Тёмный
No video :(

How to Cut Cast Iron Pipe [Learn how to cut, remove, and replace cast iron sewer pipe with PVC] 

Andrew Thron Improvements
Подписаться 290 тыс.
Просмотров 109 тыс.
50% 1

Опубликовано:

 

22 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 170   
@rasandberg
@rasandberg Год назад
I appreciate what you taught me in this video about cutting cast iron pipe. I bought a Diamond Grit 8-in Grit-TPI Wood/Metal Cutting Reciprocating Saw Blade. I needed to make three cuts in a 14 ft long section of 100-year-old cast iron pipe. I made the first cut, and when I was close to the bottom it just snapped and broke in two. What I discovered was that by taking a sledgehammer to the pipe after cutting it a few inches deep, the pipe just shattered. Done. Much easier and continuing to cut with the blade.
@DavidSmith-ym9yz
@DavidSmith-ym9yz 3 года назад
Constructive feedback. For the clean out, don’t bushing down to 2” or 1 1/2. Use a small hub-hub piece of the same size pipe, with a female adapter with plug. Allowing bigger size cables to be ran through the line. This restricts plumbers to smaller machines that may not have the power to cut through hard clogs. Second is ferncos are illegal to use unless underground. They provide flexibility to joints, so a sewer line won’t break while the ground settles. Mission bands (fernco with metal sleeve) are used inside homes. Makes the joint more structured, and doesn’t allow it to sag/move. Other than that it looks decent coming from a plumber. Minus the amount of fittings lol. Practice always helps.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
Thanks for the feedback! Believe it or not, that clean out was originally a 1.5” vent. I thought I needed to tie a vent in there but the inspector told me to remove it. I was left with the 1.5” stub that I converted to clean out. You live and learn. As for the Fernco, that was just an ignorance error on my part. But oddly enough, the inspector didn’t mention anything about it. Lastly, since you are a plumber, do you have a ballpark number that you would charge for a job this size? Thanks again!
@sheilaa1333
@sheilaa1333 3 года назад
I’d love to know a ballpark estimate too (high and low because I live in a ‘high’ area...) and want to know whether it’s worth it to attempt myself. 😁. (We got a permit so an inspector will check my work. 😬)
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@@sheilaa1333 I received a rough in plumbing estimate for $3500 for all rough in plumbing. So after purchasing materials, you could save around 2.5-3k. But plumbers do have a lot of code knowledge etc. So it’s hard to put a price on experience. Good luck!
@sheilaa1333
@sheilaa1333 3 года назад
@@AndrewThronImprovements Thank you so much!
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@@sheilaa1333 good luck with your project!
@tonyburry9036
@tonyburry9036 Год назад
My boys saved $32,465 bucks from not calling the plumber I love it!! Super dope keep them coming.
@ptech88
@ptech88 8 месяцев назад
Was the plumber using gold fittings?
@meredithcarroll6209
@meredithcarroll6209 3 месяца назад
Thank you so much for this video. We have a very old but still sturdy cast iron main line. The problem is the house is also old and when they did the back addition with the bathrooms they left absolutely no way to add any new fixtures (like a shower) without having to get behind the main line, up over the back wall of the foundation, and into a tiny crawl space. It's basically impossible to do without completely ripping out the floor, so we have to add the new fixtures where we can actually get to them. You have saved us easily $5k with this how-to.
@yvonne.stewart2745
@yvonne.stewart2745 2 года назад
My daughter and i did the main drain pipe some years ago replacing it with pvc. First time also by watching youtube. Now i see a pipe up in the celling that needs to be changed. For some reason I'm scared to tackle this one. I guess i would be the same. Pray for us. Thanks for your video very good.
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Good luck with your project, Yvonne!
@Eastbaypisces
@Eastbaypisces 2 года назад
which videos did u watch specifically that helped?
@yvonne.stewart2745
@yvonne.stewart2745 2 года назад
@@Eastbaypisces I'm sorry when we did that project it was some time ago I can't remember which one it was.
@awesomerpower
@awesomerpower 6 месяцев назад
@@yvonne.stewart2745how did it go? Very cool you and your daughter tackled this.
@yvonne.stewart2745
@yvonne.stewart2745 6 месяцев назад
@awesomerpower Thank you, sweetie. So far, we haven't tackled the other pipe as of yet. We have been working on other projects like the pantry. we guttered and did the sheet rock. it we had called a handling man who wanted to charge us 450.00 just putting up the sheet rock had nothing to do with the demolition or painting and shelfing. It came out beautiful. So next we have another project waiting to be started. A little at a time, but we're learning.
@SuperMeatFreak
@SuperMeatFreak 2 года назад
Way, way better than other vids I've watched. Thanks Andrew,, you were very helpful.
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Glad it helped! Thanks for watching, Lewis 👍
@heatherhunter160
@heatherhunter160 3 года назад
I love your videos. I just spent 45 minutes watching them. ❤️
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
haha I appreciate it, Heather! Sounds like my marketing department got to you. I need to give her a raise.
@melanielong6232
@melanielong6232 3 года назад
@@AndrewThronImprovements yeah ya do
@ethanwoodfield7075
@ethanwoodfield7075 3 года назад
Plumber from Canada here......the double wye on a horizontal is a no no when your trying to put fall to one side.....your putting back fall on the other side would have to use two separate wyes for that!🍻
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
That’s a good point! Appreciate the feedback. Definitely some lessons learned on this one!
@ethanwoodfield7075
@ethanwoodfield7075 3 года назад
For sure man its always a learning cure 11 years in this trade and still learning all the time keep up the hustle!!
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@@ethanwoodfield7075 Thanks Ethan! Canadians are nicer plumbers lol check out the comments lol. Take care!
@MrDmadness
@MrDmadness 8 дней назад
Over 30 years plumber here, also Canadian. A double wye on a horizontal is fine, you check the inlet for slope and make the branch level ( it is level on both sides ) if the inlet side gas grade then so do tge branches, 1/8 " / foot on 4" is easily achieved on a branch.
@terrencewatkins9311
@terrencewatkins9311 Год назад
Hey man, constructive criticism from a plumber, next time you do something like this, read the code book on orientation of fittings and dry/wet/individual venting or just hire somebody that knows what there doing.
@BlueAlgon
@BlueAlgon Месяц назад
Thanks for posting this.
@DannyFourSquare
@DannyFourSquare 3 года назад
Very nice man, I'm getting rid of cast iron right now and your video was helpful.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
I appreciate it! Definitely a messy job, but not too bad. Good luck with your project!
@oldowl4290
@oldowl4290 Год назад
1:45 I would also add that you want to flush your toilet at least 5 times if not 10, to assure you that last nights dinner will not be staring you in the face once the pipe is cut. Huge oversight there. Secondly, with that much space around the pipe, an angle grinder with cutoff wheel would cut the pipe in 1/4 the time as any sawzall.
@toby16custom
@toby16custom Год назад
Sawzall blade: Milwaukee makes a cast blade for this torch with nitrus
@capitallighting7053
@capitallighting7053 Месяц назад
why did you use the fernco? as opposed to a band that is rated for that transition from cast to pvc, or at least something more durable that wont give easily. plumbing looks clean though!
@Dudjrkfjjffjkffu
@Dudjrkfjjffjkffu 12 дней назад
It’ll work just fine. I would have picked up the lav farthest upstream and I would have omitted the dry vent for the tub. If you piped it this way, the tub and toilet would be wet vented off of the lav. I would have gotten rid of the shower vent because code does not allow you to travel horizontally with your vent until you are a minimum of 6 inches above the flood rim of the fixture that you’re serving.
@MrDmadness
@MrDmadness 8 дней назад
It's literally not to code on so many things.
@Dudjrkfjjffjkffu
@Dudjrkfjjffjkffu 7 дней назад
@@MrDmadness it’s not so bad that it won’t work🤷‍♂️
@MrDmadness
@MrDmadness 7 дней назад
@@Dudjrkfjjffjkffu thats true, my primary issue here is that hes made an "instructional video " while not knowing any code. How does a guy teach if they do not know ?
@chrismallory3718
@chrismallory3718 9 месяцев назад
Cannot use a double wye on a horizontal, you wont get correct fall on 1 side. You will have issues in near future
@LowDoughTech
@LowDoughTech 3 года назад
I had to do this a few years ago when my ancient iron drain busted. I used an angle grinder with a cut off wheel to get the old pipe cut out, I was left with a small section where I couldn't fit the grinder, and I finished off that small cut with a hacksaw.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
It's not the most pleasant job, but someone has got to do it! Thanks for watching!
@tylercourtney3040
@tylercourtney3040 2 года назад
Good video. Curious to know, doesn’t the shower and the faucet each require their own individual vent line? It looks like you tied the shower and faucet drain into the primary toilet drain but are relying solely on the primary toilet vent. Is this correct? I ask because I’m tip toeing into a very similar project myself. Thanks man!
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Hi! Believe it or not, I learned everything from RU-vid lol. I bought this house a couple years ago knowing nothing about home improvement. Thanks for watching!
@ironmyno
@ironmyno 2 года назад
I'm a Journeyman Glazier and did a bit of home remodeling before rhat and your tackling stuff I feel is forbidden territory!
@zwhit_0122
@zwhit_0122 2 года назад
The shower/tub has a built in vent with it. As for the toilet the way I normally do it is use a 3inch combo fitting and out of the back side go up with a 90 so I can shoot a 2in vent in the wall and out the roof. As for a sink you can stub directly up and using a a san tee add an studor vent and p trap.
@IHateHandleNames
@IHateHandleNames Год назад
Depends on your state. Kentucky requires individual vents that tie in everywhere. Some states go off international code. Some go off national code. Some go off of a state code. It's better to individual vent everything, if you ask me, but other plumbers will differ in opinion.
@MrDmadness
@MrDmadness 8 дней назад
​@@AndrewThronImprovementsI believe it, that's why the installation has code violations. To the o.p, Individual vents are not required but are ideal but they must be taken off tge top of the trap arm in a vertical configuration ( a wye and a 45. ) they must be wye and 45 becauee they are below flood rim and so just not be T fittings. If you have a 3" branch serving the toilet its common to take a 2" why off to the lavatory ( this is a wet vent) and pick up the tub The 2" is the wet vent for the w.c and the shower then . This video shows improper plumbing
@aspensplace3293
@aspensplace3293 Месяц назад
Well done.
@RD-sl8yl
@RD-sl8yl 9 месяцев назад
Extremely helpful video!!! Thank u!!
@junkemails5050
@junkemails5050 2 дня назад
The cast iron section will continue to rust, will get clogged and these connection will get stuck the snake bore when trying clean it
@yeahboyeehager9452
@yeahboyeehager9452 3 года назад
Everything I needed to know...Thanks.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
Glad it was helpful and I hope your project goes smoothly! Thanks for watching!
@raoulloustaunau8233
@raoulloustaunau8233 2 года назад
Try placing your Sawzall firmly on the pipe all the way till it hits the guard it speeds up the cutting.
@awesomerpower
@awesomerpower 6 месяцев назад
When I do that it vibrates the pipe a lot. Maybe cast iron doesn’t vibrate like galvanized?
@Eastbaypisces
@Eastbaypisces 2 года назад
which videos did you watch to learn how to do this? also how did u go about getting an inspector? did u have to call them and tell them and then they showed up after?
@tipperzack
@tipperzack 3 года назад
Instead of killing your wood saw use a metal file to start your metal cuts.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
That’s a good tip, thanks!
@kelvindunn4187
@kelvindunn4187 3 года назад
Grinder works well also
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@@kelvindunn4187 agreed - thanks for watching!
@toddcramer3010
@toddcramer3010 2 года назад
That was a good explanation.
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Glad it helped, Todd! Thanks for watching!
@craigwyss6035
@craigwyss6035 Год назад
The bell and spigot joints contains asbestos packing,we have to remove them under Abatement protocol.
@eegg6954
@eegg6954 7 месяцев назад
Here in New York they are oakum, which is horse hair.
@kyleblake6299
@kyleblake6299 3 года назад
Holy offset
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
yea...it was pretty brutal
@LC-cz2pg
@LC-cz2pg 2 года назад
Wow!!! Great job!!!!
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Thanks for watching!
@gregwhitten6886
@gregwhitten6886 3 года назад
Any idea how much a plumber would charge for a similar job? I would rather hire a plumber, but I’ll probably tackle it myself if the price is high.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@gregwhitten Thanks for the comment! I got a quote from a plumber for the full bathroom rough in (converting from a half bath to a full bath) for $3,525. I would estimate that for all of the work shown in THIS video, the cost would be around $2,500. However, I would love to get pricing feedback from viewers who are licensed plumbers. Comments welcome!
@curiouscat3384
@curiouscat3384 3 года назад
@@AndrewThronImprovements Yikes! prices probably vary depending on location and whether you hire a self-employed plumber with lower overhead. I hired a small company (3 guys) last year to replace all the old galvanized supply and drain lines in a literal crawlspace for kitchen and 1 bath. Adapted to cast iron main stack. 2 days work, licensed and inspected $3500 in Piedmont NC. Doesn't hurt to get 3 estimates :)
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@@curiouscat3384 that’s not a bad price at all! The company I had take a look was definitely on the larger side. I guess that was my first mistake. And you are right! After the first quote I just shook my head and resolved to do the work myself. Thanks for watching!
@aarontheller5270
@aarontheller5270 4 года назад
Intimidating DIY project 😬
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
It's actually not too bad! Just a bit messy at times.
@valery5969
@valery5969 7 месяцев назад
I would like to attend your practica class.
@CitizenShane
@CitizenShane 2 года назад
Just curious: why not use a 3x2x2 inch double wye for that sink drain instead of running it over the 3 inch line to tie into the tub trap?
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Thanks for watching! Honestly, If I could do the plumbing again, I would have made a lot of changes (your suggestion likely being one). It passed inspection, but a lot of what I did was inefficient.
@awesomerpower
@awesomerpower 6 месяцев назад
@@AndrewThronImprovementsdid you ever do a folllw up vid explaining this? Might be helpful and I’d bet it would get a ton of clicks. Either way, thanks for your work, it’s a good helpful vid and your responses to commenters is pure class. It’s so great when these discussions can be had, it contributes to everyone’s knowledge.
@markbomba1307
@markbomba1307 3 года назад
Why would you not replace all cast while doing the project?
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
I thought about....but I figured I would “get my feet” wet with a smaller section before committing to the whole thing. In hindsight, definitely should have just knocked it all out. You live and learn. Thanks for watching!
@PolaCaKe890
@PolaCaKe890 Год назад
thank you, doesnt look that scary to do afterll
@zar187
@zar187 Месяц назад
why didn't you replace all the steel pipes?
@willwen6600
@willwen6600 3 года назад
If there is a rusted spot on the iron which is leaky, any way to patch it up? Like maybe using epoxy putty?
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
In all honesty, this is a better question for a professional plumber. But I would for sure try to patch it with some putty (JB Weld steel stick maybe 🤔) before I would try cutting. Might need to make the more permanent switch to PVC in the future though. Thanks for watching!
@AdamTheVAST
@AdamTheVAST 2 года назад
It depends on where the leak is, but I've seen plumbers use molten lead to fill cracks on iron waste stacks before.
@zwhit_0122
@zwhit_0122 2 года назад
Don't use putty. Don't it right just cut a chuck out and replace it a piece of pvc and two boots
@lydiahubbell6278
@lydiahubbell6278 2 года назад
The pipes I will be working on should be dry inside.. Have not been used for years. Can you cut in smaller sections to make it a one-person job taking the old pipes out?
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Absolutely - it's just kind of a pain to make more cuts than you absolutely need to. Thanks for watching!
@awesomerpower
@awesomerpower 6 месяцев назад
You could pre-suspend a larger section with a couple ratchet straps and ease it down, I suppose. I have noodle arms so I always have to think up solutions like this.
@AlessioSangalli
@AlessioSangalli 2 года назад
When i do some plumbing at home with PVC, I always take care to wipe the primer very well so it doesn't show. I really hate the looks of dripping primer! Your saw blade must have been really good. I wasn't able to cut cast iron with mine, it wouldn't touch it. I had to use an angle grinder!
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Angle grinder also works well! Pipe snap cutter is also probably a better bet than a reciprocating saw. Thanks for watching! Appreciate the support!
@AlessioSangalli
@AlessioSangalli 2 года назад
@@AndrewThronImprovements I did not know snap cutters existed. I just watched a video about those, impressive. Thanks for the info!
@zwhit_0122
@zwhit_0122 2 года назад
Most inspectors want a thin ring of purple primer outside your fittings
@whocares8158
@whocares8158 Год назад
That’s weird I love the look for some reason
@awesomerpower
@awesomerpower 6 месяцев назад
@@whocares8158me too, it says the work was done and not just slapped together.
@donaldmcclure9062
@donaldmcclure9062 Год назад
Did you touch on slope?..
@fycyoungst3r538
@fycyoungst3r538 2 года назад
Fairly new to this kind of stuff but wouldn’t abs be better than PVC?
@DeathAngelHRA
@DeathAngelHRA 2 года назад
Negative. ABS is not allowed in many areas as the connections come loose and poor quality in manufacturing of the recycled-materials pipe.
@lydiahubbell6278
@lydiahubbell6278 2 года назад
A friend of mine dumps a couple bags of kitty litter underneath.
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
That's a good idea!
@donaldmcclure9062
@donaldmcclure9062 Год назад
Doesn't plumbing code require a slope of .125"???
@DJjosher
@DJjosher 2 года назад
Are those steel pipes typically screwed in or caulked in?
@zachcoleman6285
@zachcoleman6285 2 года назад
Back when cast iron was installed, lead and oakum was used
@Chrominance87
@Chrominance87 Год назад
They're not steel, they're made of cast iron.
@valery5969
@valery5969 7 месяцев назад
Where are you located
@elvismoyo6672
@elvismoyo6672 Год назад
What is the name of that black fitting used to join cast iron and pvc
@AndrewThronImprovements
@AndrewThronImprovements Год назад
I call it a "Fernco". Thanks for watching!
@awesomerpower
@awesomerpower 6 месяцев назад
Had to slide a couple ferncos over 2” galv yesterday. One got horribly stuck. A tiny amount of dish soap helped in the end.
@MrNeptunebob
@MrNeptunebob 3 года назад
Andrew, you don't need to use so much solder! Practice, do enough soldering and you should get better at it.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
I completely agree with you! That was only my second time soldering and, in hind-sight, I should have just used CPVC. That was a lot of overhead pipe to be soldering. Thanks for Watching!
@jtfox8851
@jtfox8851 3 года назад
Hell yeah bro
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
Appreciate it, man! Thanks for watching 👍
@richardj5417
@richardj5417 3 года назад
Fucking painful to look at.
@marmarc4203
@marmarc4203 2 года назад
Which is better PVC or ABS BLACK????
@DeathAngelHRA
@DeathAngelHRA 2 года назад
PVC Schedule 40 is the most common residential sewer pipe. ABS has been banned in many areas for use due to the connections becoming loose and defective pipe made from recycled materials.
@zwhit_0122
@zwhit_0122 2 года назад
I've had to fix more ABS then PVC
@fatimahtorres8105
@fatimahtorres8105 2 года назад
I can do this. I can do this. But it's just one pipe and it's already pitched down.
@browsetheworld4120
@browsetheworld4120 Год назад
Good video, very informative. But...are you saying "sawzaw" lol
@gregvitkow521
@gregvitkow521 2 года назад
Are you a licensed plumber?
@ElGalIo2
@ElGalIo2 3 года назад
If you’re not going to change the whole Cast Iron pipe ( even Underground) it’s pointless to change out a 5’ section.... Anybody that’s been in the plumbing field for a cool minute will tell you Cast and Galvanized pipes suck for waste. I’m curious as to how many leaks you had, I’d never use that small Dobber on 3” pipe.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
Zero leaks so far 🤞. And I agree that is would have been better to change out all the cast iron for PVC. I only replaced the 5 foot section so I could add new connections for a half bath to full bath conversion. First time doing something like this, so definitely some lessons learned for next time. Thanks for watching!
@RickysPlums
@RickysPlums 4 года назад
The finished product is incorrectly installed. You need a plumber my friend
@AndrewThronImprovements
@AndrewThronImprovements 4 года назад
Appreciate the comment Ricky! What looks incorrect? I had a plumber inspect the finished product and I actually had the whole thing permitted in my City and got approval. Appreciate your input!
@RickysPlums
@RickysPlums 4 года назад
Sanitary tee can never be used in the horizontal position, moreso if it's being wet-vented. It also is basically a crown vent now because of that same horizontal positioning. The double-wye looks back-pitched on one side (toilet side, but my eyes could be deceiving me.) The proper way to install a double wye is to level it first and then glue your fittings - you pre-fabbed your fittings and the back-pitch is a common result. You mentioned inspections, I'm surprised you passed because this would not be considered compliant with either the international plumbing code or the uniform plumbing code. Are you in a state that leaves code enforcement up to local officials?
@AndrewThronImprovements
@AndrewThronImprovements 4 года назад
@@RickysPlums In discussions with my plumber (I’m just a DIY guy), the long sweep 90 makes it acceptable. The pipe out the back is just a clean out. Pitch was confirmed to be ok, so that might be the camera angles. I’ll definitely glue the double Wye in place next time. That’s a good point and I’ve definitely run into issues before by pre-fab gluing fittings. Nope, we use IPC. Definitely still learning the nuisances of plumbing, but this was my first attempt at a project like this. Not saying it’s perfect, just my process for doing it. Appreciate your feedback!
@aroundthehouseEricG
@aroundthehouseEricG 4 года назад
@@AndrewThronImprovements Plus you used the wrong Fernco fitting. That one is designed for below grade applications. You need the metal wrapped one. Also you needed a fitting for the PVC to Fernco connection. I would have used a cast iron pipe chain cutter to cut the pipe. If you want to get sewage everywhere Milwaukee makes a cast iron Sawzall blade.
@AndrewThronImprovements
@AndrewThronImprovements 4 года назад
@@aroundthehouseEricG Thanks for the feedback, Eric! From my product research, the Fernco I used is “rated for underground applications” Which is likely a much harsher environment than indoors. But having the extra sheathing protection is never a bad idea if you want to spend the extra money. I am not familiar with the PVC/Fernco connection fitting - so please provide information (if you would be so kind) so that others DIY’ers can know their options. Lastly, I agree that chain cutters are the “right” way to do it. But I chose to save some money and go the rough and dirty route with tools I already had. Please keep up the constructive feedback. I will try and publish all the tips/comments so that others can be aware of what I did right and what I should have done differently. Thanks!
@jacksplumbingvideos7147
@jacksplumbingvideos7147 4 года назад
The new pvc was wrong it had San tees on there back it had small cleanouts on big pipes it is a mess
@AndrewThronImprovements
@AndrewThronImprovements 4 года назад
Appreciate you sharing your opinion! However, it was hard to make out what you are trying to say in your comment. Without knowing the full arrangement or knowing the specifics of the project, I do not know if are in a position to call the work “right” or “wrong”. But I appreciate you watching and I agree that the work does look like DIY job and is not exactly the most ‘professional’ looking in terms of appearance.
@jacksplumbingvideos7147
@jacksplumbingvideos7147 4 года назад
Andrew Thron Improvements it just needs to be simplified
@YungPlumber1
@YungPlumber1 2 года назад
Handyman plumbing indeed according to UPC code.
@everythinghomerepair1747
@everythinghomerepair1747 2 года назад
You’re lucky if you have cast iron exposed like that in the basement. In many states with slab houses the cast iron was buried under the concrete slab.
@AndrewThronImprovements
@AndrewThronImprovements 2 года назад
Agreed! This was best case scenario. Thanks for watching!
@MrDmadness
@MrDmadness 8 дней назад
There is literally nothing youve done here that is to code, it will syphen, tdaps will not hold gas back, it will girgle and clog. Hire a plumber duee, youre not one
@adamantitul
@adamantitul 11 месяцев назад
🤗
@JTTTTx
@JTTTTx 10 месяцев назад
Plumber here- painful to watch. Ss banded couplings only, double y on the flat, wrong fittings below the flood rim and many more.. Please viewers, this is not the way to repipe this. No way that passes any inspection. More RU-vid plumbing- not a complement, sorry.
@lachcik5084
@lachcik5084 3 месяца назад
no.
@jasonjean398
@jasonjean398 3 года назад
This is Mickey Mouse work….. but we gotta learn somehow. ✊🏿 good stuff
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
Totally agree haha Thanks for watching!
@ValioMadre7
@ValioMadre7 Год назад
Plumbers charge more than a gynecologist.
@PlasticPellets
@PlasticPellets 2 года назад
McD?
@lakestatebullies7391
@lakestatebullies7391 3 года назад
This is a mess wrong fittings all over it. This is the reason people have backups and then they aren't able to clean them out.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
I agree that it definitely could have been simplified. The retrofit made it a bit tricky. Thanks for watching!
@TrainFlood
@TrainFlood 6 месяцев назад
No gloves!!
@PrivateChannel1300
@PrivateChannel1300 3 года назад
The city/county inspection should be fired for passing this.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
If you want to provide more insight on what exactly you see that should result in a failed inspection, it might actually help someone else out! Thanks for watching
@jklsr55
@jklsr55 3 года назад
@@AndrewThronImprovements Your toilet in not vented... That should be a 90 and not a combo fitting on your toilet... The bath tub is vented with a tee on its back which is a code violation...
@jklsr55
@jklsr55 3 года назад
@@AndrewThronImprovements Some inspectors are not licensed plumbers in many jurisdictions I have found. Will all this plumbing indeed "work"? For the most part. Buy is it code UPC code correct? No it is not.
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@Jeff Legg Thanks for taking the time to watch and comment! This was my biggest plumbing project to date, so it was a bit of a learning process. For the toilet, I originally had it vented where you see the stub with a cleanout cap in the video. The inspector actually told me to REMOVE the toilet vent and just cap it - like you see. This did not make a whole lot of sense to me, but I just did what he said so that it would pass. The bath tub plumbing was existing, I did not change anything with that. So it is very possible that there are issues. Thanks!
@AndrewThronImprovements
@AndrewThronImprovements 3 года назад
@Jeff Legg we operate under IPC - I am not sure how different UPC and IPC are. Thanks!
@spectraldrew
@spectraldrew 2 года назад
You literally put a plastic bag on your face and put it in a how-to video. You should NEVER put a plastic bag on your face. Buy a face shield.
@troyelder56
@troyelder56 Месяц назад
You used the wrong fernco 🫤 suppose to be a 3x3 pvc to cast iron fernco since outer diameters are diff
Далее
Fastest Way to Cut Cast Iron Pipe
9:40
Просмотров 115 тыс.
How To Cut And Replace Cast Drain Pipe
14:24
Просмотров 689 тыс.
The BEST Way to Cut Cast Iron Pipe?
3:33
Просмотров 278 тыс.
How to Fix Leaking Cast Iron Pipe
17:10
Просмотров 87 тыс.
How to replace a main sewer line for ONLY $490
9:58
Просмотров 178 тыс.