How to perform a quick load calculation 

Expert Express plumbing heating and air conditioning
Просмотров 304 тыс.
50% 1

Raleigh, Durham, chapel hill, garner, apex, holly springs, and wake forest premier plumbing heating and air conditioning contractor. we are a family owned company with a proud tradition of being the best at what we do since 1922. we always use the highest quality parts and we provide the best quality service. Give us a call and find out why 99% of our customers recommend us to their friends

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 108   
@martysomoco
@martysomoco 3 года назад
Thank you for the most complete, most clearly presented, most thorough, most succinct, most helpful video on Manual J calculations on You Tube. I have watched so many presentations by so many so-called "experts" (including ACCA board members and authors associated with ACCA). Not a single one of those videos completely covers the process. All of them leave out some of the essential, necessary steps. None of them clearly provides enough specifics to actually do the Manual J analysis required by most jurisdictions for a new system install. Many of the so-called "experts" and "trainers" ramble on about irrelevant or personal information for the better part of 1 or 2 hours Typically, the presenters provide just enough information to get your interest and attention so that you will buy their book, pay for their services, or purchase parts or tools from their sponsors. Thanks again!
@charlton5787
@charlton5787 2 года назад
I loved using those load calc tables, we were also an Airtime 500 contractor. Those calculations are the job so much easier when doing loads.
@demondude1000
@demondude1000 Год назад
Easy video, I am jsut starting in the HVACR field so this is good info
@stlwrkr68
@stlwrkr68 8 лет назад
Great explanation!! Thanks for breaking this down into such an easy to understand way.
@tedjohnson64
@tedjohnson64 Год назад
Excellent tutorial, thanks for sharing this!
@eagletek1
@eagletek1 10 лет назад
Thanks for sharing.This will greatly bless our up coming business fulltime.
@Askexpertexpress
@Askexpertexpress 10 лет назад
your welcome
@pabloantonio9507
@pabloantonio9507 Год назад
Dope thanks for sharing
@heroknaderi
@heroknaderi 4 года назад
Very helpful thanks 🙏
@Askexpertexpress
@Askexpertexpress 4 года назад
Glad it was helpful!
@edithnogueira7899
@edithnogueira7899 5 лет назад
I suggested to pay a company to get the AC load calculations rather to install based to 1 ton every 400 sf. I have installed a 3.5 ton AC to a 1570 sf house and the size was wrong. All the AC contractor agreed the size was between 3 and 3.5 ton, but all of them were wrong. The AC turned on and off quick without completing the cycle, and not removing the humidity and not cooling, and therefore creating mold. A professional calculations done by engineering company specializing on this, shows that the correct size was 2 ton., could go up to 10% high in size. The AC was replaced, and the problem resolved.
@scubastevoo8404
@scubastevoo8404 4 года назад
who taught you that? the only thing close would be 400 CFM per 1 TON. not sq. ft.
@lucdumouchel3864
@lucdumouchel3864 Год назад
Have 2 questions. How do you calculate gains from ductwork. And second: when it says number of people: I have a hall to calculate with about 60 people and 1 bathroom. Do I calculate only 1 bathroom or calculate 60 people?
@andrescientos
@andrescientos 3 месяца назад
That's a cool pen.
@Yo_Jon
@Yo_Jon 2 года назад
Thank you for this bro
@Alhabshan_m
@Alhabshan_m 6 лет назад
Hello, thank you for your explaining. Actually, I did understand how we get the total BTU/h heat gain. Can you please show me how we calculate it?
@dennmillsch
@dennmillsch 4 года назад
I'd love to use this accu-size sheet but it only allows a few specific construction parameters. Doesn't work for R40 walls, or R-60 ceiling or triple glazed windows with U factor 0f 0.15. It could be useful if it had adaptable formulas rather than specific multipliers for specific construction only.
@Askexpertexpress
@Askexpertexpress 4 года назад
If you have other than a standard home a quick load calculation is not for you. I recommend you use the wright soft manual J program to correctly determine the exact BTU load requirements.
@KenTraining
@KenTraining 2 года назад
Can you help me I am wanting to find CFM’s for rooms once I know the Btu/h heating and cooling loads. I have the Manual J8AE spread sheet and the CFM outputs seem high to me and I wanted to see other calculations. I tried the Sensible Heat Formula of CFM = Sensible Btuh / 1.1 * Delta T But when I input those numbers I get higher CFM needed in areas that have lower Btuh heat loss/gain. Here is my example Home is in Laguna Beach California The area labeled 1st Flr Master Bedroom has a heat loss of 9138 Btuh and a Heat Gain of 4807 Btuh Manual J8AE want to provide 299 cfm for heating and less air (244 cfm) for cooling If I do the sensible heat formula CFM = Sensible Btuh / 1.1 x ∆ T , I am using 29 ∆ T for heating and 10 ∆ T for cooling I get 286 cfm for heating and more air (437 cfm) for cooling. This does not make sense to me with needing more cfm with less of a Btuh load. Can you show me where I am thrown off?
@humbertodiaz3137
@humbertodiaz3137 6 лет назад
Hello, i like your video. thanks for taking the time publish it. i have one question? you said that this worksheet is only for the part of US where you live in, but what does it have to be changed in order to use it in other parts or in other countries?
@dennmillsch
@dennmillsch 4 года назад
Oops, at 02:00 you calculate 33 sq ft, however you entered 8 when it should have been 18, meaning it should been 43 square feet.
@peterkalinin3775
@peterkalinin3775 5 лет назад
The formula is: 400 sf pet ton - for commercial and 500 sf per ton - for residential installations (8 ft ceiling).
@unibrowmonsterattack5527
@unibrowmonsterattack5527 8 лет назад
Thank you for it!
@peerod673
@peerod673 2 года назад
I love the explanation but I would love to know where they are getting the multiplier factor so I can convert to my region.
@Seabass1206
@Seabass1206 4 месяца назад
you need to find an Resistance value table for your building materials and also find your areas outdoor design temp
@IA-ge1et
@IA-ge1et 7 лет назад
Many thanks for sharing that with us. I can't help but wonder, how exactly you developed this sheet. I mean how you come up with multiplied numbers?
@Askexpertexpress
@Askexpertexpress 7 лет назад
+Al-Salama Ibraheem this is used by taking standard block load multipliers from government Publications
@jeffreywilliams3944
@jeffreywilliams3944 6 лет назад
Thank You
@6barry66
@6barry66 2 года назад
Nice video where can I go to get a worksheet like the one you have.
@crownjewels101
@crownjewels101 9 лет назад
Great video. If the average degree day for heating changes from 0 in your example to 25 then would the multipliers change also?
@Askexpertexpress
@Askexpertexpress 9 лет назад
crownjewels101 yes they are different the multipliers are found in the manual j guide every area has a different average temp that is listed in the guide as well
@rokiyayo6633
@rokiyayo6633 10 лет назад
Suscribed, good information
@jonathanavila9699
@jonathanavila9699 5 месяцев назад
Can I pay you to do a load calculation for me? Also how do you determine the region?
@user-el9kp7yk2o
@user-el9kp7yk2o 3 года назад
Good
@jayprojects5176
@jayprojects5176 4 года назад
Awesome Video. I'm very interested in using this form. Where did this form come from?
@juliejanczak715
@juliejanczak715 6 месяцев назад
Where do u get the form
@williamprothro2030
@williamprothro2030 5 лет назад
Where can I find the load sheets like you filled out
@spojj064
@spojj064 6 лет назад
Does anyone have a form, like the one in the video, for me to fill out but for Florida. My county building department needs energy calculations for our house, and I will be submitting it as owner builder, so we don’t need a contractor.
@islamfathi2184
@islamfathi2184 6 лет назад
If I have gymnasium and I want to calculate cooling capacity ,the area is 700m^2
@Askexpertexpress
@Askexpertexpress 10 лет назад
here is the link for the work sheet i use www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/?preview=true&preview_id=1437&preview_nonce=dad3624c86
@Barnekkid
@Barnekkid 8 лет назад
+Expert Express plumbing heating and air conditioning When I try to look at this I get a message saying I don't have permission to look at drafts. Is there another source?
@Askexpertexpress
@Askexpertexpress 8 лет назад
we are fixing the problem and will have it back up soon
@MR-nl8xr
@MR-nl8xr 6 лет назад
Expert Express plumbing heating and air conditioning. Problem still there.
@adambernard3196
@adambernard3196 3 года назад
For exterior heat loss, does it matter if there are rooms? Would you have a different total or heat loss per room?
@joshuacassino7297
@joshuacassino7297 3 года назад
Hello. I currently have a 40amp sub panel and need to accommodate an extra 60amps in it. In the 40amp sub panel there is a 15 amp and a 30amp. What size breaker do I need in the main?
@mohibnasir
@mohibnasir 6 лет назад
Can you please upload the link for the sheet you are using for writing all the values ?
@MrFrostynugs420
@MrFrostynugs420 5 лет назад
For retrofits, Use coolcalc.com and make sure your ductwork will support the cfm. 10 years doing calcs, all in Denver, only one complaint early on (wtf 8k sq ft house, loads get complicated with 6 and 1/2 systems) make a checklist with all required measurements and then xfer the info. It takes me one hour for measurements and another hour for completing the calc...+ drive time... All ways slightly oversize and design your sales programs to sell two stage equipment. Your fucking welcome kiddos! Best of luck!
@ManuelSanchez-ov2ed
@ManuelSanchez-ov2ed 5 лет назад
I'm in the Houston ,Tx area. Can you make one for this area, or do you know where I can get one just like the one you are showing?
@amokoikaw1
@amokoikaw1 Год назад
HOW DID YOU GET 70,000 BTU and decided to get a 2 ton unit furnace? Thanks . . .
@ashliemiller528
@ashliemiller528 7 лет назад
How did he get the 44431 from
@bklynwam
@bklynwam 6 лет назад
What do you suggest if you have a bilevel or tri level house (that has a garage and basement)? Thanks.
@gund89123
@gund89123 4 месяца назад
Almost no HVAC contractor does these calculations anymore, they pulling numbers out of thin air now.
@tonkie10
@tonkie10 7 лет назад
Regards friend. Great video. I'm designing a precision system for a data center, I have not experience working with data center precision cooling just with confort, so my questions are: do you have an example that you could share with me of load estimation for data centers? is the calculation procedure different from the confort loads? How do I know the needed power for a precision cooling system in a data center?. Thanks in advance for your help.
@Askexpertexpress
@Askexpertexpress 7 лет назад
+Jose julian we have designed hundreds of cooling systems for data center you have to use a commercial heat load calculation and find out what the manufacturing specs of the computers or other equipment located within the space is going to require as far as the BTU load for example Jose a computer puts off 3000 BTUs per hour x 1000 computers = 300k btu load. You also have to consider if it is an up Flow Design meaning that it's coming floor through the system your humidity will have to be controlled to prevent damaging the computers. You also have to look at static pressure within the room. Also take into effect static pressure on duct design
@SkipsTransAm2002
@SkipsTransAm2002 10 лет назад
Is there any way I can get a sheet like yours for alabama. It look easier? Thanks
@sprinter9166
@sprinter9166 6 лет назад
What would be your HTM for roll up metal shop doors? can't find in Manual J
@notanaccidentorg
@notanaccidentorg 2 года назад
Hello, are you still required to complete this for the exam in order to be certified? Thanks
@billyrayboo7315
@billyrayboo7315 2 года назад
I guarantee you you have 10 different contractors do that same worksheet on that home and you have 10 different answers. 2 Ton 800 cfm on 1400 Sq plus ft house good luck with that. Also most new hi efficient units will throttle up and down with the load. So what do that tell you a variable speed unit will cover the range from 24000 btu to 3.5 tons. You still comply with that bullshit that units to big and you got enough cooling on the real hot days to whistle Dixie not even break sweat and still keep the energy consumption down. Most house have 12 to 15 supply grills. You put that many on a 2 ton there want be squat of air coming out the vents
@grindtime76sanchez20
@grindtime76sanchez20 5 месяцев назад
What’s an app that can do this? I’m a salesman not a mathematician 😅😅
@sprinter9166
@sprinter9166 6 лет назад
Giving a load calculation on a 40-60 home car garage with 16 ft ceilings, don't know what BTU's to add for a hot car but i assume it could be at least 10,000 BTU's per hr.
@Askexpertexpress
@Askexpertexpress 10 лет назад
@1984juant
@1984juant 9 лет назад
Hey i cant find that sheet i just get the spreadsheet of acca which i dont really like too much..
@1984juant
@1984juant 9 лет назад
Never mind i found it in your blog. But how can i get the one from my region??
@Askexpertexpress
@Askexpertexpress 9 лет назад
What region are you in. I will make one for your region and posted on my website
@juantapia8079
@juantapia8079 9 лет назад
Im from south texas. I have house for this weekb i would like to try it. Thanks
@Askexpertexpress
@Askexpertexpress 9 лет назад
you can download the app "quick load" on the app store it works great and you can set the temps for your area
@simsource5017
@simsource5017 9 лет назад
Hey can u send me the link to get this load calulation worksheets
@aidanheidel3837
@aidanheidel3837 8 лет назад
good video, but how did you determine the final size of the furnace a/v unit? you did all the calculations but left out how you decided on a 2 ton unit. why? how? what was the purpose of all the calculations if you wer just gonna say, basically a 2 ton unit at the end. WTF
@One000Suns
@One000Suns 7 лет назад
Late response but he determined it would be a 2 ton AC unit by adding up all the Heat Gain numbers (left side of paper). He calculated 24773 BTUs of heat gain (bottom of page @5:47) and that is about a 2 ton AC unit. The right side of the paper is for heat loss and that relates to heating.
@srercrcr
@srercrcr 7 лет назад
Divide the 24773 BTU by 12000 = 2 ton.
@mayaroable
@mayaroable 4 года назад
2400 btu heat gain = 1200 btu per ton = 2ton of cooling. 61000 btu of heat loss÷.80 80% =a 80000 btu input furnace
@byrantilford923
@byrantilford923 4 года назад
Where can I find that paper
@rahulneela8554
@rahulneela8554 5 лет назад
Can u share PDF of the sheet
@sprinter9166
@sprinter9166 6 лет назад
it probably won't hurt a bit to add 25% for people who keep there A/C on 67 degrees especially in extreme temps.
@MOPARMANIATEXAS
@MOPARMANIATEXAS 5 лет назад
EXCEPT that over sized will cause Mold.
@alanhumphrey4198
@alanhumphrey4198 Год назад
What about in Texas??😊😊
@butlershvac4637
@butlershvac4637 6 лет назад
Can you create a sheet for Wilmington NC?
@theworshipdrummern8
@theworshipdrummern8 6 лет назад
Butlers HVAC check with your local offices. He didn’t “create” this. It’s an NEC type thing look online.
@eagletek1
@eagletek1 10 лет назад
can you share the sight to download form?
@Askexpertexpress
@Askexpertexpress 10 лет назад
www.acca.org/standards/acca-speed-sheets/ this is a link for the acca spread sheet I will be posting a copy of the block load sheet I use on our web site soon under the blog section
@Askexpertexpress
@Askexpertexpress 10 лет назад
here is the link to the work sheet I use www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/?preview=true&preview_id=1437&preview_nonce=dad3624c86
@Askexpertexpress
@Askexpertexpress 10 лет назад
here is the correct link www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/
@chrisej7586
@chrisej7586 7 лет назад
Expert Express plumbing heating and air conditioning b
@SombraLocs
@SombraLocs 4 года назад
@@Askexpertexpress Did you guys take it down?
@bobh1414
@bobh1414 7 лет назад
Where exactly did you get that form?
@srercrcr
@srercrcr 7 лет назад
The form is in Google Images
@hvacguy11
@hvacguy11 4 года назад
2 ton seems small for a 1404 square foot home I know thats the math but on a 95 degree day that’s no going to work
@mayaroable
@mayaroable 4 года назад
House is 1134 sq ft
@HiddenTruthExposed
@HiddenTruthExposed 3 года назад
What are we cavemen
@SkipsTransAm2002
@SkipsTransAm2002 10 лет назад
It will not let me Access the file you put on bottom? The block one?
@Askexpertexpress
@Askexpertexpress 10 лет назад
sorry here is the correct link www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/
@Askexpertexpress
@Askexpertexpress 10 лет назад
Expert Express plumbing heating and air conditioning click on the word heat for the pdf file
@Askexpertexpress
@Askexpertexpress 10 лет назад
Expert Express plumbing heating and air conditioning sorry heat loss
@SkipsTransAm2002
@SkipsTransAm2002 10 лет назад
Thanks for your help! Is there any way I could get one for Alabama? I think it calls for a heat gain day of 93 and heat loss 23. Thanks again and great videos.
@cyrusIIIII
@cyrusIIIII 7 лет назад
At the end why did you say you need a 2 Ton system? how did you calculate that for 61000 BTU? Shouldn't it be 5 Tons?
@One000Suns
@One000Suns 7 лет назад
The number 61000 was for "heat loss" so it applies to heater sizing. The left side of his form was for calculating "heat gain." This is for cooling and the number he calculated was around 24000 btu (bottom of left side form).
@cyrusIIIII
@cyrusIIIII 7 лет назад
Thank you
@mariobenoit7486
@mariobenoit7486 7 лет назад
So you divide number by 12 to get the tonage?
@srercrcr
@srercrcr 7 лет назад
divide by 12000. One ton = 12000 BTU
@buragaprasadbabu9226
@buragaprasadbabu9226 7 лет назад
I want in Telugu electrical videos
@DiamondHuang
@DiamondHuang 6 дней назад
Allen Patricia White Patricia Lewis Helen
@jayarellano122
@jayarellano122 6 лет назад
anu daw
Далее
ACCA Manual J Speed Sheet Example
57:50
Просмотров 10 тыс.
Commercial Load Calculations for HVAC
48:55
Просмотров 49 тыс.
Calculating Cooling Loads and Room CFM
15:20
Просмотров 311 тыс.
Heat Load Calculation: Manual J Made Easy
8:48
Просмотров 84 тыс.
How to size HVAC Equipment? #hvac #hvacsizing
7:29
Просмотров 21 тыс.
Cool Calc Vs Manual J Speed Sheet
22:40
Просмотров 10 тыс.
Cooling Load | hand calculation example | HVAC 13
20:33
Manual J (Load Calculation) Overview
52:20
Просмотров 37 тыс.
Understanding Manual J - HVAC Essentials
15:01
Просмотров 210 тыс.
ASHRAE Heat Load Calculation - Internal Loads (People)
13:36