Тёмный

How To Connect Multi Wires AC Motor With A Capacitor Attached? 

DIY made
Подписаться 2,8 тыс.
Просмотров 5 тыс.
50% 1

The content in this video will be showed: How to identify & connect a single phase AC motor of 230 V with multi wires & a capacitor attached? In other words: First to figure out which wire to which, then connect them accordingly such as which wires to a capacitor, which wires to the Live Power etc. Step by step in details.

Опубликовано:

 

4 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@edwinlipton
@edwinlipton 3 месяца назад
Slow enough I fell asleep. But I saved it too "watch later". Better than my old way of figuring them out. Doing it by trial and finally smoke out.
@diymade2175
@diymade2175 3 месяца назад
Good luck next time!
@yoheihattori452
@yoheihattori452 2 месяца назад
this is exactly I wanted to know the AC single phase motor, so, 2 winding opposite side, 1 neutral point, 1 phase and another phase has 3 cables in different position to create difference in resistance.
@diymade2175
@diymade2175 2 месяца назад
Thanks & glad it helped 👍
@kevinc1651
@kevinc1651 4 месяца назад
11:45 can white wire be used as live wire and black as neutral??
@diymade2175
@diymade2175 4 месяца назад
Yes, certainly however the motor will turn the different way around. Cheers!
@salaihtankee
@salaihtankee 5 месяцев назад
If you know why the motor of the washing machine is not spinning, please explain
@diymade2175
@diymade2175 5 месяцев назад
Thanks for the interested unfortunately I'm not a right guy you've asked. I think you can find some channel(s) regarding your concern. Good luck!
@bulla8631
@bulla8631 9 дней назад
why the capacitor is needed for the motor to do what to keep the motors running smooth or something else
@diymade2175
@diymade2175 9 дней назад
Thanks for the interested & yes, you've spotted one thing on! To put it in the simplest way for answering: The reasons for attaching a capacitor to a single phase AC motor are (1) Easy to start motor & then run it smoothly as you've mentioned. (2) To improve Power Factor because the coils inside AC motor as whole can be seen as an inductor in the AC circuit, so you might have known already - an inductor has the voltage 90 degree advanced over its current however a capacitor has the voltage 90 degree behind its current, in practical circuit a capacitor & a motor together will compensate some phase angles each other but all, that will be the result for improving Power Factor for whole grid system (for your own benefit, improving Power Factor, the less current goes through your home elec meter, the less the power bill you have to pay).
@eugeneisaac6731
@eugeneisaac6731 6 месяцев назад
I have a 230v motor with. Four wires..how do i connect
@diymade2175
@diymade2175 6 месяцев назад
Thanks for your interested! You'd have known how to connect your 230v motor with four wires if you watched the whole video carefully. Anyway, some suggestions are here: make sure there is no Earth Wire among four wires. Name four wires as A, B, C & D. Using a multi meter ohm position to measure following two wires resistance such as A-B, A-C, A-D, B-C, B-D & C-D, then chosen highest resistance's two wire for connecting a capacitor. Connecting Neutral Wire (N) from the power to the one of wires from capacitor then connecting Live Wire (L) from the power to the one of the two wires left. That's it. P. S. -- So far three wires from the motor have been connected, last wire which has not been connected yet, that wire would be slow speed or high speed wire depending on Live Wire (L) connected to the wire was high or low speed. Also this conclusion supposed all group wires you measured, no zero value among them. Good luck. 🤜🤛
@edwinlipton
@edwinlipton 3 месяца назад
Connect one with another till it smokes, then your really done.
@diymade2175
@diymade2175 3 месяца назад
No, no, I'm sorry to hear that! If your motors are reasonably good condition, they should be okay for testing run so long as you followed the steps in the video or above. I'd reckon you'd mismatched or accidentally connected wires such as connected the power wires (L & N) to between low and high speed wires, this was one of the most likable reasons for smokes from motors because the value of impedance between low and high are much much lower than the value of impedance from normal operating coil for that motor. Good luck next time!
Далее
How To Generate AC 230 V output From Car's Alternator?
7:35
Capacitor and Hard Start Myths Busted
28:41
Просмотров 221 тыс.
Советы на всё лето 4 @postworkllc
00:23
Capacitor Safety - How to Discharge Capacitors Safely
9:11
how to test a RUN or START CAPACITOR the CORRECT way
7:35
HOW TO USE A THREE TERMINAL SWITCH?
5:44
Просмотров 3,4 тыс.
How to Wire a Drum Switch to a 220 Volt Motor
10:19
Просмотров 6 тыс.
Motor speed color code
4:12
Просмотров 213 тыс.
How to Replace a Motor Capacitor
6:11
Просмотров 14 тыс.