How to Plumb a Comet P40 gas softwash system. 

Blue Collar Entrepreneur
Подписаться 473
Просмотров 17 тыс.
50% 1

In this video we go over how to plumb a Comet P40 gas softwash system with a proportioner and remote shut off setup from Midwest Washing Equipment.

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 139   
@RyansSoftwash
@RyansSoftwash 8 месяцев назад
Bought a P40 and found it difficult to get good info out there on plumbing. Thank you so much much for the info man! This is so helpful
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 8 месяцев назад
Glad the video helped. Enjoy your new machine
@littlespressurewashing
@littlespressurewashing 2 года назад
Very simple instructions and great video 👍 I own a Comet P 40 as well with a blend manifold system. I am getting the automatic shut off soon and this really breaks it down! Thanks for this video bro!
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Thanks for watching!
@michaellaserre1624
@michaellaserre1624 3 года назад
Thanks for the detailed video. Just picked up a brand new gx200 for $250 off of Facebook and now I know how to set up the pump properly.
@michaelricklefs1379
@michaelricklefs1379 3 года назад
Finally! A really good video on the P40. Very well detailed and great info. Thanks for sharing.
@garypick
@garypick 2 года назад
Thanks for posting. After some research, I spoke with Comet and they reiterated some of your points including the 1/2 hose for the discharge line and 3/4" for the distribution line. I found it interesting that there are three oil reservoirs so users should ensure all three have proper oil levels. If I were you, I would post links to the items you purchased. I've been trying to find a 3/4" 200' 600 PSI chemical tube for the past couple of days and have been having trouble. One company yesterday told me it would be about $1200. Nozzle's and appropriate fittings to ensure the full 11 GPM and a chart with an overview of what effect the distance of the hose has on the PSI and GPM would be useful also. I have one application at a large movie theater and am worried that I won't be able to reach the top of the building without using some kind of extension wand or lift and, in the past, using a lift significantly affected the water pressure when up 30 or 40 feet or more.
@PressureCleaningSch
@PressureCleaningSch 3 года назад
Excellent video and easy to understand. Have a client wanting this installed on his P40, I'll reach out to Midwest.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
Thank you Doug! They will love it. Ours is still going strong with no issues.
@PressureCleaningSch
@PressureCleaningSch 3 года назад
@@bluecollarentrepreneur3377 yeah I had a Udor gas operated one years ago. Nothing but headaches, looks like these have improved over the years. May have to try one again myself.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
@@PressureCleaningSch yes sir these are a huge improvement and easy to work on
@bjbruce9643
@bjbruce9643 2 года назад
On a technical note, I guarantee you will also get better flow than the 90 turn at bulkheads.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
Absolutely
@heathkinzer7772
@heathkinzer7772 2 года назад
This has been the most helpful video for rigging up my own system. Thank you for posting.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
Glad I could help! Enjoy the new setup
@allinonepws
@allinonepws 10 месяцев назад
I’m about to do this same thing with my P40. Do you think I could use 1” inch hose for everything instead of 3/4”? I don’t want to cut 1” holes in my tanks if it won’t work as well but I have a ton of 1” hose on hand. Thanks for the help. Great video.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 10 месяцев назад
Yes you definitely could no problem
@allinonepws
@allinonepws 10 месяцев назад
@@bluecollarentrepreneur3377 Thank you. 🍻
@mdpressurecleaningsoftwash8190
@mdpressurecleaningsoftwash8190 9 месяцев назад
Thanks for the video! My buddy Coty from First Source told me about this video seeing how I was late to the game of setting up the Hydromixer lol. He told me to send a shout out to ya. :)
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 9 месяцев назад
Coty is my boy
@DumbCarGuy
@DumbCarGuy 3 года назад
I use a "bypass tank". instead of running 25' of hose just run it in and out of a 10 gallon tank. Much safer, easier and a good piece of mind.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
What happens if you want to by pass for 2 minutes? At 10gpm you would fill up a 10 gallon tank pretty quick.
@BrianDimeADozen
@BrianDimeADozen 2 года назад
@@bluecollarentrepreneur3377 Couldn't you plumb it back to the water buffer tank, assuming the "house fill hose" has a hudson valve on the tank? It won't overflow the buffer tank since it is just recirculating water, even when its full (if the hudson is working properly)
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
@@BrianDimeADozen no because if you have SH in your mix then you are sending back chemicals to your water tank. Not ideal if you have pressure washers plumbed to same tank. If you only use the P40 for rinsing with water then yes.
@xtremepowerwashing1815
@xtremepowerwashing1815 2 года назад
I like that idea 👍🏼
@elsolitarioangelito
@elsolitarioangelito Год назад
Wow my man you're really good explaining everything pretty clear and understandable all you said i really enjoyed your video, thanks!!
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Thank you Jose! Glad I could help
@prowash6852
@prowash6852 2 года назад
Great Video! I wish the larger mixer valves were available when I was getting into the soft wash industry(probably were just hard to find). I love those motor and pump setups! The AG industry has been using them for decades treating lawns and pest control. I got the best option available at the time which was a 1hp booster and proportioner from the power wash store which is way undersized mixing valve system with 1/2" GF valves(should only be used for soap). Once the boosters wear out I'm defiantly switching to gas pumps. Question; Have you tried running a 1" hose for your bypass line instead of the 1/2"? It would give you more water volume/less friction which should make the pump run cooler on your down time. A accumulator tank would help a lot too on the bypass line. The more water it has to circulate the cooler the pump will run.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
I have not tried a 1” bypass. Never thought of it since the pump comes with a 1/2 barb for the bypass. However I do like the accumulator tank idea. The same original pump is still working today. We’ve had to make some small minor repairs but other than that the pump is still running strong everyday.
@dcsc4895
@dcsc4895 2 года назад
could you explain to me a bit more about an accumulator tank. This would just get plummed in line? how does it work/make it cooler? thanks
@garypick
@garypick 2 года назад
@@bluecollarentrepreneur3377 I'm going to second the accumulator tank comment. How would that make it run cooler?
@REXONATER70
@REXONATER70 2 года назад
I like what your saying. I’m gonna jump up to this system in the next month.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
You won’t regret it.
@deanweingarth5120
@deanweingarth5120 Год назад
Can you possibly go over the bypass a little further. Questioning where to tee into and a possible check valve.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
The bypass goes back to your proportioner. A check valve can go anywhere in between those points. I’ve seen them right on the bypass of the pump or attached right to the proportioner
@deanweingarth5120
@deanweingarth5120 Год назад
@@bluecollarentrepreneur3377 What i'm looking to do is use my 12v for small groundwork jobs and backup if needed. Right now my 12v pump hose has a banjo cam lock disconnect to the outlet of the proportioner. I want to use the P40 primarily as a roof pump so I can install the same cam lock on the line feeding the P40. This way all I have to do is disconnect the 12v and connect the p40 on that proportioner output. I also have a 3 way valve after the 12v so I can either feed the hose reel, or switch to a dump hose for flushing and rinsing my trailer down if I get chems on it. My thought is to tee the P40 bypass into the hose that will feed the P40 and install a check valve before the T so there's no backfeed.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
@@deanweingarth5120 well you have some other variables to consider here. The proportioner for the P40 needs a minimum of 3/4 valves, but preferably 1”. So if your current proportioner is smaller than that it won’t work. Next, I highly suggest not using a cam lock on the intake side of the P40. The death of gas diaphragm pumps is air. A cam lock could be an easy access point for air, plus every time you disconnect it you might have to deal with priming the P40, which can be a pain if you don’t do it right. My opinion, give the 12V and P40 their own proportioner and feed them to the same reel on your trailer. Just put a 3-way valve and you can select if you want to select the 12V outlet or the P40 outlet. That my personal opinion. But to be honest once you get the feel for the P40 and know how to use it, you probably won’t be touching the 12V too much
@deanweingarth9586
@deanweingarth9586 Год назад
@@bluecollarentrepreneur3377 I appreciate the input. As far as prime, the cam lock would not be near the p40 pump, but rather up higher and a 3 ft away at the proportioner so not concerned about that. If I do lose prime I can use the washoff dump line to reprime with clean water. Now the size of the proportioner is a different story but I can build a new proportioner at the larger size and just swap the smaller size out. I keep all your info in mind and thank you!
@corymiller2186
@corymiller2186 5 месяцев назад
You are the real MVP!
@boatingagain1887
@boatingagain1887 3 года назад
Nice setup. Where did you get your blue crush proof hoses, stainless tank filters, and tank seals. I like the hydro mixer setup. Where did you get your 12v three way valve as well. Keep the content coming.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
Thanks! So the blue hose, stainless steel strainers, and “uni-seals” came from Midwest Washing Equipment. We also got the proportioner and the 12v valve setup from them.
@sieveringsouthernshine6148
@sieveringsouthernshine6148 2 года назад
Thank you for this video. I had my bypass hose running back to my water tank. Luckily I'm just setting this up. Why does the bypass hose need to 25' long? I have the comet mp30gr.
@TexasWatchman
@TexasWatchman 3 года назад
Excellent video.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
Thanks! Hope it helps
@scottruch674
@scottruch674 3 года назад
Badass set up bro, whats the difference between the p40 and the AR 45 ( which is better) Thinking about contacting Brian and pulling the trigger on one.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
The Comet P40 was designed for the soft washing industry vs the AR-45 which was not designed. Also the P40 was designed to have less points on the pump that can fail and is MUCH easier to service vs the AR-45. In my opinion the P40 is superior.
@scottruch674
@scottruch674 3 года назад
@@bluecollarentrepreneur3377 thanks for the input sir appreciate ya.
@jamesplasch6629
@jamesplasch6629 Год назад
Couldnt you you swap out the 3/8 fitting at pump and run 5/8 so it matches hose real?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
The outlet at the pump is 3/4. That’s how it was designed and I would leave it that way. Restricting the outlet size right at the pump may put some unnecessary strain on the pump
@robertdelucia6305
@robertdelucia6305 Месяц назад
Prob a stupid question but what if you had a buffer tank in the middle of you 25’hose?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Месяц назад
@@robertdelucia6305 a mean it’s a valid question. There are 2 main problems. 1) You would need the tank to feed back into the system otherwise it would just overflow. 2) The problem with feeding that buffer tank back into the system is that the buffer tank would then fill with the type of solution you are spraying. So if you are spray a chemical solution and let off the trigger, the tank then fill with a chemical solution. Well what happens when you switch to water? The system would then be adding a chemical solution back into the system when you’re trying to spray fresh water. It just makes the plumbing much more complicated and not worth the headache
@easternsoftwash
@easternsoftwash 3 года назад
Where did you get the 3/4 hose to go to the hose reel can't find anything anywhere that's over 300 psi
@codymayer4411
@codymayer4411 7 месяцев назад
Think I could get away with the original hydro mixer instead of the xl for a season? Already have the original one and it’s 3/4 plumbing. I have an udor 40 p
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 7 месяцев назад
Tough call. More than likely will restrict the pump and might burn it up. If you’re willing to possibly burn up the pump then give it a shot. You’re better off just setting it up the right way. You should make your money back in no time
@nxt-gengaming8453
@nxt-gengaming8453 Год назад
Hey man thanks for the advice, where do you buy your comet p40?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Hey man, a ton of suppliers sell them. Honestly call around and find the best price, they are all the same. I personally used North Georgia Airless and had a good experience. I prefer a Honda GX200 engine but you will find some suppliers sell it with a different engine. Pick your favorite, hook it up, and go make some money
@nxt-gengaming8453
@nxt-gengaming8453 Год назад
@@bluecollarentrepreneur3377 yeah for real bud! Demand is rising im making money now with an x-jet, but I’m getting bigger houses now and it’s time to step it up become more efficient time is $
@paultorre2419
@paultorre2419 Год назад
Great info. Thank you for the video.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Glad it was helpful!
@mightycleanhousewash2833
@mightycleanhousewash2833 Год назад
Excellent info and if you ever get tired of washing you have the ability to teach. Do you still use the comet and would you change anything from 2 years ago?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Thank you, I am glad I can help others. Yep it gets ran hard and all my buddies running them as well. With proper maintenance and care it’s been reliable. When you have employees it’s a little tricker but at the end of the day I still think it’s the best option. When I see a 12v it seems like a squirt gun
@mightycleanhousewash2833
@mightycleanhousewash2833 Год назад
@@bluecollarentrepreneur3377 that’s funny. I agree about the 12 volt being a squirt gun.
@malloryathey6ify
@malloryathey6ify 3 года назад
Are you able to get a 1% mix or you have your down set on 2 or 3% mix thanks in advance and great video keep up the good work. Looking forward to it performance video also and how far are you getting with it.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
We use this system and use a 1% mix almost daily. You can’t really go below 1% on this system, however that has never been an issue. I will try to post performance video soon!
@malloryathey6ify
@malloryathey6ify 3 года назад
@@bluecollarentrepreneur3377 thank you looking forward to the new video.
@Ben-sv9op
@Ben-sv9op Год назад
I was referring to the soft wash yellow hose what brand or company is that I’d like to buy ?
@jeffhenry8937
@jeffhenry8937 3 года назад
Does your comet Recirculate at all times when on the Trigger and when your not on the trigger
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
I believe it bypasses a little even while on the trigger. This would be determined by the settings you have your regulator on. And yes when you are not on the trigger the pump recirculates.
@washlife5238
@washlife5238 3 года назад
On the bypass line did you tee it back into the 1 inch inlet?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
No, the bypass hose goes back to the proportioner (red 1/2 hose in the video).
@jamescporter87
@jamescporter87 Год назад
How did you run your by pass hose? Did you run the by pass back to you SH tank? Or did you run it back to you proportioner some how? I am trying to run my systems as efficiently as possible and not wast my mix when I have to let off the trigger.
@deanweingarth5120
@deanweingarth5120 Год назад
I'm wondering the same. From what I gather you tee into the supply line between the proportioner and the pump. I'd like this gentleman cto chime in and confirm. Ive also come across another guy saying to put a check valve before the tee so there's no pressure drops creating agitation between the proportioner and the tee.
@premierpowerwashing6634
@premierpowerwashing6634 2 года назад
Hey man. My 1" flex hose with filter in my tank like to float up. How did you get yours to stay at the bottom?
@peternguyen4047
@peternguyen4047 Год назад
Hose reel manifold? I have a 1/2, does that work?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Yes that will work, make sure it’s a high quality stainless steal swivel.
@brandonchristensen4977
@brandonchristensen4977 Год назад
Hey matt, i am in your area and just started a pressure washing business, i have a very similar set up but i am so confused on how to plum everything up. Would you be able to assist?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Shoot me a text (941) 500-3148
@TexasWatchman
@TexasWatchman 3 года назад
Can't find the hose. Can you provide more info? Link? Also, what size is the hose reel manifold? I'm assuming it's stainless? I would really appreciate the info.
@FlashTechEngineering
@FlashTechEngineering 2 года назад
Hi bro, the bypass 25 feet line when off the gun , does the water flow back to your buffer water supply tank?? Thanks David
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
If your system is set up just like the one in the video, then no it does not. It circulates back through the proportioner and then back through the pump. Your bypass hose goes back to the proportioner so it will not go back to your buffer tank.
@scottruch674
@scottruch674 3 года назад
Yo , did you run your comet off your powerwashers battery or did you use a separate battery? ?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
I gave it its own battery but you can connect it to the same battery as your power washer. Whatever you prefer. If you have a heavy duty deep cycle battery for your washer just connect it to that
@8076alina
@8076alina Год назад
so no need for a 12v pump with a gas roof pump?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Nope
@deanweingarth5120
@deanweingarth5120 Год назад
Still researching. What port size is 3 way shutoff are you using? I'm also a little confused on the crush proof hose size. Are all your crush proof hoses 3/4" or 1"
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Guys are using 3/4” or 1”
@johnofalltrades7421
@johnofalltrades7421 3 года назад
Sick vid
@michaelricklefs1379
@michaelricklefs1379 3 года назад
Where are the uni seals available through?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
www.marinedepot.com/uniseal-flexible-tank-adapter-bulkhead-3-4-inch
@honki790
@honki790 3 года назад
What size are the mixing valves? 1/2? or are they 1”
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
1”
@rexshin7671
@rexshin7671 2 месяца назад
How’s the p40 pump? Are you happy with it?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Месяц назад
@@rexshin7671 Still enjoy it very much
@ronkemberling4267
@ronkemberling4267 2 года назад
I would disagree with you on the bypass hose. You REALLY need a bypass tank. Going back to the proportioner does not let the pressure release.
@jeffs53
@jeffs53 3 года назад
I noticed the pump isn't self priming. Do you have any issues getting the flow going?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
The pump self primes, we have never had an issue with priming.
@josegutierrez9113
@josegutierrez9113 3 года назад
Yes the honda Engine what specific Engine is this and how much cost just the Engine
@andrehawk100
@andrehawk100 2 года назад
do you mind me asking what it cost to build your system ?
@VAPressureWash
@VAPressureWash Год назад
Does Comet offer a P40 pressure gauge adapter so we know how much psi it’s running at?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Unnecessary, just another thing to break and you’re only working with a range of about 200PSI. Don’t over complicate it
@pristineexteriorcleaningse5691
@pristineexteriorcleaningse5691 2 года назад
You have no problems running 3/4 in on water line? I’m assuming you went 3/4 cause you gotta crack the 1in?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
No problems at all
@hicksd34
@hicksd34 Год назад
How did you hook up your gun? Hose clamps?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Месяц назад
@@hicksd34 crimped end with threads
@williammata6019
@williammata6019 7 месяцев назад
Have you had any issues with the p40?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 7 месяцев назад
Just normal wear and tear repairs. Nothing crazy that would stop me from recommending it. It is still a great system and probably one of the best on the market in my opinion
@williammata6019
@williammata6019 7 месяцев назад
@@bluecollarentrepreneur3377 thank you 🙏
@scottruch674
@scottruch674 3 года назад
Hey Matt, how many feet of 5/8 hose you running?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
275 feet
@ts3290
@ts3290 2 года назад
On your Surfactant. Are you pumping that straight or is it deluded?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
Depends On what you’re using. We use thick soap so it’s always diluted.
@cleanritepressurecleaning4076
@cleanritepressurecleaning4076 3 года назад
How’s the P40 working at this point? Any major issues?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
Still works like a charm every day. 2-3 jobs per day no issues at all
@cleanritepressurecleaning4076
@cleanritepressurecleaning4076 3 года назад
@@bluecollarentrepreneur3377 nice, thanks for the reply.
@Ben-sv9op
@Ben-sv9op Год назад
What’s the name of hose I want to buy ? Also I don’t get the bypass hose where does it go to or it’s just a closed Circle loop ?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
What hose are you referring to? And yes the bypass just makes a closed loop.
@Ben-sv9op
@Ben-sv9op Год назад
@@bluecollarentrepreneur3377 why can’t you have the bypass hose dropped in the chemical tank when spraying sh . and then when you’re washing with fresh water just have it runoff the truck…
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
@@Ben-sv9op this would not work if you are using a chemical mixing valve system. For example let’s say you’re using a 1% solution to clean a house, which is a very light solution. If you by pass back to your chemical tank you’re going to be diluting it with a ton of water. Also the whole point of the remote valve system to switch back and forth is to make your life easier and speed up your cleaning time. If you have to walk back to the truck to switch your bypass hose then you completely defeat the entire purpose of a system like this.
@Ben-sv9op
@Ben-sv9op Год назад
@@bluecollarentrepreneur3377 Absolutely you’re correct thank you for your time and response
@dcsc4895
@dcsc4895 2 года назад
Is this a better pump than the AR 45?
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
Yes, in my opinion it is far superior
@dcsc4895
@dcsc4895 2 года назад
@@bluecollarentrepreneur3377 ty sir
@williambrown9345
@williambrown9345 3 года назад
Where can I buy the return at
@williambrown9345
@williambrown9345 3 года назад
Where can I buy the return hose at
@mattsievering8794
@mattsievering8794 2 года назад
I just got a chemical sprayer. It has a Honda gx160 and a comet mp-30gr. Max psi is 400. I'm new to this. Is there a way to pull the "chemicals" from a separate tank so I won't has to introduce them to the pump. The pump is 700$ and don't want to have early failure bc of chemicals
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 2 года назад
Not that I know of. Every system I know pumps the chemicals through the pump. If you have the right type of pump and take care of it you will be ok.
@cornerstonephysicaltherapy2876
@cornerstonephysicaltherapy2876 3 года назад
can you run a 1/2" hose on your reel? I see you have 5/8.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
You sure can. However you might see a slight decrease in water flow and overall distance. However I know several people that run 1/2 inch because it is easier to use.
@HumbleBeast777
@HumbleBeast777 3 года назад
@@bluecollarentrepreneur3377 I thought your flow would be better, the bigger the hose? Like the output port on P40 is 3/4", why not run a 3/4" hose for it if it allows for that size? Wouldn't it be the most GPM possible.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
@@HumbleBeast777 yes in theory the bigger the hose you run the more flow you will get. That is why we run 5/8 instead of 1/2. However I personally think 3/4 is excessive and wouldn’t be fun to drag around all day. But remember at the end of the day if you run 3/4 but run it through a standard reel you aren’t going to gain much flow because the restriction of the swivel. So if you do want 3/4 flow you will need a 1” reel and swivel.
@HumbleBeast777
@HumbleBeast777 3 года назад
@@bluecollarentrepreneur3377 okay, good to know. I think 5/8 is the way to go then. thanks!
@wehttamgtrekce
@wehttamgtrekce Год назад
It would be great if you could diagram it out and have it on your website.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
Sorry I didn’t see your comment sooner, so you still need help with this?
@wehttamgtrekce
@wehttamgtrekce Год назад
@@bluecollarentrepreneur3377 Thanks, but no I don’t, I just thought that a diagram along with your video would be a real help to anyone working on a similar setup. Love the name of your channel btw.
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
@@wehttamgtrekce that’s is a good idea. Thank you
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 Год назад
@@wehttamgtrekce any topic requests for more videos?
@jesusson3475
@jesusson3475 2 года назад
This is way too confusing I got lost two minutes in i’m a have to watch this at .25 speed 😂
@2Nicemrniceguy
@2Nicemrniceguy 3 года назад
P40 is bad news
@bluecollarentrepreneur3377
@bluecollarentrepreneur3377 3 года назад
Why? Nearly 300 hours on our unit with no issues.
Далее
ВОТ ЧТО МЫ КУПИЛИ НА ALIEXPRESS
11:28
Просмотров 427 тыс.
How To Prime A Gas Soft Wash System
12:57
Просмотров 6 тыс.
High Flow Mixer - P40 - AR45 Plumbing Walkthrough
5:32
Proportioner Build & Test
16:12
Просмотров 46 тыс.
Comet P40 Oil Change and Update
9:39
Просмотров 5 тыс.
Comet P40 demonstration
5:45
Просмотров 10 тыс.
Water Boss VS Red Gun
11:48
Просмотров 8 тыс.
How To Operate A Blend Manifold | Soft Wash System
9:43