This residential heat pump was frozen up due to a defective defrost board. I was fully aware I could've defrosted the heat pump by running it and air-conditioning mode at the thermostat and just pulling off the O terminal but that's not the point of why I did it the way I did it. I wanted to know whether or not the control board was defective, and that would prevent this from happening again, not getting a repeat call is a whole point of the service call not just getting it running again short term.
- Purchase your tools at www.trutechtoo...?aff=13 and use the offer code SURVIVAL to save 8% on your total purchase (exclusions may apply) -
D-TEK Stratus Detector trutechtools.c... 13 nt-Leak-Detector-and-Portable-Monitor?aff=
D-Tek 3 Leak Detector trutechtools.c...
Gas Mate Leak Detector trutechtools.c...
Inficon Recovery Machine trutechtools.c...
Inficon Comb Analyzer trutechtools.c...
Testo Comb Analyzer trutechtools.c...
Testo 557 Manifold trutechtools.c...
- TOOLS I USE -
FULL TOOL LIST ON THIS PAGE - kit.co/hvacrsu...
💥 Amazon Store: www.amazon.com...
SHORT TOOL LIST BELOW
MTR Micro 6000 Rosebud Heating Tip - amzn.to/3Qpmk5s
MTT Micro 6000 Flexible Twin Tip - amzn.to/40sTu92
MTF-5 Cap'n Hook Tip - amzn.to/3SnGr6E
Uniweld 71 Welding Handle Needed For Above Tips - amzn.to/3QiNJpC
TOPDON TC003 Thermal Imaging Camera, 256x192 IR High Res amzn.to/3sWLTTn
RIDGID 31305 Model E-110 9.5" Offset Hex Jaw Pipe Wrench - amzn.to/3Bar08y
Klein Tools Ratcheting Box Wrench 1/4 x 5/16 amzn.to/3GOpBrG
KNIPEX Tools - 10" Pliers Wrench amzn.to/3U7RRJf
KNIPEX Tools - 10" Cobra Water Pump Pliers amzn.to/3Wje8Wn
Knipex Tools - Mini Pliers in Belt Pouch amzn.to/3WguyyH
KNIPEX Tools - 4" Cobra XS Water Pump Pliers amzn.to/3UaQiKA
Bahco -6" Wide Mouth Adjustable Wrench amzn.to/3sHIsMV
Bahco - 8" Big-Mouth Adjustable Wrench with Rubber Handle - amzn.to/3SPhDB7
Knipex - 9.5-Inch Ultra-High Leverage Lineman's Pliers amzn.to/3DTLJ2h
Klein Tools Diagonal Cutting Pliers with Angled Head - amzn.to/3zuBVJb
Klein Tools Stripper, Crimper Tool - amzn.to/3gQQ6Su
Klein Tools Wire Cutter and Wire Stripper - amzn.to/3Fs627W
Klein Tools Kurve Wire Cutters, Heavy Duty Wire Stripping Tool - amzn.to/3FseIuW
Klein Tools Heavy Duty Automatic Wire Stripper - amzn.to/3SQdZab
Klein Tools Crimping and Cutting Tool - amzn.to/3TPIgXU
Klein Tools Screwdriver Adjustable 4 to 8-Inch amzn.to/3Nl6KWz
IDEAL INDUSTRIES Digital Circuit Breaker Finder - amzn.to/3DoBFwm
Fluke 376FC AC/DC Clamp Meter with iFlex - amzn.to/3UaNyx2
Fluke 62 Max Industrial Infrared Thermometer - amzn.to/3SNdwWg
Fluke 902 FC HVAC True-RMS Clamp Meter - amzn.to/3Ws7OfB
Fluke 87V MAX - amzn.to/3U6Rlv9
Fluke Networks Pro3000 Tone Generator - amzn.to/3WedklG
Fluke - FLUKE-52 Dual Input Digital Thermometer amzn.to/3zwFdf1
Ideal Safe-T-Grip Fuse Puller - amzn.to/3zsw2w4
Klein Tools Canvas Zipper Bag - amzn.to/3WgnJxq
Uni-Paint PX-20 Oil-Based Paint Marker - amzn.to/3sE3R9T
Stabila Magnetic Pocket Level PRO with Holster - amzn.to/3FtYLo0
Clip & Carry Kydex Multitool Sheath for LEATHERMAN SURGE - amzn.to/3TPJfHA
Kydex Multitool Sheath for LEATHERMAN WAVE & WAVE + PLUS - amzn.to/3sJlhlg
Cooper Atkins Thermistor Thermometer - amzn.to/3DLeHkC
GEARWRENCH Internal/External Ratcheting Puller 7 Ton 2 or 3 Jaw - amzn.to/3FxTU5l
**Warning Notice Disclaimer - Video content listed on the channel HVAC*R Survival is for entertainment purposes only and not meant to be a substitute for not contacting a competent HVAC/R PROFESSIONAL. Do not attempt anything said or seen on my videos, The tasks that are shown are dangerous and deadly without proper training.
**This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission. HVAC/R Survival is a participant in the Tru Tech Tools, Amazon Services Associates Program.

Опубликовано:

 

30 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 493   
@HVACRSurvival
@HVACRSurvival 3 года назад
ATTENTION 😒😒😒. 👉 I did a live show covering most of the comments that are being repeated or listed below. The link is in the note section and in the tag section of the video. The things I cover is....yes I made mistake and blew the fuse when I connected the jumper to the wrong terminal😱. I go into greater detail about this in my live show video. I also go into a lot more of my concerns while trying to diagnose this system. 👉👉 For those who keep repeating put it in AC mode and melt the ice that way..... That's only going to get the ice partially melted. 👉First, it's not going to melt all the ice because once it lose contact with the coil it's not going to melt any further 😲. 👉Secondly that doesn't tell me why the system froze up. But by running it in defrost mode over and over will tell me whether the system is capable of doing the job or not. It also tests the defrost board, the defrost termination switch and the refrigeration system all at once. 👉👉👉As with all of my videos, please make sure you watch the whole thing and don't skip sections then ask questions about things that were covered in the video. Thanks for watching and please consider subscribing 👍👍👍
@Bryan-Hensley
@Bryan-Hensley 3 года назад
I used to do that sometimes. Those boards are weird
@Falcon-eh8tq
@Falcon-eh8tq 3 года назад
Hey man thats what extra fuses are for and fuses in the first place, thanks for posting!keep up the good work
@jpp9876
@jpp9876 3 года назад
Dis you ever verify it stopped freezing up?
@HVACRSurvival
@HVACRSurvival 3 года назад
@@jpp9876 We never received a phone call stating otherwise. I'm sure they would have called if it didn't work.
@SovereignTroll
@SovereignTroll 2 года назад
As a tech you are good. When people put the air handler under a house so servicing is a challenge of slithering and light, testing more hazardous. Some people place at edge of house boosting ease of service.
@Moudaddy12
@Moudaddy12 3 года назад
You can just run a/c mode, have outdoor fan power unplug, to melt the ice in 10-15 minutes
@Moudaddy12
@Moudaddy12 3 года назад
Or you can stay in heat mode, jump out Y and O at ODU, with fan unplugged from defrost board fan relay. Never have to go inside to set the thermostat. Save you big time!
@HVACRSurvival
@HVACRSurvival 3 года назад
I was focused on why it froze and how to prevent it from happening again more than melting the ice. Hot or even cold water will melt the ice faster and completely vs any form of defrost cycle. Speed wasn't what I was looking for at that time. If I was sure what caused the ice then yes running it in cooling without the fan would have been the easiest way but wouldn't have worked fully once the ice melted and lost contact from the coil. It would have left a ice igloo around the coil.
@whitingservicesheatinganda3858
@whitingservicesheatinganda3858 3 года назад
@@HVACRSurvival i was thinking the exact same thing when I read the OP's comment
@HVACRSurvival
@HVACRSurvival 3 года назад
@@whitingservicesheatinganda3858 One tracked minds I guess?
@moconnell663
@moconnell663 3 года назад
Did you visually examine the solder-side of the 'bad' PCB? As an electronics guy, single sided boards are prone to having cracked solder joints and lifted pads. A local HVAC company wanted my mother to pay $3k for a new furnace over what was ultimately a single cold solder joint on the blower motor relay. Years before they wanted $3k for a new furnace due to repeated breaker tripping. It took me 4 minutes to diagnose a bad circuit breaker.
@lizzhing3159
@lizzhing3159 2 года назад
@@HVACRSurvival these days everything is liable
@jeffreywhitlatch1409
@jeffreywhitlatch1409 2 года назад
I know what you're saying about these other companies. I had someone with a variable speed blower that had a bad ECM, I told him to get somebody else, because he whined a little about how much it was going to be. The company who installed it came in and told them they needed to replace the whole five ton system for $12,000. I knew it just needed a blower module, which aren't really easy to get. So I went ahead and got an evergreen motor for it and fixed it. And I am an HVAC contractor, but I can't get over all these companies that won't fix anything, they just want to sell equipment and make a fortune off the customer. And I say, you'll have that with some companies. And I say it's either because they're desperate for money because of their outrageous overhead or no one knows how to fix it.
@charlessmith833
@charlessmith833 2 года назад
I'm an old and seasoned electronics guy also. If you can fix the board with a simple solder repair then just do it and don't brag about it. I've done it myself more than a few times. It saves a lot of cost and frustration for everyone. Too bad the new boards have a lot of unknown parts on them which makes it hard or impossible to repair. If that's the case then scrap it and get a new one. Everything has electronics now, even my toothbrush. Ain't progress just great?
@joblessalex
@joblessalex Год назад
@@HVACRSurvival I love it when people hide behind liability. Cheaper for you and you only to just throw it away and charge the customer 100x more to just replace it instead of fix it.
@LeObsidianCraft
@LeObsidianCraft Год назад
@@joblessalex in this case hvacr survival is only insured for HVAC repairs. That is not inclusive of repairs that would be considered better suited for other businesses. Maybe he could offer to send the board out to be repaired by a licensed and insured electronics repair person, but I would bet that this would cost just as much as a new control board and also have even more downtime as the system will be unable to run without the board. (In this case he left the broken board so heat would work and ordered a new one)
@Pennconst101
@Pennconst101 2 года назад
Another fun little tip when you come upon them super frozen like that, two things right out the gate. If its a normal open/close defrost sensor You can see if it’s closed Because it should be if it’s frozen like that. Also you need to make sure you’ve got 24+ volts red to common. If it does not have power to red Or has a broken/bad common wire, the timer will never start on the defrost board and it will never initiate defrost.
@rayray5340
@rayray5340 Год назад
I thought the same.
@matthewfields1330
@matthewfields1330 Год назад
Another tip I've found is if it's frozen solid like that it's probably not low on charge
@billj4859
@billj4859 3 года назад
Its a Nordyne. The old board was probably bad and the new one is probably bad too. Don't lose any sleep over it.
@HVACRSurvival
@HVACRSurvival 3 года назад
🤣 I can't agree more👍👍
@georgeian3243
@georgeian3243 3 года назад
Demand defrost control, at least in my experience, works on a deltaT based on a defrosted coil condition. Suppose the entering ODT is 40F and the outdoor coil temperature is 32F. That’s an 8F deltaT. Then, let’s say, after running in heat mode for one hour, the entering ODT is still 40F but the coil temperature has dropped to 26F. That’s a 14F deltaT which means the defrost board will soon initiate a defrost to bring the deltaT back to 8F (or so) deltaT. It should not take very long to do this, under 6 minutes is best, in fact, too many defrost cycles longer than 6 minutes or terminating on time will create a fault. Maybe that unit is too exposed to the wind, maybe short of gas or both. It will never defrost properly under those conditions.
@HVACRSurvival
@HVACRSurvival 3 года назад
This is the ghetto brand 😂. This was a generic run of the mill open / closed termination defrost control. It didn't have any thermistors whatsoever, heck they didn't even have the money to put an LED on the control 😂 . As long as that defrost switch was jumped like I had it, it should have ran the full 10 minutes 🤷‍♂️. I haven't heard back yet so it must have been the issue.
@larryproffitt4729
@larryproffitt4729 3 года назад
I just rewatched the video and it looks like you jumped between C and the top terminal (T2) instead of test (bottom terminal) and that caused a direct short on you first test. The jumper between T2 and DFT could have been left in place as it make the board think the sensor is constantly closed. When you done the test the second time you did jump C to test but the sensor was closed and that is why the unit went into defrost.
@HVACRSurvival
@HVACRSurvival 3 года назад
I just pulled out my computer so I could zoom in. YOU ARE CORRECT👍 I SCREWED UP. I'll have to remove my rant. Thanks for catching it👍👍
@Bryan-Hensley
@Bryan-Hensley 3 года назад
I've done the same thing, back in the 80s. Those models of defrost board are different from anything else..
@throttlebottle5906
@throttlebottle5906 3 года назад
yep, but looked like he jumped middle terminal to common, instead of the top, which I think is the feed from indoor thermostat B(heat reverse), to the defrost t-stat and T2 is the other side of defrost thermostat (I may have those backwards) but jumping either top or middle to C with defrost thermostat closed will short 24v to common. whoops, did somebody forget their glasses that day lol
@HVACRSurvival
@HVACRSurvival 3 года назад
@@throttlebottle5906 I had a comment concerning all these things at the top of the page of the comment section for nearly two weeks, I removed it after I did a live show which I noted in the same place and pinned that instead. if you notice the views of this video are off the chart compared to some of my other videos, that's why I did the live show, so if you want a in depth review of what happened and why, then watch that. If I altered every video so that I don't always came out perfect on top I wouldn't have any credibility. If I thought I was perfect I surely wouldn't put in the title "I messed up"..... shit happens, no one can know every different brand out there, and I went into the details of how their control board was completely back asswards to every control I've seen on the market. Here's the facts 👉 The problem is repaired and was completed before I finalized the job. Results are what matter,. 3 weeks later and I wasn't called back after 2 plus weeks of 0-15 degree days.
@jackgaming0592
@jackgaming0592 3 года назад
0:16 "Slightly Froze Up" is an understatement
@HVACRSurvival
@HVACRSurvival 3 года назад
That's my humor, you'll find that a lot in my videos. 😁
@AJ-ox8xy
@AJ-ox8xy 3 года назад
I'm by no means a veteran in the field but whenever I've come across this problem we just run it in cooling at the lowest setting and trick the thermostat by using a hair dryer or low temp heat gun close by it.
@douglas60040
@douglas60040 3 года назад
Good idea, but wouldn’t that freeze out the occupant?
@joecorbin5158
@joecorbin5158 3 года назад
Geez.... with all the videos of Walk ins and refer calls you guys do. A freakin heat pump had more ice on it than any of those ive watched.!!!!
@HVACRSurvival
@HVACRSurvival 3 года назад
It does happen time to time. 😁
@gordonwilloughby8793
@gordonwilloughby8793 3 года назад
Factory figured if they overstated the time they would get more boards replaced.
@HVACRSurvival
@HVACRSurvival 3 года назад
Hopefully not, but who knows?
@azr2d1
@azr2d1 3 года назад
"Don't do this electrical stuff if you don't know what you're doing" Says the guy blowing fuses......
@HVACRSurvival
@HVACRSurvival 3 года назад
First mistake I ever made 😲
@azr2d1
@azr2d1 3 года назад
@@HVACRSurvival ...since last time... lol
@HVACRSurvival
@HVACRSurvival 3 года назад
@@azr2d1 exactly right 🤣
@LRBennettInc
@LRBennettInc 2 года назад
I know this was a year ago. This was another quality video thank you for the tutorial of being safe and how to test the components. Danger is always present and you made it clear what those were. Also it's not ideal to be standing in wet conditions but we are committed to getting the system back on as a loyal tech should. Keep them coming thank you!
@HVACRSurvival
@HVACRSurvival 2 года назад
Thanks man! I screwed up but I'm not as familiar with this brand🤷. It happens, and any publicity is good from what they say. 😁
@LRBennettInc
@LRBennettInc 2 года назад
@@HVACRSurvival I own this POS and it's at my 2nd home on the Chesapeake and I have had nothing but trouble. My gauges have been on this thing more than any other customers house ever worked on. I admire your honesty it was a good laugh to hear you admit your issues. No one else does it like that. Thanks.
@HVACRSurvival
@HVACRSurvival 2 года назад
@@LRBennettInc I'm too honest, I rather apologize for being truthful than lying to you.
@bruceluiz
@bruceluiz 3 года назад
Exposed PCBs reminds me of old Soviet Union paraphernalia. I still cant believe a unite meant for outside exposure is so open to the elements.
@djrrmml7514
@djrrmml7514 3 года назад
Some smd components and conformal coating is something you would expect 2021.
@HVACRSurvival
@HVACRSurvival 3 года назад
This is a bottom of the barrel unit and is older. A lot of the newer equipment is surface mount.
@bruce8572
@bruce8572 2 года назад
I carried nothing but 80-30 defrost sensors in my van. Starts defrost at 30 degrees and terminates at 80 degrees. Guaranteed to get rid of all the frost/ice IF refrigerant is at proper level.
@HVACRSurvival
@HVACRSurvival 2 года назад
Who makes that? Most of the higher end equipment now has on demand defrost that I work on but sounds like that might be good for a universal part on the truck?
@mrfrenzy.
@mrfrenzy. 2 года назад
@@HVACRSurvival RS 222-8218 at least goes up to 60°
@zunar_j5_933
@zunar_j5_933 7 месяцев назад
Were the DFT and T2 jumpers just missing on the 2nd go? My brain read that goofy instruction sheet as needing those jumpers to meet the 10min defrost as well.
@throttlebottle5906
@throttlebottle5906 3 года назад
"don't be doing electrical if you don't know what your doing" he says shortly after blowing the fuse by jumping the wrong terminal to common :)) I just couldn't resist the temptation to poke lol. those three test terminals on board, the top is T2, the middle is defrost/test(jump top and middle together) and bottom is test which you jump to common to speed the defrost timer to seconds, vs. minutes setting of jumpers. jumping the top two together should be the same as defrost thermostat closed and it's likely directly connected to the defrost thermostat pins.
@HVACRSurvival
@HVACRSurvival 3 года назад
Shit happens but it makes for a better video. lol
@bruce8572
@bruce8572 2 года назад
Absolutely right.
@RonnieGibson-m9o
@RonnieGibson-m9o 8 месяцев назад
what about refrigerant levels? and pressures? I always melt all the ice, use your torch, let it sit for 20 minutes and then try heating mode with gauges on, pretend its new and in the factory without ice on it???? make sense?
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 года назад
It was totally iced over, hadn't been defrosting. Defrost timer was set for 30 minutes, which means a defrost will trigger every 30 minutes, the shortest period selectable. So based on the unit was completely iced, either the defrost cycle was terminating prematurely, or wasn't happening at all.
@HVACRSurvival
@HVACRSurvival 2 года назад
And that is controlled by the defrost control and termination 🤔 that's why I replaced them.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 года назад
@@HVACRSurvival Absolutely! ;)
@14312KIDS
@14312KIDS Год назад
Nordyne defrost boards are crap. I usually replace board and sensor. Just jump red to orange at CU. puts unit in cool mode to defrost out door coil. Tstat will bring on heat strips.
@publicmail2
@publicmail2 3 года назад
ICP, I get away with 90 mins in Florida on defrost, clearly a bad defrost board, I have not seen video yet. Mine from 2001 Heil has a thermistor to be cold enough for the defrost. That defrost board is cheap cost and other then thermostat for defrost given your symptoms that should fix it. I watched video now, that low RLA is normal when it's cold and no load on a 2.5T (it's running in cooling mode to defrost), you'd see 8 compressor plus 1 fan on a hot day in cooling. Of course you know this with your eyes closed...You where ok with board replacement even though it may have been stat only, the part does fail and in my case they came out with an improved version superseding, and it's the same board you have. In my case a lizard committed suicide on my defrost board and smoked it.
@HVACRSurvival
@HVACRSurvival 3 года назад
If I was in Florida market I would be using the 120 minute defrost or demand defrost (if I had a Carrier unit). The control board can't be sent back once it's been put on, this is one of many drawbacks of buying equipment from fly by night companies and expecting others to work on your equipment. I always tell my customers make sure you purchase from who you like doing business with. The company that sells the particular brand of equipment you choose will know the product best so be sure your ready to stay with them. In my area, Westinghouse and all the other Nordyne products are sold too about anyone with a contractor license. In my area Carrier, Lennox, Rheem, Trane are the big boys.
@catdash4390
@catdash4390 8 месяцев назад
Always blaming the installer 😂Modern HVAC systems are all a piece of shit😂😂
@shadowbanned69
@shadowbanned69 3 года назад
We had 2 nordynes at my work and there very wanky...they are the most crappy boards I've seen... next to a goodman🤭
@HVACRSurvival
@HVACRSurvival 3 года назад
I thought they were the same company until I looked it up. So I cut that out 🤣
@leso204
@leso204 Год назад
shurely a small plumers torch would have got the majority of ice off .........
@JoseRodriguez-xh6qo
@JoseRodriguez-xh6qo 4 месяца назад
Bad defrost board premature defrost termination.Read manufacturer data always.
@DIMTips
@DIMTips 3 года назад
I want to install one of these as side project. Good to know this is a problem
@jw3843
@jw3843 3 года назад
the unit could be low on refrigerant charge causing it to come out of defrost before the time is up by the defrost sensor or some other safety, not sure if there are any other safeties on this unit. Don't know if you checked the pressures, was not shown in the video. but in my experience that will cause units to freeze up and not defrost properly. had that issue on a trane and a few other brands.
@sprockkets
@sprockkets 2 года назад
At the end of the video it is snowing outside. What happens is the poor outdoor unit sucks in the snow, and cannot generate enough heat to remove the impacted snow. Happened to a mini split I put in for a friend. Of course we see below zero a lot so that didn't help. Whenever it snows heavy here I just turn mine off. I didn't thing I'd be using mine in the winter since I have gas heat, so I didn't put a protective shelter over it. But gas shot way way up so the heat pump is saving me money.
@stevecallachor
@stevecallachor Год назад
Thank the pioneers who commandeered these vast territories by driving off or killing the native inhabitants. “Come in your wagons”, said they. “we can live here in our millions” …………………….”If the electricity fails, half of you will die in the winter………………but that doesn’t matter, come anyway!!!” Stavros
@HVACRSurvival
@HVACRSurvival Год назад
Sounds about right, what made you say that?
@darrelllynn4270
@darrelllynn4270 3 года назад
should have just poured hot water over it
@brandonrutt2898
@brandonrutt2898 3 года назад
Just run it in ac and pull the wiring to the fan! Defrost as long as you like!
@myrkobalaban8571
@myrkobalaban8571 3 года назад
It was 59 in the house. Indoor coil will freeze.
@HVACExplorations
@HVACExplorations 3 года назад
Pressures would also be of concern.
@Bryan-Hensley
@Bryan-Hensley 3 года назад
@@myrkobalaban8571 no it won't in that amount of time.
@jamesrogers4674
@jamesrogers4674 3 года назад
Water hose.
@Bryan-Hensley
@Bryan-Hensley 3 года назад
@@jamesrogers4674 gosh that takes a long time on one like this. But it's about the only option however I've got a propane space heater I set in front of them if it has to be done right then. Around here I put them on emergency heat and wait a few days for them to melt if they'll let me. Some people don't agree to that. I'm talking about something frozen up like this one.. forced air space heater works pretty quick and you can stay warm too
@Bowhunters6go8xz6x
@Bowhunters6go8xz6x 7 месяцев назад
No way would I ever consider a Heat Pump as my sole home heat source if I lived where there is even remote chances of snow or single digit cold during winters. Just saying I like having a back up, either a gas furnace like in a dual fuel system or have an electrical Aux heat system.
@HVACRSurvival
@HVACRSurvival 7 месяцев назад
Most people have auxiliary heat with the heat pump
@mitchell8204
@mitchell8204 8 месяцев назад
Where did you get those jumpers? They look cool. I got a Kaiweets set and they are like 14 or 16 gauge with giant alligator clips and they work great except for small spaces.
@HVACRSurvival
@HVACRSurvival 8 месяцев назад
I built them with old test leads from a VOM
@adamrspears1981
@adamrspears1981 7 месяцев назад
I blame mcdonalds big mac
@HVACRSurvival
@HVACRSurvival 7 месяцев назад
Absolutely 🤣👍👍
@cameronprice931
@cameronprice931 Год назад
There’s too many hvac videos on RU-vid lol , all these homeowners gonna be trying to mess with their stuff and make our jobs harder , I wish there was an actual server for actual certified journeyman to actually discuss
@HVACRSurvival
@HVACRSurvival Год назад
Those type of people are going to do it either way, the problem is we don't have enough decent techs, this is my way of helping the rookies learn quicker.
@countryside8122
@countryside8122 8 месяцев назад
Mine froze up once during a cold blizzard and by the next day it was unfrozen and has worked great all through the cold and worked fine last summer. I purchased a Hessaire 18.000 unit. I installed it myself early last summer. So far ( knock on wood ) It has worked flawlessly. I never realized just how easy it was to install myself. This unit replaced an OLD samsung from the 70's that stopped working. Was simple to install as the hold to the outside matched perfectly. A dealer wanted $8,000 to replace my old unit with a 12,000 btu. I paid less than a thousand with delivery. Keep up with your great and informative videos.
@sherwinalvarez7365
@sherwinalvarez7365 3 года назад
I have a molex pin remover that works pretty good on those boards.
@sherwinalvarez7365
@sherwinalvarez7365 3 года назад
Male/Female 4 Pin Molex Power Connector Pin Remover Computer Wire Extractor Tool for Modding/Wiring/Sleeving (for .062" and 0.093" pins)
@HVACRSurvival
@HVACRSurvival 3 года назад
@@sherwinalvarez7365 I have a molex pin pushing tool, I'll have to see if that fits👍👍
@domrod1579
@domrod1579 3 года назад
I use a piece of 1/4” copper tubing
@HVACRSurvival
@HVACRSurvival 3 года назад
@@domrod1579 that might be my favorite one. I always have 1/4" 👍👍
@arcticarrowhvacr
@arcticarrowhvacr 3 года назад
Nordyne is made for mainly mobile homes so you know where the quality went for that.
@HVACRSurvival
@HVACRSurvival 3 года назад
I didn't want to say that and sound snotty. 😉
@danaeverhart6487
@danaeverhart6487 Год назад
You remind me of a HVAC tech that came to my home and shorted out my defrost board. He bought another one at his expense! Then I called a real Trane trained Service tech. Fixed it in less than thirty minutes. No offense implied !
@HVACRSurvival
@HVACRSurvival Год назад
None taken!
@nickboutin857
@nickboutin857 Год назад
Why would you not want to put the t in before the trap. All you have to do is put a cap on the top? Then your able to clean the trap super easily. This is how the company I'm with always does it?
@HVACRSurvival
@HVACRSurvival Год назад
There wasn't a cap on the tee that was the problem....
@jayxiao3
@jayxiao3 3 года назад
Bad high pressure switch might cut off the contactor too and cause premature defrost.
@horacegardner3516
@horacegardner3516 3 года назад
Slapping my forehead!
@Xanthopteryx
@Xanthopteryx Год назад
Why is US heating and cooling systems so sketchy? Always looks like something a kid has brought together.
@HVACRSurvival
@HVACRSurvival Год назад
Where are you and what do you use?
@christiandrumr80
@christiandrumr80 Год назад
I guess the build quality like most brands depends on whether its a base model or higher end. Mine is a 17 seer heatpump version of that, with 2 stages and variable speed furnace. It is completely different from a control / board perspective.
@tbrewer937
@tbrewer937 14 дней назад
I'm amazed you could get in touch with the factory
@HVACRSurvival
@HVACRSurvival 11 дней назад
Just gotta do a little digging 😁
@Kangenpower7
@Kangenpower7 Год назад
If it is above 30, defrosting with a garden hose will work well, I had to do that last week! I had a friend and installed a new compressor for them in September, and I guess they did not run the A/C for the remainder of summer. I forgot to plug the reversing valve back in, and came out in November to see it covered with ice like yours is. I was able to remove the 2" of ice in a few minutes with a garden hose. Also if above 34F, unplug the compressor common wire and then run just the fan motor, the ice will go away in about 15 minutes, like a air defrost of a walk in refrigerator. Great video, I am thinking that the board and temperature sensor should have been changed, and if you don't get more no cold calls, you did the right thing.
@superiorcomfortheatingairl4636
@superiorcomfortheatingairl4636 3 года назад
Thanks for sharing this video. Lucky for the customer that this was a copper & fin condenser coil, since then Nordyne went to all micro channel condensers for their Heat Pumps (Only Manufacturer who has done this). I have had one micro channel coil leak due to much ice built up.
@HVACRSurvival
@HVACRSurvival 3 года назад
I got my hands on the SolderWeild kit and it worked great on the aluminum I tested it on. I'm ready for a non-warranty coil to try it out on.
@sprockkets
@sprockkets 2 года назад
When I did work in 2010-2012 in FL I never came across a nordyne unit that had an issue. Trane? all the time. Carrier, to a lesser extent. I heard their micro channel stuff was bad. Kind of a shame since it seems like a good idea, at least for the inside.
@Sctronic209
@Sctronic209 3 года назад
Good information I personally don’t like working on heat pumps don’t do it enough to be good at it. Have a great day Rick.
@HVACRSurvival
@HVACRSurvival 3 года назад
Thanks for that👍👍. I've been working on the same job the last two days.
@Bryan-Hensley
@Bryan-Hensley 3 года назад
Heatpumps are 99.99 percent of what I work on.
@srenlund-hansen6883
@srenlund-hansen6883 2 года назад
do you have any kind of basic HVAC education ? you seem very DIY to me
@HVACRSurvival
@HVACRSurvival 2 года назад
Check out my other 220 videos and you tell me. If you can work on all the different types of things I do I would more than happily debate you on my creditably. If all I worked on was this piece of shit brand equipment then I would probably have known it better but I don't usually work on this brand.
@edwardsauer6084
@edwardsauer6084 3 года назад
We have a carrier green speed (expensive) that was icing up. Bge home came out and decided the thaw board wasn't working properly. Long story short, it's now the 23rd of February and they came out on the 6th and they still haven't been back. Called rhem 5 times and recieved 1 call back that they're working on the part. So after three 20 lb tanks of propane the weather has warmed up a bit so it's not freezing up. If you live in Maryland, bge home are not on it.
@jessemedsker2579
@jessemedsker2579 Год назад
Quick put the smoke back in
@CaptJerry
@CaptJerry Год назад
My open fire don't freeze up
@nathanielfox9721
@nathanielfox9721 2 года назад
The brand of it is amanda.
@fff-uc5pl
@fff-uc5pl 3 года назад
ever heard of a garden hose?
@rayanshkumarsingh9305
@rayanshkumarsingh9305 Год назад
It's a Westinghouse
@hillbilliesinthehood9472
@hillbilliesinthehood9472 2 года назад
Wow! It is better to keep your mouth closed and let people think you are a fool than to open it and remove all doubt. Mark Twain
@HVACRSurvival
@HVACRSurvival 2 года назад
7
@Stormchoirs
@Stormchoirs 2 года назад
In Florida, most installs are done with the T before the trap on most systems. Been that way for years. Depends on if the system is negative vs positive pressure as well. You can use a vent if you are feeling fancy.
@HVACRSurvival
@HVACRSurvival 2 года назад
I like tees over 90s in positive applications and a tee after a trap for a relief to preventing a double trapping.
@vacuumboy6.0
@vacuumboy6.0 3 года назад
Dang I want big mac now. 😂
@jrsmyth9761
@jrsmyth9761 2 года назад
A Bic pen with the ink removed goes over those plastic "pins" on many of the boards.
@davidhorsley1149
@davidhorsley1149 3 года назад
Thank an engineer for those instructions. There should be a requirement for licensure of engineers to serve an apprenticeship before entering school. Maybe then they could think like the people in the field and not like the stuFfed shirts a lot of them are.
@HVACRSurvival
@HVACRSurvival 3 года назад
I figured I was just reading it wrong but who knows. 😁🤷‍♂️
@davidhorsley1149
@davidhorsley1149 3 года назад
@@HVACRSurvival No, lawyers, engineers, and architects communicate in a convoluted way and it sometimes looks like they do it to keep themselves being needed.
@throttlebottle5906
@throttlebottle5906 3 года назад
the directions are OK, the board labeling is kind of funky, on the right side of pins it says "for test only" and the word TEST is directly above the middle pin, then on the left they say T2(top), DFT(middle) and TEST(bottom) in smaller text. jump top T2 to middle DFT(same as closed defrost thermostat), then temporary jump bottom TEST terminal to C until it reverses(speeds the timer up to seconds)
@markroderick9526
@markroderick9526 Год назад
shouldn't the title say i messed up not i missed up
@HVACRSurvival
@HVACRSurvival Год назад
Probably.
@myrkobalaban8571
@myrkobalaban8571 3 года назад
Why are they using a heat pump in the colder climates. Why not use a furnace? Too cold outside for heat pump.
@HVACRSurvival
@HVACRSurvival 3 года назад
What state do you live in? Do you have natural gas everywhere?
@ruvrandomusefulvideos
@ruvrandomusefulvideos 3 года назад
Just got my AC unit installed last November. I been watching videos about AC/heat pump, thanks for sharing
@HVACRSurvival
@HVACRSurvival 3 года назад
Thanks 4 watching👍👍
@joehead1294
@joehead1294 3 года назад
Westinghouse. Malfunctions built in before the name goes on. And how about that air filter? Sept 19, 2019> Man it's cold here in Texas!
@HVACRSurvival
@HVACRSurvival 3 года назад
All true😏👍👍
@Bryan-Hensley
@Bryan-Hensley 3 года назад
Aka Miller aka intertherm aka ducan
@duncansappliancerepair2141
@duncansappliancerepair2141 3 года назад
I use a ink pen case the solid kind to remove the the control board clip holders
@jawidofkoj2998
@jawidofkoj2998 3 года назад
I use needle nose pliers
@mikejovanovic1645
@mikejovanovic1645 3 года назад
I seen Steve lav use a bic pen to depress those pins on the old style boards
@HVACRSurvival
@HVACRSurvival 3 года назад
That would work👍
@mpurecat4155
@mpurecat4155 3 года назад
In my 10 years experience Nordyne are crappy pieces of trash. Boards often fail, had countless issues with motors dying less than 5 years in, sensors and safeties failing left right and center. Poorly made. Between Heil and Nordyne those two are my bottom of the barrel companies that I wouldn’t recommend even to those i dislike. I strongly urge customers to consider products that are better made. customers on average spend 20-35k on a car and make monthly payments, most companies have a 1 year instalment plan for most equipment furnaces run usually 5-7k installed and about 4-6k ac installed. If you spend that extra one thousand dollars you can still get a fairly inexpensive unit, won’t be the cheapest but generally speaking you get what you pay for. In my opinion if you can spend that on a car you can spend that on a piece of equipment, and most consider furnaces to be integral to a home, but when they skimp on getting something decent they shouldn’t be surprised.
@HVACRSurvival
@HVACRSurvival 3 года назад
You wouldn't believe how many people have commented like I'm crazy and have no idea how a heat pump works because I wasn't familiar with the Nordyne proprietary, 3 wire test function defrost control. We don't sell these and I had never worked or seen one in the 26 years I've been doing this. There was no instructions that told how the control worked other than what I seen on the cover, it was over complicated and I misplaced my jumper and blew the fuse. It's been several weeks since repairing this and we haven't had to return, It looks like I was correct in my repair 😏. You said exactly what I wanted to say but didn't want to come right out and say it because I don't make these videos to roast the equipment, I just show how I repair it. Thanks for the feedback!
@mpurecat4155
@mpurecat4155 3 года назад
First time i did one of their heat pumps I did the same thing, i blew a fuse exactly like how you did. they couldn’t have made the instructions any more convoluted because that’s exactly what it said to do and it blew. equipment that doesn’t come with clear and concise instructions is in my opinion already a sign that the manufacturer is cutting corners on every level. Carrier make it simple two pins you jumper together, no jumping to common required, that’s how they should all be done.
@HVACRSurvival
@HVACRSurvival 3 года назад
I agree and the fact that you can jump the defrost termination switch at the connection point on most control boards, how many times do you plan on needing that prong feature on the Nordyne board? Hopefully once or twice in it's lifetime. They must of planned on it failing a lot🤦‍♂️
@mpurecat4155
@mpurecat4155 3 года назад
Because i live in Canada and conditions are known to be harsh I’ve always been testing out the defrost function during all ac maintenances of said heat pumps. mind you it’s only really testing the board, but i have swapped out a few boards on a few brands, but at least it wasn’t during the winter
@1keykneedeep
@1keykneedeep Год назад
I still have questions about that compressor. Only drawing 4 amps ?? Thats definitely a problem.
@rileydavis435
@rileydavis435 Год назад
How was ur Big Mac that day? Lol
@HVACRSurvival
@HVACRSurvival Год назад
Lol. It wasn't mine, I wouldn't leave my trash laying around like that.
@hvacservicementor
@hvacservicementor 3 года назад
Nice job in poor conditions! All the DIYers need to know that while it may appear that he was safely touching all over energized equipment, his fingers were about two inches away from lethal voltage. Pros only!
@vinny142
@vinny142 3 года назад
And even the pro's need to stop doing that, really. I know it sounds cool to do something dangerous and then claim that you can do it because "I'm a professional", but really you're just being an idiot who thinks he can do things safelyt because he hasn't had the full 400 volt experience yet. If you tell people something is dangerous and then still do it, you're an idiot. Full stop.
@HVACRSurvival
@HVACRSurvival 3 года назад
You make me laugh. Viewers that quote 400 volts are the ones I have to worry about doing something wrong and trying to blame me because they didn't fully understand what they were doing. Show me 400 volts in the United States? 120v, 240v, 277v, 460v, is the most common I work on. And yes I have been hit with 277v. Go watch more videos and show me how you truly get nailed with 400v. Better yet start making videos to help technicians in the field that don't get enough training in our pathic school systems that come out lost and less than prepared to work in the field. If schools weren't so horribly under performing I wouldn't need to make videos. I don't make these to brag or to help cheap ass homeowners and business owners to save money. Thanks for your input that added no value to today's video👍👍
@grindstone5368
@grindstone5368 3 года назад
1st sticker always de energize eq before performing maintenance next sticker with eq energized jump j1 to t2 to enter test mode😂. Knowing the eq is the safety, being able to run diagnostics on energized eq is a far cry from an idiot.
@HVACRSurvival
@HVACRSurvival 3 года назад
@@grindstone5368 eureka Jeeves! you get it!!!👍👍🤣
@WolfeDRtrader
@WolfeDRtrader 3 года назад
hence why I never jump anything, while its HOT. Except the reversing valves on heat pumps, its safe enough. jumping has proven to be stupid when the circuits live... MY master tech above me blows fuses alot because of it
@glenmcgillivray4707
@glenmcgillivray4707 3 года назад
Jumping switches can be fine. Because you are just bypassing a single component. Jumping from common to circuits near sensors or neutral? Asking to burn or blow something. Better to bypass than jump.
@33turkeyman
@33turkeyman 3 года назад
i keep a painters tarp on my truck i wrap the unit and cover the top put it in defrost it will hold the heat in and melt the ice fast it works had a old school tech show me that 16 years ago i use it still to this day
@HVACRSurvival
@HVACRSurvival 3 года назад
So I wasn't too dumb 👍👍🙄😂
@33turkeyman
@33turkeyman 3 года назад
Nope you were halfway there I would have never thought of that until he showed me anything to help each other out we need all the tips and tricks we can get
@HVACRSurvival
@HVACRSurvival 3 года назад
True very true👍👍
@jessicawiseman4478
@jessicawiseman4478 8 месяцев назад
If like to see one of these on a Lenox
@HVACRSurvival
@HVACRSurvival 8 месяцев назад
Like to see what on a Lennox? Lennox is the brand I did the most right behind carrier.
@terrygrant8126
@terrygrant8126 2 года назад
Good job my friend....I appreciate you going the extra mile to see where the problem was located....Nordyne is terrible...
@HVACRSurvival
@HVACRSurvival 2 года назад
I'm glad I'm not the only one that feels that way. 😉👍👍
@grahamlangston2101
@grahamlangston2101 2 года назад
Lack of air flow or lack of gas we ran water chillers they cost more to run then the cost of water they saved and not that relayable
@denverbasshead
@denverbasshead Год назад
What brand do you like?
@HVACRSurvival
@HVACRSurvival Год назад
Carrier is fine, the install is just as important as the manufacturer.
@jesusischrist1527
@jesusischrist1527 3 года назад
Can you not just move the relay /delay from 30 to 90 to allow appropriate timing between heating intervals ?
@HVACRSurvival
@HVACRSurvival 3 года назад
90 minutes would let it run longer between defrosts resulting in more ice between defrost.
@David.rivas.alexis
@David.rivas.alexis 3 года назад
I really appreciate these types of videos. the process of your troubleshooting helps me to refine my technique. And watching the videos all the way through is like a mini movie: First you have conflict and then either there's a solution at the end or its open ended and we will never know but we can always have many theories and alternative routes to the same solution.
@HVACRSurvival
@HVACRSurvival 3 года назад
Thank you, this is a recording while I'm figuring it out instead of telling you what I found after the fact. So yeah I could see it being like a movie. the only problem I run into is those who want to prove their excellence and try to guess what's wrong before they even watch the video 🤯 which I find to be kind of pointless but to each their own. I appreciate you taking the time to watch it 👍👍
@SciaticaDrums
@SciaticaDrums Год назад
They need to be up off the ground with a shelter over them in colder areas. Mine is on two foot high concrete pylons with a shelter over it. No issues so far. It's in central NH.
@doublezmtnman
@doublezmtnman Год назад
I installed Westinghouse for a few years and was plagued by leaking coils, and service valves
@KadirYildiran
@KadirYildiran 3 года назад
👍👍👍 few days ago it was very cold in here. A 24000BTU inverter mini split outdoor unit freezes in this way. People who used it unconsciously and thoughtlessly pierced the condenser coils with some kind of builder's hammer that we "cut" while clearing the ice. Although it looked bad, I tried to fix it. I wanted to share something like this.
@HVACRSurvival
@HVACRSurvival 3 года назад
Heck yeah, share it👍👍
@frankroper3274
@frankroper3274 Год назад
I would have pulled the fan wire off the contactor on one side and went to the tstat and put it on 55 F to defrost it and if the board had a flashing light I would see what the code was saying. If the ice sensor was calling I would order a new defrost board.
@SovereignTroll
@SovereignTroll 2 года назад
So many places heat pumps of SEAR 16 or less are too far north. Now ductless splits are replacing these and can work with low ambients. Defrost boards don't seem to like power surges and dirty power either...
@HVACRSurvival
@HVACRSurvival 2 года назад
Several manufacturers have inverter driven heat pumps that work fine down to 0*. You need to look at the eer rating not the sear rating when you want to know you're efficiency of your heat pump in heating. It costs more to heat my house then cool it.
@SovereignTroll
@SovereignTroll 2 года назад
@@HVACRSurvival Yes Sir. I am placing a ductless mini in own residence this summer. 22-24 SEER awesome and lower tipping point. USA behind on this and lower energy consumption will push this probably.
@toddthegamer
@toddthegamer 3 года назад
i though ac's ice up bad, apparently heat pumps do as well!
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld 3 года назад
they are the same thing.
@toddthegamer
@toddthegamer 3 года назад
@@SupremeRuleroftheWorld yeah, very true
@maxeyac
@maxeyac 3 года назад
who's been eating a big mac?
@HVACRSurvival
@HVACRSurvival 3 года назад
It was trash that blew into the yard. It wasn't mine.
@chuckdearruda6271
@chuckdearruda6271 3 года назад
Believe I would have figured out why the blower was not running before leaving the crawl space the first time.. Without the blower you can’t get Emergency Heat, Aux Heat, or defrost to work.
@HVACRSurvival
@HVACRSurvival 3 года назад
I believe it was because the outside unit had the test pins jumped and the thermostat had not came out of a 5 min delay.
@snpdg1
@snpdg1 3 года назад
You were in defrost , so yes it is normal that the blower doesnt run . You dont wanna get cold air inside the house. When your first objective is to heat
@HVACRSurvival
@HVACRSurvival 3 года назад
@@snpdg1 that would be the first system I've seen that doesn't run the fan during a defrost. From what I'm learning about this POS defrost board, it wouldn't surprise me.
@snpdg1
@snpdg1 3 года назад
@@rottiev264 nicely true
@HVACGUY
@HVACGUY 2 года назад
Gotta hate it when you blow a fuse, and it’s in a crawl space. Lmao 😂
@HVACRSurvival
@HVACRSurvival 2 года назад
Yeah! This is my most viewed video and it's on a brand I wasn't familiar with🤦🏻. What could go wrong 🤣
@joeshearer1247
@joeshearer1247 3 года назад
When you short the test pins and rapidly advance the internal clock you can eat into the 10mins defrost cycle and it terminated less than 10mins
@HVACRSurvival
@HVACRSurvival 3 года назад
I pulled the jumper as soon as it went into defrost but you might have a point👍👍
@AMDRADEONRUBY
@AMDRADEONRUBY 3 года назад
Same part the HVAC guy did change on my 13 years old Amana Heatpump. Sometimes the heatpump was stuck in defrost mode or staying in defrost and starting the fan so it was in Cooling mode but asking for heat nice videos. For my part I did change my filter every single 3 months
@3v068
@3v068 Год назад
I appreciate learning these kinds of things, even though I probably would never do this myself and would just hire a professional if i needed it. Hell, my first thought would have been to get a portable generator with a hair dryer and just give it a few hours and some run overs lol.
@joeshaffer2506
@joeshaffer2506 Год назад
I really been thinking on putting one in my house but what I’ve seen lines come 25’ but my home is 30’x75’ slab ranch 9 total rooms had central air but out side condenser froze up and stopped working thinking of changing it out with a heat pump
@HVACRSurvival
@HVACRSurvival Год назад
Linesets can be extended to what ever the manufacture has listed as the maximum length.
@joshuabest100
@joshuabest100 3 года назад
A good way to get them pins off the board is a bic pen take the ink out and use that
@HVACRSurvival
@HVACRSurvival 3 года назад
Good point👍👍
@Sctronic209
@Sctronic209 3 года назад
Have you heard of Fluke 902fc having problems? Johnstone called me and said I need to stop using my meter per Fluke. Just certain serial numbers.
@HVACRSurvival
@HVACRSurvival 3 года назад
No, that's weird. Did they say what the problem was? It's go to Flukes website and verify
@Sctronic209
@Sctronic209 3 года назад
The Counter guy at Johnstone said they can catch fire. I looked at the fluke website found nothing. They must be trying to figure out what the cause was. This was Johnstone supply Davenport Iowa.
@Sctronic209
@Sctronic209 3 года назад
support/safety-notices/37xfc-902fc-recall
@redneckways1617
@redneckways1617 2 года назад
Bet that unit is low on refrigerant with a leaking evaporator coil also
@marvin7048
@marvin7048 Год назад
As the great Ernest once said " heat pump schmeat pump"
@HVACRSurvival
@HVACRSurvival Год назад
good one!
@DanielWilliams-lx7fg
@DanielWilliams-lx7fg 2 года назад
In a climate that gets snow hear pump is trash furnace is king also heat pumps runs the electric bill sky high. When i lived in colorado we had a furnace now I live in virginia with a heat pump and am considering get a gas run to the house
@HVACRSurvival
@HVACRSurvival 2 года назад
Depends what state you live in what your electricity will cost and whether or not you have natural gas available but even then natural gases went sky high thanks to bad decisions of other people.
@trinito97
@trinito97 3 года назад
I don’t like heat pumps Imagine eliminating all gas furnaces and having 100% heat pump Here in California all new Contruction are using this things, specially the ceiling type air handler Alway leaking, noisy, braking down in less than a couple years, if it gets below 35 degrees the heat sucks Sorry for the ones that are in favor of climate deal
@HVACRSurvival
@HVACRSurvival 3 года назад
Me neither 👍👍
@WolfeDRtrader
@WolfeDRtrader 3 года назад
that would suck. Thats bidens plan. Let me safe, heat pumps rarely run great for YEARS. I get many heat pump no heats.
@fw2222
@fw2222 2 года назад
You should measure the contacts before you short them.
@HVACRSurvival
@HVACRSurvival 2 года назад
Hindsights is 20/20
@JonnyMudMower
@JonnyMudMower 3 года назад
Big Mac
@HVACRSurvival
@HVACRSurvival 3 года назад
Two all beef patties, special sauce, pickle, onion, lettuce on a sesame seed bun 🤦‍♂️
@AlexanderWright1
@AlexanderWright1 2 года назад
This is where a kettle would be handy ;-)
@hakimam9864
@hakimam9864 Год назад
Had same issue Changed the defrost sensor that I got from Amazon and the issue was fixed Now sometimes temperatures drop under 20 degrees and no ice at all
@HVACRSurvival
@HVACRSurvival Год назад
Good Deal..
Далее
Meat Case Is Warm! Fix It Today Please...
22:10
Просмотров 20 тыс.
Heat Pump Defrost Board Troubleshooting Tips
9:26
Просмотров 41 тыс.
КАК БОМЖУ ЗАРАБОТАТЬ НА ТАЧКУ
1:36:32
2 Bad Compressors In Weeks WHY? Freezer Down
29:40
Просмотров 21 тыс.
THE ICE MACHINE IS EMPTY
16:04
Просмотров 76 тыс.
What's inside a Heat Pump?
23:47
Просмотров 5 тыс.
Double Compressor Failure Was Not Enough Excitement
24:37
Rheem Heat Pump Freezing in the Heat Mode
34:22
Просмотров 17 тыс.
More Mistakes More Problems New Install Failures
33:14
Mining Magnetite
16:20
Просмотров 314 тыс.
The GIGA JUKE is dead.
28:02
Просмотров 15 тыс.
Heat Pumps: the Future of Home Heating
35:15
Просмотров 4 млн
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 34 тыс.