Тёмный

How to install a bypass between the heat pump and a swimming pool? 

Bosta UK Ltd
Подписаться 156
Просмотров 18 тыс.
50% 1

How to install a bypass between the heat pump and a swimming pool?

Опубликовано:

 

11 сен 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 8   
@SouthYorkshireTTRescue
@SouthYorkshireTTRescue Год назад
well watching the video and adding it to our pond seems to have done the trick we will keep a eye on it over night and give a update tomorrow thanks 11.5 inlet and 13 out so far ideal temp is 26c
@dimitrigoossens9082
@dimitrigoossens9082 2 года назад
Thanks for the video! Can you tell me where i van view the temperature of 35 degrees?
@dennisskinner2339
@dennisskinner2339 4 года назад
tasmedic, how would you have plumbed it?
@williamhiman8017
@williamhiman8017 14 дней назад
Why not a 3 way diverter and one ball valve? Save 50%
@sergioamescua6264
@sergioamescua6264 2 года назад
Is it nessesary to install a bypass on a heat pump
@tasmedic
@tasmedic 4 года назад
Closing valve 3 to set up the flow through the heat pump is not a good idea for various reasons: It makes the water supply pump work harder by increasing the resistance it's working against. This could also invalidate the water pump warranty, and of course the more valve 3 is closed, the more current the water pump will draw, and the more expensive it will be to run. Closing valve 3 will also reduce the action of the filter which is in series with the heat pump in your diagram. Better to use valve 1 to control the flow. Opening that reduces the work the water pump has to do, and also reduces water pressure within the heat pump itself, which causes associated components within the heat pump less stress. Closing valve 3 increases the water pressure within the heat pump itself, which is not good for long term reliability of the circulating water system within the heat pump. Also, I get the impression that much of the text in this video has been badly translated from a foreign language. A manometer measures pressure NOT temperature, and you can't use this term to describe both cases. A generic term which could be used would be "gauge". Better, however to use the terms pressure gauge and temperature gauge, to avoid confusion. The plural of video is video, is videos. Plurals have never needed an apostrophe before the "s". Other than these issues, a very helpful video. Any comments would be appreciated.
@davidrodriguez5804
@davidrodriguez5804 6 месяцев назад
correct, the only right way to control gpm is through the pump and only if your pump have variable rpm.
@andersemanuel
@andersemanuel 2 месяца назад
This must be the dumbest instruction video ever made. Absolutely everything is wrong. 20BAR!? 35degrees!? Reading temp on a manometer. Restricting water flow to the pool. Please make a new video that is checked by a technician. Silly silly people
Далее
Basenowa  Pompa Ciepła - Bypass
9:26
Просмотров 32 тыс.
Daltonik qiz (QVZ 2024)
00:53
Просмотров 166 тыс.
🎙ПОЮ твои ЛЮБИМЫЕ ПЕСНИ💥
3:10:10
Smart Sigma Kid #funny #sigma #memes
00:26
Просмотров 12 млн
Do I need a heater bypass?
2:38
Просмотров 22 тыс.
Bypassing a Gas Pool Heater
3:19
Просмотров 2,3 тыс.
bypass warmtepomp maken
8:13
Просмотров 3,4 тыс.
Poolklubbens Bypass skolan
30:20
Просмотров 8 тыс.
How to PRIME a Swimming Pool Pump | Very Informative!
12:50
Warmtepomp instellen met bypass
7:14
Просмотров 39 тыс.