How to Install Smoke and Carbon Monoxide Detectors | Ask This Old House 

This Old House
Подписаться 2,1 млн
Просмотров 1,2 млн
50% 1

Scott Caron, master electrician for Ask This Old House, wires an old house with new smoke and carbon monoxide detectors.
#ThisOldHouse #AskTOH
SUBSCRIBE to This Old House: bit.ly/Subscrib...
Steps for How to Install Smoke and Carbon Monoxide Detectors:
1. Mark the location of each smoke detector on the ceiling.
2. Use a drill and long, stiff wire to bore a small-diameter hole through the ceiling and into the attic.
3. Go into the attic and check for obstructions around the small holes. If necessary, use a circular saw to cut open the attic floor.
4. At each smoke detector location, use a drill and a 4-inch-diameter hole saw with dust shield to cut a hole through the ceiling for a round old-work electrical box.
5. Run nonmetallic electrical cable from an existing outlet in the attic to each of the smoke detector locations.
6. Cut the cable and pull it through an old-work electrical box. Push the box into the ceiling hole and tighten the screws to lock the box to the ceiling. Repeat for each ceiling hole.
7. Screw the smoke detector's mounting plate to the box, then make the wire connections: black to black, white to white, red to orange.
8. Gently tuck the wires into the box, then twist and lock the smoke detector onto the mounting plate.
9. Install a combination smoke and carbon monoxide detector on each level of the home and within 10 feet of the bedrooms.
10. Pull a new electrical cable down from the attic into the basement.
11. In the basement, install a standard hardwired combination smoke and carbon monoxide detector, and a two-piece wireless smoke and carbon monoxide detector. Mount the battery-powered wireless half of the detector on the first-floor ceiling.
12. Make the final wire connections in the attic, then test each detector to make sure all of them are operating properly.
About This Old House TV:
This Old House is the No. 1 multimedia home enthusiast brand, offering trusted information and expert advice through award-winning television, a highly regarded magazine, and an information-driven website. This Old House and Ask This Old House are produced by This Old House Ventures, LLC and are presented on PBS by WGBH Boston.
Follow This Old House and Ask This Old House:
Facebook: bit.ly/ThisOldH...
Twitter: bit.ly/ThisOldH...
bit.ly/AskTOHTw...
Pinterest: bit.ly/ThisOldH...
Instagram: bit.ly/ThisOldH...
Tumblr: bit.ly/ThisOldH...
How to Install Smoke and Carbon Monoxide Detectors | Ask This Old House
/ thisoldhouse

Опубликовано:

 

27 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 363   
@Kuwandi
@Kuwandi Год назад
Superb EDITING credits to the This Old house , so much better than every one trying to show how to do it their way ⭐️⭐️✅
@RM-lv9ng
@RM-lv9ng 4 года назад
There are so many new innovative smoke detectors, the ones installed in this video are dinosaurs.
@brandonwilson4281
@brandonwilson4281 3 года назад
👙📲🍼💏🍼🚔🍼🌪️💓🍼🌪️
@brandonwilson4281
@brandonwilson4281 3 года назад
🔥🌩️🍼😷💕❤️💩💩🛤️📱🔥🍼🇱🇷
@DanTDMJace
@DanTDMJace 3 месяца назад
He ones here are still pretty good (at least for the US, Europeans are leages ahead of us)
@mauricio6712
@mauricio6712 8 лет назад
I liked a lot , here in Brazil we do not have that device in the home...... very Good
@brandonwilson4281
@brandonwilson4281 4 года назад
🍼💅🙋🍼📽️
@celsojoven3525
@celsojoven3525 3 года назад
Laguna
@emilyrose1348
@emilyrose1348 3 года назад
Love to know you?
@eclay432
@eclay432 3 года назад
If code requires 2 sources of power to your detectors how do you get away with just a battery operated on the first floor?
@ronaldwoofer5024
@ronaldwoofer5024 3 года назад
LMAO
@drnickriviera8270
@drnickriviera8270 3 года назад
If smoke detectors are being installed in a home built prior to the hardwire code requirement than wireless smoke detectors with a non removable 10 year battery can be used. If a house is undergoing extensive renovation which would allow for the routing of hardwire power cables than the new detectors must be hardwired.
@mrsliva4156
@mrsliva4156 2 года назад
Lllllllllllllllllllooooooooo
@LeroyZee
@LeroyZee Год назад
He put a second smoke detector in the basement.
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 Год назад
@@LeroyZee for backup of smoke detector(late reply)
@PeteBasel
@PeteBasel 6 лет назад
You said, on the upper floor, that the alarms needed two power sources according to code, then on the first floor you installed a battery only unit. I'm not an expert on the code but is that allowed? Also, you can use bridge units to join a wireless trigger unit to the wired ones.
@DaruDhillon
@DaruDhillon 4 года назад
When renovating a home it is required to have all smoke and carbon monoxide detectors hardwired, interconnected with back-up batteries. Wireless is a good option, if you are not opening up walls.
@PeteBasel
@PeteBasel 3 года назад
@jay fine Thanks, that makes sense. My first post here was 3 years ago!
@jeffjiao6781
@jeffjiao6781 Год назад
Thanks for the information Johnny
@IAmNotAFunguy
@IAmNotAFunguy 8 лет назад
He never mentioned there are two kind of smoke alarms, ionization and photoelectric. Ionization is better for quickly flaming fires and photoelectric is better for slow smoldering fires, and most fire departments and building codes like them both in the house. The best is a 2-in-1 unit that has both types.
@jeremiahsimpkins5943
@jeremiahsimpkins5943 7 лет назад
IAmNotAFunguy yea he never mention them well I fell bad for this lady thank to Scott
@frank_texas7400
@frank_texas7400 6 лет назад
Now I heard that it burnt to the ground because of him not disclosing every kind of smoke detector there is
@NatSpecialOAthlete
@NatSpecialOAthlete 5 лет назад
this video will explain everything ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-714NB7CVrpA.html
@brandonwilson4281
@brandonwilson4281 4 года назад
🍼🚂🔫💰💡🔫👶👙🍼🤰🌪️💩📽️👙👶💰🔫🥋🤰👙🚂🚒❤️💡🍼👨‍👩‍👧🌩️💗🦃🙋🖤🔥📽️🌪️
@fartpluswetone8077
@fartpluswetone8077 4 года назад
Most combination alarms are Carbon Monoxide and Ionization.
@lindahernandez2063
@lindahernandez2063 Год назад
I like how it catches the dust
@MrRubme
@MrRubme Год назад
The most unrealistic attic I’ve ever seen 😂
@user-Arthxeking777
@user-Arthxeking777 3 года назад
needed this to reengineer the fire alarms in my house thank you for the wiring tips
@10MohGG
@10MohGG 4 года назад
I love how they make everything up
@yzmoto80
@yzmoto80 4 года назад
@1:30 : “Upp, there it is, right through my knee cap....No worries, I’m ok, I have another one !
@Kansasavation
@Kansasavation 3 года назад
Pot twist: The metal rod goes through Kevin
@brandonwilson4281
@brandonwilson4281 3 года назад
⚡🍼🎸💰🍼🎶🎤🎸🎙️📲💑🍼🎸⚡💒📽️💡👩‍🚒❤️🚒👙💡
@mattydubz481
@mattydubz481 2 года назад
🤣
@violetrosesoto9819
@violetrosesoto9819 Год назад
I’m o
@venividivici4253
@venividivici4253 7 месяцев назад
Plot*
@lonnellmiddleton81
@lonnellmiddleton81 7 месяцев назад
@@venividivici4253😂😂😂
@mrseanpride6449
@mrseanpride6449 3 года назад
What was the second one for? To get him out of trouble? Are the cops after him?
@fatherelijah1763
@fatherelijah1763 3 года назад
😁😁you just made me spill my coffee
@sarafitzgerald8971
@sarafitzgerald8971 Год назад
Did you use a 4 inch hole saw to make the boxes to fit? I purchased the blue plastic connection boxes showing in your video.
@matrewisdom6017
@matrewisdom6017 4 года назад
Can I use normal 3cord x1.5mm flexible cableto wire smoke alarm
@AndrewThronImprovements
@AndrewThronImprovements 4 года назад
Good tips!
@johnkosheluk1041
@johnkosheluk1041 3 года назад
Boy can't have it any easier then that running wires
@anafigueroa2463
@anafigueroa2463 7 лет назад
wonder cost of labor I have to install 6 in my house, and I prefer to be wired
@brandonwilson4281
@brandonwilson4281 4 года назад
🍼
@fatherelijah1763
@fatherelijah1763 3 года назад
@@brandonwilson4281 👻
@nevrbdwnruby7484
@nevrbdwnruby7484 6 лет назад
Sending the wires to these devices is cumbersome but there is no way out of it... Great for remodel work but I don't recommend if it was going to be inspected it will be a no pass.. Why? All devices need a dedicated circuit and they all need to be hardwired... That's what happened to me in LA...
@leonardholt5311
@leonardholt5311 4 года назад
NevrBDwn Ruby does not need to be on a dedicated circuit.
@CaptainBill22
@CaptainBill22 8 лет назад
Correct me if I'm wrong, but the last I heard the NEC says that smoke detectors should be on a separate circuit. I get that you guys did this so it's more user friendly, but the job should be done to code for today.
@nofingway1
@nofingway1 7 лет назад
codes change depending of the country/state.
@jc5536
@jc5536 7 лет назад
If the NEC states it should be on its own circuit ( individual branch circuit ) I would be interested in that chapter and section or if it's an amendment to NFPA 70 written into law and approved in a specific state or commonwealth. I'm almost inclined to point towards NFPA 72 if that even exists.
@Sparky-ce9yy
@Sparky-ce9yy 6 лет назад
Sigvulcanas you are correct. Hard wire smoke detectors must be on one circuit and are NOT allowed to be GFCI or AFCI protected.
@ronaldbeal
@ronaldbeal 6 лет назад
WRONG!!! NEC section 210.12 requires 120v smoke alarms to be on Arc Fault circuits. They should be interconnected and on one circuit. There is debate on weather they should be alone on a circuit, or be on a shared circuit. NEC, NFPA, and IRC do not weigh in on the matter. Some state and local AHJ have made a determination one way or another, and they have the final say. The fire prevention community is leaning toward being on a shared circuit, so that if the breaker is tripped, the occupants will be more likely to notice it, whereas if the alarms are by themself, someone might turn off the breaker to silence a false alarm, and then never turn them back on.
@ronaldbeal
@ronaldbeal 6 лет назад
International Code Council Electrical Code (ICCEC) :Section 1202.5 states: "Smoke detectors required by the International Building Code and installed within dwelling units shall not be connected as the only load on a branch circuit. Such detectors shall be supplied by branch circuits having lighting loads consisting of lighting outlets in habitable spaces."
@parnika.agarwal
@parnika.agarwal 4 года назад
How did you had the wireless smoke detector talking to the fire alarm system with the wires? Can you please tell which model numbers of the first alert were installed in this video?
@nick4leader
@nick4leader 3 года назад
I think the 2 in the basement are connected to each other and the wireless is connected to one of them
@kitty2ism633
@kitty2ism633 3 года назад
It uses a wireless type signal to communicate with the one in the basement which will then connect to the second one and send the signal to the rest of the smoke alarms (i know as we have a similar model ours is the sc0500 i believe)
@roderickarnold1412
@roderickarnold1412 3 года назад
Kevin almost just lost a kneecap.
@OwYouMoron
@OwYouMoron 6 лет назад
Imperial Walker spotted at 0:54
@larrynone6354
@larrynone6354 Год назад
How many inches from the wall did you measure
@gravisan
@gravisan 2 года назад
Would be good to know what cables they used? maybe it's 14/3?
@lyndoncreps4218
@lyndoncreps4218 2 года назад
14/3 is ideal for smoke detectors.
@bluesteel5841
@bluesteel5841 3 года назад
Because carbon monoxide is slightly lighter than air and also because it may be found with warm, rising air, detectors should be placed on a wall about 5 feet above the floor
@DanTDMJace
@DanTDMJace 2 года назад
No, they should be on the ceiling.
@The09creeper
@The09creeper Год назад
I would love to see some one actually put a co alarm 5 feet above the ground but no one does it because of aesthetic reasons
@atkgrl
@atkgrl 7 лет назад
Great plastic shield, Where can I buy one.
@alec4672
@alec4672 7 лет назад
PlayGirl It's just your standard cheep plastic bowl from the kitchen section with a small hole in the bottom.
@atkgrl
@atkgrl 7 лет назад
Alec Ver Bunker it's a great idea and could be sold as a tool.
@alec4672
@alec4672 7 лет назад
PlayGirl they do sell it as a tool but for much more then it's worth. I use a plastic salad bowl and it works just as well.
@brandonwilson4281
@brandonwilson4281 4 года назад
🍼🖤💡⚡🌩️🌩️🍼🔫🥋💰🍼👨‍👦‍👦🍼🔥🚒
@Tj-cq2nw
@Tj-cq2nw Год назад
I’m about to do this soon
@luigi2018
@luigi2018 2 года назад
Imagine that metal rod would drill his knee 😂😂
@Jack-vo2sz
@Jack-vo2sz 2 года назад
my exact thought "and now it goes straight thru his knee instead" 😂
@koycdjartage2571
@koycdjartage2571 3 года назад
Can i wire different brand ? I know I have to change the base ..
@guidedbygreen1480
@guidedbygreen1480 3 года назад
It's preferred they are all same brand to ensure communication, but try it
@gilzskillz
@gilzskillz 2 года назад
changed my smoked to detectors for same new ones now one in the master bedroom does not sound with the others when testing
@gamebreaker5518
@gamebreaker5518 6 месяцев назад
why wasn;t the second screw in the first box he wired screwed down?
@Dggb2345
@Dggb2345 3 года назад
Dude, saw comment about on knees before watching...Lmfao. Laurel & Hardy level potential.
@brandonwilson4281
@brandonwilson4281 3 года назад
🍼🌪️🔫👙💏🤰🌛🔥👙🕑🚂🍼💡⛈️🔥
@brandonwilson4281
@brandonwilson4281 3 года назад
⚡📲🚧🇲🇾💰💑❤️🚒🍼🎸🔊🎤☎️👙📲💰🚒🍼❤️
@POLOAZTECA
@POLOAZTECA 3 года назад
For smoke detectors where exactly in a bedroom go?? Like what's a best location in a bedroom... How far away from vents or it doesn't matter?
@gangisspawn1
@gangisspawn1 3 года назад
On the ceiling in front of the door. Sometimes one on both sides of the door for extra safety(apartment code).
@POLOAZTECA
@POLOAZTECA 3 года назад
@@gangisspawn1 Thanks
@kickdrum1185
@kickdrum1185 3 года назад
Will 12/2 wire work or 12/3. I noticed he had red wire?
@aurvaroy6670
@aurvaroy6670 3 года назад
12/3 for alarms with a red interconnect wire and 12/2 for alarms without that extra wire
@garyvanrheenen181
@garyvanrheenen181 Год назад
Do all the detectors need to be on the same power source? Can detectors on different floors have different power sources as long as they are all connected to a single red wire running from one the next?
@The09creeper
@The09creeper Год назад
They can have different power sources. As long as the interconnect wire is connected they’ll all sound
@ManleyDestine
@ManleyDestine 2 года назад
Aren't fire alarm systems supposed to be on a dedicated circuit?
@easyroc75
@easyroc75 2 года назад
Some places require a dedicated circuit. He said if someone turned the circuit breaker to the dedicated circuit, no one would know. However, I think the alarm with a battery backup would beep if the AC power is turned off.
@ManleyDestine
@ManleyDestine 2 года назад
@@easyroc75 Yes, though the system is supposed to have redundancy. Supposed everyone is awa for a weekend and that circuit trips and battery power goes out within the 24 hour limit or 48 depending on how much juice is in it? Come back don't realize that cicuit is off because it's on a circuit not being used and boom, fire while your family is sleeping.
@samirrebel5473
@samirrebel5473 Год назад
Where does the end of the orange wire connect to
@Pr0gr3ss
@Pr0gr3ss 3 года назад
Is it required to shut off power in the house while attaching those colored 3 wires?
@hoivothi1997
@hoivothi1997 3 года назад
Wdt
@hoivothi1997
@hoivothi1997 3 года назад
.
@hoivothi1997
@hoivothi1997 3 года назад
.
@hoivothi1997
@hoivothi1997 3 года назад
..?..
@oldtwinsna8347
@oldtwinsna8347 2 года назад
Definitely turn it off. Only after you got it wired in and have a modular connector for future replacement would you not need to turn power off (works light plugging in socket).
@thomaschristopher8593
@thomaschristopher8593 2 года назад
great video. i was able to replace my two smoke detectors. thank you.
@OfficialNewAndImproved305
@OfficialNewAndImproved305 3 года назад
I had professionals install 5 of those and it wasn't cheap
@cantlean4440
@cantlean4440 2 года назад
I'm curious how much it was. I am guessing $80 per unit plus labor and materials. Maybe around $900?
@baliramdigitech
@baliramdigitech 2 года назад
I also use that type of wiring
@FireDetection101
@FireDetection101 6 лет назад
Might use this information when I get my own hardwired Smoke/CO alarms
@kevingordon669
@kevingordon669 3 года назад
Loop you tape into itself, it makes for easy removal, I've heard it call the buddy tab idk just don't get fired
@heroknaderi
@heroknaderi 3 года назад
Great idea 💡
@gavilanjuarez1053
@gavilanjuarez1053 6 лет назад
Hey I have question how connect the smoke detector to the breaker box
@lmd6204
@lmd6204 6 лет назад
It is connected to the outlet in the attic which is already connected to the breaker box.
@Nick-bh1fy
@Nick-bh1fy 4 года назад
gavilan juarez it’s straight 120 line voltage
@brandonwilson4281
@brandonwilson4281 3 года назад
🔥🍼🤡💷🔥🇺🇸💡💏🍼🇺🇲🇺🇲
@brandonwilson4281
@brandonwilson4281 3 года назад
@@lmd6204 🔥
@bigvic1787
@bigvic1787 2 года назад
I see how you wired the fire alarms but how did you wire it into the outlet in the Attic.? I noticed it's a 14-3 Romex so where did you connect the red for power was there a 14-3 already in there? What if it's a 14 -2 that's already existing there?
@thatbrownkid9783
@thatbrownkid9783 Год назад
I’m sure he pigtailed the hot & neutral from the back of the outlet and didn’t use the red wire
@lukekoesler3383
@lukekoesler3383 6 месяцев назад
The 14/3 red wire is just needed for communication in between devices. It should not be tied into a power source. So a14/2 is your power supply. But in this video that means it's not talking to the lower floor devices unless he pulls a new interconnecting wire or uses a remote transmitter of some kind.
@MODKILLER-od7pk
@MODKILLER-od7pk 8 лет назад
That's a nice house
@brandonwilson4281
@brandonwilson4281 3 года назад
👙👩‍🚒🍼🚧👩‍🚒🍼👙🎸💡⚡🎙️📲🌜🎶💰🚒
@_imran_4205
@_imran_4205 7 лет назад
full episode not availiable in this link
@seanlyons8053
@seanlyons8053 6 лет назад
What type of electrical wire did you use?
@gurmindersingh1424
@gurmindersingh1424 6 лет назад
My washer is broken and I want a new washer thanks.
@mrtraindeveloper475
@mrtraindeveloper475 6 лет назад
gurminder singh just get a new one
@herculesskinny2030
@herculesskinny2030 5 лет назад
Go to home Depot or lowes to go pay for a new one.
@fatherelijah1763
@fatherelijah1763 3 года назад
i like Barcelona
@Kirby7601
@Kirby7601 4 года назад
Can of smoke is better than the test button
@mohamadboodhoo
@mohamadboodhoo 3 года назад
Hi I have noticed the smoke alarm beeping,I have disconnected it from the wire but I noticed the beeping has moved to the ceiling light and its continuously beeping every 5-10 sec 24/7.Any solutions please? Thanks
@gangisspawn1
@gangisspawn1 3 года назад
Battery needs changing... if you can't figured that out then hire a handyman for ALL issues in the future.
@oldtwinsna8347
@oldtwinsna8347 2 года назад
Just find an exact replacement for it if you've done the battery change and it still does it . These have maximum lifespans and some will beep at that point, or they just crap out over time. The same model will fit the existing mount and so it can be swapped out in like 1 minute time.
@ayanhussain6798
@ayanhussain6798 6 лет назад
@ThisOldHouse if you mute a detector in one room will if mute all of the others?
@10MohGG
@10MohGG 4 года назад
Ayan Hussain no
@brandonwilson4281
@brandonwilson4281 3 года назад
🍼🔫💡🚧✏️⚡👙
@stardelta9508
@stardelta9508 6 лет назад
Wow, i know your code is different from scotland, but why no earth sleeving?? It just makes sense. Any US sparky would learn alot if they worked over here for a few days.
@AMD1
@AMD1 4 года назад
It's not necessary to have the ground/earh covered since it's not a normal current carrying conductor, and usually bonded to the back of a metal box. North American codes say that the ground/earth must be identified with green insulation, green with a yellow stripe, or bare coper. I believe Australia also has a bare ground/earth conductor in their NM cable/twin and earth.
@alexandersalarms5380
@alexandersalarms5380 4 года назад
7:07 he is using too much smoke, one spray is enough. you will damage it.
@ihatekaleb
@ihatekaleb 4 года назад
Ikr
@razorcool5011
@razorcool5011 3 года назад
Spray
@alexandersalarms5380
@alexandersalarms5380 3 года назад
@Anthony Lee The smoke alarm...
@brandonwilson4281
@brandonwilson4281 3 года назад
🍼🚓🧠🛫🛩️♥️🚑♥️🍼😍🏈🎂💺🎃🧤🔦💡💵🛍️🕯️🙋🚴⛹️🏋️💆🙇👩‍🚒👩‍👩‍👧🌩️🍼🎂🚔🎤📹💡👙🗄️🕞💜🎦🕣🇱🇷🇺🇾💰📲🔴🔵🔊😡😤😠💰📞📲
@alexandersalarms5380
@alexandersalarms5380 3 года назад
@@brandonwilson4281 shut up
@DCC--vq1ng
@DCC--vq1ng 4 года назад
I think a commercial fire alarm system might be a good choice if you have enough money.The solution can be like this: 1.unimode 2000 UDLS FACP in basement or garage 2.fire lite LCD-40 annunciator in entryway 3.some BG 12LX pull stations installed throughout house. 4.spectr alert low frequency horn strobes in sleeping areas 5.gentex horn strobes in living area(tone set to code 3 mechanical or whoop)
@alexandersalarms5380
@alexandersalarms5380 4 года назад
You must be drunk because this is a house.. not a restaurant
@The09creeper
@The09creeper Год назад
A little too over powered. Tho if you want something like that then get a security panel and wire up a few fire zones
@omegalpha777
@omegalpha777 8 лет назад
Quick Question, if a person is hearing impaired and is living alone, how can she/he knows if a fire is starting?
@jackdoble2
@jackdoble2 8 лет назад
They make smoke detectors with strobes, perfect for someone that is hearing impaired.
@rdcstyle6612
@rdcstyle6612 8 лет назад
+bobloblaws911 those vibrator alerts are very handy usually they install them between then individuals private parts for max alertness and stimulation
@muscleman569
@muscleman569 7 лет назад
THEN THEYRE FUUUUCKED!!!!!!!!!!!!!@!!%
@atkgrl
@atkgrl 7 лет назад
Jack where can you buy them?
@davidredpath4781
@davidredpath4781 6 лет назад
Mark R they make horn strobes for that situation
@roshanr16896
@roshanr16896 3 года назад
He is using too much of smoke, one spray is enough at 7:07
@djtippler8259
@djtippler8259 6 лет назад
What kind of wire that you use in smoke detector ?
@darrenwoloshyn
@darrenwoloshyn 4 года назад
Dj tippler 14/3 NMD 90
@amodelanime2
@amodelanime2 2 года назад
Awesome video thanks
@UneasyBBJ
@UneasyBBJ 4 года назад
Was there a battery in the wireless one he installed? I didn't see one.
@ethanmacias7287
@ethanmacias7287 4 года назад
At 6:12 that's the battery and wireless one he installed
@matth8200
@matth8200 2 года назад
I've always heard that carbon monoxide detectors should be low to the ground, since carbon monoxide sinks. Is this wrong?
@TheSgtDabbs
@TheSgtDabbs Год назад
It doesn't really matter what height they are at, CO spreads pretty evenly throughout a given area.
@shahilrabbani5973
@shahilrabbani5973 6 лет назад
Good
@floxysfeed4448
@floxysfeed4448 6 лет назад
Pls can I get a technical report on this
@safekid101firesafetyandexi8
@safekid101firesafetyandexi8 7 лет назад
I wanted to know that .
@brandonwilson4281
@brandonwilson4281 4 года назад
🍼🤰
@brandonwilson4281
@brandonwilson4281 3 года назад
🍼💡💡❤️💏🎥🔫🔥
@ebrukucuk1471
@ebrukucuk1471 3 года назад
Zzz😼
@ebrukucuk1471
@ebrukucuk1471 3 года назад
@@brandonwilson4281 dhegjegjwgejegeuegeigruegeufeyegjegejegehegeje
@mannythesavage2
@mannythesavage2 3 года назад
I saw sparks at 2:20
@johnkosheluk1041
@johnkosheluk1041 3 года назад
What good is that if thay are not home
@Nine-Signs
@Nine-Signs 7 лет назад
Bugger the smoke detectors, what were those red terminal caps you were twisting wires together with? Ive done electrics for a long time in the UK and have never seen such things before. would save time over solder and shrink wrap that's for sure.
@nofingway1
@nofingway1 7 лет назад
en.wikipedia.org/wiki/Twist-on_wire_connector super cheap in any hardware store.
@nofingway1
@nofingway1 7 лет назад
www.homedepot.com/p/Wire-Connector-Assortment-25-Pack-775128/202894260
@Nine-Signs
@Nine-Signs 7 лет назад
thank you :)
@jenkins6421
@jenkins6421 7 лет назад
ArmyOfAll just remember its 110v in the us compared to 220 over there
@zakadamson6059
@zakadamson6059 6 лет назад
James Jennings not being cocky but letting u know its 240~250 volts. So soldering is a musg
@speway
@speway 6 лет назад
No Red FPLR Alarm Cable? Why?
@dunnitt
@dunnitt 6 лет назад
120 volt units . They are not connected to a alarm system
@fnhwk
@fnhwk 4 года назад
It's a house, not a hospital.
@abrahamvaro1637
@abrahamvaro1637 6 лет назад
very good video ,thanks.
@gemmell761
@gemmell761 2 года назад
That guy does not value his kneecaps
@priceandpride
@priceandpride 3 года назад
Is it possible to get them all to chirp at the same time?
@Vanilla_Icecream1231
@Vanilla_Icecream1231 3 года назад
That’s what the red wire does
@masteryoda7583
@masteryoda7583 2 года назад
So if my cooking sets off my detector how do I turn it off?
@AMD1
@AMD1 Год назад
Use a shotgun
@generally_good_guy
@generally_good_guy 4 года назад
This was a great video. Unfortunately I need to do a hardwired install in the location you put wireless. Any advice on running the cables?
@aurvaroy6670
@aurvaroy6670 3 года назад
I'm pretty sure you take the same steps Scott took (run romex from a nearby power source to each location) without having access to an attic. There are plenty of videos showing you how to do that
@Kuwandi
@Kuwandi Год назад
Thanks to this old house addiction 34 yrs ago I bought an old house - lol - it’s a bit older now …lol?
@baliramdigitech
@baliramdigitech 2 года назад
Nice Device
@pieceofcake2008
@pieceofcake2008 8 лет назад
Love the show. Always interesting seeing how it's done overseas.
@brandonwilson4281
@brandonwilson4281 2 года назад
89
@suzannebrackett8450
@suzannebrackett8450 Год назад
I love the video
@bignedu4871
@bignedu4871 4 года назад
Thank you for this tutorial.
@amilcarduglasbenites583
@amilcarduglasbenites583 8 лет назад
que bien.practico.y eficas
@dene8989
@dene8989 3 года назад
If battery is moved but powered by wire, will it always chirp?
@6string327
@6string327 3 года назад
yes, the battery is only if the power goes out. If it's also hard wired your good.
@oldtwinsna8347
@oldtwinsna8347 2 года назад
there's usually voltage monitoring for the backup battery so if it gets old the battery can invoke the chirping to start.
@onecrazywheel
@onecrazywheel 8 лет назад
Just to notate. If he added that wireless on on the first floor a person can just have all of them be wireless and skip any of the wiring. Cost more upfront but cheaper on labor costs...
@143home
@143home 7 лет назад
Yes but wireless detectors that communicate to each other are battery killers. Cost of labor is easily made up after a few years of replacing batteries. Most of them take a lithium battery too, not your standard 9v
@brandonwilson4281
@brandonwilson4281 2 года назад
🍕🍼👨‍👩‍👧‍👧🍼🔪🎂💖🧑‍🦲🍼
@The09creeper
@The09creeper Год назад
@@143homethey do eat up battery that much and most of them take standard AA and 9v batteries
@kevinnaylor5737
@kevinnaylor5737 3 года назад
Pretty sure its supposed to be on its own power source. 15 amp arc fault breaker, 14-2 to the first and 14-3 in between others 🤷
@ryanwoods4691
@ryanwoods4691 3 года назад
No, you are wrong. He said why they share circuits in the video. If the smoke detectors get shut off then you would want to know. So if your master bedroom lights are off, then you know your smoke alarms don't have power.
@easyroc75
@easyroc75 2 года назад
@@ryanwoods4691 A smoke detector that has both AC/DC power will beep if the AC power is turned off. Correct?
@ryanwoods4691
@ryanwoods4691 2 года назад
@@easyroc75 it depends on the model of detector.
@miguelprado5043
@miguelprado5043 7 лет назад
just dril don't worry about water lines
@Est91.
@Est91. 5 лет назад
Why would he worry about a waterline when above the bedroom is an attic?.. what would a waterline be doing above a bedroom on the 2nd floor? .. this makes literally no sense
@spencerg3303
@spencerg3303 2 года назад
It’s so terrifying to hear a robot voice at night saying warning Carbon Monoxide, especially since it echos the entire house, but I’d rather live than die from Carbon Monoxide
@Bugatti381
@Bugatti381 6 месяцев назад
Please see Manuel
@GalaXy808
@GalaXy808 8 лет назад
Wow very nice job,is that a new type of smoke detectors the other one?
@jred4421
@jred4421 2 года назад
This is an extremely important informational video which can potentially save lives, first & foremost, no argument whatsoever, hands down. BUT...Why weren't the floor/attic ceiling joints explained to the viewers? Or, how magically the wires are passed thru the joist? This appeared to look way too simple but it's commonly unknown to the average person of joist layouts. Only the pros know the joist layouts, along with the required tooling and required skills to run wiring thru the joist. That was not clearly explained in this segment. C'mon folks...OK, the lighted fish tape was a nice touch, at best. But have to ask...What enabled the fish tape to get from point A to point B? Drilling of the joist? And the required tooling to accomplish that? Do you truly think that any homeowner could just simply pass the wiring without pre-drilling the joist? Thinking there is some quality editing improvement potential prior to public release. Again though, this is an extremely important informational video which can potentially save lives, no argument whatsoever.
@The09creeper
@The09creeper Год назад
That’s why sometimes you got bring in a licensed electrician.
@procellfoxreal
@procellfoxreal 3 года назад
PLEASE SEE MANUEL. (SCO500)
@Photoelectric_Elevators
@Photoelectric_Elevators 3 года назад
Lol
@procellfoxreal
@procellfoxreal Год назад
​​​@Photoelectric Elevators LOL (sorry I took 2,000 years)
@PBunyanOx
@PBunyanOx Год назад
Kevin!!! 🏡
@Rulebritania25
@Rulebritania25 2 года назад
2:21, an electrical wire???
@jake78441
@jake78441 8 лет назад
WELL can someone explain why your need a Carbon Monoxide if you have all electric in your house because I have a Electric stove I dont have anything gas in my house?
@Aaronproductions
@Aaronproductions 8 лет назад
It detects low smoldering fires or if someones car or genorator or something else emits that gas and it gets inside your house you want to know so you can get out safely and stop the source of the problem or call 911
@jake78441
@jake78441 8 лет назад
Becuase our house just has the one in our hallway Aaron Productions
@alistairism
@alistairism 8 лет назад
Even if you don't have any gas appliances. It is still recommend to have one, as carbon monoxide can be produce from more things then you may think.
@AutoUnder
@AutoUnder 6 лет назад
0:22 "Code requires 2 sources of power now" But he installs a battery powered smoke detectors downstairs
@ethanmacias7287
@ethanmacias7287 4 года назад
He said that it's the most difficult place to get the smoke alarms wired to
@ranganathkrishnamurthy9979
@ranganathkrishnamurthy9979 3 года назад
I don’t think running power to the device is the difficult part but having all the devices connected through the orange cable is the most challenging part.. so it makes sense to choose a wireless one to connect with the other devices but I would have also hooked up the device to power in addition to having a battery
@morffi1123
@morffi1123 2 года назад
It's doble battery
@Self_Supremacy
@Self_Supremacy 6 лет назад
There is jo way i could have been in that attic while he was drilling those rods without screaming " oh god my knee, you drilled it through my knee".
@bobbygecko
@bobbygecko 6 лет назад
she blinks way less when scott is taking to her than kevin... weird
@fatherelijah1763
@fatherelijah1763 3 года назад
😁😁
@user-Arthxeking777
@user-Arthxeking777 3 года назад
XD lmfao
@alexsahib5669
@alexsahib5669 3 года назад
Blink rate tends to increase when people are thinking more or are feeling stressed
@brandonwilson4281
@brandonwilson4281 2 года назад
🍼🧑‍🚒💖🍼💏💏🍼🧑‍🦲🍼🔪🔪👱‍♀️🍼🎂
@brandonwilson4281
@brandonwilson4281 2 года назад
@@alexsahib5669 🍼👱‍♀️🎂🍼🥞🎂🍼🙄👨‍👩‍👧‍👧🎂🍼👱‍♀️👭👱‍♀️🔪💏
@UnionPacificBigBoy-of8xy
@UnionPacificBigBoy-of8xy 4 года назад
5:20 First Alert SC9120B
@grantmiller6147
@grantmiller6147 4 года назад
2:20 why did it look like an arc cutting the saw?
@Nick-bh1fy
@Nick-bh1fy 4 года назад
Most likely friction from the metal wholesaw against the wood but definitely not an electrical arc
@roshanr16896
@roshanr16896 3 года назад
You installed battery powered smoke detectors down stairs, There’s no place to wire a smoke detector downstairs
@brandonwilson4281
@brandonwilson4281 3 года назад
🍼👙👩‍🚒💰😠😤🍼👙🌩️💡
@abelluz5698
@abelluz5698 8 лет назад
11-- how interconnected ?
@edduanchavez3346
@edduanchavez3346 4 года назад
The red wire connects between the smoke detectors, this red wire is called the signal wire, as soon as one detects smoke it carries the signal to the rest
@abelluz5698
@abelluz5698 4 года назад
Treasper Killa thanks, about wireless how take signal to the others?
Далее
Wife habit 😂 #shorts
00:16
Просмотров 65 млн
Кого из блогеров узнали?
00:10
Просмотров 461 тыс.
Wife habit 😂 #shorts
00:16
Просмотров 65 млн