Тёмный

How To Install a Pool Pump - Plumbing the Pump, Part 2 of 2 

Swimming Pool Tips, Reviews & How To - SPL
Подписаться 127 тыс.
Просмотров 490 тыс.
50% 1

WEBSITE: www.swimmingpoo...
In this video I will show you how to install a pool pump, specifically the plumbing of the pump. In part one I walk you through the wiring of the pool pump. To see that video: • How To Wire a Pool Pum...
This is a very difficult set up area as it is a small equipment pad and the area back there is nothing but dirt. A messy area to work in for sure. Plus the plumbing was done in such an unnecessary tight fashion. There was no need to put the equipment in such a tight fashion with such a large area back there - but "it is what it is."
So I was left with not much space at all unless I wanted to re-plumb the entire area and put in a new Jandy valve and backwash valve.
Here are the parts I used in this video in order as they appear:
2" Male Adapter for front of the pump - note it fits over a 2" PVC pipe
1.5" Fitting Adapter - this fits over an existing elbow or coupling
2" Self Align Slip Union - essential in getting this pump on
2" X 12" Nipple SCH80 Pipe - This resists heat - high melt temperatures
For the threaded parts I used Plasto Joint Stick but you can use Teflon Tape.
I like the Pool Heavy PVC Cement because it gives you more time to adjust the fittings which comes in handy in a tight spot like this here.
Any primer will do - it basically gets the pipe ready for the Cement
Recap:
There is really no way in this type of tight area to jam two opposite ends on PVC pipe up to connect the pump so a Union was needed on at least one part of the piping. I would like to have put one in front also but the installer left me zero room to do so. So with one union it was still pretty difficult to squeeze the pump in - as you can see from the video.
In a real world installation you will find that most of the pool equipment installed is in a tight configuration like in this video. Especially a lot of the older equipment installs. The one foot manufacturer rule for a straight pipe from the elbow in the intake of the pump is not really followed by most original installers so I have to live with it.
Mrdgvb1 Social Media Links:
Google +: plus.google.co...
Blogger: poolmandave.blo...
Facebook: www.facebook.c...
WEBSITE: www.swimmingpoo...

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 163   
@erins.5420
@erins.5420 2 года назад
God love you for this. I don’t have a handy man around to do work like this around my home but I am able to take care of most things with very clear and directive videos like this one. Thank you for sharing your knowledge so I can save some money and do the work myself. It looks good and is a quality repair thanks to your instruction and I must say it feels good too knowing I could do it myself.
@drdrew3
@drdrew3 2 года назад
Most every pump installation manual calls fora minimum of 10” straight pipe on inlet side to minimize turbulent flow and cavitation. Pump will run with less strain and cooler temp thereby extending its life
@SPL
@SPL 2 года назад
Super rare to see 10" of straight pipe in front in any CA install. The equipment pads are so tight.
@shane7133
@shane7133 2 года назад
Why wouldn't you just use a high temp union on the suction and discharge of the pump?
@triggertime90
@triggertime90 3 года назад
What made this a great instal is that it had to be done on such an old system, real world installation. One piece of advise, if the motor is stressing that union just shim it to relieve and pull the weight of the motor is putting on the piping. Great job considering what he had to work with.
@stanmiller2737
@stanmiller2737 6 лет назад
I wanted to thank you for a great video. I'm almost 70 and just installed / replaced my old 1 hp challenger. The union process you showed me saved my rear end!! I did the coupler on the front of the pump and the union on top. Worked perfectly, no leaks. Thanks again! Much appreciated!!!
@mima4392
@mima4392 2 года назад
If everything is glued how do you remove pump in the fall to bring the pump indoors. I had my pump piped in last yr. no leaks. This yr. I put it back together and leaks at the unions. What do I need to stop the leak?
@SPL
@SPL 2 года назад
Try putting in new o-rings at the unions.
@mima4392
@mima4392 2 года назад
@@SPL Thank you. I found the 3 0-rings in the pump.
@FactsMattersUSA
@FactsMattersUSA 4 года назад
Its actually off the ground, you'll need to shimmy something under pump or it will leak in the future
@JoseLopez-ep2mh
@JoseLopez-ep2mh 3 месяца назад
Hi David, two questions today. Is it possible for my Inteliflo 3hp VS pump to transition smoothly from one speed to another or does there have to be a one minute gap, 1900-2700 for example. The second question is, is it possibly to remove phosphates easily. With the poolrx I wasn’t too concerned about them but I think even the poolrx is reaching its limit. 1300 phosphates as always thanks for all you do.
@SPL
@SPL 10 лет назад
How To Install a Pool Pump: Ever wonder how to attach two pipes that seem impossible to connect? Here I show you how to install a pool pump properly and easily.
@tommyflyer5115
@tommyflyer5115 4 года назад
Great video! I can tell you there are two others method you can use instead of a union. One method is cut at the top and add a elbow. Second method is you can use 2 inch pvc slip and burr out the inside center and pull it up after you gave apply the glue on both end. 😉
@jackcassidy9403
@jackcassidy9403 8 лет назад
Hello. Thanks for your videos! I disagree with the below post that "you are using too much glue". Nothing like cutting back on the glue and fitting it all up, only to discover a drip or leak and have to start all over again! I have two in-gound pools in two homes and your videos are extremely helpful, even though I am an Engineer. Questions: I am installing a new Pentair Multi Speed and feel I should install a check valve in line while the system is down and all tools are available. I believe I have two issues, which may require two check valves. (1.) Should there be a check valve on the pipe the pump suction prior to the pump to prevent water from retreating to the pool, now causing the pump to take 30-60 seconds to prime on each start up? (2.) Should there be a check valve on the pipe prior to entering the Pentair tablet chlorinator to perevent high chlorine content H20 from backing up into the equipment? (3.) Unrelated to the above, I installed a Pentair Chlorinator 320 and found that the tablets are not being consumed, causing me to manually add chlorine to the pool. My theory is that the supply line PSI feeding the 320 is very close to the PSI of the pipe the chlorine should be exiting to, thus causing it to remain static. I added a tablet, filled container with water then capped it and tablet remains whole after 2 days. Any suggestions? (4). Lastly, this same pool has a raised spa with a waterfall into the pool. When the pump shuts down, several hours later the spa water seeks the level of the pool. Would a check valve above #2 remedy this issue? Thanks for any assistance you may offer. Jack C
@SPL
@SPL 8 лет назад
If the spa is elevated above the pool water line there should be a bypass check valve installed to prevent water draining back into pool. Generally the check valve for the spa goes on the pipe where the bypass is - usually an elevated spa has water running to it even when pool is in "pool mode." Would have to see you equipment layout to further advise. Check the bottom screen in the 320 to make sure it is not clogged up. Use a pair a tongs to remove it and inspect it. And yes, a check valve in front of the pumpcomes in handy for what you described. And they sell a specific check valve for the 320 chlorinator with no metal in it: Rainbow R172288 Corrosion Resistant 1.5 x 2 inch Chlorinator Check Valve
@lovera3878
@lovera3878 3 года назад
I am redoing my pump because of an air leak and this video is what I needed. Thank you
@raysarracino995
@raysarracino995 4 года назад
Dude, great video. Very helpful. I appreciate your narration of what you were doing step by step. Really nice work!
@havuzcumarket6610
@havuzcumarket6610 3 года назад
I wonder how you will disassemble this pump when it fails. It would be better if you put an easy-to-disassemble record on the suction side.
@sukriargoseto2525
@sukriargoseto2525 2 года назад
Minta tolong.. di ter jemahkan ke bahasa Indonesia.. terimakasih..
@cyrilasfrenchyaz
@cyrilasfrenchyaz 4 года назад
Why put only one union on the discharge? Couldn't you put another one on the suction? Would be easier to remove the pump if needed repairs? Just curious...
@SPL
@SPL 4 года назад
No room in this set up, but usually yes.
@chuckschillingvideos
@chuckschillingvideos 3 года назад
That final connection is always the worst. No slack whatsoever to make up for measurement/cutting errors or, worse, failure to fully seat the pipe into the socket.
@YOUandMeRealtyDotCom
@YOUandMeRealtyDotCom 3 года назад
“Fitting Extender” Goes Over Outside Of 1-1/2” Elbow? #LearnSomethingEveryday #GotFittingExtender?
@brandonrecker4582
@brandonrecker4582 2 года назад
Looks like a lot of cavitation in that pump...seems like air is getting sucked in the pump on the suction side
@SPL
@SPL 2 года назад
It was the old filter - that has been replaced as well.
@Ifugiveubegin2live
@Ifugiveubegin2live 2 года назад
That inlet is way to short.. whoever originally plumbed that didn't know what they' were doing
@cd-rom.
@cd-rom. 8 месяцев назад
Wouldn’t it be better to union both ends for easier removal for winter.
@SPL
@SPL 8 месяцев назад
For sure. But the original plumbing didn't allow for a 2nd union.
@WatsitTooyah
@WatsitTooyah Год назад
I can guarantee the length of that straight horizontal pipe going into the pump is not to spec.
@SPL
@SPL Год назад
Nowhere in CA is it to spec. 😆
@billwesolowski2609
@billwesolowski2609 6 лет назад
Where do you get your 1.5 and 2" extender fittings? I have looked at all big box stores and found nothing. Is there a proper name for the fitting where I can look it up online? Thanks
@SPL
@SPL 6 лет назад
SCP and PEP carry them. Here it is online: www.poolsupplyworld.com/Waterway-429-2010-PVC-Fitting-Extender-for-2in-Fitting/429-2010.htm
@sherio1980
@sherio1980 5 месяцев назад
thanks for this video. in the future if you want to reinstall another pump, how do you do that at the front now that you dont have any length of pipe left?
@keithlavender7951
@keithlavender7951 3 года назад
Thank you!
@kellyvb9881
@kellyvb9881 3 года назад
I would have re configured to use a union at the inlet as well. Pain in the A they way you did it if you need to ever service the pump.
@justYouJesus1God
@justYouJesus1God 4 года назад
I have a question, my pump is not sucking up the water and rotating, the dial is at zero, could it be because there is leaking on the pvc pipes? I am a lady, I was watching your video, I don't think I can do this. How much would a pool guy resonalbly charge me for putting new pvc or fixing the leaks? The motor and pump are still working, just leaking at the connections.
@SPL
@SPL 4 года назад
$85 per hour plus a minor charge for the PVC pipes. Maybe 1 hour to 1/2 hours of labor.
@loisfaruolo6932
@loisfaruolo6932 3 года назад
I have a old 1 speed 3 hp 1996 challenger and the motor need replacement . Is it wise to buy a 2 speed motor to replace the one speed motor for energy saving when I just want to circulate my chemicals in the water???? BTW. I have an 8 jet spa and when valved off the spa has one separate jet that acts as a pool a overflow water fall while the pool is in valved for circulation and skimming. I also have a return separately valved for my polaris pressure side cleaner that i run as needed . In this 15000 gallon pool with a 10 person spa.
@SPL
@SPL 3 года назад
Would go with a VS pump. Either the Pentair Intelliflo or Hayward vs 950 - both are close to the 3 hp rating. Then you can set it to run at 1200 RPM as a low speed.
@MHrfffdssswqqwuuu
@MHrfffdssswqqwuuu 2 года назад
I have a 40-50k pool that has three return lines I had to plug one return line. Will that disrupt anything or cause low suction?
@SPL
@SPL 2 года назад
Should be okay
@unitedwestand5602
@unitedwestand5602 2 года назад
Wouldn’t it be easier to just replace the whole pipe from the pump outlet to filter with a union to the filter?
@SPL
@SPL 2 года назад
Would have to replace that jandy valve and cut the pipe down to the dirt. Not easier but it would make replacing the pump easier in the future.
@awengandaya6591
@awengandaya6591 2 года назад
Good day! What size of pipe is ideal for pool equipments such as motor pump and filter? Is 1.5 pipe okay? Thank you very much.
@SPL
@SPL 2 года назад
1.5" is fine in most cases, 2" is a little better
@ivanbunch1216
@ivanbunch1216 10 лет назад
OK I'm going to pump it in right away, I have to pipes coming out the ground ,I guess the one on the left side is the skimmer and the one on the right is the bottom drain .
@jefffrancis3377
@jefffrancis3377 7 лет назад
Ivan one way to detect which is which if not sure is to use some food coloring. This way you can tell for sure. little trick of the trade
@bludika
@bludika 2 года назад
do you HAVE to use schedule 80 pipe on the discharge side?
@SPL
@SPL 2 года назад
No, but it helps if pump runs hot at any time.
@quevenmz8456
@quevenmz8456 5 лет назад
Theres plenty of ways without using unions but everyone has their own style.
@marioarida8983
@marioarida8983 10 лет назад
Where do you get your Pool tite glue from? I cant find it anywhere in the Martinsburg WV or Winchester VA areas... I checked pool supply stores and plumbing supplies. Thanks for the video.
@SPL
@SPL 10 лет назад
Any brand of PVC Cement will do as long as it is rated for high pressure. I guess they don't stock it in your neck of the woods.
@marcodejesus451
@marcodejesus451 4 года назад
Great video! Can you run 2 Pentair Variable Speed Pump? Filter and water fall feature? If yes, where do you connect the green and yellow cable to the Aqua logic? Theres only 1 slot for green and yellow cables for 2 green and 2 yellow cables.
@SPL
@SPL 4 года назад
You can but it would be better if you used the Hayward Vs pump with their aqualogic system.
@ryanscottsholes
@ryanscottsholes 4 года назад
Could you use a union on both suction and discharge side so next pump replacement your not having to cut out pipe, if ever need to remove for service? I never see union on both sides? I’m very new looking at doing my first pump, filter install and not sure if I’m missing something as to why not to.
@SPL
@SPL 4 года назад
You should use them on both sides, but in this case there was no room.
@slvdrmnz
@slvdrmnz 2 года назад
why not use a union on both sides??
@SPL
@SPL 2 года назад
No room unless I cut that valve off in front. Usually, yes, 2 unions.
@MrBmxbrawler
@MrBmxbrawler 3 года назад
What happens when you have drips on the male adapter in front of the pump you just glued together with no union? Glue those male adapters into the pump
@SPL
@SPL 3 года назад
Gotta replace it at that point
@johnh9002
@johnh9002 8 лет назад
Are you using regular schedule 40? Also if my pump is 1 1/2 HP can I use schedule 40 under ground. I'm repiping the pool I'm unsure of what type of pipe would be best and. I'm worried about using 90's because of flow restrictions. I would use 45's but I don't want a lot of joints under ground. I could use a sweep as well but I want to really manage the flow. Right now there is black poly pipe with hose clamps keeping it together.
@SPL
@SPL 8 лет назад
Underground plumbing is not my specialty - I would call your local pool builder and ask for a consult - that way you get it 100% right.
@marcodejesus451
@marcodejesus451 4 года назад
Just wondering...why SCH80 pipe? How how hot does it get over there?
@SPL
@SPL 4 года назад
If the pump runs dry due to low water it can get very hot and melt the plumbing around the threads. Sched 80 prevents that.
@dmtycn
@dmtycn 6 лет назад
Is there any cement to replace weld-on 746? Want to install an inline chlorine dispenser but don't know which cement to use in homedepot or lowes. Is Oatey Heavy Duty Gray PVC Cement OK?
@SPL
@SPL 6 лет назад
Yes, that is a good brand also and a good choice of cement.
@jacobbuddy2827
@jacobbuddy2827 4 года назад
If you are swapping the same pump for the same model again would I need to do any additional plumbing works, asking as an electrician
@SPL
@SPL 4 года назад
No. Every should line up exactly the same - especially if there are unions in front and on top.
@metalexfuentes2611
@metalexfuentes2611 2 года назад
It's ok to not use Teflon!?😳
@SPL
@SPL 2 года назад
Any threaded part except unions with orings needs the teflon
@BigJeff19999
@BigJeff19999 10 лет назад
I had a couple of questions on that joint stick ... I recently tried to plumb my above ground pool filter between my new pump and old cartridge filter. Right at the spot where the threaded pipe screws into the the outlet is where my leak is ... I used teflon tape on the threads ... is that joint lock stuff better than teflon tape? Does it glue the fitting in? Should I be using an 0-ring? Thanks for any help. Jeff
@SPL
@SPL 10 лет назад
Teflon tape is comparable to the joint stick - pool guys will use both. The joint stick never really dries so it doesn't glue the pipe to the fitting at all. Nothing goes between the threaded fitting and the pipe - so no O-ring.
@legendiver
@legendiver 9 лет назад
Should you sink your threaded pipe fittings all the way? I did not and have a vac. leak that won't allow a prime. I don't see water or air coming from the threaded areas and did use teflon tape. Day 4 of the challenge! I may have to do corrective surgery.
@SPL
@SPL 9 лет назад
Legen Diver I thread the in as far as they will go. You might have to cut the pipe and re-thread them in. It happens.
@TheSAJKW
@TheSAJKW 2 года назад
Can you use the unions for both connectors to help avoid the worry of the one shot and the last glue up going slightly wrong?
@SPL
@SPL 2 года назад
Yes. If you have the room 2 unions are best.
@THAIWAK
@THAIWAK 3 года назад
Thanks for the video. Do you have to leave 24 hours as glue seems to set pretty fast? Stay Safe!
@SPL
@SPL 3 года назад
Out of habit I do. But some turn everything back on after 30-45 min
@mitchellvanburen9980
@mitchellvanburen9980 3 года назад
What would you do if you did come back to leaks? Would you have to start over?
@SPL
@SPL 3 года назад
Yes, you would cut the plumping and start over.
@fastman1574
@fastman1574 4 года назад
is it not necessary to fasten the pump to anchors such as Kwik Bolts ? You have the pump just sitting there .
@SPL
@SPL 4 года назад
No one bolts them down nowadays.
@guayabito6946
@guayabito6946 3 года назад
0:07 is it necessary to use the *POOLTITE* glue or can I use regular PVC pipe glue and primer? Pooltite is used for underwater conditions but if it is a new installation, why do you have to use it?
@SPL
@SPL 3 года назад
Any PVC cement will work.
@guayabito6946
@guayabito6946 3 года назад
@@SPL Thank you, that is what I thought.
@BillyBob-ng8mp
@BillyBob-ng8mp 4 года назад
Do we have to wait 24 hours before turning on the newly installed pump? Thanks for the wonderful video!
@SPL
@SPL 4 года назад
I do. Some will only wait an hour or so. I prefer 24 hours to make sure that the plumbing is bullet proof.
@michaelmendoza6497
@michaelmendoza6497 5 лет назад
Can you use regular pvc from lowe's? Pool and jacuzzi.
@SPL
@SPL 5 лет назад
Yes, they sell standard schedule 40 PVC
@brianonthego
@brianonthego 5 лет назад
Great work
@johnwoolfrey5093
@johnwoolfrey5093 10 лет назад
Nice Job. /John
@josemachuca3621
@josemachuca3621 5 лет назад
No experience in plumbing work but work
@CarlosMartinez-fv5kb
@CarlosMartinez-fv5kb 10 лет назад
Do you know how much conditioner I should use for a 45000 gal pool?
@SPL
@SPL 10 лет назад
According to: www.poolcalculator.com/ you will need 11 lbs to reach 30 ppm. That is quite a pool there.
@livingadreamlife1428
@livingadreamlife1428 4 года назад
I appreciate your attention to detail in this video. Easy to follow and understand also.
@TRUE_GR1T
@TRUE_GR1T 8 лет назад
lol waaaaay too much glue
@joeybusic4470
@joeybusic4470 10 лет назад
Long time lurker and big fan.. Your videos and reviews are awesome. So much valuable information.. I noticed you film with one hand and demonstrate with the other. Invest in a Go Pro Hero 3 with the head mount so you can use both your hands I strongly recommend .. also on your plumbing video.. I'm not sure if your familiar with the Praher 2" High temp Unions . They thread onto the pump housing and make removing the pump so much easier for future repairs. Also the weld on 740 Pool Regular Clear glue works great no primer needed .. Keep the videos coming! Thank you !!
@SPL
@SPL 10 лет назад
Thanks for the tips. I will look into all of them. Will be in the market soon for a new camera so thank you.
@grapplerguy2007
@grapplerguy2007 5 лет назад
cant use without primer on systems under pressure and isn't up to code , bad advice.
@mayac9388
@mayac9388 9 лет назад
Great video. I have to install the same pump with the same setup EXCEPT that the suction side at the valve has only a sliver of pvc pipe which would not allow the same connection as in the video. Any suggestions would be much appreciated.
@SPL
@SPL 9 лет назад
+Maya C Maybe send a photo to my website and I will take a look.
@snookcandy2330
@snookcandy2330 8 лет назад
They have - 2" or 1/2" MALEXSOC HI-TEMP UNIONS that are already assembled for you, and all you have to do is plumb your pipe right in.They should have them at your local poolcorp distribution just to let you know 🙏🏽🌊
@SPL
@SPL 8 лет назад
Thanks for the tip.
@snookcandy2330
@snookcandy2330 8 лет назад
+Swimming Pool Tips, Reviews & How To -MrDgvb1 no problem thanks for the videos and good job 👍🏽
@josesoto4797
@josesoto4797 6 лет назад
joseph gonzalez
@jlcdrivewayramps7343
@jlcdrivewayramps7343 4 года назад
what is that white stuff on the thread....just good old silicon ?
@SPL
@SPL 4 года назад
More like Teflon Tape- Called a Joint Stick.
@jlcdrivewayramps7343
@jlcdrivewayramps7343 4 года назад
@@SPL thanks but why do you call it a tape ? Joint Stik is not a teflon tape.
@closequarters4575
@closequarters4575 4 года назад
That final step is always anxiety filled.
@lukeskywalker1674
@lukeskywalker1674 9 лет назад
i see a leak behind the pipe your cutting at 1:57.
@TRUE_GR1T
@TRUE_GR1T 8 лет назад
that's a dead bug or a piece of a leaf stuck to spider web
@catchmeifyoucan2815
@catchmeifyoucan2815 7 лет назад
Seems like an awfull lot of flow restriction. Two bends following each other directly, no length of pipe in front of intake, union following directly after a double corner ....
@SPL
@SPL 7 лет назад
I work with the hand I am dealt 😀 - it doesn't really matter until you get to 3" plumbing.
@frankwiddifield7520
@frankwiddifield7520 5 лет назад
Did you see the air in basket at end? I woulda cut that 2" coupling on intake 3port in half and put 2" fitting extender and just replumbed entire discharge to multi port with no need for a union.
@markrigneymd6570
@markrigneymd6570 4 года назад
Thank god it not just me. That looks like a home brew abortion with so much addition to the total Head just in the short part that was fixed. Also you may have noticed that the pump was actually hanging in mid-air from the out flow pipe. That won’t last long. I do not even want to tackle that remark about restriction issues not being important till 3” pipe???????
@gerryperry4081
@gerryperry4081 4 года назад
how did you remove the old pump from the cement? We have something holding it in tight and don't know how to get the pump out
@SPL
@SPL 4 года назад
It's probably archor bolted to the cement. If the bolt heats are gone or not movable you will have to drill those bolts out.
@SPL
@SPL 4 года назад
anchor bolted.
@sashazxtt
@sashazxtt 5 лет назад
I was surprised not to see the pump being bolted to some concrete. Is it OK just to let the pump sit on a surface unattached? Thanks!
@SPL
@SPL 5 лет назад
Generally, no one bolts them down to a cement slab. Not unusual.
@sashazxtt
@sashazxtt 5 лет назад
@@SPL thanks a lot for the quick reply. Does the motor just sit supported by the inlet and outlet pipes? I thought there was enough torque and vibrations to warrant a former fitment. So I can just place a replacement pump on some concrete pavers? Makes my life easier 😁 Thanks again!
@frankwiddifield7520
@frankwiddifield7520 5 лет назад
Agreed, I've replaced more pumps than you can shake a stick at and only mounted 1 by customer request. And the pump is supported by the base and stays on ground due to gravity. 😎
@frankwiddifield7520
@frankwiddifield7520 5 лет назад
If there is that much vibration I'd take a look at restrictions in return plumbing ie dirty filter, clogged heater core, clogged solar lines.
@barronbarron1410
@barronbarron1410 5 лет назад
Anything special about that union? Certain type?
@SPL
@SPL 5 лет назад
Not really.
@frankwiddifield7520
@frankwiddifield7520 5 лет назад
Chemical resistant oring
@GalaXy808
@GalaXy808 9 лет назад
Very nice teacher,I wanna try too
@crackerjack4u
@crackerjack4u 6 лет назад
Awesome video. Thank you for making it. I have a few questions, and any suggestions would be appreciated. I'm disabled. I'm trying to do this via wheelchair, and am determined to do this myself, lol the swim season may be over by the time it gets done, but hopefully it will get done, and done somewhat correctly. I've just now starting my hard plumb using Sch 40 PVC on my above ground pool. I'm planning to run the lines from the skimmer/return to ground level for added support, and to, hopefully, increase the distance a little further between the pool and the pump. (I actually dry ran it originally with it just coming down from the skimmer, a short piece of PVC, the Ball Valve-cut off, another small piece of PVC, a 90 placed across from the pump, a short piece of PVC, the Union, a small piece of PVC, and the threaded/slip connector into the pump, but by the time everything was added in it just looked way too heavy to just be hanging there in the air, and having no support, so I decided to start over, and run it all the way to the ground, across, back up, and into the pump). I've done a little on it already, but with my physical limitations I'm only able to handle doing a little bit each day, plus with all the rain, rain, and lol more *&%$ rain, I've not gotten much done. (So far I've only put in the new thread/slip connection in the bottom of the skimmer, added a short piece of PVC, put in the 1st Slip Ball Valve below that, ran the PVC line to the ground, and put a 90 at ground level to start going across with). Here's a lot of my problem. I have very limited space between the pool and the pump, they are currently approximately only about 3 foot away from each other, (but I do plan to leave enough pipe available in the line to cut it and bury it next season, and move the pump to a different location about 5-6 more feet away from the pool. (The pump has been in this same location for about 5 years now while using just the regular hoses, and has done fine, I'm hoping the hard plumbing doesn't cause it to have flow issues by being so close.) Do you think this will cause a flow issue in regards to the PVC pipe, and the close location to each other? I'm placing Ball Valve-cut offs on the skimmer and return sides, and will also be T-ing a line off the return to make a DIY fountain with its own cut off. I also have Unions that I'll be using for easy disconnect. Where in the line should that Union be placed? Should it be closer to the pump, closer to the skimmer/return, or does it really matter? Do they do better if placed up and down, instead of laying across the ground part? Do Unions require any type of Teflon tape or sealer, or are they self sealing? At the pump, and at the return a threaded 90 would work better there and take up less space from having to add another connector in. Is there any issues with using a threaded 90 in those areas, or should a straight connector be used to prevent any additional possible pump flow issues, and then the 90 glued in after that? Also is it better to use (2)45s instead of a single 90? Also the clear line on the pump that has the metal in it (I think it's spa tubing possibly or something like that but I'm not sure). Is it alright to replace that clear tube with PVC as well or should the flexible clear tubing be left alone when hard plumbing the system? Ok Last question, lol I bet you're thinking thank goodness, it's about time lol: What type of white paint was used in the video to paint the pipe with, was it just regular white spray paint, or is there one specific for PVC pipe? LOL after just gluing together a couple of parts so far I can already tell it is definitely going to be needed? Sorry this ended up being so long. Thank you for any suggestions you can offer. Have a wonderful Night!!!
@retrovoltarcade
@retrovoltarcade 8 лет назад
Hey thanks for the tips - I followed your guide and it worked perfectly! Thanks again.
@microsoftwindowslover8346
@microsoftwindowslover8346 6 лет назад
More glue the merrier
@HappyJigg
@HappyJigg 10 лет назад
What do you do with old pumps?
@SPL
@SPL 10 лет назад
I usually will take it home and use it for spare parts. I've got a few on the side of my house. This one is still at the job site. I will leave them there in case the customer wants it for some reason. after a week or two I will take it home if it is still there.
@ivanbunch1216
@ivanbunch1216 10 лет назад
Is it OK to us the yellow cement glue its suppose to be for all wheat her ? Its a one step process or should I go buy the blue glue.
@SPL
@SPL 10 лет назад
It looks okay from what I just read online. Looked up the Oatey brand.
@ivanbunch1216
@ivanbunch1216 10 лет назад
thank, i just brought a house with an inground pool V,it didnt have a cover over the pool.leafs frogs and other creepy things where flying and jumping around inside the pool . i wanted to clean it out first before turning the pump on and then i shock it with 6 pk of 6in 1 treatment each pack covers 11000 gallons i think i have a 22,000 gallon pool ,the frogs started to jump out lol i'm thinking i might need more shock .
@SPL
@SPL 10 лет назад
Ivan Bunch Frogs re not a good sign... usually when you have organic life swimming in the pool it takes a boatload of chemicals. When I get to a pool and see swamp life, I generally bring the chlorine level up as high as possible. The green algae and organic life will sap away a lot of the chlorine as it is being used up fast. For 22,000 gallons I would dump in about 8 bottles of liquid chlorine and that will raise it up to 50 ppm - about 5 times the shock level of 10 ppm. That should be a good start. Got that number from: Thepoolcalculator.com. Follow the procedure here and it should turn around in a week: Green Pool Part 1 of 2, How to Clean: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ydIysBIHhWo.html
@ivanbunch1216
@ivanbunch1216 10 лет назад
i dont have my pump connected up yet is that ok for now , i thought i should get the leafs out first and ten i shock it with about 7 packs of shock 6 n1 but i will go and get some liquid chlorine, but i can add this now before i connect my hayward super .thanks
@SPL
@SPL 10 лет назад
Ivan Bunch I would get everything connected and up and running. The pool won't clear up well if it is not circulating. So plumb in the pump and get everything going as soon as possible. That is my recommendation.
@fangorn1000
@fangorn1000 9 лет назад
yes. good Job. You made it easy on me.Thank you
@bobbychavez5637
@bobbychavez5637 5 лет назад
Great job good to see someone take pride in their work.
@lesgarten
@lesgarten 3 года назад
Hey, great videos as usual! Been watching you for years. I am removing a Heater(won't be replaced) installing a new MultiValve and new DE Filter on my pool. There is one check valve in place. It is between the heater outlet and the return. No check valve between the pump inlet and the pool. Do I need a Check Valve? If so where? I also see a few places where there are elevated loops to prevent siphoning I guess. One is between the Pump outlet and the multivalve. The other is between the heater outlet and the return. That is also where the check valve was. Do I need to redo that heater outlet one when I remove the heater?
@SPL
@SPL 3 года назад
I would add a check back in the same spot. In case you add a salt system or chlorine feeder later. The check valve will protect the heater.
@tekleabreha4520
@tekleabreha4520 9 лет назад
hello allfrends
@XrpAndy
@XrpAndy 4 года назад
Hahahaha you almost didn’t get the suction side in fast enough 😂😂 that’s was epic I said there you go the same time you did 😂
@totheedgeacademyttea9245
@totheedgeacademyttea9245 6 лет назад
which is the inlet and which is the outlet? I have similar pump and want to connect to my pool? Cheers in advance and good video:)
@SPL
@SPL 6 лет назад
Inlet is in front of the pump. outlet is coming out of the top - known also as the discharge. Hope that helps!
@totheedgeacademyttea9245
@totheedgeacademyttea9245 6 лет назад
Swimming Pool Tips, Reviews & How To -MrDgvb1 Thank you for your reply. I watched about 10 videos and still couldnt find anyone explaining. I found my dad's old one yesterday that had been thrown in scrap metal pile. My father passed away in 2001 and I remember seeing something like a old pump off one of his ponds. We have just got a pool for the kids this summer, So I went on the scrounge and you wouldn't believe it! I plugged it in & it fired straight up, working perfect!! Saved about £500!! God bless mi old man😉. Thanks once again. Happy days👊
@SPL
@SPL 6 лет назад
Great find! 👍
@PwlTwlGuy
@PwlTwlGuy 10 лет назад
Good job, Mr.D. I think a tripod was mandatory for this clip. Where do you get your PVC white spray paint? I never see that at any of my distributors...big box hardware store? -TM
@SPL
@SPL 10 лет назад
Sears sells it - Krylon H2O Latex Spray paint. I use a light tan that looks almost white - covers a little better with one coat.
@ltp1757
@ltp1757 8 лет назад
Thanks for this instruction. I am in need of that pvc pipe extender to fit over the outside of a 2" elbow. Can't seem to find one like that. Do you have a link or part number?
@ltp1757
@ltp1757 8 лет назад
+LT P Never mind, found it. Magic Mend #0303-20. Will save me a lot of work when I replace my pool pump later this week. Thanks again for the video MrD.
@ArmenArmenjs
@ArmenArmenjs 7 лет назад
You wont find the in hardware stores, try Pool supply. cost about $1
@nicholasvarro7382
@nicholasvarro7382 4 года назад
I love the spray paint! Good as new!! What do you do when the client is standing by watching the process?
@SPL
@SPL 4 года назад
Not much you can do. I try to schedule repairs when no one is home. Easier that way.
@chengkhang2804
@chengkhang2804 4 года назад
speak a language other than what the homeowner speaks lol
@MrBmxbrawler
@MrBmxbrawler 3 года назад
Purple primer! Yikes.
@allouanilotfivlogs
@allouanilotfivlogs 4 года назад
Very good 👍 brother, I have one like it, and I need you to give me some advices to install it, please contact me
@chengkhang2804
@chengkhang2804 4 года назад
super easy. just threads and glue. just remember that the tighter the space the more precise you have to be. have a few practice rounds first.
@allouanilotfivlogs
@allouanilotfivlogs 4 года назад
@@chengkhang2804 Thank you brother I'm glad to listen to your sulations
Далее
How to Install a Pool PUMP Quick and Easy!
11:58
Просмотров 164 тыс.
Вопрос Ребром - Серго
43:16
Просмотров 738 тыс.
ОБЗОР НА ШТАНЫ от БЕЗДNA
00:59
Просмотров 391 тыс.
I Took An iPhone 16 From A POSTER! 😱📱 #shorts
00:18
Save pump headaches with high temp unions!
7:35
Просмотров 64 тыс.
How To: Install a Top Mount Pool Sand Filter
9:51
Просмотров 558 тыс.
How To Install a Swimming Pool Pump (Better)
1:25:02
Просмотров 124 тыс.
Learn Pool Plumbing with Test Tank
8:40
Просмотров 117 тыс.
How to Tune Your Pool Skimmer
8:01
Просмотров 759 тыс.
Вопрос Ребром - Серго
43:16
Просмотров 738 тыс.