How to replace the combination gas valve 

grayfurnaceman
Подписаться 158 тыс.
Просмотров 194 тыс.
50% 1

This is a long one. It covers all the steps to replace a combination gas valve. It should also cover replacing newer valves without a pilot light. This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. If you have suggestions or comments they are welcome.
If you are a homeowner looking to repair your own appliance, understand that the voltages can be lethal, the fuels are highly flammable and high pressures are used. Know your limits.

Опубликовано:

 

7 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 154   
@powerpooch2000
@powerpooch2000 3 года назад
Best clearest voice and enunciation in the biz.
@fredbraid818
@fredbraid818 Год назад
Love the detail and the practical information just laid out there. Now I have much less chance of dying in a fireball of my own making Seriously, I truly appreciate the emphasis on safety as natural gas is not something you can afford to make a mistake with
@rockstertx
@rockstertx 5 лет назад
your knowledge is definitely well shown throughout the install... should make all of us amateurs think twice about diy installs.
@michaeldempster7963
@michaeldempster7963 2 года назад
Thanks, sir, you are an excellent teacher! As someone else has said, your thoroughness should incline us amateurs to hesitate attempting this kind of repair!
@nostrinick
@nostrinick 8 лет назад
Followed your instructions and now have new combo valve installed and furnace running like a champ. Thanks for the vid.
@grayfurnaceman
@grayfurnaceman 8 лет назад
Welcome GFM
@st.charlesstreet9876
@st.charlesstreet9876 3 года назад
Your whole channel is invaluable! Thanks for this posting!
@hvacguru-Kansas
@hvacguru-Kansas 11 месяцев назад
Late to the party (commenting on 9 year old video). A lot of detail for a standing pilot furnace. Much needed for today's service techs. Trade schools do not teach this stuff well enough. All of our young techs are clueless when they see a standing pilot appliance. A couple of things I wished you would have covered: 1. The ECO circuit was not connected to the old valve you removed and you did not connect the circuit to your new valve. The manufacturer put that safety in the furnace and it is not our job to decide that safety should be taken out (without a document from the manufacturer saying that it can be removed if you upgrade to a redundant valve). It is troubling to me when any furnace safety is ignored. 2. Roll out switch bracket was bent out of position and should have been put back to proper position. 3. I like to check and adjust the flame with the roll-out shield in place because the combustion air pattern changes with it installed. Not very easy to video the flames with it in place so I can see why you didn't have it installed. Other than that, good job GFM!!😀
@DOLRED
@DOLRED 6 лет назад
Thanks for the video. Had a stuck gas valve once--"On" on the gas boiler (1992). In the 1980s had a leak at the pilot line/valve body (As you describe). Took considerable effort to fix it and singed my eyebrows in doing so!!
@grayfurnaceman
@grayfurnaceman 6 лет назад
Welcome GFM
@randymarcell
@randymarcell 6 лет назад
This is an excellent training video.It is clear, thorough and easy to follow.
@grayfurnaceman
@grayfurnaceman 6 лет назад
Thanks for the support. GFM
@dcrickerson9775
@dcrickerson9775 10 лет назад
Great video GFM, just completed the gas furnace section of my book so this video and your other videos are a great help and very appreciated. Thank you for sharing.
@jewdali1
@jewdali1 7 лет назад
Good explaination based on hands-on experience . Very good competent man .
@grayfurnaceman
@grayfurnaceman 7 лет назад
Thanks for the support. GFM
@steveg5576
@steveg5576 10 лет назад
Excellent vid ! Clocking the meter that was neat. Thanks for your help this past winter fixing my gas pack using your videos.
@anthonyhitchings1051
@anthonyhitchings1051 3 года назад
thanks so much for the comprehensive video
@zappa916
@zappa916 9 лет назад
ive learnt so much about gas furnaces in 27 mins than I have reading 3 days of manuals.
@grayfurnaceman
@grayfurnaceman 9 лет назад
AngeV2 Glad I could help.GFM
@dhealy3154
@dhealy3154 2 года назад
Thank you. Awesome info. Step by step
@hannarye
@hannarye 10 лет назад
Awesome vid. I enjoy working on furnaces.
@raymondflores4183
@raymondflores4183 8 лет назад
yes you covered it thank you for all your input.
@Forge5894
@Forge5894 7 лет назад
Excellent video! Thank you for posting it GFM!
@grayfurnaceman
@grayfurnaceman 7 лет назад
Welcome GFM
@captlarry-3525
@captlarry-3525 2 года назад
I HAD A WELDER MIG WELD A WALL HEATER WITH A CRACKED FLAME TUBE...WHICH HAS LASTED WELL FOR YEARS. BUT IF A NEW PART IS AVAILABLE..USE IT !
@Rayram555
@Rayram555 5 лет назад
I enjoyed this lesson . Thank you
@grayfurnaceman
@grayfurnaceman 5 лет назад
Welcome GFM
@dieselhater
@dieselhater 10 лет назад
great video as usual, I had this same furnace last week where the roll out switch over the burners tripped. Draft was ok but alot of heat over the burners. I had to shut the furnace down. Very old furnace they decided to go with a new one
@raminla2000
@raminla2000 8 лет назад
Thanks greyfurnaceman I really appreciate this, I needed this teaching video to help me obtain NATE Cert. I also was trying to figure out issue I had with pre-ignition issue, I hope you can provide insight to what may cause this other than ,I already checked for misaligned burners and there is a draft (air) filtrating the burn area.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+raminla2000 Do you mean delayed ignition? GFM
@alfredoguerrero8596
@alfredoguerrero8596 3 года назад
Great video that helped a lot thank you
@grayfurnaceman
@grayfurnaceman 3 года назад
Welcome GFM
@gogaton
@gogaton 7 лет назад
Very practical video, thanks.
@grayfurnaceman
@grayfurnaceman 7 лет назад
Welcome GFM
@gogaton
@gogaton 7 лет назад
Again, awesome video
@williamprovencher2220
@williamprovencher2220 Месяц назад
awesome
@johndoe-wt4ui
@johndoe-wt4ui 4 года назад
Where’s the link for the other video Gary ? Great video btw!
@deanmartin1966
@deanmartin1966 10 лет назад
Great video. Thanks for sharing.
@geojor
@geojor 9 лет назад
appreciate your expertise...
@afxma
@afxma 7 лет назад
Thank you!
@lordelrond5264
@lordelrond5264 8 лет назад
Great video. Thank You
@grayfurnaceman
@grayfurnaceman 8 лет назад
Welcome GFM
@shodanxx
@shodanxx 10 лет назад
Wow, very informative, thank you very much !
@kimclarke6262
@kimclarke6262 7 лет назад
Sabi
@kimclarke6262
@kimclarke6262 7 лет назад
Dr sabi
@kimclarke6262
@kimclarke6262 7 лет назад
Dr sabe
@kcc294
@kcc294 4 года назад
You need a grayfurnaceman shirt that says DONT GET LOONEY TOON
@grayfurnaceman
@grayfurnaceman 4 года назад
Good Idea. GFM
@LinZhang1236
@LinZhang1236 6 лет назад
Great Video
@tombouie
@tombouie 9 месяцев назад
Thks
@Robnord1
@Robnord1 10 лет назад
Great video ! I learned several things, even though I have done some of these valve replacements before. I've not seen one with adjustment for manifold pressure. Maybe I didn't know what I was looking at, or maybe the LP burning mobile home furnaces I service (usually single burner) don't have adjuster. I'll look closely on future jobs. I will also start testing limit switches...never have done that. Have you ever tried a flare nut wrench to tweak leaking pilot tubing compression fittings ? I have an old 3/8 & 7/16" Lisle six point flare nut wrench (for automotive fuel & brake line fittings) which I ground one side (they come rounded a little) flat...so it will slide over nut just a bit more. Works great. Little extra bit of torque available with these almost always stops leakage for me, no pipe goop needed. Thanks for the video , much appreciated Rob
@Alpha-ms9nj
@Alpha-ms9nj 2 года назад
I moved into an old Mobile home with an old Duotherm 52,000 btu NG/LPG furnace. It is running on LPG. Can't afford to upgrade to a newer safer unit. I was told It hasn't been used for 16 years since the owner passed away. I had to find a source for information on these relic standing pilot ones and this channel is most informative. Like going to a tech school at home. I have an issue tho with a slight propane smell. It smells like a small leak but only noticeable when my propane tank is low. I've done the soap and bubble spray test, with gas valve on and furnace running/not running. It has on old White Rogers valve. I put my nose close to the on/off/pilot button and it smells like that is where it's coming from, but no bubbles when sprayed. Do those or any control valve have O-rings/gaskets that wear out internally and not sealing? Or can the issue be a gas in/out pressure problem? I have a little bag with the NG orifice fitting inside of it so I'm assuming it has the LPG orifice installed. I appreciate your great channel and any pointers thank you.
@grayfurnaceman
@grayfurnaceman 2 года назад
Gas valves sometimes leak at the knob where the shaft enters the casting. Pretty tough to determine unless you are using an electronic detector. GFM
@Alpha-ms9nj
@Alpha-ms9nj 2 года назад
@@grayfurnaceman - Yes I heard you mention that and how the soap test wont work on the knob in the video. When I put my face close to the valve and did the nose test, it confirmed it for sure. Now I'm looking online for a modern replacement. It's obviously discontinued by White Rogers and it's funky cause the gas inlet is at 12 o'clock top position and exit is on the side at 9 o'clock smh. I'm going to have to re-pipe a new one as it will be a straight through style. Their website recognizes the old model number but doesn't offer any specs or comparable replacement. The old one is a 36B12Z-201. I'm only guessing that their 36C03-300 OR 333 may work out but I may have to call them to be sure.
@grayfurnaceman
@grayfurnaceman 2 года назад
@@Alpha-ms9nj The 333 has side outlets that may make the install easier. GFM
@Alpha-ms9nj
@Alpha-ms9nj 2 года назад
@@grayfurnaceman - Huh..Is that what they mean by tapped and plugged? Has other inlet/outlet options? BTW, Thank you for the help and guidance. Merry Christmas to you and yours.
@grayfurnaceman
@grayfurnaceman 2 года назад
@@Alpha-ms9nj It is. I believe that valve has both right and left outlet in addition to the straight thru option. Merry Christmas GFM
@T1374
@T1374 Год назад
I have an older 1970s payne day and night furnace and the burners don't fire up. I don't have the money to replace the furnace so I'm trying to find a replacement valve valve for it.
@grayfurnaceman
@grayfurnaceman Год назад
If it has a pilot, a general replacement valve should work. GFM
@T1374
@T1374 Год назад
@@grayfurnaceman thanks. The original valve has a pinned-in solenoid assembly with 2 connectors. Black/Yellow to one side and Black to the other side. What does that mean? Also the pilot is part of a 2 wire assembly, a thermopile I think? Not sure how all the wiring is going to rout on the new replacement.
@grayfurnaceman
@grayfurnaceman Год назад
@@T1374 If you can send pics, that may help. Send to Grayfurnaceman@gmail.com GFM
@T1374
@T1374 Год назад
@@grayfurnaceman Thank you. I'll send some out to you tomorrow.
@dominiquepierre916
@dominiquepierre916 2 года назад
Very great video I have question ;for changing gas valve ;should I change old pilot tube orvi can re-use it?
@grayfurnaceman
@grayfurnaceman 2 года назад
If it is gas tight when finished, use the old one. GFM
@dominiquepierre916
@dominiquepierre916 2 года назад
@@grayfurnaceman Thank you very much my friend. You teach very well. Please continue .
@EurekaRecycler
@EurekaRecycler 4 года назад
When the fan comes on and the flames waver does this always mean the heat ex-changer is cracked? Thank you
@river4888
@river4888 8 лет назад
Good information and your videos are easy to understand. My problem is the gas valve is making a buzzing sound and I have determined the solenoid is bad. It's a Essex gas valve SX242NSPR/ 242-111151-3152. I found a used one but the number is SX242NS / 242-111121-1101. They look identical but I don't know what the SPR in my bad valve designates. Any advice on compatibility would be great.
@mechanicwarrior20
@mechanicwarrior20 10 лет назад
Well Done
@grayfurnaceman
@grayfurnaceman 7 лет назад
Thanks for the support. GFM
@shawnascott8887
@shawnascott8887 7 лет назад
i have a york borg warner furnace and i need to order a new combination gas control valve but i cant seem to find out if i can use a universal valve. the old valve is an essex TF-155 210-221000-1332A i found on used on ebay but i was trying to find a better deal
@anthonyhitchings1051
@anthonyhitchings1051 2 года назад
or use a tubing wrench for that small fitting
@jeffreywolf5235
@jeffreywolf5235 Год назад
I would love to know what tool you use to get those reducers into the new valve body? Some sort of inside tightening?
@grayfurnaceman
@grayfurnaceman Год назад
My fingers. You simply screw it onto the male end of the pipe, then screw into the valve and tighten. Of course with pipe dope on all male surfaces. GFM
@thomasbutler-k6c
@thomasbutler-k6c Год назад
Shouldn't there be a sediment trap on the gas line?
@grayfurnaceman
@grayfurnaceman Год назад
There should be. The furnace shown is a test mule, not an operating furnace. GFM
@mark.r8900
@mark.r8900 Год назад
Hi, I have a lennox gas valve 73w17. There are two wires connected to it. One yellow wire and one orange wire. Does it matter which wire goes where on the gas valve? Lots of videos have it orange ontop and yellow at bottom. If I have it the other way with yellow ontop and orange at bottom. Will the valve function the same? Thanks
@grayfurnaceman
@grayfurnaceman Год назад
Any way will do. It is not polarity sensitive. GFM
@mark.r8900
@mark.r8900 Год назад
Thank you
@johndoe-wt4ui
@johndoe-wt4ui 4 года назад
What’s the leak detector you’re using?
@russm1757
@russm1757 7 лет назад
Great video, question, what about ending with a flue gas analysis?? Russ Motchell
@grayfurnaceman
@grayfurnaceman 7 лет назад
I virtually never do a flue gas analysis on a gas designed furnace. If the manifold pressure and orifices are correct, the only adjustments for efficiency would be the primary air if it is adjustable. From doing such tests, I have found that there is little I can do to increase efficiency, and in some cases, the efficiency may show higher with by increasing manifold pressure beyond manufacturer specs. In my jurisdiction, I cannot set the manifold pressure above or below the manufacturer's specs. I will do more on this in the future. GFM
@russm1757
@russm1757 7 лет назад
thanks. Great job with the videos, really enjoy the way you explain everything your doing. makes it easier to understand. Russ
@melvin292
@melvin292 7 лет назад
no. 1 son works for a retailer with HVAC service. They give him 20 minutes total to do this very repair. Your opinion; is that enough time?
@grayfurnaceman
@grayfurnaceman 7 лет назад
I was the fastest service tech at my company with10 to 14 techs. On site time was a minimum of 1 hr with more likely 1.5. GFM
@melvin292
@melvin292 7 лет назад
grayfurnaceman I agree. I think son should work for you. 😂
@michaelkranz2529
@michaelkranz2529 7 лет назад
Don't forget to tell them that the reducer bushing is directional too .
@grayfurnaceman
@grayfurnaceman 7 лет назад
Good thought. GFM
@bubbajohn6997
@bubbajohn6997 4 года назад
Hello, I have an Royal gas wall furnace from the 50's. It works perfect, but is worrisome because the pilot continues to flow gas even when the flame is not lit. Apparently it was made that way. Would it be possible to retrofit a control valve with those safety features?
@grayfurnaceman
@grayfurnaceman 4 года назад
Yes, and I would do so. That appliance is unsafe. A combination gas valve will replace your entire gas chain. GFM
@bubbajohn6997
@bubbajohn6997 4 года назад
@@grayfurnaceman Thank you so much for the quick reply. I'll call someone tomorrow to see about replacement.
@mikhail6518
@mikhail6518 5 лет назад
To the right of the pressure regulator you can see the pressure regulator vent (it's plugged up with what seems to be a metallic plug, and sits just above the tap that you used to measure the gas pressure). What is the point of this vent? Should there be a vent line going from the valve?
@grayfurnaceman
@grayfurnaceman 5 лет назад
The vent tap is not really plugged. The cap does not seal. The vent is to place the regulator in the same pressure area as the burners. If this furnace had a sealed combustion chamber, there would be a vent line to the combustion chamber. GFM
@mikhail6518
@mikhail6518 5 лет назад
@@grayfurnaceman thank you for clarifying that.
@tommylauj
@tommylauj 5 лет назад
Where would I go to buy a valve like that? Mine is probably bad. My pilot light is on but when you set to auto the furnace doesn’t engage. When I set to On the furnace and fan starts but blows cool air only
@grayfurnaceman
@grayfurnaceman 5 лет назад
There are a number of problems that this could be. If there is no voltage to the valve an a call for heat, the valve is ok. GFM
@chiraq6614
@chiraq6614 5 лет назад
Were did u get the valve gas from?
@alankuncel2545
@alankuncel2545 4 года назад
Water pump pliers? Channel locks...maybe. Where I come come from, it's called a mexican speed wrench.
@grayfurnaceman
@grayfurnaceman 4 года назад
Well, I guess you could use a 3" end wrench. lol GFM
@coach3958
@coach3958 Год назад
What controls the delay in the blower coming on?
@grayfurnaceman
@grayfurnaceman Год назад
Most furnaces of this age have a heat operated fan switch. GFM
@coach3958
@coach3958 Год назад
@@grayfurnaceman thanks, I looked further in your videos and found the one about fan limit switch. I saw it on the furnace but thought it was a capacitor. I will check it. Its probably my culprit. I subscribed to your channel. Your are awsome and a grest help for me understanding these units
@coach3958
@coach3958 Год назад
@@grayfurnaceman Im replacing the original gas valve, a Honeywell VR8000C, the new one looks quite different. What terminal does the wire go on, the TH or TR?
@grayfurnaceman
@grayfurnaceman Год назад
@@coach3958 If you mean the wire from the limit switch, it would be TH. GFM
@IlyaStavinsky
@IlyaStavinsky 4 года назад
One question Gray. What tape or thread dope I can use to stop gas leak from a connection of termocouple with gas valve ? thank you
@grayfurnaceman
@grayfurnaceman 4 года назад
The thermocouple threaded connection to the gas valve should not be sealed in any way. Are you sure you are not thinking about the pilot gas tubing connection? GFM
@lamontgarrison3296
@lamontgarrison3296 3 года назад
My hvac tech put a new combo valve with the thermocouple and it will not take lot more that 5 more minutes any suggestions it’s an old American standard
@grayfurnaceman
@grayfurnaceman 3 года назад
You are going to have to try that again. I did not understand. GFM
@lamontgarrison3296
@lamontgarrison3296 3 года назад
@@grayfurnaceman we blew compressed air through the pilot tube thst did the trick. It was some blockage it seems
@lamontgarrison3296
@lamontgarrison3296 3 года назад
@@grayfurnaceman combo gas valve is née and thermocouple it would not stay lit but the compressed air in line for pilot fixed it
@grayfurnaceman
@grayfurnaceman 3 года назад
@@lamontgarrison3296 Glad you got it going. GFM
@mutantbaby1672
@mutantbaby1672 5 лет назад
Can I use a household CO alarm to check leaks?
@grayfurnaceman
@grayfurnaceman 5 лет назад
I would not. Soap bubbles is a viable leak testing medium. GFM
@MOUSEBOWEN
@MOUSEBOWEN 4 года назад
You didn’t show how to remove the left gas pipe
@olgblueknightsbasketball6288
@olgblueknightsbasketball6288 7 лет назад
This guys is looney tunes with his doohickeys!
@S13KON
@S13KON 8 лет назад
Hello was just wondering what measurement type to set the manometer? psi Hg etc? Thanks GFM
@S13KON
@S13KON 8 лет назад
inH20? for WC measurement?
@grayfurnaceman
@grayfurnaceman 8 лет назад
+s13konrad Inches WC is the US measurement. GFM
@HarlanHarvey76
@HarlanHarvey76 6 лет назад
I wanted to see how you got the valve loose because mine won't rotate. The burner manifolds are in the way and there isn't room to rotate it. But you just cut that part out.....
@grayfurnaceman
@grayfurnaceman 6 лет назад
They were able to screw it on at the factory, you can get it off. Try removing the manifold/gas valve assembly. GFM
@HarlanHarvey76
@HarlanHarvey76 6 лет назад
grayfurnaceman I appreciate the response. I figured it out. Was just hoping to maybe get a hint from the video. On my big old shop furnace you can remove the manifold by removing 2 screws and sliding it out. then you can remove the valve and the gas line from the manifold and then rotate the valve off. Unfortunately, those who installed this furnace years ago put it too close to the wall so I had no room to slide It out(It is suspended from the ceiling in the corner) I removed the front rail that the manifold rests on and dropped it out instead. Uggghh. anyways, thanks. Took a lot longer than it should have. Thanks again, GFM HARLAN
@gerardomireles122
@gerardomireles122 8 лет назад
one question Gray where you connect the manometer one to the cap val where you connect the second one to check don't see and the video
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Gerardo Micelles You only need to connect it to the positive side of the manometer. The other one is left open to the atmosphere. GFM
@andrewha7939
@andrewha7939 8 лет назад
Hi Grayfurnaceman! I have one question: Single stage furnace valve is being replaced. Old valve had two wires, one shielded, that were plugged into terminals both marked MV. New valve has no markings. How do I know which terminals to plug the two wires on the new valve? Does it matter?
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Andrew Ha It should make no difference. GFM
@andrewha7939
@andrewha7939 8 лет назад
Thanks so much GFM. Your advice has helped me so much and I'm sure thousands of other people. Thank you for freely passing on your knowledge.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Andrew Ha Welcome GFM
@robertmetzler1stfed
@robertmetzler1stfed 2 года назад
So wait. I also have two wires running to my valve. Of there are 3 connections available. Are you saying that I only need to connect one of the wires to my new valve ?
@robertmetzler1stfed
@robertmetzler1stfed 2 года назад
And of course thanks for you video. Brilliant.
@HotNerd1980
@HotNerd1980 6 лет назад
Can combination gas valves be rebuilt?
@grayfurnaceman
@grayfurnaceman 6 лет назад
No. Also no parts available. GFM
@pmorris4133
@pmorris4133 2 года назад
i have a few questions get ahold of me when you can please
@khybersafi9137
@khybersafi9137 8 лет назад
I have an old American Standard Gas Furnace Model # GUF 800 E2. Serial # starts with H so from what I read online, it was made in 1993. I can't find any info on Google in regards to the Model # GUF 800 E2. I don't think it has a controller board or anything. It looks pretty basic. The issue with the furnace is that the Pilot light will not stay lit. As soon as you let go of the pilot light switch, it turns off. I replaced the Thermocouple with a Honeywell model from Lowes. Still the same problem. I called a local HVAC guy and he said to remove the pilot assembly and blow compressed air through it. That didn't solve the problem either. So I called him again and he said to probably change out the Gas Valve. My question is are these gas valves that have pilot lights & thermocouples universal or do I have to get a specific one? Is there a particular brand/model gas valve you recommend that will work with my old American Standard furnace? Thanks for all your help. I really appreciate the videos.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Khyber Safi I believe your unit is quite generic. Honeywell, Robertshaw, and White Rodgers all make generic valves. Probably any of these will work. Hope this helps. GFM
@khybersafi9137
@khybersafi9137 8 лет назад
+grayfurnaceman Is one more durable/reliable than the other when it comes to Honeywell, Robertshaw and White Rodgers? Which one do you prefer to use or recommend? What's a good place to buy them online? Do I have to stick with the pilot light or can I upgrade to a better form of ignition since I'll be changing out the gas valve anyways? Thanks.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Khyber Safi You must keep the pilot. I don't have a preference on the brands. They are all good. GFM
@khybersafi9137
@khybersafi9137 8 лет назад
+grayfurnaceman I think I will change change out the Pilot light too while I'm at it since the old one looks rusty and corroded. Won't hurt to change it out while I'm replacing the gas valve. What are some good brands for Pilot Lights? Thanks.
@grayfurnaceman
@grayfurnaceman 8 лет назад
+Khyber Safi Mostly the same manufacturers. GFM
@fucheduck
@fucheduck 10 лет назад
I am watching this because I don'rt even know how to light the damned thing. My "hot Dawg" Modine garage heater doesn't have a reset button so I am assuming that means I'll have to get an igniter to light it. I am not interested in doing any disasembly but I was wondering if you can use an in home carbon monoxide detector to check for leaks? I wanted to start this thing for our November freezing spell. I use my garage for many projects.
@grayfurnaceman
@grayfurnaceman 10 лет назад
fucheduck It should detect if mounted near the supply air. GFM
@fucheduck
@fucheduck 10 лет назад
grayfurnaceman thanks!
@johncoen869
@johncoen869 7 лет назад
thought gas valve had to be fitted so as not to fall to off position
@grayfurnaceman
@grayfurnaceman 7 лет назад
I think the valve used, as most, can be fitted in any position except vertical down. GFM
@Blovable2u
@Blovable2u 8 лет назад
I have a combination gas valve and my pilot stays lit, but i can't get the blower to kick on. what do you think the problem is. I have bought a replacement valve just in case. As a matter of fact the valve that i have is the same one that you're replacing in the video. c3602-200 is the part number for this particular gas valve.
@grayfurnaceman
@grayfurnaceman 8 лет назад
Does the main burner come on? GFM
@vg3095
@vg3095 8 лет назад
Bobby Love your blower motor needs to be replaced
@comforthomeexpert8923
@comforthomeexpert8923 8 лет назад
did you check the fan relay switch . just a thought
@johncoen869
@johncoen869 7 лет назад
meant on position
@thebackwoodsmechanic5029
@thebackwoodsmechanic5029 4 года назад
Do you have an email, I got some questions about a Vertical Wall Furnace, Suburban brand that's about 60 years old
@grayfurnaceman
@grayfurnaceman 4 года назад
Try Grayfurnaceman@gmail.com GFM
@Blovable2u
@Blovable2u 8 лет назад
not when the blower suppose to kick on
@loudpipesavelives69
@loudpipesavelives69 10 лет назад
Is soft refrigeration copper tubing acceptable as pilot tubing?
@grayfurnaceman
@grayfurnaceman 10 лет назад
You would have to check with the local gas supplier. Some natural gas has a high sulphur content that may corrode the copper. There could also be local codes against its use. Hope this helps/. GFM
@loudpipesavelives69
@loudpipesavelives69 10 лет назад
grayfurnaceman thanks for the info
@grayfurnaceman
@grayfurnaceman 7 лет назад
It depends on the makeup of gas in your area. In some areas, it will corrode copper. I do not use it. GFM
Далее
Furnace condensate drain cleaning
5:02
Просмотров 355 тыс.
очень грустно 😭
00:12
Просмотров 71 тыс.
Поплатился за подлые удары!
01:00
Replacing Your Gas Furnace Is Easier Than You'd Think.
58:23
The combination gas valve explained
8:20
Просмотров 379 тыс.
Service Call | How To Diagnose A Bad Gas Valve
10:41
Просмотров 116 тыс.
Forced-air Furnaces: The What, Why, and How
22:05
Просмотров 1,3 млн
Steam Boiler Maintenance: Step by Step Guide
30:29
Просмотров 64 тыс.