Тёмный

How to decide the position and orientation of Columns? | Structural planning | Civil Tutor 

Civil Tutor
Подписаться 191 тыс.
Просмотров 153 тыс.
50% 1

In this lecture, I have discussed briefly how to decide the position and orientation of columns in a building structure which is going to be an add-on to your civil engineering basic knowledge.
Structural Mastery Certified Course
👇🏽👇🏽👇🏽
App link: play.google.com/store/apps/de...
Telegram link:
t.me/+yCaB58hzlvQ1Mzk1
After framing an architectural plan of a building, structural planning is done by deciding the Position and orientation of columns followed by positioning of beams, spanning of slabs, the layout of stairs and finally selecting the proper type of footing. Overall, the basic principle of deciding the layout of these components is the transfer of loads from the superstructure to the foundation along the shortest possible path.
The columns should be oriented in a way that the depth (i.e. shorter side) of the column is perpendicular to the major axis of bending. In simple words, when a column is connected to beams, it is subjected to moments in addition to the axial load. That’s why the shorter side of the column should be aligned perpendicular to the major axis of bending. This way, we can get a larger moment of inertia which means a greater moment-resisting capacity.
Compiled PDFs
store.civiltutorofficial.com
Must-have books for civil engineers 👇🏽
The A to Z of Practical Building Construction and Its Management
amzn.to/3HKmjm9
Building Planning and Drawing
amzn.to/3sPztdA
Illustrated Design of Reinforced Concrete Buildings ( Design of G+3 Storeyed Buildings + Earthquake Analysis & Design)
amzn.to/3tD9aGq
Advanced Reinforced Concrete Design
amzn.to/3IRZwGn
Limit State Design of Steel Structures
amzn.to/3pIk1O6
Estimating and Costing in Civil Engineering (Theory and Practice)
amzn.to/3IWcwLq
The mic I use👇🏽
amzn.to/35ejhcN
#structuraldesignanddrawing #civiltutor #columndesign
►DISCLAIMER
The information provided in this video is for educational purposes only. The viewer is solely responsible for verifying the information and the use of the information in this video is at the viewer's own risk. The content is not intended to be used for professional or commercial purposes. The application of the information presented in this video on a construction site should be carried out only by a licensed and qualified civil engineer.
This video may contain copyrighted material the use of which has not been specifically authorized by the copyright owner. However, under Copyright Disclaimer under Section 107 of the Copyright Act 1976, allowance is made for fair use for purposes such as criticism, comment, news reporting, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.

Опубликовано:

 

4 июн 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 72   
@CivilTutor
@CivilTutor 2 года назад
Structural Mastery Certified Course 👇🏽👇🏽👇🏽 App link: play.google.com/store/apps/details?id=co.kevin.emmuo Telegram link: t.me/+yCaB58hzlvQ1Mzk1
@abduljaffar5870
@abduljaffar5870 2 года назад
Brother could you give your contact number or mail id. I have some doubts about Structural Engineer mastery course
@tylervalenz9692
@tylervalenz9692 Год назад
Please I'm finding difficulties installing the app
@rajkumarr759
@rajkumarr759 2 года назад
Simple and easy concept which, many of my lecturers used to avoid answering this questions but after this explanation I felt easy. Thank u for teaching this
@CivilTutor
@CivilTutor Год назад
Glad to hear that
@Gana_garani21
@Gana_garani21 Год назад
Me too
@thesavagecivilengineers9097
Simple concept...align the column along long wall...at intersection cancel out opposite length then consider it...we always increase depth instead of width because in column and beam with depth moment of inertia and section modulus both increases which decreases the bending stress in our structure...bending stress is M/Z so Z increases ratio decreases...Z= bd²/6 for rectangle shape...also Z = I/Y ...so more inertia more section modulus..more strength to structure...everything is interconnected. 👷
@kingfestus
@kingfestus 2 года назад
Sending love and Success to all the hardworking Engineers 👷‍♂️🔥
@vaishnavisharma7718
@vaishnavisharma7718 24 дня назад
Thnx for providing these type of usefull lectures...Really nyc🎉
@blessingchinda3223
@blessingchinda3223 13 дней назад
This is a beautiful and explicit presentation. Please something like this is needed on manual design of steel tank stand carrying 20,000gal. water tank. Thanks Blessing Chinda
@abdulmonimmohamedali9146
@abdulmonimmohamedali9146 2 года назад
Always you give us an important concept, thanks.
@zbx963
@zbx963 Год назад
Great explanation... such videos before it I will never see
@Din_Djarin69
@Din_Djarin69 2 года назад
THank you for this useful information. Very helpful :)
@sravankumarkumandankothako2294
@sravankumarkumandankothako2294 2 года назад
Very good clarification on orientation of columns Thank you
@parthosen9278
@parthosen9278 10 месяцев назад
Very informative and useful video ...😊❤
@joannemalubay4355
@joannemalubay4355 Год назад
Thank youuu 😭😭 really helped me a lot
@farmanmaldar573
@farmanmaldar573 2 года назад
Sir u are great really💯 Your quality of teaching indeed it has to be appreciated👏🏻💯👍🏻
@CivilTutor
@CivilTutor 2 года назад
Thank you so much! 🙏
@ziauddin7948
@ziauddin7948 Год назад
excellent column positioning rule based on span of crossing beams & width & depth of column #❤️👍
@jamalnasarlodin372
@jamalnasarlodin372 2 месяца назад
Thank you for your nice lecture ❤
@user-zm6fh4hn6w
@user-zm6fh4hn6w 2 года назад
super explanation.
@elanchsuriyan9078
@elanchsuriyan9078 2 года назад
Thanks a lot sir
@kousikdey7989
@kousikdey7989 2 года назад
Thank you so much
@krishnamurthynarayana.505
@krishnamurthynarayana.505 2 года назад
Very essential for me
@Er.Krishnamoorthi
@Er.Krishnamoorthi 2 года назад
Super video sir
@sandeepnavale500
@sandeepnavale500 2 года назад
Good explanation
@romiosvlog7100
@romiosvlog7100 Год назад
Very helpful
@shaibmanzoor7650
@shaibmanzoor7650 7 месяцев назад
Jazakallah khair azizil mudaris
@vipulbhoir8451
@vipulbhoir8451 Год назад
Biggest thanks...
@ajinkyapatil1332
@ajinkyapatil1332 7 месяцев назад
Thanks...all dought cleared 👍
@CivilTutor
@CivilTutor 6 месяцев назад
Great 👍
@kingfestus
@kingfestus 2 года назад
Thanks 🙏
@oswald2358
@oswald2358 Год назад
Amazing
@user-kl1xc6ic8m
@user-kl1xc6ic8m 3 месяца назад
thank you! helps a lot
@CivilTutor
@CivilTutor 3 месяца назад
Glad it helped!
@pranotostb
@pranotostb 2 года назад
Good informasiont
@alexloh0213
@alexloh0213 Год назад
Hi sir, what if there is a beam (larger dimension) and other beam(smaller dimension)? it is still used the same way to determine it or the larger beam is always connected to the short side of the column
@vijayashalini3700
@vijayashalini3700 2 года назад
Sir can you please take online class Bar bending schedule
@nakshanavees
@nakshanavees 2 месяца назад
How to decide correct size of Column within detail of steel bars? Kindly upload detail video
@nicolasmarie4398
@nicolasmarie4398 Год назад
Here our beams are mostly 425x150 with the top of the beam being the thickness of the slab (125 mm.) The web part of the beam (height=300) is cast first to enable shuttering for the slab and the top part of the beam is cast together with the slab (=125mm). The slab is connected to the beam by its weight and by its reinforcement but they do not share a unified concrete cast. I will like to know how you consider the beam dimension in that case according to your code? Thanks.
@thesavagecivilengineers9097
Why don't you guys cast it all togeather which is the most appropriate way...🤔
@lipikamoharana8277
@lipikamoharana8277 Год назад
Sir in a building there is 12"*15" column size and 16mm 6 rods are provided, then what should be arrangement of rods in that column and why so.??
@vellaisamy8423
@vellaisamy8423 Год назад
Nice question
@khalidsikandar6772
@khalidsikandar6772 2 года назад
hi, from Pakistan, can you do tutorials in ACI using UBC code in version 16 Etabs??
@josh_up
@josh_up 2 года назад
same request!
@welbecksworld6531
@welbecksworld6531 2 года назад
Please which application software do you use to make your videos?
@CivilTutor
@CivilTutor 2 года назад
Kinemaster
@eliusdarius5341
@eliusdarius5341 Год назад
Hey I leave in st lucia how can I get this course
@shivamiltiwari9541
@shivamiltiwari9541 Год назад
can we do this course who are not student of engineer but have good knowledge nd interested ??????
@swapniljadhav6504
@swapniljadhav6504 9 месяцев назад
🙏🙏
@eliusdarius5341
@eliusdarius5341 Год назад
How can I take this course
@faaziazhar9737
@faaziazhar9737 Год назад
How to contact
@GautamRout-mz1mj
@GautamRout-mz1mj Месяц назад
According to IS 13920, shortest dimension of columns should not be less than 300 mm. So should we improvise it?
@CivilTutor
@CivilTutor Месяц назад
Only if you are doing Earthquake design.
@md.abdullah6566
@md.abdullah6566 2 года назад
Assalamualaikum sir.I want to buy the course from civil fields trainer.How to confirm and contact you before buying the course??
@CivilTutor
@CivilTutor 2 года назад
Check out the link in the description box
@farazraza3232
@farazraza3232 5 месяцев назад
Basically beams should be perpendicular to the max span of column
@unityindiversity8964
@unityindiversity8964 Год назад
Column size 230 * 230 means square ......but u show rectangular........for square column no need of orientation
@anandgor4181
@anandgor4181 Год назад
Can i join combo course now.?
@CivilTutor
@CivilTutor Год назад
yes you can
@anandgor4181
@anandgor4181 Год назад
What's charge for it?
@rishada2819
@rishada2819 2 года назад
I want course nmbr pls
@CivilTutor
@CivilTutor 2 года назад
Structural Mastery Certified Course 👇🏽👇🏽👇🏽 App link: play.google.com/store/apps/details?id=co.kevin.emmuo Telegram link: t.me/+yCaB58hzlvQ1Mzk1
@engineerahmad5279
@engineerahmad5279 5 месяцев назад
Sir... please Hindi me bhi translation Kara kijiye, ya alag se bana Diya kare. Or sir humko apna Structure Design pakka karna hai yani or seekhna chahte hai. Please help us 🙏🙏🙏.
@CivilTutor
@CivilTutor 5 месяцев назад
Subscribe to Civil Tutor Hindi channel
@forthesociety-jg9un
@forthesociety-jg9un 2 года назад
sir your address
@dhrubajyotiray5299
@dhrubajyotiray5299 2 года назад
Not clear...
@walliykipps
@walliykipps 2 года назад
Please what is ur telegram account
@faaziazhar9737
@faaziazhar9737 Год назад
How to contact
Далее
How to Find Column Position? in House Plan
6:32
Просмотров 83 тыс.
House construction process step by step
24:09
Просмотров 1,7 млн
Master Column Orientation in under 11 Minutes!!!
11:38