Тёмный

How to build and install a gas sediment trap for water heaters and other appliances 2023 edition 

Plumbing Explained
Подписаться 87 тыс.
Просмотров 4,7 тыс.
50% 1

#plumbing #plumber #service #serviceplumber #sedimenttrap #gasflex #california #socal #orangecounty
#water #waterheater #bradfordwhite #gas #dirttrap #appliances #bluecollar #ridgidtools #milwaukeetools #pipewrench #knipextools #knipex #prodope #hercules #siouxchief
www.OCunclogged.com
for service in Orange County

Опубликовано:

 

17 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@tacklebox6239
@tacklebox6239 Год назад
Pro dope for gas lines 👍🏻
@billthomas6296
@billthomas6296 Год назад
I agree about no tape and using just pipe dope on the gas control. Good call. I have seen them crack as well over the years.
@charlescoates5761
@charlescoates5761 Год назад
👍👏🙂
@Heather_hutt_panties_facemask
The code here is sediment trap after valve before the flex. It is a dumb way to do it but its the current code in so ca
@PlumbingExplained
@PlumbingExplained Год назад
Gotta justify the jobs and further education of the inspectors
@plumber1874
@plumber1874 Год назад
The only thing Ive ever found in a sediment trap is thread cutting oil from the the guy who put the pipe to begin with
@marks4471
@marks4471 Год назад
Exactly. If the gas lines had so much sediment, they'd require the sediment traps on the gas dryers and ranges too!
@PIMPSTA951
@PIMPSTA951 7 месяцев назад
The yellow gas line should come out the wall pointing down to a T striaght to the sediment trap right before it connects to the water heater. In other words it needs to be on the opposite side. !-[]
@ricklee827
@ricklee827 Год назад
Once you tighten up gas pipe you should not go backwards make another full turn
@mackellyman5642
@mackellyman5642 8 месяцев назад
Please turn the valve around so we don't have to flex the wrist...
@jeffreyplumber1975
@jeffreyplumber1975 Год назад
I looked at 2022 cpc 1212.9 and effective date is jan 1 2023 . Sediment trap needs to be downstream of shut off valve and as close as practicle to the appliance. Im not following any mention of being upsream of the flex connector in the code? I think 2016 and 19 code requires the flex line upstream of trap and that should be winding down whenever jobs start requiring the 2022 code
@PlumbingExplained
@PlumbingExplained Год назад
It might just be a California thing, here’s a diagram www.riversideca.gov/cedd/sites/riversideca.gov.cedd/files/pdf/building/forms/Inspections_page_handouts/2019%20CPC%20Gas%20Applaince%20Sediment%20Traps.pdf
@mackellyman5642
@mackellyman5642 8 месяцев назад
I think it's all about shutting off the gas and being able to remove the cap to clean the trap?
@Zeric1
@Zeric1 6 месяцев назад
@@PlumbingExplained according to the document linked for Riverside CA, both the text and the diagrams show the valve should be upstream of the sediment trap. This is NOT what the video shows. Is it a big issue, probably not, but it what the video shows is not exactly up to code.
@donaldblank8873
@donaldblank8873 Год назад
If you did not have access to the gas meter you should definitely not be working on the gas piping, END OF STORY.
@PlumbingExplained
@PlumbingExplained Год назад
😂
@RH-cv1rg
@RH-cv1rg Год назад
If you are going to narrate, turn off the music.
@PlumbingExplained
@PlumbingExplained Год назад
I’ll keep the music lower if I do use it again.
@mushroomcaps
@mushroomcaps 6 месяцев назад
The music is too loud and really bad over this video. I can't even focus on what you're saying despite the fact that this is most likely the information that I really need, I just can't bring myself to finish the video. 🙉
@joeblair77
@joeblair77 Год назад
Fuel gas code says you can’t use a stove connector on a water heater🤔
@PlumbingExplained
@PlumbingExplained Год назад
Code in California is different because it’s a seismic area with earthquakes, local code supersedes the book
@joeblair77
@joeblair77 Год назад
Yeah I know, just messin with ya🤘🏻
@billthomas6296
@billthomas6296 Год назад
@@joeblair77 we use them in Tennessee as well
Далее
How would you react?!😳
00:44
Просмотров 4,1 млн
Installation of a Gas Water Heater
21:20
Просмотров 28 тыс.
Water Heater Gas Pipe Assembly
7:15
Просмотров 115 тыс.
Gas furnace piping, sediment trap, dirt leg, drip leg,
23:00
How To Install A Gas Water Heater
4:36
Просмотров 136 тыс.
How to Install Water Heater Sediment Trap EASY!
2:37
FLUSHING A Water Heater The RIGHT WAY Step by Step
10:04
How would you react?!😳
00:44