How to DESIGN and COMPUTE a SEPTIC TANK | Revised National Plumbing Code PH |Quick Tips 

Raw House Architects
Подписаться 11 тыс.
Просмотров 65 тыс.
50% 1

This video tells you on how to properly design a septic tank in a residential project. No to copy paste septic tank details. Learn the needed volume and right dimensions for your future reference.
TAKE NOTE : In septic tanks having over 6 cum capacity, the secondary compartment should be not less than 1.5 m in length.
While there are listed design considerations that are not tackled like pipe size,slope,distance of pipe etc. This is just a preview of a septic design for size configuration. I will a make video for the right technical specs and considerations. Thanks!

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 152   
@danieldemayo2303
@danieldemayo2303 4 года назад
Really love the educational content of your vlogs!
@remilopingol709
@remilopingol709 4 года назад
Most of our computations for plumbing are based on the books of FAJARDO and SALVAN since yan ang books natin noon sa college and I see meron pagkakaiba sa results when we use itong NATIONAL PLUMBING CODE. I am glad na sa computation ng Septic Tank You taught using NPC. Will you make other computations teachings like soil and waste pipes, storms and also vents using NPC. Thank you. I am also an Architect and RMP.
@christinedevera4267
@christinedevera4267 3 года назад
Thank you, Ar. sobrang helpful po para sa plate namin sa Building Utilities 🤗
@taengoo4263
@taengoo4263 3 года назад
Good day Ar.! Thank you for such an informative video. Question, I tried to compute the septic tank dimensions for a house with 1 or 2 bedrooms and I got 1.50 x 0.90 x 2.10 M (length). The digestive chamber is 1.4 m and leaching is 0.70 m. Is the dimension enough or is it too small? And is a 500x500 mm manhole suitable for this dimension? Thank you!
@landodeniega3666
@landodeniega3666 4 года назад
Ndi pa nagasisimula yung topic.. like na agad.. more power..!
@hydrogenperoxide9995
@hydrogenperoxide9995 3 года назад
Laking tulong nito sir! Thanks!
@peterisidro9237
@peterisidro9237 2 года назад
Thanks Arch. Mabuhay ka po.😍
@miraflorrodriguez8728
@miraflorrodriguez8728 2 года назад
Architect our design of septic tank is this.. Depth 1.5m Length 2.2m Width 1.5m Our design has 4bedrooms with 3 full cr. Is the septic tank size right?
@hallelujahelohim289
@hallelujahelohim289 3 года назад
hi. I have land and im putting a house I need a well and a septic" The land is packed clay and water doesnt drain well Do you make a leech field so I dont have to always pump the tank? How can I keep the septic - and the, "leech field," from contaminating the well? How can I find how well the septic will drain on my land, and how far away the septic has to be from the well ?
@riccipaulinecuasito2734
@riccipaulinecuasito2734 4 года назад
May suggestion lang po ako Architect. Puede po ba kayong gumawa nang vlog on how to compute water tank for commercial buildings with 4 unit apartments on its 2nd level po? Please
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Ill do, computation ng water tank volume :) watch out
@angelicaaclan384
@angelicaaclan384 4 года назад
@@Rawhousearchitects hi po baka po pwede po gumawa kayo ng video for pump selection. and ratings nya,
@melvinquidong6280
@melvinquidong6280 4 года назад
May suggestion ako architect on your next tutorial about sana on computing schedule of loads for a residential building
@Rukawapun
@Rukawapun 2 года назад
Relate po dun sa "Hindi lang kinacopy paste sa AutoCAD" HAHAHA pero lesson learned
@sjb9627
@sjb9627 2 года назад
Sir tanong ko lng.! Dapat ba sementado ang sahig ng septic tank? Salamat po sa sagot!
@sonnyenriquez6779
@sonnyenriquez6779 4 года назад
San ba dumadaan ang pvc pipe ng toilet bowl mula sa second floor...sa poste ba or sa wall?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Wall and floor, depende po, bawal po sa poste
@barako888
@barako888 2 года назад
thanks, Architect John!
@ericputian975
@ericputian975 2 месяца назад
New subs here archi... im a former site supervisor ng mga hgh end houses...
@rainsselsadie5564
@rainsselsadie5564 4 года назад
Thank you sir ! Keep posting!
@melanielayos
@melanielayos 2 года назад
thank you po for this!
@bry.dionisiooooo
@bry.dionisiooooo 3 года назад
Thank you po Ar. Miranda! from TUP-MNL po very informative po yung video niyo!
@christianagravante9745
@christianagravante9745 4 года назад
Hi sir. New subscriber mo po ako. Sana gawa po kayo ng tutorial kung papaano mag compute ng SIZE OF GUTTER na gagamitin sa roof. Yung depth and width po ng gutter. Thanks. 👍
@noorrojas2006
@noorrojas2006 3 года назад
Suggested to Show in drawing (layout) and computation.
@JB-vy5cc
@JB-vy5cc 3 года назад
What happens to the effluent from the septic tank? Does it eventually reach a treatment facility like it’s supposed to or does it drain into a street canal that eventually goes to an estero or river and eventually to Manila bay?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
It should go to main public or private sewarage system. It should not go directly to canals,estero, river. Unless its a storm water
@foreverlovehijau4428
@foreverlovehijau4428 3 года назад
Sir,, ano po ang technique sa pag papagawa nang septic tank sa masikip na bahay. Ang plano po namin ilalagay namin ang septic tank sa gilid nang dingding nang bahay namin. Paano po yun sir, baka mag lick o baka,, ang tubig mag lick papunta sa kabila.
@herminioenricob.vicencio88
@herminioenricob.vicencio88 3 года назад
Comment lang: Hindi parehas ung mga unit symbols sa computation kaya medyo nakakalito dapat kung kukuha ka ng length (m) = cu.m / (width (m) x depth (m)). Anyway, thank you very informative.
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Thank you for the correction sir 😄
@xianwhite5538
@xianwhite5538 2 года назад
rEQUEST PO ako Ar. Kung Paanu ka Mag Compute ng Electrical at Plumbing baka meron ka pong Diskarte na mas mabilisan
@ramryanaumentado2771
@ramryanaumentado2771 4 месяца назад
meron po ba video pag estimate sa cistern tank?
@johnlewis3686
@johnlewis3686 4 года назад
salamat po architect, may tanong po ako, may nabasa po kase ako na dapat hindi dumiretso sa septic tank ung shower and laundry liquid waste since may mga sabon sya or chemical na pweding pumatay sa natural bacteria ng septic tank. so san po dapat mapunta ung waste na yun architect. salamat po sa sagot. solid viewer nyo po ako.
@ericaclavelgatcho1095
@ericaclavelgatcho1095 3 года назад
Bakit po may mga structures na naglalagay ng septic tank sa ilalim nito?
@kimdelrosario9227
@kimdelrosario9227 2 года назад
Hi. thanks for this informative video! I just want to ask if there is a required minimum dimension for leaching chambers. can we build a leaching chamber that is less than 0.9M in width?
@anthonydale3660
@anthonydale3660 4 года назад
thanks sa clarifications po, tanong ko lang po, yung 3 bedrooms po ba recommended per how many persons? at ilan po idadagdag per person po kung sakali? thank you po
@juanball5480
@juanball5480 3 года назад
Nice tutorial
@christianperez8603
@christianperez8603 4 года назад
Thank you po Architect.
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Youre welcome! 🥂
@hanrielvengarcia2675
@hanrielvengarcia2675 2 года назад
Pag 1 room lang po paano po. 30sqm po ang bahay
@gelowthin1728
@gelowthin1728 4 года назад
Hi sir! Thank you po dito ! Sana meron po kayong Plumbing design methodology na maishare saming mga aspiring designer thanks!
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Consider natin yan sir, thank you!
@lerrybaltar1653
@lerrybaltar1653 4 года назад
Hi sir, paano po magadd ng new line kung gamit po namin ay anaerobic septic tank? Bubutas po ba kami sa mismong tank or magkabit po kami ng T pvc? Thanks!
@pandaypira4346
@pandaypira4346 3 года назад
Nice content.. sir tip lng sana next time yung mga illustrations or table n papakita mo lakihan sana.. di mkita yung mga values.. d kc lhat may book sir.. thank you. GODbless
@ebcmovies4071
@ebcmovies4071 4 года назад
Di po ba 3 chambers na nirerequire maski sa residential septic tank?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Yes, but in revised national plumbing code of ph, minimum is 2, you can add naman ung computed leaching chamber if needed sa specific municipality is 3 :)
@ebcmovies4071
@ebcmovies4071 4 года назад
@@Rawhousearchitects noted sir. Thanks!
@engrpogs
@engrpogs 4 года назад
May mga municipality lang po na ang requirement nila is 3chambers po 😐
@reggie7036
@reggie7036 Год назад
Hello Architect. Hinahanap ko ksi sa channel ung estimates for cistern tank. Parang nawala ata sa list. Thanks po.
@ryanestrada8486
@ryanestrada8486 3 года назад
sir ok lng po ba yung septic tank eh nasa ilalim mismo ng comfort room?
@triisha_
@triisha_ 4 года назад
are employees of a certain commercial establishment included in finding the width of the septic vault sir?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hi, septic vaults can only be used to residential projects, in a comml prject, you need na ng sanitary treatment plant, and the right professional to design that is a sanitary engineer :)
@Rawhousearchitects
@Rawhousearchitects 4 года назад
The sv would be huge if that so haha, kaya stp is needed na for that, the problem is the problem lol, You must also consider grease interceptors for the development, anyways i hope i answered your question indirectly hehe 🙏
@triisha_
@triisha_ 4 года назад
thankyou sir big help
@angelalacdao6336
@angelalacdao6336 3 месяца назад
Sir try nyo nga po sa 2500 gallons.. parang lalong lumiit yung sagot na nakuha ko? 😅 TIA
@mikemike4789
@mikemike4789 3 года назад
more plumbing videos please.. thanks
@jimboyocoy1444
@jimboyocoy1444 4 года назад
Hi Arch. Sa mga project ko ung kay Max Fajardo parin gngmit ko.. ok pba un? Thanks... -Jim UAP Qatar
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hi sir Jim, depende din po kasi sa designer, si fajardo kasi is like an additional reference. Pero I opt to choose RNPC guidelines kasi dun din kinukuha yung fixture units when designing sanitary and waterline. hope it helps thanks!
@jimboyocoy1444
@jimboyocoy1444 4 года назад
Ah ok sir.. baka may copy ka ng new RNPC? Pwd makahingi.. jimboy.ocoy89arki@gmail.com.. thanks
@Rawhousearchitects
@Rawhousearchitects 4 года назад
@@jimboyocoy1444 www.academia.edu/29988840/Revised_National_Plumbing_Code_of_the_Philippines.pdf dian sir pwede mo sya madownload :)
@jasmindizon
@jasmindizon 2 года назад
Salamat po Sir
@rufinojosesiapno420
@rufinojosesiapno420 4 года назад
Sir parang may mali po sa middle part. Yung Length value po ninyo... Bkit po naging cu. m. yung sagot?
@tranquilsoul411
@tranquilsoul411 2 года назад
this would be agreat help tip
@arvinlubugan481
@arvinlubugan481 4 года назад
Thanks Architect.
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Youre welcome! 🥂
@PlsJoshua
@PlsJoshua 6 месяцев назад
sa apartment and hospitals din po
@wotwot6868
@wotwot6868 4 года назад
Sir paano ba ako makakahanap ng Architect na based sa probinsya? At paano ko ma-sisigurado na kasing galing ninyo?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hi Sir, all licensed architects are from UAP/PIA kaya guaranteed ka, just ask first his/her license no and you can verify it to PRC. Sa I ilocos ,I have one friend na taga dian though dito sya sa manila nagwowork.
@vanessajade419
@vanessajade419 4 года назад
Thank you po Architect
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Youre welcome! 🥂
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Youre welcome! 🥂
@simply_pie
@simply_pie 2 года назад
Hello po, thank you for this helpful info po. Ask ko lang if sa building code po ba required na 3-chamber ang septic para maapprove ang building permit? 2 bedroom, 40sqm house, NCR location. Salamat po sa sagot!
@Rawhousearchitects
@Rawhousearchitects 2 года назад
Is it required na po, always use 3 chambers
@remilopingol709
@remilopingol709 4 года назад
Bakit yung ibang leaching chamber walang floor slab katulad ng Digestive? Tama ba yun?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Old practice but its not allowed since the soil can be contaminated po. Cocr. Slab is a must for all chambers sir :)
@MikeTuason
@MikeTuason 4 года назад
May video na ba yong kung saan lalagay mga pipings sa loob ng septic tank? ie, inlet pipe, outlet atbp. Thanks.
@kenhollom1669
@kenhollom1669 4 года назад
Why i not understand nothing his says
@eunjicho6448
@eunjicho6448 4 года назад
HAHAHAHAHAHHA
@rickers2011
@rickers2011 3 года назад
Sorry for this question but is it possible to install a septic tank above ground?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Your problem.would be the standard slope of the pipe, 2% slope to fully drain waste and water
@janlawrencealberto2678
@janlawrencealberto2678 4 года назад
Parequest po ng explanation pa ng ibang dimensions ng septic tank like baffle walls, height and diametet or pipes hehe
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Sige sir, add ako ng detailed septic tank descriptions with sizes
@roseannborja3815
@roseannborja3815 3 года назад
Good day po! Thank you for the helpful information Ar.! Ask ko lang po, how about pag 3 chambers naman po ang reqd. na i-design, applicable pa rin po ba yung 2/3 digestive and 1/3 leaching? If ganun po kasi sosobra na po sya sa nakuhang total length ng septic tank. How would you design po a 3 chamber STP if magbbase ka po sa Table B-2 of RNPC? Thank you po for responding :))
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Hi, add ka lang another 1/3 na nakuha mo
@roseannborja3815
@roseannborja3815 3 года назад
@@Rawhousearchitects Oww, okay po, bale okay lang po kahit mag-exceed ka po sa nakuha mong total length ng septic tank?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Yes Mam, pero you can seek sa DAO ng DENR, mas accurate po dun. Referal code lang kasi rnpc at medyo luma na
@roseannborja3815
@roseannborja3815 3 года назад
@@Rawhousearchitects Okay po. Thank you so much po, Ar.! God bless po :))
@giomel82
@giomel82 3 года назад
ilang taon po mapupuno ang tangke?
@rosemalang7215
@rosemalang7215 3 года назад
Ano ang size sa septic tank kong 4 bedroom sir
@enricolingo1977
@enricolingo1977 4 года назад
sir bigay ka idea mag kano costing ng balcony ng 2nd floor.
@kennethsabangan6842
@kennethsabangan6842 3 года назад
sir pwede makahiram ng sample niyo sa sanitary... 2 nd year arki po para lang sa assignment
@yamakayamada
@yamakayamada 4 года назад
Hi sir question lang po sa 3 chambers pano sya iaadd? Example 3 meters ung length nia ngayon tapos magaadd pa ulit ng isa so magiging 4m ung length nia? O isisiksik lang din sa 3 meters? Salamat po
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hi , add po uli ng lc
@yamakayamada
@yamakayamada 4 года назад
Ah okay salamat po
@arthurazataer1827
@arthurazataer1827 4 года назад
Idol pwede ka gawa ng video regarding inlet and outlet measurements and the pipe dimensions...tanx idol
@ramhaelespaldon3674
@ramhaelespaldon3674 3 года назад
Gawa kanaman boss ng calculation sa pressure req calculation sa pipe etc..
@Godblessforeveryone
@Godblessforeveryone 3 года назад
pano po ang sizing ng pipe? Salamat po.
@foreverlovehijau4428
@foreverlovehijau4428 3 года назад
Sir,, ano po ang technique sa pag papagawa nang septic tank sa masikip na bahay. Ang plano po namin ilalagay namin ang septic tank sa gilid nang dingding nang bahay namin. Paano po yun sir, baka mag lick at ang tubig mag lick papunta sa kabila. Ang lugar po kasi nang paglagyan namin nang septic tank ay mataas. Ididikit namin ang septic tank sa dingding nang kabilang bahay namin para pong magka level lang ang septic tank sa kabilang bahay namin? Pwd po ba yun? At ano po ba sir ang strategy po sa ganung bahay? Baka mag lick at mapunta ang tubig sa kabilang bahay mula sa septic tank? Ano po ang dapat gawin sir.? Maaari niyo po ba akong bigyan nang payo?.
@edwinalcantara2308
@edwinalcantara2308 4 года назад
Thanks sir,ask ko lang if pag hukay ay may tubig n lumabas bgo mag baywang ang hukay?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Pasipsip sa pump sir while constructing, water table na po kaya may tubig na, need din waterproofed ang septic vault
@edwinalcantara2308
@edwinalcantara2308 4 года назад
Thanks arki,hoping someday bgo ko mp repair uli haus ko ay kita kits for some details(magulo kc eh)ty edwin fr bacoor cavite
@sangivillaruz4487
@sangivillaruz4487 4 года назад
Hi po, iam a 5th year student po tanong ko lang po if how about po sa power house po may computation din po bayun?. Kung how much po na genset ung kailangan in a project po. This video is so helpfull din po 😊
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hi, sorry but Im not really familiar sa powerhouse load computation, i think you should ask for an Electrical Engr :) thanks!
@johnpaulmarcelino9076
@johnpaulmarcelino9076 3 года назад
Sir need po ba buhos ang flooring ng setic tank?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Yes po
@gddraftsman5617
@gddraftsman5617 2 года назад
#1.22
@1975blo
@1975blo 4 года назад
Sir more power sa vlog mo. Ang tanong ko po, kapag magpapagawa po ba ng septic tank, kailangan pa ba ng permit sa munisipyo to install septic tank?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Sanitary permit sir apply ka po ,need ng plumbing plans po
@samarayan35
@samarayan35 4 года назад
Sir, ung rebars po ng septic tank, kinocompute nyo din po ba?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hello , may standard spacing and grade ang rebars ng septic tank na sinusunod, pero pag masyado ng malaki you can consult a strctural.engineer :)
@remilopingol709
@remilopingol709 4 года назад
Can you make a vlog on Rain water Harvesting and Biodigester and how to incorporate them to our Plumbing Design?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Will consider :)
@ejlopena8088
@ejlopena8088 3 года назад
Good day po! paano po mag design ng septic tank for dormitory po?
@ejlopena8088
@ejlopena8088 3 года назад
additional question po hehe, kapag dormitory po yung project, are we still gonna use the "Liquid depth= minimum of .60 - 1.80" and "Width= minimum of .90"?
@dhenziorolpu9026
@dhenziorolpu9026 4 года назад
Boss pwd bang magtayo ng CR sa ibabaw ng septic tank?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
If the code will rule hindi po pwede, sa open space po dapat :)
@dhenziorolpu9026
@dhenziorolpu9026 4 года назад
Raw House PH ano po kayang magiging problema pag sa ibabaw
@ClickMeTV15
@ClickMeTV15 4 года назад
sir ask ko lng po..pwede po ba wla manhole yung septic tank..plumber po kasi sabi kasi foreman namin kht wla ndaw.at old design daw un..ok lng po ba yun?
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Hehe hindi po pwede, itll be an access for maintenance
@ClickMeTV15
@ClickMeTV15 4 года назад
ok lng daw po kasi meron dw po tubo n nkalabas at wla nmn dw po npasok sa posonegro samin..kaya ok lng daw po
@Rawhousearchitects
@Rawhousearchitects 4 года назад
It isnt, as a professional i suggest have a manhole, but its up to you sir. Sa sanitary compliance bagsak yan if legally done po
@ClickMeTV15
@ClickMeTV15 4 года назад
yun nga po sir..mas gusto ko tlga may manhole kaso natapos na nila kya wla n po ako mgwa..ang cnsabi ksi dw dun pdw s manhole nagccmula sumingaw
@ClickMeTV15
@ClickMeTV15 4 года назад
sige po sir slmat s advice..
@tagalogforadultlearners
@tagalogforadultlearners 3 года назад
Pwede ba tayuan ng bahay ang ibabaw ng septik tank?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Hindi po
@hbentz8110
@hbentz8110 3 года назад
@@Rawhousearchitects pwede ba ilagay ang septic tank under garage?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Yes po
@introvertedsapiophile5255
@introvertedsapiophile5255 4 года назад
Gawin mo 2/3+1/3+1/3. Mag lagay ka ng allowance. Yes di na advisable yung 2 chamber as per doh. And rncp need to be revised for almost 3 decades na yan di oa nagagalaw.
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Yes sir, so I advice mag add ng 1/3 additional if 3 chambers ang required :) as just stated as per the code po
@christinebacud5262
@christinebacud5262 3 года назад
paano po nalalaman ung size ng manhole ?
@Rawhousearchitects
@Rawhousearchitects 3 года назад
Nasa code po
@ryanriovaldez3185
@ryanriovaldez3185 4 года назад
Revised family code yata pagkakarinig ko sa 1:28 😁
@Rawhousearchitects
@Rawhousearchitects 4 года назад
🙈
@nav12G
@nav12G 3 года назад
Im an architect alam natin yan..pero sa ENRO lalo na dito sa dumaguete iba.. eh dapat nakasUnod ka sa kanilang dimension.. minsan aabot panang 8.00 meters yong vault mismo..
@Rawhousearchitects
@Rawhousearchitects 3 года назад
yup sir, local ordinances always governs naman , rnpc is referral lang
@rolgom
@rolgom 4 года назад
Your style is more like hosting, but should you consider showing most of your visuals? That way, your audience will be much more enlightened with what you are trying to explain. Thanks but no offense, I find it hard to understand your way of showing into pictures the things that you want to explain. Sorry, it’s just my suggestion.
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Appreciate it man =)
@caliphzsuhaide4850
@caliphzsuhaide4850 3 года назад
@@Rawhousearchitects Yes. Hndi po klaro visuals sir, but thanks.
@davidbuhay8380
@davidbuhay8380 4 года назад
Sir, napansin ko lang po yun sabi nyo sa ( "....the depth of a septic tank has a minimum value of .6 M to 1.8 M.. for liquid depth chamber......." (Time slider : 3:00/6:59 Minutes) Ibig nyo po ba sabihin is allowable depth range yan na from .6 M- 1.8 M or can say from minimum .6 M to maximum 1.8m po? If so, hindi na po ba pwede umabot ng let say 2M ?,, Salamat po Sir (davidbuhay@yahoo.com)
@Rawhousearchitects
@Rawhousearchitects 4 года назад
yes as per NPCP
@Rawhousearchitects
@Rawhousearchitects 4 года назад
1.8m max , pag mas mataas pa dun, aerobic and anaerobic bacteria cant process throughly :)
@emeritalelis9392
@emeritalelis9392 4 года назад
relate ako copy paste 😅😅😅😅
@Rawhousearchitects
@Rawhousearchitects 4 года назад
pinagbabawal na teknik
@emeritalelis9392
@emeritalelis9392 4 года назад
hi..but it was during my college days..😁😁
@rainsselsadie5564
@rainsselsadie5564 4 года назад
Thank you sir ! Keep posting!
@Rawhousearchitects
@Rawhousearchitects 4 года назад
Youre welcome! 🥂
Далее
Septic System Install | Complete Cost Breakdown
20:05
How Does A 3 Chamber Septic Tank Work
8:04
Просмотров 490 тыс.
iPhone 16 для НИЩЕБРОДОВ!
00:51
Просмотров 811 тыс.
PAANO MAG DESIGN NG SEPTIC TANK AT MAGKANO?
22:51
Просмотров 1,1 млн
Ace+ Review Center | How to Design a Septic Tank?
38:12
what size septic tank
6:38
Просмотров 13 тыс.
How To Calculate Septic Tank Drain Field Size
11:20
Просмотров 56 тыс.
Septic Tank Sizing using Excel (Tagalog)
31:28
iPhone 16 для НИЩЕБРОДОВ!
00:51
Просмотров 811 тыс.