Тёмный
No video :(

How to AUTOMATE WATER MOTOR and NEVER worry about it again 

Syed Owais Ali
Подписаться 127 тыс.
Просмотров 93 тыс.
50% 1

Опубликовано:

 

22 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 277   
@syedowaisali
@syedowaisali 11 месяцев назад
Links to buy the products I used: Flow Sensor: bit.ly/flowsensor Float Switch: bit.ly/floatswitch15A WiFi Plug: bit.ly/smartpowerplug WiFi Plug (EU): bit.ly/smartpowerplugEU
@mwrao
@mwrao 11 месяцев назад
Magnetic contactor with float switch?
@syedowaisali
@syedowaisali 11 месяцев назад
@@mwrao comes with the switch.
@AwaisMZahid
@AwaisMZahid 11 месяцев назад
Can I get the contact details of the technician?
@usmanjaved6991
@usmanjaved6991 11 месяцев назад
How's your experience with water overflow switch. In my case the switch sometimes work and sometimes it just stuck due to friction as it's mechanical
@anmolprincess9274
@anmolprincess9274 11 месяцев назад
@@usmanjaved6991 it is happen such kind of switches usually sale low quality switches in market there have other kind of flout swiches working perfect and also for long time if available near u
@epicflicks7657
@epicflicks7657 11 месяцев назад
He's the most relevant RU-vidr for Pakistanis. Always focuses on discussing local problem and gives the best solution.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you for the kind words
@mrsajoharj121
@mrsajoharj121 11 месяцев назад
True MashaAllah 🎉
@shujarehman1322
@shujarehman1322 10 месяцев назад
​@@syedowaisalisir please make a video regarding electric gayser which consume low electricity
@tariqmuneerkhan2097
@tariqmuneerkhan2097 11 месяцев назад
I am a technical person and made a similar water controller for a suction pump using a microcontroller Arduino. No moving parts are used like a mechanical float switch etc. Just used 2 stainless steel wires to sense when the water tank is full or when the motor is dry running etc. The total cost of my product is under PKR 2000.
@adv.usamamayo9779
@adv.usamamayo9779 11 месяцев назад
Share detail for order
@hussainshabbir946
@hussainshabbir946 11 месяцев назад
Pls share details for buying
@MeharTariq
@MeharTariq 11 месяцев назад
Will you share your experience in a video player. Thank you
@mhtv3776
@mhtv3776 11 месяцев назад
Earthing in water
@noms5250
@noms5250 11 месяцев назад
I need this microcontroller based
@mohammadali3584
@mohammadali3584 11 месяцев назад
I have also developed a similar arrangement. So instead of passing 220 volts all the way up to the float switch, I'm using 12 volts and a relay.. So that it will be much safer especially during rain and bad cable insulation just in case.
@sarimbinwaseem
@sarimbinwaseem 11 месяцев назад
Before this video, I thought of the same thing...
@liyode
@liyode 11 месяцев назад
any other solution without passing wire all the way up
@shahidbhango0770
@shahidbhango0770 11 месяцев назад
یہ اٹومیٹک سوچ تقریبا ہم سات اٹھ سال سے یوز کر رہے ہیں یہ بہت کار امد ہے
@azeemshahzad4732
@azeemshahzad4732 11 месяцев назад
Thankx bhai such a wonderful idea which I was surcharging from last 4 months k what to do with overflow & extra usages of motor
@ezeeusb
@ezeeusb 11 месяцев назад
Shah Sahib you should use this system to control a relay (contactor) that will prolong your motor life and less electric usage or at least float should operate a relay . (it is technical stuff don't want to bored you with details in simple loger the distance electric travels more loss it will have) none the less this is great video with good concept.
@qamarabbasi8889
@qamarabbasi8889 11 месяцев назад
Zabar dast sir mostly plumbers & electricians Pakistan main Allah Hafiz he hai اُن سے کہیں میں نے یہ سسٹم لگوانا ہے تو انکو سمجھانا مشکل ہوتا ہے ۔😂😂
@syedowaisali
@syedowaisali 11 месяцев назад
Sahi baat hay, acha karigar dhoondna mushkil hay Pakistan mein
@MM-xp8vs
@MM-xp8vs 4 месяца назад
Perfect setup, just what I was looking for. Thank you for posting this video. ❤ from 🇮🇳
@BlueSky-cy5nw
@BlueSky-cy5nw 11 месяцев назад
Nice setup. But I don't think you are allowed to put a motor on the main water supply line. You need to have an underground tank and motor needs to be connected to underground tank. You should check with the water supply company in your area just to make sure.
@AamirSharifphotos
@AamirSharifphotos 11 месяцев назад
Great job, I am also always interested in automation, already installed the same float & wifi switch in series & Fred the time scheduled. Also try to search the water sensor for so long but could not find it. I also bought Switch Automatic Booster Regulator Water Shortage Protection Level Controller, but it could not used to sense the water but use as a booster near water tank. Now I am so happy to find such sensor. I am a great fan of your videos. I am an Economist but have a great interest in electronics and gardening Your passion of utilisation of free resources and automation are of great interest. Thanks for all your useful videos. Regards Aamir from Faisalabad
@syedowaisali
@syedowaisali 11 месяцев назад
So happy to know my videos helped you out!!
@soofihasan
@soofihasan 11 месяцев назад
This is an outstanding solution, exactly what i was looking for. Thank you so very much, may Allah bless you, my sincere prayers for you. I am a non resident and these solutions are very useful and something that i could not figure out sitting outside of pakistan
@syedowaisali
@syedowaisali 11 месяцев назад
Glad this video helped you ❤️
@Amjad-tc7tb
@Amjad-tc7tb 11 месяцев назад
Very good video. Well edited, planned contents, rehearsed, scripted, and very focused. May Allah give you success in spreading ease for the public. Love you❤❤❤❤
@rafaeengineering
@rafaeengineering 11 месяцев назад
My solution: I have placed a bigger tank back side of my home with a float valve connected to the society water supply line. The advantage is this tank remains always full with the simplest automation. No contaminated water comes into my house because water always comes when there is pressure in the line. Motor fills the top tank controlled by a level switch as he explained.
@nibainspiration8074
@nibainspiration8074 9 месяцев назад
I am residing in a township of well reputed company which more like residing abroad with a good quality life now planning to resign and move to city and afraid of challenges I've to face with lack of investment also 😢. Your many videos helpful for me . Great info bro .
@tariqanwarnoor
@tariqanwarnoor 11 месяцев назад
Really appreciate your videos. Keep up the good work. Kindly guide how to manage working of Electric Water Geyser. It should switch on automatically around 4 in the morning and switches off at given time. I want to avoid this manual hassle everyday. Thanks
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you, you can purchase this plug, this will solve all your problems: bit.ly/smartpowerplug
@mkhalil92
@mkhalil92 6 месяцев назад
Great video. It will be a big help for non techies if you could recommend someone in Lahore who may install this system
@muhammadhannanali8908
@muhammadhannanali8908 11 месяцев назад
Great Owais bhai, you're doing everything that I want to do in my house bss paise ane ka intezar ha
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you ❤️
@yzaholdings
@yzaholdings 11 месяцев назад
Great video, but I don't understand why you would want to restrict water pump based on water supply - sometimes water supply is every 2 or 3 days and the tank on the roof could run out before that. We have something similar but simpler setup at our house: 1) one float on roof water tank to detect when water goes below a certain level to turn on water machine 2) another float in ground water tank that disables power of the water goes below a certain level 3) smart switch that provides power to both floats and motor that is timed to turn off circuit during peak hours
@SheikhAzmat-i2g
@SheikhAzmat-i2g 11 месяцев назад
Please show the wiring diagram also, block diagram gives general idea what's happening around.What should be used to monitor the continuous level measurement?. This job is an intermittent level measurement, instruments should never be exposed to direct sunlight, extra shade or cover is needed.Thanks for the nice upload.
@RazaSyed12345
@RazaSyed12345 11 месяцев назад
You have no idea how long I been waiting for this video, keep up the great content ❤
@TechNerdXP
@TechNerdXP 11 месяцев назад
Bhai, bijli ki wire ko pani ke pass le ke jane se dar lagta ha, except for the very moter that pumps the water. any benign solution pls, Thanks!
@badar4550
@badar4550 11 месяцев назад
Well done in exploring this issue and finding a brilliant way to automate it. Can you please inform us how the new taxes and unit rates has effected your bills. Thanks
@HaramNaveed.official05
@HaramNaveed.official05 11 месяцев назад
If you wanna earn 50/60 k from home using your smart phone... Fill this form:👇🏼 bitly.ws/Vmrz
@AdeelSarwar2783
@AdeelSarwar2783 11 месяцев назад
Great 👍 as always owais bhai
@syedowaisali
@syedowaisali 11 месяцев назад
thank you sir
@True_Muslim_Momin
@True_Muslim_Momin 11 месяцев назад
Comprehensive Video, Very Good Presentation. Humare to Float Switch har saal kharab ho jata hai aur ye ata bhi ab itna mehnga ha.
@syedowaisali
@syedowaisali 11 месяцев назад
Yeh wala try karain, it’s good quality and can take up to 15A load
@surendardatwani7425
@surendardatwani7425 11 месяцев назад
Dear Owais I used to see ur Vidoes, always found informative. I want to upgrade ur knowledge! Never install the elbow of 90' in the outlet pipe from pump to overhead tank. All fitting must be installed with 45' of elbows. U can make experiment by using an amp meter and see the amperes consumed by pump with 90' and 45' and can see the difference.
@syedowaisali
@syedowaisali 11 месяцев назад
Interesting! Noted
@mk500i
@mk500i 5 месяцев назад
I automated my home motor after watching your video. Thanks alot
@syedowaisali
@syedowaisali 5 месяцев назад
Glad I could help!
@saifuddin1982
@saifuddin1982 11 месяцев назад
Good work! another milestone in home automation, consuming energy efficiently. Good that you have used fiberglass overhead tanks which I think are better in terms of maintaining quality of water, please correct me if I'm wrong.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you for the appreciation. I’m not sure, I have to look it up!
@iMABDuLLAHKHAN
@iMABDuLLAHKHAN 11 месяцев назад
Excellent work & suggestions. Great idea to save energy. You always come up with great solutions.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you
@saimasagheer3482
@saimasagheer3482 11 месяцев назад
Oh you gonna hit 1m soon InnshaAllah
@syedowaisali
@syedowaisali 11 месяцев назад
inshaAllah! with your support
@fozyk1099
@fozyk1099 11 месяцев назад
Just a suggestion, you and your wife could start Home Renovation business. Your dedication of not doing 'jugad' in any area is impressive. You must have face it yourself, honest and dedicated contractors are impossible to find. They'll never work on your house with the dedication that you desire. Almost every house in pindi/isb has seepage. As for the video, when I was living in GCC, humme pata hi nahi chalta tha kab paani aya, kab motor khuli, etc. Yaha aa ka har waqt conscious raho ke.. paani overflow na ho jaye, motor khuli tu nahi reh gayi, etc. And as for the first world countries, they don't even have water tanks... wo in sab cheezo se aage nikal gaye hai. Only we are stuck in these petty issues.
@syedowaisali
@syedowaisali 11 месяцев назад
We would love to but it requires a lot of time commitment which we can’t give at the moment.
@abdurrahmankhan1107
@abdurrahmankhan1107 11 месяцев назад
Sir advance congratulations for 100 thousand subscribers. In Sha Allah, Allah will grant you more success, Ameen
@akhaqan
@akhaqan 11 месяцев назад
Nice video, as always. Does this system retain time or resets after power failure, if so, it may never reach the 1-hr limit to check for water availability if power keeps cycling every hour. Knowing how sensitive electronics are and how quickly they fry with power failures & surges, I'd be interested in knowing how this setup fares after one year. The level switch should be fine, it's the electronic circuitry on the motor that I am concerned about.
@kilikhan1124
@kilikhan1124 11 месяцев назад
Good upload, I was looking for such system, infact had lost hope, thanks
@dashcam6484
@dashcam6484 11 месяцев назад
Wonderful brother. I've been a part of your journey since Qatar. Canada kabhi chakar lagain tou zaroor milye ga.
@syedowaisali
@syedowaisali 11 месяцев назад
InshaAllah zaroor
@basharataliful
@basharataliful 11 месяцев назад
Well done Mr. Owais. Thanks for this useful information.
@syednaveedalishah8654
@syednaveedalishah8654 3 месяца назад
Bhai over head tank ke switch se normally control wires thin wires use karne chahy na ke 329 ke wires is ke 3 reasons hen (1) cost cum ho ge.(2)5vdc ya 12vdc supply use Karen (3)4 safety Aakhir men control relay use Karen motor ko start/stop karne ke ly.
@HaiderAli-mt9oz
@HaiderAli-mt9oz 2 месяца назад
Agar hmne normal 220v wala suction pump chalana hai to can we automate it using 12v control reley ?
@malikawan19
@malikawan19 11 месяцев назад
I had been looking for this for a while. Thanks
@zaeemashraf
@zaeemashraf 11 месяцев назад
MashaALLAH another great video from Owais bhai
@zubairmushtaq7912
@zubairmushtaq7912 11 месяцев назад
i also been looking to automate my motor ,thanks for sharing
@MalikJi-om5js
@MalikJi-om5js 4 месяца назад
Masha Allah shah sab good job
@muhammadraziq8837
@muhammadraziq8837 11 месяцев назад
میں نے گھر میں ایک سسٹم بنائی ھے۔جب ٹینک پر ھو جائے تو خود کار طور سے پمپ بند ھو جاتی ھے۔بالکل کامیاب ھے جی۔سادہ ھے۔کرنٹ لگنے کا بھی خطرہ نہیں ھے کیونکہ ڈی سی سے ھی یہ سسٹم کام کرتی ھے اگر چہ پمپ اے سی ھے۔اس سسٹم میں کوئی الیکٹرانک پارٹس نہیں ھیں۔
@Zulfiqar.Ali.Abbasi
@Zulfiqar.Ali.Abbasi 11 месяцев назад
Thats great (Y). As always Quality Research and Content. Can you please kind enough to answer or research about how we use this system in case of Water Tank for water supply instead direct connection. will be very greatful
@ssssaaaa4916
@ssssaaaa4916 11 месяцев назад
Request: Akk video bana de UPS per Jo AC air conditon chal sakhta ha jaise kai Market mei ajkal aisay Ac b aay hoay han DC inverter ac on UPS.
@Grabbola
@Grabbola 11 месяцев назад
Awesome was looking for such a solution. Thanks❤
@asifalasad143
@asifalasad143 6 месяцев назад
السَّلاَمُ عَلَيْكُمْ وَرَحْمَةُ اللهِ وَبَرَكَاتُهُ ! جزاك الله خيرا !
@Farebii
@Farebii 11 месяцев назад
Nice work as always owais put ur input about net metering govt is going to reduce the rate
@Faizanjalal
@Faizanjalal 11 месяцев назад
Always next level video in Pakistan...❤
@shafqatkhan7175
@shafqatkhan7175 11 месяцев назад
salam bhai apnay pvc blue tank install keay hain jo not good for health at all but can be used for irrigation purpose, you supposed to use fiber glass tank
@syedowaisali
@syedowaisali 11 месяцев назад
Ok
@musibtay109
@musibtay109 11 месяцев назад
Very informative video. I've a question that can we use the water sensor on bore system rather than government water supply. As we live in karachi and now there is no concept of water supply by KW&SB and almost every home have boring system and rely only on it. The motor is inside water lines might called rocket pump or what, which is not visible or easily accessible. Hope you understand my query.
@syedowaisali
@syedowaisali 11 месяцев назад
Yes it will work on bore also
@musibtay109
@musibtay109 11 месяцев назад
Thanks@@syedowaisali
@abdullahshahzad9368
@abdullahshahzad9368 11 месяцев назад
Quality content as always ❤.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you 🙌
@shakeelmrmovieyoutubechann8029
@shakeelmrmovieyoutubechann8029 11 месяцев назад
Very Good Video Jazak allah bhai
@funfact9612
@funfact9612 11 месяцев назад
buht hi informative channel hai
@sikanderasif2097
@sikanderasif2097 11 месяцев назад
Hey. How to avoid direct contact of sun with watertank which causes the temperature of water to rise?
@hasssssu
@hasssssu 11 месяцев назад
Owais bhai I have been watching your videos since the beginning, and I am huge fan of your work. You seems like a person who manage things wisely. What do you suggest for people who are struggling in Pakistan? People who are not seeing their future in Pakistan.
@syedowaisali
@syedowaisali 11 месяцев назад
Move abroad if you can.
@hasssssu
@hasssssu 11 месяцев назад
@@syedowaisali Thank you for replying. I am already pursing my PhD abroad. I am asking for general public. You have experience living abroad. A video on this topic will be a huge help for people who are trying to find their way.
@yaseenkhan1435
@yaseenkhan1435 5 месяцев назад
Sorry to say what about submersible water machine in a well or 3 inch bore
@8Hills
@8Hills 11 месяцев назад
Welldone Good job, Very Informative Video. THANK YOU VERY MUCH 👍🏻🤣
@MuhammadHassan-os8ci
@MuhammadHassan-os8ci 11 месяцев назад
Excellent guidance provided
@younussafdar4725
@younussafdar4725 11 месяцев назад
quality content. kindly share your views/experience on reliable water motors as well.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you
@muhammadadnan8590
@muhammadadnan8590 11 месяцев назад
Sir electric scooty pr video banaye plz k leni chahye k nhi
@bakhtiarali1040
@bakhtiarali1040 11 месяцев назад
Phone se control karnay ka idea talaash kejey.❤
@syedowaisali
@syedowaisali 11 месяцев назад
You can control this with your phone, check the 3rd component explained
@tocf74
@tocf74 11 месяцев назад
Its a good solution and i am looking for myself for a long time. but i think it is valid when you motor is directly connected to a municipal water line?
@syedowaisali
@syedowaisali 11 месяцев назад
It works with underground water tank also
@SolvingSkills
@SolvingSkills 11 месяцев назад
Very nice project, thanks for sharing!!❤
@soulstudio451
@soulstudio451 11 месяцев назад
Suitable for water supply lines only not for bore
@gtssami8606
@gtssami8606 11 месяцев назад
Very informative video,thanks for sharing ❤
@MrHeartheacker
@MrHeartheacker 11 месяцев назад
buhat ala Shah G!! JazakAllah
@madil2259
@madil2259 11 месяцев назад
Very well done, Awais bhai.
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you
@skullduggerygillen
@skullduggerygillen 11 месяцев назад
Great video as always
@liaquatali6494
@liaquatali6494 11 месяцев назад
Amazing
@irfanbhatti8486
@irfanbhatti8486 11 месяцев назад
What about air in the supply line we face this problem every time we have released the air manually released the air from the supply line in this setup this problem will solve??? Pls advise
@TechyEra
@TechyEra 11 месяцев назад
bhai please 2023 ma AC ki recommendation krdo. Kenwood 1838s eSmart Plus ki climate Type T1 likhi hui ha ab sticker p
@inamhusain
@inamhusain 11 месяцев назад
OWAIS AAP KI AWAZ ARSHED SHAREEF SE BOHT ZIADA SIMILAR HAI. SJHAYED AAP KO PATA HAI YA NAHI.
@ranahuzaifa3303
@ranahuzaifa3303 11 месяцев назад
Great Work Mashallah 👍🏻👍🏻
@talhaanwer393
@talhaanwer393 11 месяцев назад
Adding 12V relay to float switch is good for safety, and it will extend the life of float switch forever.
@pervaizahmed8319
@pervaizahmed8319 11 месяцев назад
Sir g I am facing problems for water filling in water tank I have no any device that is going in water tank or not because after some time water is not coming from government pipe line
@kamrannazir4767
@kamrannazir4767 11 месяцев назад
Always make excellent video one question which company you bought the motor attached to auto switch o hope it's not noisy too please advise
@syedowaisali
@syedowaisali 11 месяцев назад
It’s just a regular motor, nothing fancy
@waqas6698
@waqas6698 11 месяцев назад
Hello Owais, saw your video and look got interested in the solution. I have a question. Is the water sensor always on or it just goes live when water level gets below a certain level?
@syedowaisali
@syedowaisali 11 месяцев назад
Only goes live when the water level goes below a certain level.
@salmans75
@salmans75 3 месяца назад
How s your experience been with this water sensing pump controller module? I only worked a few weeks for me and has been working as always on.. Indicating water even when dry
@syedowaisali
@syedowaisali 3 месяца назад
It is still working for me. Did you contact the company about the issue?
@salmans75
@salmans75 3 месяца назад
@@syedowaisali i would contact the supplier now
@noumanmoeen5980
@noumanmoeen5980 11 месяцев назад
Great content as always. BTW Can you make a video to update us on your solar system and how it's going ? Actually I am thinking of installing a solar system at my home but I've heard that government are making ammendments in their policies and ending net metering.
@adealmb3049
@adealmb3049 11 месяцев назад
Just quickly buy a hybrid inverter system don't wait. Prices have started going up again
@navahmed1
@navahmed1 11 месяцев назад
Excellent solution
@syedowaisali
@syedowaisali 11 месяцев назад
Thank you
@malikmansoor2624
@malikmansoor2624 11 месяцев назад
Owais bhai thanks for the informative video really helpful
@syedowaisali
@syedowaisali 11 месяцев назад
You’re welcome
@fouadmurtaza3133
@fouadmurtaza3133 5 месяцев назад
Why not just have a sensor in underground tank so it only turns on when there is water in it
@shehbazishaq8352
@shehbazishaq8352 11 месяцев назад
Very useful and informative vlog..
@huzaifaali837
@huzaifaali837 11 месяцев назад
what if the ground tank and roof tank, both are filled with water?
@ghs407gb9
@ghs407gb9 11 месяцев назад
AoA Shah Sb. I build a new home from where electricity pole is far away. Low Voltage is my big problem. I'm going for electricity wiring in my home tomorrow. I wanted to shift my electricity load on 3 kv solar system in next couple of months. Kindly suggest me important tips @ this stage, so I may able to overcome all the difficulties about wiring while shifting on solar. Net metering facility not available in this area. Waiting for your kind response..Shukriya
@purelife340
@purelife340 11 месяцев назад
Great job bro
@anjaliparmar6174
@anjaliparmar6174 3 дня назад
My area government water supply is not at a regular time. Sometimes morning sometimes evening. Our water pump system is manual. Can this be fixed on our system. My need is whenever water supply comes pump should start automatically and stop when when water is gone. Bcos we get water only 1 hr per day. Any suggestions
@syedowaisali
@syedowaisali 3 дня назад
@@anjaliparmar6174 yes it should fix it. It will check every 1 hour. The only downside is if pump controller checks water at 12pm and water comes at 12:10, the motor will not know until 1pm. That’s the only issue otherwise it will work.
@MrSalmangorsi
@MrSalmangorsi 11 месяцев назад
How is the living experience in bani gala?scenic, peace,security and facitlies
@abidsamdani1767
@abidsamdani1767 11 месяцев назад
how this device is connected to underground water tank or water supply line ?
@farhan7690
@farhan7690 11 месяцев назад
As always the best thank you
@qazimuhammadali3457
@qazimuhammadali3457 11 месяцев назад
Donkey pump ( reciprocating pump ) میں dc موٹر استعمال کی جا سکتی ہے یا نہیں؟ گھر کے لئے dc موٹر کامیاب ہے یا نہیں؟
@BlackGold2012
@BlackGold2012 11 месяцев назад
Good job
@AslamKhan-rk5rk
@AslamKhan-rk5rk 11 месяцев назад
ہم 20 سال سے ایران میں یہ سسٹم لگا رہے ہیں جب پانی آتا ہے تو موٹر سٹارٹ ہو جاتی ہے اور ٹینک فل ہونیکے بعد موٹر بند ہو جاتی ہے
@razasohail5020
@razasohail5020 11 месяцев назад
my issue is that I want my motor pump switch to get off after exact 15 minutes each day? can you please make a video on this? what to do if I dont want to use any microcontroller?
@syedowaisali
@syedowaisali 11 месяцев назад
Use a WiFi plug I’ve linked
@usmantariq361
@usmantariq361 11 месяцев назад
Improvisation personified.
@tsxtreme
@tsxtreme 11 месяцев назад
How can the flow sensor, which is connected at the outlet of the pump, sense the availability of the the water from the water supply?
@sarimbinwaseem
@sarimbinwaseem 11 месяцев назад
After motor runs for 1 minute, it waits for water to run through the sensor. if water does not come, motor is shut of...
@abduldina
@abduldina 5 месяцев назад
اسلام علیکم بھائی میرے بور سے بہت زیادہ ریت اتی ہے کوئی ایسا فلٹر ہو جو میں مین موٹر پے لگا سکوں ؟؟
@AbdulRauf-pk5ks
@AbdulRauf-pk5ks 11 месяцев назад
Thanks for sharing.
@azhariqbal1390
@azhariqbal1390 11 месяцев назад
This system is installed on the water supply line. What about the system where water comes in the underground tank and motor sucks water from the underground tank and sends it to the overhead tank?
@syedowaisali
@syedowaisali 11 месяцев назад
Same system can be installed in this scenario too. No modifications needed.
@rizwanshaikh3630
@rizwanshaikh3630 11 месяцев назад
Great Idea
Далее
N-Type vs P-Type Bifacial Solar Panels
17:48
Просмотров 174 тыс.
МЕГА МЕЛКОВЫЙ СЕКРЕТ
00:46
Просмотров 199 тыс.
How Inverter Fans Reduce Your Bill
20:38
Просмотров 277 тыс.
Pressor Pump: Crucial Float Switch Tips
9:22
Water Tap Spindle Repair at home
13:50
Просмотров 523 тыс.
Auto Refilling System For water Tank
8:08
Просмотров 95 тыс.
How to Buy AC in Pakistan
29:17
Просмотров 695 тыс.
Things to know BEFORE going SOLAR in Pakistan
8:47
Просмотров 130 тыс.