Learn how to compare steel beam vs wood beams using easy calculations.
✅Get the timber tables used in the video: geni.us/timber...
Find out if it is possible to replace steel beams with timber beams, along with calculations on how you can compare the two. In this video we take the example of a loft conversion steel beam, and work out how big a timber beam would need to be to replace it.
💰Support this channel here / robindejongh
🥈Get the steel beam reference tables used in this video: geni.us/steelt...

Опубликовано:

 

4 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 86   
@RobindeJongh
@RobindeJongh 2 года назад
🚀Get the timber tables used in the video: geni.us/timbercalculation
@Musicalbluewolf666
@Musicalbluewolf666 2 года назад
hi robin, could you use a flitch beam instead of a steel . my floor spans around 6 meters and can you use it as a sister as you can only buy 4.8 m timber thanks.
@eliinthewolverinestate6729
@eliinthewolverinestate6729 10 месяцев назад
250 mm x 100 mm is only a 4x10. Which 2 2x12 boards glulam together exceeds whats needed. Which is around 50$ per 16 foot board here. And a quarter of the weight of steel. A timber frame don't need fire suppression here. A steel beam collapses under it's only weight in 15 minutes at 1400*F. The wood beams take over and hour. A steel beam here is around 100$ per foot. Meaning 2 steel beams is more than I spent on all the wood for 24x24 foot skillion cottage rising up 24 feet including roofing.
@mohamedkhan4762
@mohamedkhan4762 6 месяцев назад
Please make more of these videos super helpful 🙏🙏
@DanielPaprocki
@DanielPaprocki 2 года назад
Then you for clarification. Now I understand better the difference between steel and the timber 😊👍🏻
@stevenstart8728
@stevenstart8728 2 года назад
Why not use the proposed stud wall above the beam as a fabricated truss to span the 5 metres?
@villegas5874
@villegas5874 Год назад
Wow. Nice practice.
@mick4820
@mick4820 Год назад
Very informative,, thank you
@theb.1723
@theb.1723 2 года назад
hence the use of Glulam/LVL/Parallam etc.. :)
@MJWhelan1
@MJWhelan1 2 года назад
Cheers Robin, very informative as always! Could you do a video on when you choose a UB over a lintel? I'm used to seeing brickies using PCC, steel box and steel cavity lintels where I'd have thought a UB would have been required due to spans
@RobindeJongh
@RobindeJongh 2 года назад
That's a very good idea!
@MJWhelan1
@MJWhelan1 2 года назад
@@RobindeJongh Cheers at very least it would be interesting! I've seen what must have been a 4m cavity lintel installed before and that can't have been leaving much of a safety factor!
@RobindeJongh
@RobindeJongh 2 года назад
@@MJWhelan1 The lintel suppliers have a trick up their sleeve, which is that they increase the lintel depth and steel thickness the bigger the span, even though they call it the same lintel name.
@MJWhelan1
@MJWhelan1 2 года назад
@@RobindeJongh Completely appreciate that the depth and thickness have to change to accommodate the increase in length and load like all beams, guess I am just interested in if there is a point in the calcs/decision making process that a lintel is determined as more appropriate than a UB?
@markfinnegan6038
@markfinnegan6038 2 года назад
Is there a table somewhere than can help with determining what size steel beam(s) would be needed to replace a 16height x 3.5 inch width (a doubled 1.75) x 25ft long LVL beam? I am even open to having an additional steel support if necessary.
@smith7108
@smith7108 2 месяца назад
Would like to see the calcs using hardwood, tried to find tables to work it out but didnt have much luck not sure where to start looking
@frank1847
@frank1847 10 месяцев назад
A very interesting video. Have you ever used a flitch beam in this sort of scenario?
@pauldiamond1481
@pauldiamond1481 28 дней назад
Flitch beams are mostly obsolete after the advent of engineered lumber (LVL, LSL, PSL)
@richardfweeler2939
@richardfweeler2939 6 месяцев назад
What about if you used the timber in a timber frame structure (similar to ladder horizontal ) then screwed and glued both sides , so you get the depth . This could be constructed on site and would be far easier to handle that a large steel girder ? ?
@refraction9605
@refraction9605 2 года назад
Very informative thank you…. Have liked and subscribed 👍
@joekavanagh5708
@joekavanagh5708 2 года назад
The timber beam section modulus of 4168 can be achieved using only TWO 250 x 100 beams, stacked vertically. The extra height of the stacked beam is not a problem in this attic. However attaching the joist at 90 might be less convenient than onto the steel beam.
@a0flj0
@a0flj0 2 года назад
I believe you can achieve even better stiffness and load bearing capability with a more elaborate truss design, using an even lower volume of wood. Granted, it's much more work to build a wooden truss than to just slap a steel beam in place. Then again, a steel beam on an exterior wall always significantly reduces thermal insulation properties (i.e. enough to feel it in your wallet), compared to something using wood, unless you build up the insulation.
@joekavanagh5708
@joekavanagh5708 2 года назад
....just making the point that two beams stacked on their narrow sides improve the section modulus by 4 times. i.e. the square of the height/depth increase.
@RobindeJongh
@RobindeJongh 2 года назад
Hi Joe - correct, increasing the vertical height is most economical, though the beam would need to be very well restrained to stop it buckling.
@davejohnston5158
@davejohnston5158 10 месяцев назад
I think one of the main limitations of timber is the deflection that occurs under live loading within permissible stress, sometimes to an extent that results in cracked plaster etc.
@javierpetiso
@javierpetiso 2 дня назад
Hello Sr. I'm planning to build a patio cover that measures 7meters by 3.5 meters I would like to use an I beam 7meters go to put wood beams on it .would you please tell me what kind of measures I need on the I beam for this proyect.? I may put 2 500 lbs. Thank you.
@peterpauldonoghue7024
@peterpauldonoghue7024 2 года назад
Thank you Robin Can you do a video soon on Units I have always struggled with conversions like cm^4 to mm^2 And how to cross off units above and below the line ( if you know what I mean) Thank you for sharing your knowledge and for the tables . Kind Regards, Peter
@RobindeJongh
@RobindeJongh 2 года назад
Hi Peter. Great suggestion! Units are probably the biggest thing engineers get tripped up on when doing hand calculations.
@liftfan2
@liftfan2 Год назад
Interesting thanks. I see a lot of discussion on whether to use timber or steel needles when propping walls above for steels to go underneath. Maybe use could compare the strength of those?
@noahnorberg575
@noahnorberg575 2 года назад
Thank you for his beneficial video =)
@RobindeJongh
@RobindeJongh 2 года назад
Thanks Noah 👍
@mikefiatx19
@mikefiatx19 Год назад
Great video. thanks. Could you compare steel and concrete precast beams?
@lancemillward1912
@lancemillward1912 Год назад
How about with the steel sandwiched between timber.
@bernardwarr4187
@bernardwarr4187 Год назад
One would think that would be a good way of increasing strength, steel plate laminated with bolts between 2 timbers
@mckenziekeith7434
@mckenziekeith7434 Год назад
You want the higher tensile material farther away from the neutral axis. So two steel plates with wood in between could maybe be viable. The wood would act like the flange (or web) in an I beam. The wood would be under shear stress and the steel would be under compression on top and tension on the bottom. The wood and steel would have to be bonded together well somehow. It is no good otherwise.
@ianwinwood9400
@ianwinwood9400 2 года назад
How does bolting smaller steel beams together to make a larger beam affect the beam choice. Any guidance on doing this to achieve suitable loadings. Also what would the loadings per M2 be if it was just a floor so no roof supporting was required.
@kntran10
@kntran10 Год назад
Can you make a video on how to calculate the header needed for a 6 feet opening on a 4 story, very rectangular flat roof home ? lol where the ceilings are 8 feet high haha. 😜
@duanethieme4186
@duanethieme4186 Год назад
For a residential second floor joists how much can I span 2"x6" (with 1/8" web thickness) mild steel I beams at a 30 sq ft live load and also 40 sq ft live load? Thank you.
@ToroMoto
@ToroMoto 2 года назад
Why do you not factor the UDL on the timber beam calculation like you did with the steel? By the way, fantastic video, thank you for showing all the steps. Very helpful!
@RobindeJongh
@RobindeJongh 2 года назад
Thanks - glad you liked it! Steel design to BS5950 is "limit state" philosophy, so you factor the loads. Timber design to BS5268 is "allowable stress" philosophy, which means the allowable stress for the material already has a factor of safety in it. Confused yet?!
@ToroMoto
@ToroMoto 2 года назад
@@RobindeJongh That is clear thank you. I am used to CSA codes and no not do much timber design (not since school anyways). Thanks for clarifying!
@Mghanabro
@Mghanabro Год назад
Cheers Robin for a 5m span what size of c24 timber
@AbuOmar1970h
@AbuOmar1970h 2 года назад
i would like build a room with steel but i do not know what size should i used and what space between columns . my space is 4X6 M and there Wall from 3 side . no wind there .
@johnoconnor3005
@johnoconnor3005 Месяц назад
What about a flitch beam?
@olgajoachimosmundsen4647
@olgajoachimosmundsen4647 2 года назад
Robin; can you explain the difference between steel and wood beams when it comes to nothcing, drilling holes etc? Does holes and cut-outs affect wood and steel beams in the same way, or are there differences? If you have a steel beam and wood beam that can carry equal loads; will the same hole drilled in the beams weaken them equally? Does screw-holes weaken a beam?
@RobindeJongh
@RobindeJongh 2 года назад
The steel beam is more accommodating to holes, since most of the material is in the top and bottom flange. With timber you are in danger of weakening the whole beam, as the whole of the section is used to resist bending and shear.
@scootertheeb6172
@scootertheeb6172 2 года назад
Your calculation is based on strength equivalency, however, we also need to assess the stiffness equivalence.
@RobindeJongh
@RobindeJongh 2 года назад
Hi Scott. Correct, stiffness (i.e. deflection) also needs to be calculated, and that would be the next step as I mentioned in the video.
@scootertheeb6172
@scootertheeb6172 2 года назад
@@RobindeJongh I’m looking forward to your next video.
@user-vr8zh2cv9y
@user-vr8zh2cv9y Год назад
Hello I looking to support 700kg 320cm long Wich beam should I use I dont have idea . Thank You for help
@artomczak
@artomczak 2 года назад
Thanks Robin. Why did you use 7.5 N/mm2 as the value for C24 timber? In Eurocode tables I see it is 24 N/mm2 for bending.
@RobindeJongh
@RobindeJongh 2 года назад
Using British Standards, we use allowable stress, which hsa factors of safety built in. Eurocode has changed this to limit state design, which uses a figure of ultimate stress.
@anthonybrown7959
@anthonybrown7959 Год назад
Would adding steel between the wooden beams, turning it into a flitch beam bring it up the same spec as the eye (I) beam.
@RobindeJongh
@RobindeJongh Год назад
Hi Anthony. Not quite, but it would be a big increase in strength and stiffness.
@MrTimjin
@MrTimjin 2 месяца назад
How did you picked C24 grade timber with 7.5n/mm2 over others? Thanks.
@RobindeJongh
@RobindeJongh 2 месяца назад
C24 and C16 are the commonly available grades in the UK. C24 is stronger, so I went with that.
@douglasprovost768
@douglasprovost768 2 года назад
Flitch ?
@RobindeJongh
@RobindeJongh 2 года назад
Good call, Douglas.
@andynewey7564
@andynewey7564 2 года назад
@@RobindeJongh Definitely needed for me. I am looking into a flitch solution instead of steel beams for a loft conversion.
@ArabVlog
@ArabVlog 2 месяца назад
Why not engineered timber and why not taller and thinner timber, i know it would take more space but when you have that in mind and design a building with it in mind then its different
@RobindeJongh
@RobindeJongh 2 месяца назад
Very good points. In the UK engineered timber is not always widely available, but it is getting better.
@عسا-غ2ح
@عسا-غ2ح 2 месяца назад
thank s another HOW MUCHE DEFIANCE white between 5 meter I steel temperature to equate 5 meter wood temper ? Friend from Baghdad. 27 inlay 2024
@ratscabies8458
@ratscabies8458 8 месяцев назад
Hi John. Just a thought, I need a ridge beam for a project. I have many 200 x 50 timbers that were spare from another job. Instead of using 2 side by side and bolted could I use them on top of each other to make a 400 x 50 ? I would aim to mechanical fix and glue together but more importantly to clad both sides with 12mm plywood glued and screwed to prevent each timber moving independently. Not allowing for any strength the plywood gives where would this timber, 400 x 50 sit in your timber calculation table as they only go up to 250mm ? Thanks
@romeo2473
@romeo2473 6 месяцев назад
Your beam would definitely be subject to bukling. But the real question is, what is your span and expected load?
@Midnight-tornado86
@Midnight-tornado86 2 года назад
Hi very interesting video I’m currently discussing steel with my structural engineer as I believe he’s over calculating he wants 203x203 UC 71 grade 43 both at 6500mm to run under the purlins but it’s impossible to get them in a loft as the size and weight makes this very difficult
@RobindeJongh
@RobindeJongh 2 года назад
Hi. I suggest asking your structural engineer if he would mind considering the beams to be "fully restrained" by connecting them to the floor joists.
@Midnight-tornado86
@Midnight-tornado86 2 года назад
@@RobindeJongh Thank you the way he has the steals it’s just not possible to be installed I don’t know anyone else to ask had a look on RU-vid and came across your page I don’t know any structural engineers who I could ring which would make life a lot easier
@RobindeJongh
@RobindeJongh 2 года назад
@@Midnight-tornado86 Hi. As I said, if you ask your structural engineer to design the steels "fully restrained" then they should become far smaller, cheaper, and lighter.
@ESPPsycho
@ESPPsycho 2 года назад
Hmm.. where did 275 come from?
@atlanticengineeringgroup4113
I wish he reply!
@judegraham463
@judegraham463 2 года назад
Hi Robin. ending up with the equivalent of 4 250 x 100 timber beams, makes me wonder if actually the U Beam is way over spec. What are your thoughts on some structural requirements in residential building. I know this is a very vague, and broad question to be putting to you. but sometimes I get the feeling, 'is this size beam really needed'. I guess engineers are left having to calculate structural dimensions for the least common denominator. Thanks Robin.
@RobindeJongh
@RobindeJongh 2 года назад
Hi Jude. There is always the possibility in every industry that you get an inexperienced engineer who covers themselves by over engineering a beam. However this is rare. Bear in mind that beams need to be designed to stringent deflection limits, so even if a beam is more than strong enough to bear the load, it may still fail deflection criteria.
@judegraham463
@judegraham463 2 года назад
@@RobindeJongh Hi Robin. Excuse me, I missed your response. Thanks so much for making the effort to explain how there is more going on than I may imagine, which obviously, I greatly appreciate. I'm going to be demonstrating more ignorance here, but how much is 10kn/m. The reason I ask is that I am looking at installing a 4.8m beam myself, across an opening that will have the post from a gable roof ridge beam sitting right in the middle of it, that itself will be supporting a sheet metal roof, less than 40kg/m2, with a RLW of 3.2m. It scares me to think I'd be needing a timber beam anywhere near the size mentioned here. Though like you say, as steel is so much stronger (37 x stronger) than timber, they dont need to be anywhere the size of timber. So a UB would probably be the only way to go. It's a juggling act between size and proportion and aesthetics, and money. Thanks Robin. Gives me a lot to think about. P.S. I tried making one of your calculations on my computer keyboard the other day but I couldn't for the life of me figure out how to work the 'log' sign on the keyboard. thanks again Robin.
@shanetalbot8402
@shanetalbot8402 2 года назад
So how would you compare your steel beam to a glulam beam instead?
@RobindeJongh
@RobindeJongh 2 года назад
Hi Shane. Thanks for the suggestion - I'll add this to the list.
@malcolm_in_the_middle
@malcolm_in_the_middle 2 года назад
How does this compare with engineered timber, e.g glue laminated timber?
@RobindeJongh
@RobindeJongh 2 года назад
Hi Chris. Glulam is stronger than ordinary timber and also you can get a much deeper beam section size.
@Darnic-Fab
@Darnic-Fab Год назад
Hi Robin I have a 3 ply LVL 24' long x 5-1/4" thick x 18" deep specced for a job. Is there a easy way to convert this to steel? I have all the Member Information and Analysis Results for the wood beam. I have checked with my steel supplier and they don't do this, and I am not sure if I could find a Engineer to take time out to do this. If you could point me in the right direction that would be very helpful.
@RobindeJongh
@RobindeJongh Год назад
Hi. Any structural engineer would be able to carry out this calculation for you. Or contact us here forms.gle/ooxdhbUT6ku4jBkP9 Or you can take a look at this course if you would like to learn how to spec a steel beam yourself: geni.us/beamcalculations
@Darnic-Fab
@Darnic-Fab Год назад
@@RobindeJongh Thank you
@morosmith8710
@morosmith8710 Год назад
Hi Robin, 1.5 F.O.S is for live load is it not?
@RobindeJongh
@RobindeJongh Год назад
Hi. With British Standards steel design, the FOS for dead loads is 1.4 and live loads 1.6, so you can use a combined factor of 1.5 to simplify things.
@morosmith8710
@morosmith8710 11 месяцев назад
@@RobindeJongh thank you
@lacihalasz
@lacihalasz 2 года назад
I need a beam for 3 meter span . So i would like to put a beam 15 cm x 25 cm ( 3 beams glued together , 5 cm x 25 cm ) . Is that going to be ok ? Upstairs is a concret and block floor. Tnx
@RobindeJongh
@RobindeJongh 2 года назад
Hi Lacy. You wouldn't want to support a concrete floor on a timber beam, in my view. Best to get a beam designed by a structural engineer.
@Tadrjbs
@Tadrjbs 2 года назад
Absolutely useless in fig newtons...
Далее
This mother's baby is too unreliable.
00:13
Просмотров 9 млн
HA-HA-HA-HA 👫 #countryhumans
00:15
Просмотров 4 млн
Китайка стучится Домой😂😆
00:18
How to do a steel beam calculation
11:32
Просмотров 152 тыс.
Loft conversion without steel beams
12:32
Просмотров 169 тыс.
How much load can a timber post actually carry?
8:57
Просмотров 776 тыс.
TRADITIONAL LOFT METHODS TO CONVERT LOFT SPACE
16:10
Просмотров 69 тыс.
The Secret Behind the "I-Beam" Strength
6:07
Просмотров 631 тыс.
Surprising facts about Glulam Engineered Beams
21:09
Просмотров 90 тыс.
HOW TO INSTALL A STEEL BEAM IN DETAIL
18:22
Просмотров 149 тыс.
Science of Simple Spans of Floor Joists
11:30
Просмотров 954 тыс.
This mother's baby is too unreliable.
00:13
Просмотров 9 млн