@murky2502
@murky2502 5 месяцев назад
Can you extend the distance from the float to the alarm by running THWN in conduit, or UF cable?
@sjerhombus
@sjerhombus 5 месяцев назад
Yes, you can extend the wire from the float to the alarm. This is a low voltage low current circuit on the Tank Alert AB and using 18 AWG wiring you could run up to 500 feet one way. You could use either UF or a run through conduit which would make it serviceable in the future if additional wiring is needed between the two points. If conduit is used we recommend sealing the conduit to prevent sewer gas and moisture damaging your wire splices and escaping from the tank. If you need further assistance, please contact our tech support at 888-342-5753.
@Syncsparky
@Syncsparky Год назад
Do you have any videos of the tank alert AB sounding? Id like to hear what it sounds like, mine recently did not give an audible alarm and i ran out of water. I belive the LED worked, but we 100% did not get any sounds or do any silencing.
@sjerhombus
@sjerhombus Год назад
The horn on the Tank Alert AB alarms around 87 decibels which is incredibly loud if you are in front of the unit. You could check the time stamp of this video at 4:22 to hear the unit alarm but please note that in person will likely sound different. For troubleshooting you could unplug the unit for 5 seconds then plug it back in. With the power restored, try hitting the test button on the front of the unit. If the horn sounds, then you may have an issue with your alarm float circuit. If the horn does not sound, that would indicate that the horn has exhausted its lifespan and the Tank Alert AB would need to be replaced. If you would like to talk to our tech support team you can give them a call at 1-888-342-5753 ext. 2. Thank you.
@budacah
@budacah 3 года назад
My SJE tank alert wiring and float were replaced 4 mos ago..now the alert box is making a buzzing noise ..and no..the red light is not on...I'm confused as to what may cause this and what may happen...thanks for any help
@sjerhombus
@sjerhombus 3 года назад
Hi! Please contact our Tech Support team for assistance with this issue! For product technical support: 800-746-6287 techsupport@sjeinc.com
Далее
Your Septic System: Worst Mistakes
16:44
Просмотров 1,6 млн
What to do When Your Septic Alarm is Going Off
16:06
Просмотров 230 тыс.
would you eat this? #shorts
00:35
Просмотров 1,8 млн
“Bernabéu… pressure… 90,000” 🔥🔥🔥
01:02
SJE Rhombus MySpy™ WiFi Messenger Sump Alarm
6:50
Просмотров 1,9 тыс.
Troubleshooting Floats Out of Sequence | SJE Rhombus
9:53
Tank Alarm Training | SJE Rhombus
5:46
Просмотров 20 тыс.
The Greenwich Meridian is in the wrong place
25:07
Просмотров 821 тыс.
Float Switches: How Do They Work? | SJE Rhombus
7:04
How To Wire a Septic Tank Pump & Alarm System
14:03
Просмотров 132 тыс.
SJE Rhombus Model 112 Control Panel at WWETT 2022
1:41