How To Install a 3 Wire 521 Hard Start Kit 

Word of Advice TV
Подписаться 550 тыс.
Просмотров 205 тыс.
50% 1

How to install a 3 wire 521 hard start kit. Start capacitor with a separate potential relay. In this video I explain why the 521 3 wire kit is better than the 2 wire kit and then I show an example of how to install one.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
➡️ Various Hard Start Kit Options and Sizes:
SPP6 Hard Start Kit: amzn.to/2JSPieo
Supco with Electronic Potential Relay: amzn.to/3fK42bc
Supco with Mechanical Potential Relay: amzn.to/3emGnx0
5-2-1 Compressor Saver (1-3 ton units): amzn.to/2YivQym
5-2-1 Compressor Saver (3.5-5 ton units): amzn.to/2YbopVo
Rectorseal Kickstart (1-3 ton units): amzn.to/2XYwH7H
Rectorseal Kickstart (3.5-5 ton units): amzn.to/32KgZvS
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
For More Repair Videos:
🔍 How to Read Refrigerant Gauges:
• How to Check AC Freon ...
🔋 Capacitor Playlist:
• Capacitor Playlist
🔥 Furnace Repair Playlist:
• Furnace Playlist
❄️ AC Repair Playlist:
• Air Conditioner Playlist
💧 Water Heater Playlist:
• Water Heater Playlist
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🛒 For a Complete List of Tools and Parts Visit my Amazon Page:
amzn.to/2Q3QTOA
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🅿️ Want to Support This Channel? You can donate via PayPal:
www.paypal.com...
👨‍💻 Or if You Believe Crypto is the Future:
Bitcoin: 3Lor4QqqExtScgkuHkNffJJksVXM5cq1mM
Ethereum: 0xb981484980b36d5d1b5d6574f3c5bfd73c19e13f
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🛒 Parts mentioned in my AC videos:
1 Pole 30 Amp Contactor: amzn.to/2tdICNB
2 Pole 30 Amp Contactor: amzn.to/2JWlI7Z
SPP6 Hard Start Kit: amzn.to/2JSPieo
30+5 MFD Capacitor: amzn.to/2M4M83O
35+5 MFD Capacitor: amzn.to/2JXTVUs
40+5 MFD Capacitor: amzn.to/2yrugyr
45+5 MFD Capacitor: amzn.to/2MG8ZDY
50+5 MFD Capacitor: amzn.to/2M7RFGY
Qwiklug Compressor Wire Repair Kit: amzn.to/2JWmsdh
3 Amp Fuses: amzn.to/2JViUYO
1/4 HP Blower Motor: amzn.to/2tfifXT
1/3 HP Blower Motor: amzn.to/2K63HQL
1/2 HP Blower Motor: amzn.to/2trGVeM
3/4 HP Blower Motor: amzn.to/2tqsKGX
FM55 Blower Motor Bracket: amzn.to/2MbdYeK
5 MFD Capacitor: amzn.to/2K5NcHn
10 MFD Capacitor: amzn.to/2tqP7ft
15 MFD Capacitor: amzn.to/2MJZzHU
30 Amp Disconnect Fuses: amzn.to/2JYcSGH
25 Amp Disconnect Fuses: amzn.to/2tgcJUC
20 Amp Disconnect Fuses: amzn.to/2tcEFsM
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🛠️ For those who are interested, tools that I have/use in my videos:
Malco Flip Bit 1/4" to 5/16": amzn.to/3hNtj65
The Best Flashlight: amzn.to/2DLCYFx
UEI Multi Meter: amzn.to/2MbSHC2
The Best Drill: amzn.to/2MHLudO
Magnetic Drill Bit Set: amzn.to/2ML0esn
Motor Hub Puller: amzn.to/2LDntqx
Amprobe Psychrometer: amzn.to/2K54Nvi
UEI Dual Manometer: amzn.to/2NGmD9Q
Multi Tool Wire Stripper: amzn.to/2Karthq
Magnetic Nut Drivers: amzn.to/2tdEdKz
Knipex Cobra Pliers: amzn.to/2tg4Rm2
2 Piece Crescent Wrench Set: amzn.to/2A7aM2W
14 Inch Pipe Wrench: amzn.to/2JP30tY
Magnetic Tray: amzn.to/2Mc4Fv5
Screw Drivers: amzn.to/2JUaGjw
Stubby Magnetic Nut Drivers: amzn.to/2NHDolh
Flexible Drill Bit Holder: amzn.to/2K4dgiO
Long Drill Bit Extension: amzn.to/2JLCvFH
Angled Drill Bit Holder: amzn.to/2Mbqc7r
Drill Bit Extensions: amzn.to/2MbcbGC
UEI Temp Probe: amzn.to/2K3E1UE
Zoom Spout Oiler: amzn.to/2tctO1E
Hex Key Set: amzn.to/2lp2bhO
DeWalt Drill Set: amzn.to/2M940up
Wire Connectors Set: amzn.to/2tqYn30
Wire Nut Set: amzn.to/2tdgF8I
Voltage Pen: amzn.to/2tq5t8d
Pocket Extendable Mirror: amzn.to/2ytJzXr
Magnetic Jumpers: amzn.to/2L1wPZN
Mini Alligator Jumpers: amzn.to/2N067S1
ECM Service Tool: amzn.to/2p0rA3h
Klein Step Drill Bit #15: amzn.to/2ObgdjV
Color Coded Snippers 3pc: amzn.to/2Nz6rLk
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🙏 We would greatly appreciate it if you considered supporting our channel while shopping on Amazon by buying anything you need on Amazon after clicking on one of the links above. This gives us a small commission at no additional cost to you and helps us continue producing more videos! Thanks a million for your support!!
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
This video is for educational purposes. All appliance and HVAC repair work should be done by a trained professional. Word of Advice TV is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
📥 SPONSORS / Collabs:
Would you like to partner with Word of Advice TV? 🤝
Email: WordofAdviceTV@gmail.com ✍️

Опубликовано:

 

27 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 287   
@WordofAdviceTV
@WordofAdviceTV Год назад
🔋 Capacitor Videos For Further Info: Original Video on Replacing a Capacitor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-C82HvbvP08E.html How to Replace a Capacitor Full Guide: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9ZGfvC-PMWU.html How to Order The CORRECT Capacitor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-mkqaOfvH4a4.html How to Check Capacitor With Multimeter: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-5_0nKm940nA.html How to Replace a Start Capacitor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-hC0nFT1XPcI.html How to Discharge a Capacitor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-45oZXnClMD0.html How to Combine Capacitors: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-qLJOWU33TFo.html What to do if Capacitor is Rusted: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-RSIi47uzApI.html How to Install SPP6 Hard Start Kit: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ThBsRFrdNiY.html How to Install 5-2-1 Hard Start Kit: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-KRQ3BzJPPn0.html How to Wire A/C Condenser Unit: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-KCanZEsLVEI.html
@vernroach3413
@vernroach3413 Год назад
For those that might still be confused, like I was when first starting, the #5 wire goes to common on the contactor, not the capacitor...1 to run, 2 to start, 5 to common...Thats potential relays...Again, that common, for #5 from the relay, goes ON THE CONTACTOR power out..I've seen people get this wrong, confusing common, but this video is clear and well done.
@PH-md8xp
@PH-md8xp Год назад
The circuit diagram that comes with the 521, makes the connection points crystal clear.
@vernroach3413
@vernroach3413 Год назад
@@PH-md8xp For most...Some people think a common wire or terminal is neutral...Of course these people shouldn't be dealing with electric in the first place, but they're out there...They even think a common terminal on a switch is for the common wire and that common wire, the neutral, not the power source...Yeah, Smoke that switch...Like I said, they're out there.
@tommywilliams8359
@tommywilliams8359 3 месяца назад
I watch hvac every night and you are my favorite. Thank you for helping us to learn. I ordered a 521 immediately and I will certainly enjoy hearing the compressor kick in the first time.
@DBNY23
@DBNY23 4 года назад
After watching your video, I installed a 521 3 wire kit that I bought probably almost two years ago but never got around to. Turns out when I opened the electric panel up there was already a Supco SPP7s installed. I pulled that out and put the 521 kit in and I went from loud starts and dimming lights to barely noticeable when the compressor kicks on. I replaced the capacitor at the same time after watching your capacitor video. Turns out neither were the root of my no AC problem as it was the float switch under the fan in my attic - which I determined after watching yet another of your videos. Fantastic resources - thank you!
@joemurcia3527
@joemurcia3527 7 месяцев назад
I've done a few of these but I always go back to this video before doing another kit just for a quick refresher.
@WordofAdviceTV
@WordofAdviceTV 7 месяцев назад
Glad to hear it's helpful! 🙂👍
@PH-md8xp
@PH-md8xp Год назад
If you have a clamp meter with an Inrush function, it’s possible to measure the current flowing into the compressor before and after the install of these hard start kits. There’s usually a significant difference and it’s just satisfying to know that the thing is helping your compressor do it’s thing.
@mikeyPRE6
@mikeyPRE6 29 дней назад
Yeah use your clamp on your meter to measure amp draw before and after .. usually cut in half .. pretty cool
@PorkGrinder71
@PorkGrinder71 5 месяцев назад
Nice job!! Many thanks. You earned a Sub from me!! As an educator for a trade school in Fl., and 71 years young, I see a great future for you once you reach a point of resisting the crawls and climbs! You’re a no BS kind of person making you very valuable !
@cmottepatriot
@cmottepatriot Год назад
Thanks my Man !! Used your video yesterday and installed a 521 Kit on our 1 year old, 4 Ton, 14 Seer split A/C system that was installed last July. Two things that I noticed after install was that system is a lot quiter on start up and the loud noise that the compressor used to make at the end of each cycle was a lot quiter too and almost non-existent !! Great video, keep up the Good Work !!
@alow2323
@alow2323 3 года назад
Thank you sir! Just installed a new run capacitor and a hard start about 45 min ago with the help of your videos. Salute sir
@robwill9129
@robwill9129 Год назад
Me too 🎉😊 Saved $600 contractor quoted me.
@bills6946
@bills6946 Год назад
On the capacitor, the 4 terminal stabs is common. The 3 terminal stab is Herm and the 2 terminal stab is Fan. Never any confusion
@troyfordguy1345
@troyfordguy1345 2 года назад
I installed one of these 5-2-1 Hard Start kits (CSRU2) just like in this video in a Goodman unit from 2016 and it let all the smoke out of the Hard Start Capacitor, looks like I may have a defective unit so I have another on order. Thanks for making this video, I was able to double check that it wasn't me that wired it wrong LOL!
@tripplewhipper
@tripplewhipper 3 года назад
A good analogy I've heard for potential relay wiring is "5-2-1 Can She Run" so 5 to Common, 2 to Start winding and 1 to Run winding
@IceSmash2
@IceSmash2 3 года назад
Yeah this video was great I'm used to wiring the two wire kickstarts. Thanks for the cool analogy as well.
@justice4all603
@justice4all603 3 года назад
I remember when you had to buy the components separate and make your own kit
@gabrielguerro8449
@gabrielguerro8449 2 года назад
Awesome
@skidork2777
@skidork2777 3 года назад
Great video. Only concerning part is the black wire. Telling us it connects to the opposite side where the power connects, with the other black wires is priceless
@Scott-hb8pu
@Scott-hb8pu 4 года назад
As someone new to the industry, you have the best and most informative videos on all of RU-vid. I love your channel and your teaching style, keep up the great videos!
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Thank you for such a high evaluation! I much appreciate it and will try to keep making more videos in a similar fashion!
@arkrainflood
@arkrainflood 3 года назад
excellent video, recommended it in an amazon hard start kit review. dont know if it helps, but instead of just connecting the wire tabs, i sprayed contact cleaner on every tab of all the components, scrubbed with a toothbrush, then applied conductive carbon grease on the tabs to prevent future corrosion and improve electrical conductivity.
@Springerpop
@Springerpop 8 месяцев назад
Hadn't thought about conductive grease, or even dilectric grease, but it SURE couldn't hurt! Good idea!
@richardgarcia6108
@richardgarcia6108 4 года назад
As. Handyman I have been following your channel for quite a while. I really learn plenty. I did this upgrade to my AC system a couple of years ago as I discovered that the inrush amp draw was nearing the locked rotor amp limited listed on the the unit for the compressor. Prior to installing it the unit was struggling to start. You could hear the difference afterwards. It’s an amazing difference. It makes me wonder why AC manufacturers don’t include a “hard start kit” as a normal part of the units. Built in obsolescence perhaps...? Anyway, I enjoy your extremely clear, professionally prepared videos. Your an excellent teacher! I’m always looking forward to see more of your videos! Thank you very much!
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Thank you Richard! Glad to hear that my videos have been helpful and that the hard start made a big difference for your unit! As far as I know, many manufacturers actually did include a hard start capacitor and potential relay (basically a 521 kit) in older units. But to cut costs, this "un-necessary" part gradually started being omitted in newer units until now, when it's only the premium expensive units that still come with them. Well it actually kills two birds with one stone for them - the compressor does not last as long so people have to buy a new unit sooner and their production costs slightly decrease.
@reptilexcq2
@reptilexcq2 2 года назад
Thanks to this guy, I install the hard start kit and it work. But I also instead a new capacitor since it is completely dead. I manage to orient the 3 wire hard start kit in an upright position as indicated on the diagram and on this video...but it is so damm hard to drill a hole and it was hot outside. In the end, I just used tape and hope that it stick. I turn it on and wahla....everything running again. Even the fan is spinning. It wasn't spinning before. First time opening up the air conditioner, I noticed someone had installed a hard start kit compressor previously. So I ended up leaving it there and hooking up both start kits. This is my first time doing this fix and it is a life saver because I have no idea who to call for help. And it is summer and it's hot, I cannot stand the heat.
@czealtamahawk1228
@czealtamahawk1228 2 года назад
Am a new subscriber and fed up giving my $ away to HVAC co who's keeping me in the dark abt parts. Thanks for all your help. Much needed
@Nostradamus_Order33
@Nostradamus_Order33 3 года назад
I had disconnected orange number 5 and was not 100 certain where it went. Thanks this helped me.
@ac777
@ac777 Год назад
You are correct that the start capacitor should be installed with the terminals up. As per the instructions: "Mount the 5-2-1® Kit potential relay and start capacitor in a suitable location within the electrical box. The potential relay should be mounted with the mounting tab up. The capacitor should be mounted with the terminals up." REASON: Most Capacitors are oil filled and could be subject to leakage therefore it is always recommended to minimize the chance of leakage
@ip5232
@ip5232 2 года назад
Sir, I wish everyone would take as little and very efficient, and safe way to wire this , you took the right word and time to do this and a very understandable way! Thank you!!
@cyrilasfrenchyaz
@cyrilasfrenchyaz 4 года назад
Great video as usual, clear and well done! I've seen a lot of videos in order to install a solid state contactor like White Roger or Emmerson but they are always missing key components. Maybe it's time to upgrade your AC contactor and make a video of it? Keep the good job!
@andreeriner811
@andreeriner811 7 месяцев назад
Good vidio Jake. Just a word of advice bud, I wear copper fit fingerless gloves now. I didn’t think about it to much when I was younger, but you, a I use our hands a lot doing this kind of work. I think they reallly help me. Probably kept me from getting a shock a time or to also. Anyway, free advice my friend. God bless.
@benp7164
@benp7164 2 года назад
A very useful and great video. I just want to know the differents between a Hard Start Kit and a Soft Start Kit. Thank you. for your effort
@jessec.9295
@jessec.9295 Год назад
Man this guy gives you great tips .much apreciated
@fengtaowang5348
@fengtaowang5348 4 года назад
Five Two One : Can She Run? (Common Start Run)
@willford8302
@willford8302 3 года назад
Hahahaha lol
@jericosha2842
@jericosha2842 2 года назад
This is what I needed. Love you BB
@paulmartin3482
@paulmartin3482 2 года назад
Easy way to remember
@curthauburg9174
@curthauburg9174 4 года назад
Martin these videos are very helpful, also wanted to learn about trailer ac units and installing mini split in one.
@WordofAdviceTV
@WordofAdviceTV 4 года назад
If I get an opportunity to do a job like that, I will try to film it. Thank you!
@waverleywestwingman9886
@waverleywestwingman9886 3 года назад
Saved me thousands! Thanks, bro!
@carlostejada4137
@carlostejada4137 3 года назад
Last thing u shared (get rid of theapp adds) was nice, the rabbit too😅👌👌
@littlefishinggoat5409
@littlefishinggoat5409 3 года назад
He made the video, he deserves the add revenue. ✌️
@indyoutdoors812
@indyoutdoors812 4 года назад
While I think your videos are more geared to the DIY viewers, they are awesome for new HVAC tech’s. Please, keep doing what you are doing. 👍
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Thank you Kelly!! I appreciate that! Channels like AC Service Tech and GrayFurnaceMan are more advanced and technical. I can't compete with them, those guys are smart and their experience years rival my age lol so I choose to focus on the DIY, handymen, and new techs audience instead. :)
@DreamLand20
@DreamLand20 2 года назад
Was very very useful. You made my life much easier. Thanks bro
@davidmckinney6577
@davidmckinney6577 4 года назад
Okay buddy 👍 I'm the first one Jay 👌... hope all is well with you and your family.. we are doing pretty good today me and Arnold and bigfoot... ol bigfoot is feeling much better than he has I'm very thankful for this...boy it's hot outside here and has been for the last few days.. you take care of yourself buddy and don't get to hot..I got to hot Thursday and I got nauseated and felt like throwing up and I had to get in the shade I was painting a hot tin roof.lol. I barely got off the roof before my legs went out..so you be careful working out in the heat..how are the chickens doing? My neighbor ol hen just hatched off 8 little chickens day before yesterday.. she came over here and layed some eggs and the black snake ate every egg and she moved her nest and layed some more eggs and started setting... they are black and white striped little doodler's...
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Haha way to be the first David! :) All is well over here! Planning to move soon. Very good to hear that Bigfoot is feeling much better and that all is well with you and Arnold too! It's not too hot in Minnesota lately so it sounds like you're the one who needs to use more caution out there :) Stay hydrated, wear a hat, and take breaks. I was painting the outside of my house in the sun last week though and I can understand a little.. It does get really hot! One of my chickens was killed by a weasel at night. I got out there before it could kill the others. I started closing their coop door for the night now. Oh dear, instead of weasels, there's snake problems over there.. I don't know what's worse.
@davidmckinney6577
@davidmckinney6577 4 года назад
@@WordofAdviceTV I hope all goes well with your moving that is a very stressful situation.. yes I have to watch the sun because we're I'm on high blood pressure medication it makes me very sensitive to the sun sometimes I skip it when I will be out working but it is still in my system.. yeah I wear a cap all the time I tell everyone it's my signature look.lol..i put it on straight in the morning and it will move to the right side and turn up a little just like people used to wear those felt hats back in the day.. that was a hobby of mine several years ago was collecting ol hats I have every kind ever made under the sun.. several top hats and the original box they came in.. I dress up the dogs sometimes...lol. Arnold like that captain hat I have like the skipper on Gilligans island... well I'm thankful for you doing well prayers pay off for sure and I pray you have a very smooth transition in 🙏 moving...god bless you and your family have a good night good buddy 👍
@deseremere
@deseremere 2 года назад
Lol, that condenser doesn't want 521, it wants some serious cleaning
@JohnFixes
@JohnFixes Год назад
The bunny made it perfect. LOL Yes I watched it all.. good job. Also thanks for the tip. Internet off!!! Why didn't I think of that?!?
@tubbed68cuda
@tubbed68cuda 3 года назад
Potential relay and a start cap over a thermistor type start assist all day every day!
@AskMrGreenthumbGardening
@AskMrGreenthumbGardening Год назад
The other thing I think you should have done is to fire the system up when done, so that all can see that it works.
@KevinP32270
@KevinP32270 Год назад
i did that with mine and his instructions were SPOT ON.
@MRM-wp4gr
@MRM-wp4gr 3 года назад
I sent an email to Suppco asking what temp their SPP6 cuts off, and if they should not be used in warmer climates that consistently get into the 110* range. Here is his exact reply, "The PTC relay drops from the circuit at about 160° or so. It can, and has been used in warmer environments."
@bills6946
@bills6946 Год назад
If you are a service tech, install the 5-2-1. The 2 wire might have you returning for a free service call to replace it
@espnocho7904
@espnocho7904 4 года назад
Great video would you recommend putting a 5-2-1 hard start on 2.5 ac scroll Compressor that doesn’t have one
@Norman-hd3uv
@Norman-hd3uv 3 года назад
Your videos are awesome and easy to understand. THank you? I installed this kit on my AC unit months ago, but I'm not sure if I did it correctly. Thanks to this video, I just learned that I have a single pole contactor, and I attached the black wire of the kit to one of the T1 terminals of the side that has constant line power. That's the side with the black wire coming in and thus why I chose it. Did I do that correctly? Or should the 5 wire been connected to the other side of the contactor that has the plunger? THANK YOU
@tommypitre5975
@tommypitre5975 2 года назад
well what was the answer
@jinkim1748
@jinkim1748 Год назад
Thanks. My AC cap failed but the cap in the 521 kept the system running. Cooling fan was turning in reverse, blow the hot air to ground, yellowing the grass around. The unit was hot, I believe the compressor were hot too. After watching your RU-vid, replaced the run capacitor. Fixed. Now I ordered an extra capacitor and I came with “CPT” port. That supposed prevent the compressor from running when the cap goes bad, rather than 521 cap over heating the system. Good idea. But I don’t know how to connect the 521 to CPT port. My best guess to connect the wire goes to C to CPT. ??? Thanks.
@Springerpop
@Springerpop 8 месяцев назад
Nope. Yellow wire goes to CPT.
@jinkim1748
@jinkim1748 8 месяцев назад
@@Springerpop Thanks. Then the CPT port is only made for the 521 connection, ??
@bills6946
@bills6946 Год назад
Some heat pumps have a terminal on the circuit board specifically for the black wire. If you have a heat pump, look at the schematic on the cover. It will usually show the hard start wiring with dotted lines. Follow that schematic or the unit may not start.
@tomtim2111
@tomtim2111 2 года назад
Great video as usual, thank you I will try it awesome
@TrueBeliever6491
@TrueBeliever6491 4 года назад
So many helpful ideas here! Thanks! God bless!!
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Glad to hear that! :) Thanks for leaving a comment, God bless you and family as well!
@michaelcostello6991
@michaelcostello6991 3 года назад
Nice demonstration
@frankamaral7594
@frankamaral7594 8 месяцев назад
Brother thanks for all your help would like to know if you could make video on how to retrofit or how to install a new ignition control module on a old gas package unit thanks again 🖐️
@robertstonebreaker8394
@robertstonebreaker8394 4 года назад
Looks like that bunny was trying to learn some HVAC knowledge he said forget it looks to dangerous LOL
@wanderingsoul2909
@wanderingsoul2909 Год назад
Hi, Thank You for showing how to connect the 3 Hard Start Kit wires to the dual run capacitor and the contactor. The instructions paper is NOT CLEAR on the red wire ( say to connect to the contactor ? ). Thanks :)
@NoorRefrigerationsystem
@NoorRefrigerationsystem 4 года назад
Nice video I love this channel
@lequang2296
@lequang2296 4 года назад
Great instructions Thank you - Like it
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Glad it was helpful!
@andylee3841
@andylee3841 2 года назад
Awesome as ALWAYS THANKS !
@drewsoutdoors2115
@drewsoutdoors2115 5 месяцев назад
Great video! Just a thought: maybe show people how to clean that dirty condenser, and talk about the consequences of a filthy condenser 😊
@TheWilferch
@TheWilferch Год назад
Nice info !!! ..... I get how it works.....but need to ask this---> the hard start kit includes a relay and a separate capacitor....that helps for that fraction of a second ( or so) during the starting-time....and then drops out immediately after.. What is the probability that the new capacitor or relay may become defective and it doesn't drop out? Seems it will damage the unit....quite a kick in the pants if doing this is to "improve" the life of your core equipment. So....how reliable are these new components and how often do we see these fail?
@imager09tube
@imager09tube 4 года назад
Excellent effort, thanks!
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Glad you enjoyed it! Thanks for watching and leaving a comment!
@timgoering3806
@timgoering3806 4 года назад
If you suspect a hard start is no longer working based on over 90% of LRA on startup, do you just test it same as a capacitor? Also see you have brush coil condenser. Can you make a video of best cleaning practices on those please??
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Yes, you would test it like a normal capacitor to check if it's bad or not. As for the spine fin coil, I normally just hose my unit down and that is sufficient. In fact I don't even spray it from inside out, just from the outside is enough. There is no need to get it super clean as long as you get most of the stuff off of it. I do show how I clean mine in my AC Maintenance video
@timgoering3806
@timgoering3806 4 года назад
@@WordofAdviceTV awesome, appreciate you brother. I will look it up! And Happy father's day!!
@Eddy63
@Eddy63 4 года назад
Great little vid Mr Word ... And kudos to your really great camera girl ... Lol ...
@OscarRodSeedsofG
@OscarRodSeedsofG 4 года назад
How do you know the camera person is a girl? Maybe because the interest in the bunny.
@WordofAdviceTV
@WordofAdviceTV 4 года назад
@Eddy Haha thank you! Glad you enjoyed the video and I'll pass on the kudos to my wife ;)
@WordofAdviceTV
@WordofAdviceTV 4 года назад
@Oscar Rodriguez I think I may have mentioned who my camera person is in my previous videos :) But she does like bunnies lol
@alvingallegos6367
@alvingallegos6367 25 дней назад
Installed my 5-2-1 hard start and did a white wire check and showed around 20amps with my clamp meter with no difference so I'll check it again but do recall connecting my yellow/green stripped wire to Hemp on the capacitor and the red to common to the capacitor as well. The black wire is to black terminal on contactor albeit I need to check whether it's on the input side or the output side. I'll update it if I notice any amp change.
@ArcolaBridge
@ArcolaBridge 2 месяца назад
Can I connect it to the hot side of the contactor instead of the switch side? The compressor uses less amps when it's connected directly to the hot side...
@emyf83
@emyf83 2 года назад
Great video!!! Thank you!👍
@vigorousboredom7016
@vigorousboredom7016 Месяц назад
What happens if the bleed resistor is not installed on the capacitor terminals? Would it burn up the capacitor or cause damage to the compressor?
@nicholastaylor1546
@nicholastaylor1546 Год назад
Thanks for the video - how do you tell is the hard start kit or capacitor goes bad and needs to be replaced?
@pipi7731
@pipi7731 Год назад
I'm a little confused. Does that 5 wire go to the contactor common or to the capacitor common. I watched the How to wire an AC unit and it showed it going to the common on the contactor. Here you show it going to the capacitor common. Or Does it matter as long as it goes to common.
@juancarlosbarrios8377
@juancarlosbarrios8377 2 года назад
Thank u so much, great video 👍😎
@leewarlic6983
@leewarlic6983 4 года назад
My Compressor recently burned out and was shorted to ground. Prior to that I noticed my main breaker box on the outdoor(compressor) breaker was buzzing intermittently about every 20-30 seconds when a/c, compressor were running, but never tripped the breaker. A/C was also cooling fine. Fast foward about 1 year later and the compresssor shorted out and I had to replace it. Breaker is no longer buzzing while it runs but does have a quick buzz when compressor kicks on and lights slightly dim for a split second. My technician suggested installing a hard start. Is this likely the reason/remedy for the buzzing breaker? Or does that sound like an electrial issue that has nothing to do with the A/C unit? I will probably install a hard start anyways as it cant hurt it.
@Froggability
@Froggability 4 года назад
Yes when a unit is partially burnt out the amps could increase dimming your lights.. Suggest your next AC upgrade go for an inverter. No more dimming lights
@Austin-r7l
@Austin-r7l Год назад
Could this be an alternative fix to bad start relay if the OEM part is not readily available?
@WordofAdviceTV
@WordofAdviceTV 11 месяцев назад
Yes, I would replace the start relay and capacitor both with the 521 kit.
@papitosabe
@papitosabe Год назад
Isnt the capacitor in the unit a dual run capacitor? But ur going off the diagram/schematics for the one on the left (2 pole)
@kevinpoore5101
@kevinpoore5101 Год назад
thank you help me alots
@johndowns7536
@johndowns7536 Год назад
From a contractor: To have a hard start kit installed on your compressor, you can expect to pay anywhere from $300 to $350. Our prices always include the cost of labor and parts. The overall price of a hard start kit is cheaper than paying for a compressor replacement which can be $2,500 or even more. That's a $20 part, 10 minutes work.
@PH-md8xp
@PH-md8xp Год назад
We just had a quote from a local HVAC company to install a hard start kit for $439. Unbelievable.
@gerrywilson9162
@gerrywilson9162 2 года назад
Thank you
@marjunvlogger6690
@marjunvlogger6690 3 года назад
good day sir, can i ask sir, sir if i install hard start kit sir without potential relay sir, only the power pak only sir, possible sir working or not working?
@callmebackfriday2
@callmebackfriday2 4 года назад
I have an old A/C and about 30 years old and it has the original compressor. Is it too late for the hard start kit? Thanks for the video.
@WordofAdviceTV
@WordofAdviceTV 4 года назад
It's never too late if it is still working :) In fact, if what they claim is true, it will actually help your compressor survive a bit longer.
@callmebackfriday2
@callmebackfriday2 4 года назад
@@WordofAdviceTV Thanks for the information.
@lolocamacho3249
@lolocamacho3249 3 года назад
Hey thank you very much for all you could teach us doing all kind of work in the air condition my air condition is 3.5 tons and the cat and the relay is for the three tons only so that's going to work
@jesselopez2664
@jesselopez2664 2 года назад
What is difference between two pole capacitor and dual run capacitor instructions?
@utid1957
@utid1957 3 года назад
Great video. Thanks
@jonathanraul4086
@jonathanraul4086 4 года назад
Ty again nice video keep up the great work
@WordofAdviceTV
@WordofAdviceTV 4 года назад
Thank you Johnathan!
@yi-pinchang8333
@yi-pinchang8333 3 года назад
I just installed a 5-2-1 hard start kit following your video today! Thanks so much! I have a question for you. Would the AC still running fine if the kit is actually not working? I am asking because I have another AC which has the kit installed already. I suspect the kit is not working because when AC starts the lights blink.
@josecuevas7837
@josecuevas7837 4 года назад
Do you need a certain size for the hard start kits? Or are they universal like one size fits all. I've seen different sizes some bigger than others that's why I ask
@scoot77777
@scoot77777 Год назад
Very nicely done 🎉Thank you 🎉😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊😊
@brianmccafferty1470
@brianmccafferty1470 Год назад
Cute bunny!
@paulgettinger5983
@paulgettinger5983 Год назад
What do you think about the Micro-Air Easy Start for residential AC unit?
@domingoruiz2904
@domingoruiz2904 3 года назад
Thanks for very helpful info. 😏👍
@michaelminihan6430
@michaelminihan6430 9 месяцев назад
Blessings 🙌 ❤
@anthonyvalenzuela7489
@anthonyvalenzuela7489 3 года назад
Great video
@Darton-ok5xt
@Darton-ok5xt 2 месяца назад
after install original 5-2-1 hard start kit, seem the AC when turn on sound like it kick in louder harder than before, pls help why
@siahwia
@siahwia 2 года назад
What happens if you don’t place the potential relay with the arrow up?
@TheKarout12
@TheKarout12 2 года назад
how to test and when to know when I need to replace my Hard Start Kit or my capacitor a Video on that, please
@fungiuse
@fungiuse 3 года назад
When to replace it? My hard start is at least 15 yrs old, no problem yet, but should I replace it with a NEW ONE ???
@alecedwards9413
@alecedwards9413 3 года назад
From what I’ve learned it’s only supposed to be a temporary fix and to replace it ASAP. I’m still a student tho so lol
@gfbemc0256
@gfbemc0256 Год назад
What was the In-rush current with the Supco booster kit? What was the in-rush current with the 5-2-1 booster kit? Have you tried the 5-2-1 CSRU3 Heavy Duty start kit?
@gee_zus8226
@gee_zus8226 Год назад
I May sound dumb but how would you wired that 5-2-1 to a capacitor that has the CPT terminal?
@JLV-l4c
@JLV-l4c Год назад
Hi buddy how are you I hope you are doing well and thank you so much for all those videos that really helps and I have a quick question do you have any update on the new refrigerant gases that we use on AC?
@julianmolina673
@julianmolina673 2 года назад
Just installed a 521 on my Concord Condensor after compressor stopped working. It is now making a really loud rattling noise but is cooling. Any ideas what the issue could be?
@tonyspamony8018
@tonyspamony8018 4 года назад
Installed a 521 hard start kit this weekend following your instructions on my 15 year old 4 ton R22 system. It started up and ran fine for 5 hours. Then the AC stopped working. When I opened the electrical bay of the condenser the hard start capacitor had blown its top completely off and had covered everything in melted plastic. Some of the wires were melted. I removed the hard start kit and spliced in new wires to the compressor, compressor fan, and run capacitor and now the AC is back up and running. Any idea as to why the 521 hard start kit failed? Could it be just a defective kit? I would send you a picture if I knew how to attach it.
@vinhpham8363
@vinhpham8363 4 года назад
The potential relay didn't -energize and the N.C contact did not open to cut off the power for the start capacitor, after the time it is exploded.
@hpman2391
@hpman2391 2 года назад
I would use an easy start much better, just my opinion I've used kick starts, when old ac was struggling to start compressor🤔
@emailjlira
@emailjlira 4 года назад
Fyi You had stated that it didn't make a difference which way the hard start capacitor was seated, only the relay. I noticed in the instructions that the hard start capacitor should be placed in the upright position even though it can slip down if not tight. I was told there is some gel in there so it is best seated in the upright position. Anyone else can chime in to clarify!
@johns4870
@johns4870 2 года назад
My trane has a smaller cap on the fan motor in addition to the standard cap. Should i remove the smaller cap before I install the hard start 3 wire? It's a titan motor run capacitor.
@noeljbosco
@noeljbosco 2 года назад
Love your videos! You saved me a ton of $$$. On connecting the common to the contactor, I've read multiple opinions on which side to mount the black wire. Some say the shunt side, you said the opposite side of the incoming wires. Maybe the same thing? How can I tell on a Lennox hs29-048?
@rogerbeaird3320
@rogerbeaird3320 2 года назад
thank you for your advice ihave an amana entrance they said that my compressor stat capacitor was bad andvits 20 plus years everything else checked out grea but they don't make my part anymore can I use this 521 like u did sir please let me know it's just now April 10 2022 can you let me know please
@nextlayersecurity
@nextlayersecurity 3 года назад
Great video. I just installed the CSRU2 5-2-1 kit and 99.9% sure it's correct. A/C still working. How can I tell if it's working correctly?
@KevinP32270
@KevinP32270 Год назад
thanks.
@sh2697
@sh2697 3 года назад
i bought a spp6. It is for a compressor using a 50 micrfarad. Do you think this would be ok?
@asadandrew
@asadandrew Год назад
I have a Lennox 2 stage 1 seer 5 ton unit, the lights dim when it fires on, do I need a hard start kit? Can I even put one in on a 2 stage unit ?
@ibrhassan
@ibrhassan 3 года назад
Great video as usual, My 25 yeas old Rheem AC has a blank label, How can I tell if I need the 1-3 or 3-5 kit? I hope you can help
@fordrac1ng81
@fordrac1ng81 3 года назад
Look at the specs of the capacitor.
Далее
Installing a 5-2-1 Hardstart
12:06
Просмотров 229 тыс.
Самая сложная маска…
00:32
Просмотров 1,2 млн
Capacitor and Hard Start Myths Busted
28:41
Просмотров 248 тыс.
Troubleshooting the HVAC Potential Relay!
4:25
Просмотров 105 тыс.
How to Replace a Contactor in AC Unit
21:53
Просмотров 222 тыс.