How To Repair a Broken PVC Water Main - DIY! 

Randall Wingett
Подписаться 78 тыс.
Просмотров 213 тыс.
50% 1

"The simplest solution is not always the best, and "haste makes waste" aptly describe the first two attempts to repair the broken 3/4" PVC water main pipe leading to our house. In retrospect, I should have done this repair myself! That said, I learned a lot from the mistakes made by Joe, an independent contractor who did many of our home improvements. And Joe quickly responded to my call for help when I broke the water main pipe, and when mistakes were made, he followed through with fixing it right. I hope that you find this video both entertaining and informative, and that you will now know what not to do should you need to repair a PVC water pipe.

Опубликовано:

 

30 авг 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 62   
@DanielKing2014
@DanielKing2014 2 года назад
The drying time for that glue is 2 hours to 2:30 hours NOT 15 minutes.
@Jazziegirltoo
@Jazziegirltoo 3 года назад
THANKS!! THIS is EXACTLY what I needed!!! I've done it B4, but needed a brush up! This was perfect!! With the reminder to let the coupler set up!! Great that you showed how sometimes something does go wrong.
@Hajjat
@Hajjat 2 года назад
This is very useful! I just moved to a new house and discovered that the main sprinkler pipe to backyard is broken. When I turned on the sprinkler on for a few minutes it gushed out about 280 gallons of water (I installed a meter sensor which shows consumption minutes by minute)!! I was shocked. Time to repair it.
@condor5635
@condor5635 2 года назад
Only good solution here is to use couplers and not compression couplers they have rubber parts that wear out. Get enough room in the pipe you can bend enough to get a normal coupler on it securely
@arcadion448
@arcadion448 4 года назад
Proper way to glue PVC (or CPVC): 1) Clean with rag - this removes any dirt or oil. 2) Use cleaner (optional - but this will remove any paint etchings by the manufacturer and let the primer/glue do a better job. You're a DIY, take the extra step. Lazy handymen (Joe) and lazy plumbers skip this for profit - which is stupid cause it literally takes extra 5s and $7 to buy the whole bottle). 3) Use primer and cement (aka glue) 4) Turn 1/4 when connecting and hold for 30s (Joe forgot to hold). 5) Wait for cement's recommendation before turning on water.
@DarkpawTheWolf
@DarkpawTheWolf 4 года назад
^^^ THIS is the correct way to connect PVC.
@luisbolanos8393
@luisbolanos8393 3 года назад
What kind of cleaner?
@arcadion448
@arcadion448 3 года назад
@@luisbolanos8393, there are PVC Cleaners you can find in a hardware store, they should be in the same section.
@flawedrevolver967
@flawedrevolver967 4 года назад
Thank you for this video 👍
@ronharris91
@ronharris91 4 года назад
Joe's gonna be back about another 50 more times.
@Agrofind6161
@Agrofind6161 Год назад
❤ ❤ Great ! thank you for sharing. Hope to accompany you in the future🙏🙏🙏🙏
@petemarron6677
@petemarron6677 3 года назад
Cool vid, I've had good luck with medium gray cement, two hour set up time
@projectfreedom9510
@projectfreedom9510 3 года назад
mine has this rubber that is running into the pvc pipe to the rainbird system. I leaked right at the compression fitting on the rubber side of the hose. I already replaced the entire front yard with new hose that did last 10 years in Arizona. There is a section though that runs under the concrete that turns into pvc
@crazyperson5222
@crazyperson5222 3 года назад
My pvc 160 psi rated main burst from cold weather so it has a Crack. I cut out the damaged part and it was so small so I only installed a pvc compression coupling and I see no leaks anymore. So is this a permanent fix? Am I good?
@user-vf7vg8ku9z
@user-vf7vg8ku9z Год назад
I'm in the process of fixing my main water line, I went to home depot to buy the flexible PVC coupling, and on the label it states, not to be use in continues water pressure line. Moving to option #2. thanks
@paulmayfield9709
@paulmayfield9709 3 года назад
Well you are supposed to prime and glue both sides. I would guess you will be back to fix it in no time if you use a repair coupling like that , just because it’s 4” long doesn’t mean to take out 3” you still want them close together. Also when you put it together on the side of the ditch will come loose you barely put it on that side the dirt when settles will pull it right off. If you had the full length in there it would have a better chance. Now what I would use for a underground fitting for that is use a Ford coupling. It’s the same as the repair coupling except it’s brass and has a set screw on both ides to keep it from blowing apart. About 30 bucks or so a fitting but better then digging it back up
@jessecarcamo1802
@jessecarcamo1802 Год назад
What cutter did you use?
@VisionsTruth
@VisionsTruth 15 дней назад
Those compression fittings aren't meant for continuous pressure either. They have rubber gaskets that will wear out and need to be replaced. Better to dig further back to get a longer piece so you can bend it and use couplers.
@blazezoolander7473
@blazezoolander7473 10 месяцев назад
I always open a few taps first so the pipe fix is not getting 100% pressure when i turn the water back on.
@jswarpaint6215
@jswarpaint6215 2 года назад
The constant 15 min. cure time in this video may be bogus. - - On the cement I use - it reads 15 min. for "good handling strength" and 2 hours !!! cure time BEFORE !!! Pressure testing at 60 degrees F or above 60 degrees if below 60 allow MORE TIME !!! Pressure testing means allowing WATER to be in the pipes which causes water pressure to be present. Furthermore, your suppose to when you put the pieces together after Priming AND Gluing when you put them together you need to turn it 1/4 turn AND hold it firmly for 30 seconds. (so then after doing this you wait 15 min. minimal before you even touch it ) Then wait 2 hours minimal before running water through it assuming its 60 degrees or higher. ALL OF THIS INFO IS WRITTEN PLAINLY ON THE CANS OF CEMENT AND PRIMER !!!!
@Honestandtruth
@Honestandtruth 2 года назад
Why not used the Compression Compling on both sides...????
@jvazquez53
@jvazquez53 2 года назад
Aren't you supposed to put the blue glue on both pieces?
@Wildcat5181
@Wildcat5181 4 года назад
The title should have been, "How to repeatedly repair a PVC pipe break." I don't think those couplings are for use in inaccessible locations such as underground, in walls, in, or under slabs.
@stumpy7777
@stumpy7777 3 года назад
Why not use 2 compression couplings. Dont put primer on the coupling side it softens the pipe and will eat the rubber.
@Hever73
@Hever73 4 года назад
You suppose to put plenty of glue on both fittings that's why you had a leak!
@brianaizawa1541
@brianaizawa1541 4 года назад
Would of used a compression coupling again.
@arcadion448
@arcadion448 4 года назад
Nope - he forgot to hold for 30s AND wait for cement's recommendation before turning on water.
@maxchartier
@maxchartier 4 года назад
i think it would have been better to glue in some 90 degree fittings, or to use a pvc slip fitting on one end, not sure if that compression fitting is suitable for burial.
@maxchartier
@maxchartier 4 года назад
thanks for the video anyway, good luck.
@brianaizawa1541
@brianaizawa1541 4 года назад
no the compression coupling is suitable. not a slip fix.
@arcadion448
@arcadion448 4 года назад
He didn't even need 90s, damn thing "looked" straight enough for two couplers and a straight line.
@denniskazich7559
@denniskazich7559 Год назад
I've used the coupler before where it was accessible. Never buried. Pipe should have been closer together before installing coupler with rubber washers. Could have used glue connectors on both sides. There was enough room to snake pipe in there and forget about it.
@billsmith987
@billsmith987 3 года назад
Didn't put any glue on the male side.
@jacknife10000
@jacknife10000 Год назад
Only works if your pipe is laid straight, mine is broken and the two ends are at an angle so this will eventually leak again
@rolac6109
@rolac6109 4 года назад
I would let it dry without turning the water for a least 2 hours on that blue glue
@Hever73
@Hever73 4 года назад
45 minutes depending on the weather
@brianaizawa1541
@brianaizawa1541 4 года назад
On the second leak he should of used another compression coupling, no glueing needed.
@br549times3
@br549times3 2 года назад
Not sure why you bothered with the not suitable flexible tubing.
@ryangilchrist5319
@ryangilchrist5319 3 года назад
I’m an amateur and know this is a “how not to” video.
@SherifSpeedy
@SherifSpeedy 3 года назад
why do they put the pipes so deep like that!!! Its gets annoying trying to dig for the pipe to find it!
@tomz808
@tomz808 3 года назад
A water pipeline must be below the frost line (varies with location, about 3-4 feet) so it doesn't freeze and burst, because water expands when freezes.
@AndyC1
@AndyC1 2 года назад
Is PVC the best for the main line. Should galvanized steel be used for the main line?
@whoknows930
@whoknows930 2 года назад
No pvc
@ToThePoint690
@ToThePoint690 2 года назад
Thanks It safe me between $600-1500
@Honestandtruth
@Honestandtruth 2 года назад
It's Better Let it sits for 1-hour or so before turning w Water back On.
@acastillo529ac
@acastillo529ac 3 года назад
That primer will eat up that rubber gasket over time
@Jazziegirltoo
@Jazziegirltoo 3 года назад
NOT using on the gasket inline coupler. Only on the 3/4" PVC coupler.
@gman5986
@gman5986 3 года назад
My experienced plumber said to never use that Shite Christy's blue garbage. He said it always fails!
@ignaciohernandez8130
@ignaciohernandez8130 4 года назад
not an expert. but pretty sure ur suppose to use cpvc pipe for water lines.
@MrC9Oh3
@MrC9Oh3 4 года назад
Lol cpvc is for hot water only
@doylee469
@doylee469 3 года назад
Sean what? Jeeez where did you even get that wrong info from?
@MrC9Oh3
@MrC9Oh3 3 года назад
@@doylee469 thats all its used for in my area
@doylee469
@doylee469 3 года назад
Sean i had it for hot and cold water for awhile.. it may be shit pipe but it served me for a solid 8 years and who knows how long for the last owners. Only got rid of it because I got brow beat by plumbers to replace it.
@TimberedSplash
@TimberedSplash 3 года назад
CPVC is for hot water. PVC is the main source of pipe used before the hot water heater in a home. Then from the hot water heater CPVC is used throughout the home. Also, in any new home construction I have seen, I have never seen CPVC used to lay new water lines in the ground. It’s always PVC. Doesn’t mean CPVC can’t be used. The problem with using CPVC for in ground/before the home application is that it would be pretty damn expensive.
@ynot3778
@ynot3778 3 года назад
Guy just stop 3x to fix !! Please you making a fool of yourself’s . Call a plumber
@johnmartinez9220
@johnmartinez9220 3 года назад
It's a tutorial dude
@dumpsterfire6351
@dumpsterfire6351 Год назад
Lays in dirt…your fired
Далее
How to fix a Broken pvc pipe
8:32
Просмотров 38 тыс.
Копия iPhone с WildBerries
01:00
Просмотров 614 тыс.
How to Shut Water Off to Your House...MUST HAVE TOOL!
5:59
Water Pipe Fix -- DIY main waterline repair video
9:31
DIY PVC Pipe Repair Fitting!
7:13
Просмотров 218 тыс.
How to repair a cracked sprinkler pipe
10:22
Просмотров 304 тыс.