Тёмный
No video :(

How does my plumbing look? Professional plumber feed back! 

Meltin Metal Anthony
Подписаться 97 тыс.
Просмотров 3,1 тыс.
50% 1

#plumbing I’m building my own house and can’t get much help. I wanted to get some feed back from professional plumbers on here and see what you think! Thanks for watching

Опубликовано:

 

30 июн 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 50   
@johndorazio3759
@johndorazio3759 Год назад
Looks good take your time make the pipes more plum but it should work fine the country needs more people like you
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thanks bud
@SolarSeeker45
@SolarSeeker45 Год назад
Looks good to me. The only important thing to remember with drain lines is 1 inch of drop per foot on the horizontal pipes. If you do any steeper or less steep then you'll be getting repeated clogging.
@justintasht1067
@justintasht1067 Год назад
Looking good and coming along well 👍👍👍
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thanks 👍
@youtubeisfullofspam7068
@youtubeisfullofspam7068 Год назад
I did some drainlines for out house black water . On horizontal runs drop should be 1/8 to 1/4 every 10 foot . Convert that to the length of your runs & make sure it's right . ( Clean ) Water lines don't really matter because they're pressurized
@whatsnextgarage
@whatsnextgarage Год назад
Hey Rockstar, Happy fourth! Judging by some of the comments you got a working system! Well done! Keep that pedal down and the great welding info flowing! See ya on the next one!
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thanks Dave ! I’ll do my best! Always look forward to seeing your comments!
@jc8417
@jc8417 Год назад
Crap in it n see what happens
@justinmackenzie824
@justinmackenzie824 Год назад
I agree. Only way to know
@grumpyguys4082
@grumpyguys4082 Год назад
"Can't see it from my house"!
@peteratos660
@peteratos660 Год назад
Over all it looks like it will work well. You over complicate some parts of the system but that’s just not doing it for a living. I would add some support bracing on the horizontal drain lines. I’m Illinois your required to brace the pipe every 4 ft. Also, I would have added a clean out between 12 and 18 inches off the ground on the main drain line. It’s not fun to try to run a rod when your standing 5 ft off the ground on a ladder. I’m general one of the better “homeowner” plumbing jobs I’ve seen in a while.
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thank you! And I tend to over complicate things. I do own a man lift so I’ll cruise over in that puppy if I need to clean it out
@mikeznel6048
@mikeznel6048 Год назад
Looks great. Takes skill to get it all together in the studs and have it all line up and pitch and seat the joints all the way. You gonna exfil or air test it?
@flamingskoda
@flamingskoda Год назад
Looks good. Here in UK you don't have to vent every appliance. I plumbed my own house in 2011. I put plenty of access panels and rodding points in.
@bricebeaulac
@bricebeaulac Год назад
Yeah it’s the same in the US lmfao
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
But it should work ? I had to vent the tub and shower separately because what I read was if using 2” and it’s more than 5 ft away from main vent it needs its own
@flamingskoda
@flamingskoda Год назад
@@MeltinMetalAnthony I'm not familiar with your codes in USA but it can't hurt to have more vents. You've got a good work ethic.
@michaelc9507
@michaelc9507 Год назад
Your plumbing is just like old people fucking not to good😛 Nice work man
@mikev.1034
@mikev.1034 Год назад
👍👍
@scottjune3554
@scottjune3554 Год назад
As a plumber plumbing should be plumb that's why it is called plumbing stick to welding 😊
@basic00001
@basic00001 Год назад
shit looks plum from here bud...
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Well does it look like it will work well? Should I not have gone diagonal through the walls?
@scottjune3554
@scottjune3554 Год назад
Oh no it will drain you did really good for not doing it before
@clintcowles7563
@clintcowles7563 Год назад
Nice work man. Keep it up!
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thanks, will do!
@JustinTopp
@JustinTopp Год назад
1:24 the tee for the vent is upside down. Doesn’t really matter but it wouldn’t pass inspection here. Don’t need a long sweep on the vent either but that doesn’t make any difference. I would’ve also just used a tee for the upstairs sink rather than a wye and the 45. Should be fine though. Overall I think it looks good. I’ve seen worse from actual plumbers hah. I’m not by any means a professional, but I did do a year of residential new construction plumbing before I left to go to welding school. Good stuff Oh yeah, don’t forget the nail plates
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Oh ya! Definitely won’t forget those. Seen a TV installation guy run a screw into a vent. People couldn’t figure why it stunk!
@KingBigBabyJesus
@KingBigBabyJesus Год назад
12" centr on them floor joists? Might have to go check out some more of those build videos. Plumbing looks like its gonna keep the poop movin the right direction tho
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Actually 8” on center lmao. To support the tub, fire place and shower. The tub is right above the far wall these are 9.5 joists so I was extra careful
@charliehuntsman9827
@charliehuntsman9827 Год назад
Looks good bro just make sure you have access panels where you need them when you dry wall so you don't fuck yourself. Please ask me how I know 😂
@osbaldohernandez9174
@osbaldohernandez9174 Год назад
How do you know
@charliehuntsman9827
@charliehuntsman9827 Год назад
@@osbaldohernandez9174 just was remodeling my wife's and I new house we put in a new shower surround did all pex and thought we had everything good to go turned everything on and checked for leaks before drywalling back in and putting the surround up crossed my mind to cut in a quick access obviously didn't and we had a damn leak had to go back in and fix one of the connections obviously then we put a quick access panels in . Obviously it doesn't matter when you do it really just gives you peace of mind when you do it before and the fact you have them there and don't half to f with it . Just my 2 cents.
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
I’m thinking on just putting a few pieces of plywood in that section and leave the screws exposed garage side
@theuppercut
@theuppercut Год назад
From a professional plumber.. never call a turdlet a toilet!! 🚽 💩
@DillonMW
@DillonMW Год назад
My house only has one vent coming off the main drain and going up, not from each application and tying in. I guess more vents can’t hurt though.
@say_goodnight7342
@say_goodnight7342 Год назад
Any code in the u.s will want you to induvidually vent every fixture. There are some examples in the International code book and I'm sure in the uniform code book that you can wet vent a single lav sink off a water closet vent, or quick-vent an old existing island sink, but generally every fixture needs to have it's own vent, correctly sizesd as they connect to other vents through the house. My state, KY actually has it's own code, and we don't have any limitations... Everything has to be vented, no wet vents or common vents or different fixtures, no running vent's flat below 6 inches above the flood level vent, and no crown or quick vents.
@SawMan247
@SawMan247 Год назад
Looks good, not over complicated. Are you going to run pex, copper, cast pipe?
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Pex for ease. Kinda makes me wonder what with all we are learning about plastics how healthy it is to drink from
@SawMan247
@SawMan247 Год назад
@@MeltinMetalAnthony Micro plastic, can get rid of them no matter how hard you try. Much love man keep up the awesomeness. Watching you from Utah
@logangreenwald
@logangreenwald Год назад
It’s way over vented, but for what your working with i think it’s the only way without destroying all the trusses.
@mikeznel6048
@mikeznel6048 Год назад
Definitely not over vented. All the fixtures need vents.
@logangreenwald
@logangreenwald Год назад
@@mikeznel6048you can vent a whole bathroom with 1 vent. It’s over vented. But it’s the only way to do it with the way it’s plumbed in.
@bricebeaulac
@bricebeaulac Год назад
@@mikeznel6048beyond over vented
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
I guess better over than under? the reason each fixture had its own vent is I’m more than 5ft from main vent. So the way I read the code I just added more 🤷‍♂️
@bricebeaulac
@bricebeaulac Год назад
@@MeltinMetalAnthony 100%
@seanbremer6824
@seanbremer6824 Год назад
It will work
@MeltinMetalAnthony
@MeltinMetalAnthony Год назад
Thanks for the feedback!
@seanbremer6824
@seanbremer6824 Год назад
Any time brother
Далее
معركة من أجل العصيدة 👧ضد🪳
00:26
Big Baby Tape - Turbo (Majestic)
03:03
Просмотров 324 тыс.
When A Gang Leader Confronted Muhammad Ali
11:43
Просмотров 7 млн
Plumbing Code Violations (Part 1)
8:57
Просмотров 200 тыс.
My ADU Rough Plumbing (PLUS: Helpful Tips)
11:42
Plumbing Our HOME With Pex!
13:07
Просмотров 1,6 млн
FIX LEAKING COPPER PIPE - PINHOLES - Plumbing Tips
9:54
Wirtz pumps are really clever
12:05
Просмотров 13 млн
معركة من أجل العصيدة 👧ضد🪳