Тёмный

How and Why to Flush Your Heating - Easy DIY 

The Diligent DIYer
Подписаться 12 тыс.
Просмотров 68 тыс.
50% 1

Tools Amazon affiliate links:
- DeWalt 18V Torch - amzn.to/42atv6K
- Knipex plier wrench - amzn.to/3yvYWKT
- Bahco pipe reamer - amzn.to/3mOckrm
How and why to flush your central heating system for DIYERs.
#diy
#plumbing
#plumber
#heating
#centralheating

Хобби

Опубликовано:

 

26 апр 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 76   
@joncole1445
@joncole1445 3 месяца назад
Thank you for taking the time to make and share this video! 😊
@TheDiligentDIYer1759
@TheDiligentDIYer1759 3 месяца назад
Thanks for watching!
@tomroguk
@tomroguk 5 месяцев назад
Appreciated the explanation of the different cleaning products.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 5 месяцев назад
Glad it was helpful!
@kpatel8549
@kpatel8549 9 месяцев назад
Thank you for sharing this video I appreciate your time 🙏🏻
@TheDiligentDIYer1759
@TheDiligentDIYer1759 9 месяцев назад
Thank you for watching, very appreciated!!
@Jane-bd3kn
@Jane-bd3kn 28 дней назад
Great video. Thanks so much.
@ruheluddin9384
@ruheluddin9384 7 месяцев назад
Fantastic video thank you!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Thanks for watching!!
@errolmagill1611
@errolmagill1611 Год назад
👍 Some very good tips - thanks. 😊
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Год назад
Thanks Errol!
@drmoonie
@drmoonie Год назад
Best yet 👍
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Год назад
Thank you!
@vman2kay
@vman2kay Год назад
Get a £20 massage gun with the foam ball end and use that to vibrate the radiator, cheap alternative if you don't have an SDS or the attachment is too expensive.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Год назад
Great idea, thanks!
@darrenforward8277
@darrenforward8277 Год назад
Great Idea where from ?
@vman2kay
@vman2kay Год назад
@@darrenforward8277 I tried replying but my comment seems to have been deleted. Any massage gun with the ball end will do.
@girlsdrinkfeck
@girlsdrinkfeck 7 месяцев назад
@@vman2kay hitachi ?
@danm8004
@danm8004 6 месяцев назад
​@@girlsdrinkfecknice.
@girlsdrinkfeck
@girlsdrinkfeck 7 месяцев назад
10:28 i like how it has dual valves , incase one fails ,my combi boiler only has one on its refil loop which is pretty bad if it goes tits up
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Thanks for watching!
@shadowdugify
@shadowdugify 7 месяцев назад
Really like this idea, I was thinking of getting one of the drain cocks open all the time and flushing the water through. Would I still need to turn off the thermostat and lock on each radiator in turn, I pressume to keep pressure up in that single radiator to remove the gunk?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Thanks! Yep you’ll need to isolate all radiators and open one at a time to get a good blast through. You only need to close the valve on one side of the rad to turn it off though, no need to do both sides. Thanks for watching!
@CAR_SOLUTIONS
@CAR_SOLUTIONS 7 месяцев назад
I’ve got a combi boiler is the process the same by leaving the filler loop on and letting it get full whilst draining it? Do both lock-shield and trv need to be off or just the trv will be sufficient? Do you use just a normal drain off point for the water to just come out? I’ve only got one drain off point on a 15mm copper pipe by the front door will that work?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Yep same process with filling loop on and drain open. Only need to turn one rad valve off per rad, not necessary to turn off lock shield and trv. Yes your drain off will work. Thanks for watching!
@dejanmyrtaj1997
@dejanmyrtaj1997 Год назад
I wanted to ask if it is easy or difficult to install central heating as a beginner who has finished the 4 month school for hvac systems, where should we base ourselves
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Год назад
Depends on the complexity of the system and your skill set really
@derekbell4173
@derekbell4173 7 месяцев назад
Despite having the ch system flushed when a new condensing boiler was installed I still need the pump on maximum speed to reach the required circulation for the boiler to function. Do you think using the x800 would help or do I need a powerflush?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Seems odd that you would need the pump on full just to get the circulation needed, you may have a blockage or pipes that have a lot of debris in them. You usually get the most build up in any bends just before the pump, you could try cutting out a short section of pipe to look, clean it out and solder it back in using slip couplers. If you haven’t got a magna clean, I’d fit one of those on the return before the boiler too. Thanks for watching!
@TelstarTAK
@TelstarTAK 8 месяцев назад
Thanks for an informative video. When you've treated with X800 for an hour on full heat, we have a drain point at one of the radiators. Should we just drain the whole system and then refill the whole system? Not sure how to 'blast' one radiator at a time - what is the sequence exactly - are you sending refill water to one radiator at a time, then draining system each time and closing off to do the next radiator, before finally refilling the whole system?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 месяцев назад
You need to flush the X800 out, just draining the system will still likely leave a lot of cleaner sat in the pipes. Easiest way is to turn all the radiators off at the lock shield or trv, then turn them on one by one, with the filling loop turned on max and a drain off open. The best way though is to take your filter off and put hoses onto the flow and return then flush from there using the hose pipe. If you haven’t got a filter though, you’d have to cut tees into the flow and return by your boiler.
@iansharp0306
@iansharp0306 8 месяцев назад
If I drain down to remove cleaner, could I the refill system and drain down again. Would this remove all cleaner from rads and pipe work, rather than doing each rad individually? Thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 месяцев назад
Unlikely you’d get it all out in my opinion, you need the flush to get all the rubbish out of the system really
@iansharp0306
@iansharp0306 8 месяцев назад
Thanks, my boiler and magnacleanse filter are in my loft and not easy to get hosepipe up there. Can I do a mains flush using a hosepipe attached to a radiator. If so can you explain what I have to do. Sorry to be a pain, I appreciate you are probably v busy.
@nigelburbage7803
@nigelburbage7803 7 месяцев назад
I have underfloor heating as well as numerous radiators upstairs and down. Does this complicate things when attempting a system flush?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
You might need more cleaner as you have a lot more water, but the principles are the same. Thanks for watching!
@jakebarnes3054
@jakebarnes3054 7 месяцев назад
At 8:22 you talk about flushing both the flow and return as opposed to just one- is there anywhere else I can find information about this? Does this only apply to the radiator which is being used to drain down the system? This is the only bit I'm unsure about in your otherwise very informative and helpful video. I'm dealing with a very clogged up central heating system so I want to get it cleaned up as well as possible and this seems rather relevant to flushing as effectively as possible, if you could extrapolate on this I would appreciate it- I've not seen this mentioned anywhere else. Thanks.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
That was more unique to my system design where the filling loop is on the return and I was draining off the return, so I don’t want to just drain that half of the system, and ignore the flow side. It will depend where your fill and drainoffs are located. You essentially want the water to go up one way and come back the other to a drain, in order to flush the system out. Sorry if that wasn’t helpful!
@jakebarnes3054
@jakebarnes3054 7 месяцев назад
@@TheDiligentDIYer1759 I see, thanks!
@jakebarnes3054
@jakebarnes3054 7 месяцев назад
Do you drain the system after finishing with the cleaning solution? You didn't specify but I'm assuming you would do this before adding the inhibitor unless I'm mistaken, please let me know.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Yes you effectively drain it all out when you do the flush. The idea is that you put the cleaner in, run the system hot for a while, that lifts all the dirt into a suspension. Then you flush with mains water, one radiator at a time to get all the cleaner and dirt out.
@jakebarnes3054
@jakebarnes3054 7 месяцев назад
@@TheDiligentDIYer1759 cheers. Appreciate it.
@GotMoreCakes
@GotMoreCakes 6 месяцев назад
Could I just add the inhibitor directly in to the magnaclean filter since I need to clean mine off anyway? let it pump around a bit then add whatever is left? Also, nice pipe work :)
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 месяцев назад
Yep you can use your magnaclean as a dosing pot. If you don’t have a towel rad you can put a funnel in, using the magnaclean is a good alternative. Thank you! And thanks for watching!
@GotMoreCakes
@GotMoreCakes 6 месяцев назад
@@TheDiligentDIYer1759 Cheers chap I'll sort that out tomorrow then. Have a great christmas :)
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 месяцев назад
Thanks, you too!
@raj080288
@raj080288 2 месяца назад
My hot water is luke warm, what could be the cauad of this?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 2 месяца назад
Very difficult to say without a lot more information or seeing your system. Probably best to get a plumber round if you’re not able to work it out. Thanks for watching!
@raj080288
@raj080288 2 месяца назад
​@@TheDiligentDIYer1759so mine is a vaillant ecotec combi boiler. W The radiators heat up fine but the hot water from the tap is not piping hot, but just luke warm. Does it sounds like the heat exchanger plate that has maybe scaled?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 2 месяца назад
Yes you’re probably right or a broken sensor, either way I think it will be a job that needs a professional in unfortunately
@raj080288
@raj080288 2 месяца назад
@@TheDiligentDIYer1759 thanks mate. Appreciate it. Keep the content coming!
@rogerspicer3927
@rogerspicer3927 8 месяцев назад
Brilliant Vid ! Are you a plumber by trade ?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 месяцев назад
I’m not in the trade at all actually, just an over enthusiastic DIYer. Thanks for watching!
@girlsdrinkfeck
@girlsdrinkfeck 7 месяцев назад
my parents used to fluish their own, but it takes hours , cheaper to hire a pro to do it IMO, time is money and the pros add in the chemicals in
@jakebarnes3054
@jakebarnes3054 7 месяцев назад
If you have money, yeah, hire a professional. If you don't, like many of us, DIY.
@girlsdrinkfeck
@girlsdrinkfeck 7 месяцев назад
@@jakebarnes3054 just do overtime
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
Not every job allows over time, and some people enjoy doing things themselves too.
@johnbower
@johnbower 5 месяцев назад
Most so called pro's are doing the job to make money not to do the job properly
@mrjimbo2920
@mrjimbo2920 3 месяца назад
X800 is not recommended unless you thoroughly flush out.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 3 месяца назад
Agreed, but i do in this video. Thanks for watching!
@mikegreen3395
@mikegreen3395 5 месяцев назад
Dare you to turn that pump valve off
@TheDiligentDIYer1759
@TheDiligentDIYer1759 5 месяцев назад
No reason to - thanks for watching
@L4WNY..
@L4WNY.. 7 месяцев назад
Ive just had the gas people out, theyve quoted £850 to flush my radiators 😤
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 месяцев назад
That is a fortune! Definitely a job that can be done DIY. Thanks for watching !
@L4WNY..
@L4WNY.. 7 месяцев назад
@@TheDiligentDIYer1759 I got home and used the massage gun technique 👌 🥳
@davidkneale7455
@davidkneale7455 7 месяцев назад
I hope you have knee pads in! We never wore them when we were younger but I'm struggling now after 50 years plumbing!
@brianmarkie4667
@brianmarkie4667 7 месяцев назад
I've just had a quote of £880 for a flush. I will be doing my own 😮
@gardgas1
@gardgas1 5 месяцев назад
Having a professional carry out your flush is the best and safest option, yes, you MIGHT think you can do it, but, I bet you wouldn't be doing it properly. Some companies quote £100 per rad, which is ridiculous, but it is a costly job, ideally most system should take all day, which is labour, normally a flush cost between £500 -£600, but that's all time dependant. If you suddenly rupture a joint because of excess pressure, will you fix it?
@gardgas1
@gardgas1 5 месяцев назад
Although i applaud you on one hand, i would NEVER advise anybody to mains flush their own heating system for various reasons, yes, you might have some money, but just how good of a job are you actually doing without knowing the full ins and out of a heating system, plus, without having somebody check your system could actually stand up to mains pressure, you could cause more problems than your solve, thus needing and engineer to repair anyway. Like i said, informative, but not recommended
@TheDiligentDIYer1759
@TheDiligentDIYer1759 5 месяцев назад
Thanks for watching!
@straty5598
@straty5598 6 месяцев назад
What the hell you got on your feet bro???
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 месяцев назад
Crocs haha, they are my garden shoes, i wouldn’t wear them out the house. Thanks for watching!
@straty5598
@straty5598 6 месяцев назад
@@TheDiligentDIYer1759 they send a shiver down my spine, have some self respect man!!! Canny vid
Далее
How to power flush central heating system
16:42
Просмотров 79 тыс.
DO NOT Dunk Here ❌🏀
00:20
Просмотров 8 млн
HOW TO REMOVE RADIATOR SLUDGE - Plumbing Tips
6:59
Просмотров 871 тыс.
HOW To flush a heating system with mains water easily!
3:59
DIY Central Heating System Radiator Flushing.
19:05
Просмотров 13 тыс.
Get More Heat From Your Radiators ~ System Balance
16:36
Ноги После 160км
0:18
Просмотров 502 тыс.
Which water gun won??
0:30
Просмотров 74 млн