise culculate krenge sir ispe video banai
@shubhamgovil9976
@shubhamgovil9976 4 года назад
Concept was Good But can you tell me How you are getting Q=2430 BTU/hr ? Because same value i am putting, my answer is coming Q = 2470.5BTU/hr.
@afnansiddiqui9158
@afnansiddiqui9158 4 года назад
he has solved it directly in calculator without putting any bracket or you can say without using math rules
@palashsarkar486
@palashsarkar486 Год назад
How do you calculate inside area as 0.25?
@naimulahasan9864
@naimulahasan9864 3 года назад
INSIDE AIR IS (R) = 0.65 IN YOUR LINKED DATA TABLE WHY YOU USE 0.25 AT BOTH O/A AND I/A ???????? ????????????????????????
@Elvisyadavfanpage128
@Elvisyadavfanpage128 Год назад
Cp means kya h
@safiullah3504
@safiullah3504 5 лет назад
Hi sir, I don't know hindi.even I am watching your video. how did come outside & inside area 0.25 for find out u value.can you clarify to me
@aveshtatkare6295
@aveshtatkare6295 4 года назад
This is also my question .????
@rameezpansari6473
@rameezpansari6473 4 года назад
bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@mohammadshahzeb2459
@mohammadshahzeb2459 5 лет назад
sir Area ft square me he or U Factor ke lye inches use k r rhe to is se difference to ni ae ga na
@aaryanikadiyala6039
@aaryanikadiyala6039 4 года назад
video is very good but the data table link is not working.
@rameezpansari6473
@rameezpansari6473 4 года назад
bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@arshidlone7261
@arshidlone7261 4 года назад
Sir you have taken out side area 0.25 how this value have been determined
@rameezpansari6473
@rameezpansari6473 4 года назад
bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@engineeringconcept4461
@engineeringconcept4461 3 года назад
you have to consider correction factor to calculate the heat gain through wall
@arifalam2115
@arifalam2115 2 года назад
Bhai dil❤se salam aapne mera sara confusion door kar diya stap by stap samjha kar...thanks brother.
@tecengineering2018
@tecengineering2018 2 года назад
Welcome
@rehanafset
@rehanafset 3 месяца назад
How did you get the outside and inside values "0.25"?
@sarabjitsingh3258
@sarabjitsingh3258 2 года назад
What is 0.25
@khalilmondal3876
@khalilmondal3876 Год назад
please make a video on heating load calculation
@tecengineering2018
@tecengineering2018 Год назад
Ok , next week I will upload your video
@khalilmondal3876
@khalilmondal3876 Год назад
@@tecengineering2018 Thanks
@Jo_oJ94
@Jo_oJ94 4 года назад
How do you get the outside and inside areas
@khadarbasha424
@khadarbasha424 5 лет назад
HOW TO DOWNLOAD DESIGN DATA BOOK
@rameezpansari6473
@rameezpansari6473 4 года назад
@@ALAHAD308 bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@akashdarwatkar1014
@akashdarwatkar1014 5 лет назад
Sir wall ka sametion value 1.42 aa raha hai aap ne 1.82 kase nikala ????
@rahulKumar-zl5un
@rahulKumar-zl5un 3 месяца назад
CP kay h full form
@ravikumar2871
@ravikumar2871 27 дней назад
Cement plaster
@Indiaworldlyasmr
@Indiaworldlyasmr 4 года назад
Outside area ka aapne 0.25 liye ye ashrae se malum pada kya 0.25❓❓
@rameezpansari6473
@rameezpansari6473 4 года назад
bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@saffu54ya
@saffu54ya 4 года назад
Sir I request u to please Aap apne es channel par full hvac course provide kar do aap starting se last tak lecture upload kar do please sir I request u. Series bna do full hvac syllabus
@shaikhmoazzam2656
@shaikhmoazzam2656 3 года назад
Why you are taking 0.25 for O/A and I/A
@VenuGopal-lg5gl
@VenuGopal-lg5gl 3 года назад
Sir. Cooling load preheter loan Re heater load explain calculation
@kamranamin8889
@kamranamin8889 4 года назад
Sir jb wall heat load kren ge..to is me se door ka area bhi subtract kren ge ya nh???
@PradeepPradeep-h2i
@PradeepPradeep-h2i Год назад
How calculate value of inside air or out side air.
@satyambhardwaj2806
@satyambhardwaj2806 5 лет назад
Sir aapki video achi thi or sabnay itni bakwaas daal rakhi hai jis ko sunn. Kr k sarr main dard ho gya.main architecture ka student hu.meray paas topic hai heat loading or cool loading Issay cover ho jayega na heat loading?.
@listenhaq5118
@listenhaq5118 4 года назад
Bhai HAP software ka detail vedio banae
@vipulpatel5762
@vipulpatel5762 4 года назад
equipment load calculation
@tecengineering2018
@tecengineering2018 4 года назад
Heat Load Calculation in HVAC Part - 2 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-AwekBKv_FQM.html Heat Load Calculation in HVAC Part - 3 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-apA5sGH9T4E.html Infiltration Heat Load Calculation in HVAC Part - 4 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-XMGIQuArgq0.html
@sanjaymurmu7735
@sanjaymurmu7735 2 года назад
calculation for 4 inch wall is wrong please correct it
@tecengineering2018
@tecengineering2018 2 года назад
Ok
@SatendraKumar-we6oc
@SatendraKumar-we6oc 5 лет назад
Sir aap ne wall u 1.82 kese nikala hai mere se to 1.42 aa rha hai aap kese nikala hai ??? Video me batao
@shahfarazahmadsiddiqui3508
@shahfarazahmadsiddiqui3508 4 года назад
Sir outside aur inside area kaisa lia
@chsaeed567
@chsaeed567 5 лет назад
Sir heat load calculation ma room ya place jis ka liay heat load calculate karty ha to us place ke direction matlab us ke east , west,North and South ke walls sa heat load same farmola sa nikaly ga ya different farmola sa or kis tarh nikaly ga Plz sir guide me very soon since we have to submit a project about it till cooming Saturday. Plz sir plz
@Sajjadynwa
@Sajjadynwa 2 года назад
We take afternoon load.at that time heat is most gained by any system 3-4 pm
@rameezpansari6473
@rameezpansari6473 4 года назад
sum n R value 1.30 aati hai
@pateldishantpateldishant8646
@pateldishantpateldishant8646 4 года назад
Thank you Sir
@tecengineering2018
@tecengineering2018 4 года назад
Most welcome
@satyambhardwaj2806
@satyambhardwaj2806 5 лет назад
Usmay u factor wagera b hai
@deoriaup52
@deoriaup52 4 года назад
Please send me part 2 to 3
@HARISHKUMAR-yz3gz
@HARISHKUMAR-yz3gz 4 года назад
very nice
@tecengineering2018
@tecengineering2018 4 года назад
Thanks
@gijuthomas8759
@gijuthomas8759 4 года назад
Please present these in English
@madmehtab
@madmehtab 4 года назад
Door load ka kya kre
@latishpatil9290
@latishpatil9290 4 года назад
nice and helpfull video but tumhne math ki puri wat laga di bhai Adition ko plus bolate he naki palas
@rohits6208
@rohits6208 3 года назад
Bhavnao ko smjho bhai😀
@zahoorahmed1498
@zahoorahmed1498 2 года назад
Can you make video on excel e20 sheet
@tecengineering2018
@tecengineering2018 2 года назад
Ok, I will try to make a video for e20 sheet
@zahoorahmed1498
@zahoorahmed1498 2 года назад
@@tecengineering2018 please make a video on e20 excel sheet
@engr.shohanurrahman3325
@engr.shohanurrahman3325 3 года назад
HOW TO DOWNLOAD DESIGN DATA BOOK
@tecengineering2018
@tecengineering2018 3 года назад
go to www.tecengineering.in
@arunpower7384
@arunpower7384 5 лет назад
Sir plz cross check ER value u got 1.82 i done the calculation of same got 1.42
@rameezpansari6473
@rameezpansari6473 4 года назад
1.30 aati hai
@rameezpansari6473
@rameezpansari6473 4 года назад
1/2 inch ko convert karna parega feet mai
@rameezpansari6473
@rameezpansari6473 4 года назад
ye chennel wala chutiya bana hai
@Alaminkhan-rc5mj
@Alaminkhan-rc5mj 10 месяцев назад
great vidio for learning
@tecengineering2018
@tecengineering2018 8 месяцев назад
Thanks and welcome
@almisbah_adoor
@almisbah_adoor 4 года назад
0.25...?
@muzaffershaik8336
@muzaffershaik8336 6 лет назад
Hai sir .... how to design and calculate pre engineering building (PEB) walls.... After calculating wall heat calculations ... How we decide this much TR is required for office or home. Please tell me sir...
@sumeetsharma2333
@sumeetsharma2333 4 года назад
Why O/A and I/A is taken as 0.25? Is ts given in ASHRAE? This question is asked by others too...... why dont you clarify the same?
@rameezpansari6473
@rameezpansari6473 4 года назад
bhai tumare pass ashrae ki handbook rahi to mai ko E-mail karo please my email id rameez4050@gmail.com
@arvindthakur8217
@arvindthakur8217 5 лет назад
0.25 ????
Далее
КВН 2024 Встреча выпускников
2:00:41
Cooling Load | hand calculation example | HVAC 13
20:33
Heat Load Calculation hvac in hindi
12:53
Просмотров 4,5 тыс.
Duct Sizing Calculation | Duct Design Calculation
14:33
Manual J Load Calculations 3D
11:24
Просмотров 32 тыс.
How to perform a quick load calculation
7:44
Просмотров 304 тыс.
КВН 2024 Встреча выпускников
2:00:41