Welcome to HVAC with John Israel RU-vid Channel. On this channel I Bring you along on HVAC Service calls, HVAC Installs, HVAC Maintenance and pretty much anything else HVAC related. Enjoy and thanks for watching.
John on your probe placement, high side to discharge, low side to true suction. You gave me advice a few years ago placement on probes on a package unit located the liquid line before he hit the metering device. I really appreciated it because you didn't give a smart ass comment about not knowing, having expensive tools but not knowing how to operate them correctly.
Excellent informational video and a great example of how to run a business. Great customer service with the lady as she "helicoptered" and you were able to still keep describing enough of what you're doing for the camera. Fantastic work! New sub.
Great presentation. I picked up some good points from you. I appreciate the removable panels on the Rheem and Ruud units. It allows for more thorough cleaning. Keep it up.
I was a little concerned about the mixed reviews, but I used it last year and hooked it up again this year and it was great ru-vid.comUgkx-izdrK3eF-HMvjzeBOxToD6Fx-4ulJUh . I couldn't get my 10' Intex pool above 76 degrees the year prior and last year I got it to 90 and had to put ice in it. This worked so well! I have just 1 mat hooked up to a 1,000 GPH Intex pump and it makes a significant reduction in the flow rate coming back into the pool, but that is to be expected with how far the water has to travel through the mat.
thnx for ur video. Maybe u can assist me. Do you know, what is a "high pressure lockout"? And could a defective thermostat caused the defrost board to show this code. My heat pump board is currently showing this code. The OUTDOOR unit DOES NOT, start up at all, in heating or cooling. There is 24v on the R and C terminals. In the "emergency" mode, I am not getting enough heat. It only heats up to 72degrees only, and runs all night. And never shuts off. This is a RHEEM system. 6yrs old. I am really frustrated now, because i am having all these issues at the same time. I am thinking the thermostat is mal functioning, then I think its the defrost board. then i think the heat strips has issues. I am a wreck with these issues. The indoor unit runs fine, but NOTHING from the OUT DOOR UNIT. I just can't figure it out. Hope you or any other can assist me.
Good video brother and I hate to criticize but you shouldn't be putting your probes in the dirt before you use them or ever for that matter, appreciate what you do though and keep up the good work
John - does Rheem/Ruud have a communicating high efficiency system similar to the Carrier Infinity? I’m in South Alabama with a high humidity climate. My old 19 year system is failing and I want a high efficiency system to control temp and humidity.
Hey sir, my ac fan outside willl turn on when I put it on cool but off when I put it in heat. Is that even normal? Also my house produce very little amount of heat. Already changed the run and start capacitor but still litttle amount of heat. N yes the fan still won't turn on after I changed the capacitors. Any idea?
if you up grade the heat unit in your Heat system with a 15 instead of the standard 10 heat unit, will it make it hotter when the heat is on. Like a thermostat does on a car?
I have a problem with my water source heat pump. Works in cooling with good superheat and subcooling but when you run heating, it will be low suction and low hi pressure with high superheat. What do you think is wrong with it?
I wish you was in Arlington Texas, because I have a heat pump I bought it Nov 2021 and a few days later my heat clicked off and the company I bought it from, his workers who installed it would not come back to see what was the problem, I had to run it on emergency heat, the owner of the company have cancer and kept asking me to bare with him that he promised to get it fix until this day 2024 he never did, so Oct. 2022 I had a company to come out they said it was a leak and charged me $712 and before the gentleman got out my subdivision my heat clicked off again, I hurried to call the company and they sent someone out the next day and that person said it was some type of value and the owner said it was a $2,700 job and said it would be best to get a new unit because I was sold a bad unit 😯I told them that's ok and my unit still don't work on regular heat I got to run it on emergency heat because I have not found a company I feel I can trust. I'm afraid of companies charging me again and not fixing the problem.
Look how many replies you’ve gotten!! ZERO!! Cause we are all tired of assholes like you. Mr fucking super tech who thinks he’s better than everyone else. Just get the Fuck out of here no one wants you around.
@@johnisraelhvac2019 HAHA what are you talking about "super tech " nonsense im just a filter changing new guy ...PROBABLY missed the -- if any-- part. good response though made my day
Don't ass-ume that a future customer whom you have never met is going to be a pain in the buttaco. The woman just needs service. The attitude you bring to a job is 90% of how customers will react to you. It is very important to be positive and professional in any service to industry, or at least neutral. That future customer might somehow be your lifeline in the future...you never know. You got an annual customer for maintenance out of the Rheem warranty referral
I forgot to say the Air runs fine no problem with it, it's just when I turn on the heat on the regular setting it come on and run about 5 minutes and clicks off it do that every winter that's why I have to run the emergency heat.
Hi John we have electric heating with air handler in ceiling and whenheat is on it appears our Lennox ac unit comes on also. Is this a bad wiring or could it be correct. I have been living in this home 2 years and never notice. If you could give your thoughts . Tia Ps how do you tell a heat pump ac unit?