Подписаться 6 тыс.
Просмотров 217 тыс.
50% 1

"Learn more about home power backup solutions: www.duromaxpower.com/pages/ho...
Shop all our of home power backup generators:
www.duromaxpower.com/collecti...
POWER OUTAGES HAPPEN - the best thing we can do is be prepared for them. Our comfort and safety rely upon having a steady and dependable source of electricity. When the power goes out, you need the peace of mind that comes with having a reliable generator standing by... and there’s no better choice for home power backup than DuroMax.
Learn all you need to know about setting up home power backup in your home in our full-length tutorial.
▬ Contents of this video ▬▬▬▬▬▬▬▬▬▬
00:00 Intro
01:13 Natural Gas Connection
14:10 Air Conditioner Start Assist Installation
21:11 Electrical Panel Modifications
26:07 Connecting & Starting Your Generator
28:39 About DuroMax
▬ Items mentioned in this video ▬▬▬▬▬▬▬▬▬▬
DuroMax XP13000HXT 13,000 Watt Tri Fuel Generator
www.duromaxpower.com/products...
DuroMax XP5025GC 25-Foot 50 Amp Home Power Backup Cord
www.duromaxpower.com/collecti...
Appropriate Gen Interlock Kit - Specific to your Electrical Panel (Email picture of panel to Gen Interlock and they will provide appropriate part #)
www.amazon.com/stores/page/76...
Appropriate 50 Amp 2-Pole Breaker (Will be specific to your Electrical Panel)
Micro-Air Easystart Air Conditioner Soft Starts
www.amazon.com/stores/page/56...
Reliance Controls PBN50 50-Amp Inlet Box
www.amazon.com/Reliance-Contr...
Century Fuel Products SE-19A 3/4" Quick Disconnect
centuryfuelproducts.com/se19a...
MATCO NORCA Brass Inline Ball Valves
www.grainger.com/category/plu...
Southwire 6/2 Stranded Romex SIMpull CU NM-B W/G Wire
www.homedepot.com/p/Southwire...
#backupgenerator #powergenerator #portablegenerator #portablepower

Хобби

Опубликовано:

 

16 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 292   
@blh3741
@blh3741 Год назад
Great tutorial for all the required steps/trades needed to install. Actually, it's the best one I have seen to this date. Kudos!
@DuroMaxPower
@DuroMaxPower Год назад
Great to hear!
@davesarmanian175
@davesarmanian175 7 месяцев назад
Bought this great generator a little while ago. For the record I really like it! Works great and powers the entire house during a power outage. Obviously do the math and figure out what you want to use during a power outage. However, the only issue I want to report is you might need a bigger gas meter to use a natural gas connection to fuel your generator. Also recommend adding up all of the BTU's you plan to use during the Powe outage and then make sure your gas meeting can handle the additional 225K BTU's for the generator. So, if you buy the generator and it will not start on natural gas, call your gas company and get a bigger gas meter. Once I upgraded the meter the generator started up on the first crank. Best of luck!
@DuroMaxPower
@DuroMaxPower 7 месяцев назад
That is great advice! Depending on the location/municipality a larger gas meter may be needed.
@dudleypotter7491
@dudleypotter7491 Год назад
Great video,I'm going to purchase a stand-by gen for our home and this explained the installation perfectly. I'm not that handy , so I'll be contacting professionals to do the install.
@DuroMaxPower
@DuroMaxPower Год назад
Hi @dudleypotter7491 Make sure you send us a picture of your DuroMax setup!
@grb3748
@grb3748 6 месяцев назад
Excellent video. Very professional yet easy to understand. Thank you.
@DuroMaxPower
@DuroMaxPower 6 месяцев назад
Glad you enjoyed it!
@yourmanstan
@yourmanstan 7 месяцев назад
very impressed with this video. whether hiring or diy, this helps home owners know exactly what is needed
@DuroMaxPower
@DuroMaxPower 6 месяцев назад
Thank You!
@donaldpreston8256
@donaldpreston8256 Год назад
A very good and a very informative video thank you very much for taking the time to produce it
@DuroMaxPower
@DuroMaxPower Год назад
Glad you enjoyed it!
@tabithafranklin8750
@tabithafranklin8750 Год назад
EXCELLENT video!!! Thanks guys!
@DuroMaxPower
@DuroMaxPower Год назад
Glad you enjoyed it!
@Mr-Chris
@Mr-Chris 2 года назад
Wow, great video especially detailed on how to do the gas hook up. I did this install 3 years ago and wished this video existed. I know you're supposed to say call a professional, but it's totally a DIY job if you have the right tools and knowledge. This video did a great job explaining it. I have a xp12000eh modified for natural gas, a interlock 50amp inlet, quick disconnect on my gas meter, and a hard start kit on my hvac installed all by myself. I prefer this model generator as it's made for Tri-fuel out of the box vs modifying a Duel fuel to work as a Tri-fuel by installing a regulator.
@harleybodden1938
@harleybodden1938 2 года назад
What tonnage hvac system do you have?
@chuckv978
@chuckv978 2 года назад
I have the 13000eh and was looking into modifying it to Nat gas. Found a few websites...but...how did you do it? parts?
@Mr-Chris
@Mr-Chris 2 года назад
@@chuckv978 I did a video on this a few years back, keep in mind the 12000 is different than 13000, but the concept is the same. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-CNZIy6Mvv14.html
@DuroMaxPower
@DuroMaxPower Год назад
That is awesome @mr-chris. Do you happen to have videos or photos you could share and tag us in?
@Mr-Chris
@Mr-Chris Год назад
@@DuroMaxPower I sure do have Videos ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-aGno6yIY5LI.html & ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-CNZIy6Mvv14.html . I made sure to tag you in these videos
@am20093
@am20093 9 месяцев назад
This is a fantastic video - thank you!
@DuroMaxPower
@DuroMaxPower 9 месяцев назад
Glad you enjoyed it!
@roxanaquintana8620
@roxanaquintana8620 11 месяцев назад
Easy to assemble. Started on the very first pull!!
@DuroMaxPower
@DuroMaxPower 10 месяцев назад
That is always good to hear - thank you for choosing DuroMax Power Equipment!
@oilhammer04
@oilhammer04 Год назад
Excellent video. Thanks for sharing.
@DuroMaxPower
@DuroMaxPower Год назад
Thank you too!
@nate.leal.
@nate.leal. Месяц назад
Great video. Well done. Priceless.
@DuroMaxPower
@DuroMaxPower Месяц назад
Glad you enjoyed it
@hienaz723
@hienaz723 2 месяца назад
Thats great video. Its explain everything i need to know
@DuroMaxPower
@DuroMaxPower Месяц назад
Thank you! I'm glad the video explained everything you needed to know. If you have any more questions or need further assistance, feel free to ask! Call us at 1-844-DUROMAX.
@manuelluna370
@manuelluna370 21 час назад
Awesome information.
@DuroMaxPower
@DuroMaxPower 6 часов назад
Glad it was helpful! if you have any other questions feel free to give us a call us at 1-844-DUROMAX.
@gspot525
@gspot525 Год назад
Excellent video! We'll done!
@DuroMaxPower
@DuroMaxPower Год назад
Thank you! Cheers!
@joef1159
@joef1159 6 дней назад
Awesome video learned a lot 👍thanks for video 🙏🙏
@DuroMaxPower
@DuroMaxPower 5 дней назад
Glad to hear that
@shawnhicks369
@shawnhicks369 2 года назад
Great video
@DuroMaxPower
@DuroMaxPower Год назад
Thanks!
@Willy12927
@Willy12927 Год назад
Great video. Tri-Fuel generators are the only way to go.
@DuroMaxPower
@DuroMaxPower Год назад
Yes they are!
@tdyrkacz
@tdyrkacz 4 месяца назад
Why no tri-fuel inverter generator yet?
@cdurkinz
@cdurkinz 9 месяцев назад
This was excellent thanks.
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
Glad you enjoyed it!
@VS-wq4sy
@VS-wq4sy Год назад
Great video and very helpful installation of my inlet box
@DuroMaxPower
@DuroMaxPower Год назад
Glad you enjoyed it!
@hd16539
@hd16539 2 месяца назад
I didn’t catch where the white wire was connected to on the breaker box
@carlcapello9956
@carlcapello9956 Год назад
These professionals make the job of installing the gas line hook up and the electrical 50 amp breaker hook up look very easy but, in actuality, it's not as easy as it looks. You have to know how to do it correctly and that takes some knowledge know how to do it properly. If you think you can do the job, give it a try but, remember to have it inspected before you actually try running it. If you run into trouble, you can always call in the professional.
@DuroMaxPower
@DuroMaxPower Год назад
Hi Carl! They definitely make it look easy with their experience. We agree that an inspection is a great way to have peace of mind.
@smithn.wesson495
@smithn.wesson495 2 года назад
A very good general overview of the process to convert a home for using a tri-fuel generator. Of course, every state, local and city building codes will be different. Considering this work requires multiple utilities (gas, electrical, etc...) hire a professional contractor to complete this work. This video used 3 different men all from different contractors for a reason. This is not a do-it-yourself job for most people. Be safe, be smart and do it the right way.
@DuroMaxPower
@DuroMaxPower Год назад
Hi Smith! That is great advice - thanks for the input!
@alangarcia4411
@alangarcia4411 Год назад
I agree! I work for a gas utility and know just enough to be truly dangerous - lol. I would never attempt this as a DIY project. Think of the contractor cost as insurance to help you safely manage a power outage.
@fillie37d.71
@fillie37d.71 Год назад
Great video ! Very impressed with the detail of this step by step video. Can you please share a link to all items used in the process of making this video. Thanks
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! Please check the description for the items shown as well as guideline on other accessories.
@rwstarke
@rwstarke 2 года назад
The cost is higher but using a soft starter is better than a hard start and will extend the life of the outside unit. Also turn off some of the high amperage breakers and turn them on gradually after the generator power is running into the panel.
@DuroMaxPower
@DuroMaxPower Год назад
Hi @rwstarke That is always good advice!
@rrrr6863
@rrrr6863 Год назад
Lol was about to leave this comment. The in rush current is instantaneous and that meter he used is not able to detect the momentary current that the AC condenser actually pulls. I would guess it still has an instantaneous in rush of at least 40 amps, but it could be up to twice that. Micro Air East Start is the way to go and I have installed several, the other big bonus with soft start is that it will actually give your condenser a longer life as well 👍
@jamesdavison6394
@jamesdavison6394 Год назад
yeah i dont understand why a start-assist is not a common feature of All ac units - would prevent the brown-out & system stress that happens several times a day in the hot months
@jamesdavison6394
@jamesdavison6394 Год назад
@@rrrr6863 yup. that locked rotor amperage is probs closer top 70A
@rrrr6863
@rrrr6863 Год назад
@@jamesdavison6394 Probably because the manufacturers don't want people's AC to last longer than they already do. Hell, a good system should last you between 10 and 15 years. That's not a lot of turnover 🤷‍♂️
@richlikeg3722
@richlikeg3722 2 года назад
Paid a plumber to do all the connections and I can tell they ripped me off. I was doubting if I could do it but I did not see any videos at the time showing the process such as this. Seems very doable as I’m very handy. Good to know.
@markgutierrez9295
@markgutierrez9295 Год назад
Don’t feel bad. Doesn’t a licensed plumber have to do the job? Mind if I ask how much they charged you? I need to get this done too.
@rhpham2
@rhpham2 Год назад
@@markgutierrez9295 ran bout 50ft mainly straight run and was given a bill of $1300. Should had just told plumber to tap to gas line and add a valve then I can handle rest but all hindsight now
@markgutierrez9295
@markgutierrez9295 Год назад
@@rhpham2 got it. Thanks for the update.
@DuroMaxPower
@DuroMaxPower Год назад
Thanks! If there is every any other questions we are always happy to help
@rwstarke
@rwstarke Год назад
When I bought my new house, I had the builder add a natural gas line to the back porch which I use for my tri-fuel generator/BBQ. During the Texas Freeze I was running the generator, gas furnace and gas cooktop without a problem.
@mitchmintz111
@mitchmintz111 2 года назад
Great video! I wouldn’t put the generator on the curb for easy pickup. It might walk away in the middle of the night. REM to derate wattage output when running on nat gas or propane.
@DuroMaxPower
@DuroMaxPower Год назад
Great point!
@johnherrera7551
@johnherrera7551 6 дней назад
It was just for this video. It was going to the backyard.
@alangarcia4411
@alangarcia4411 Год назад
​ @DuroMax Power Equipment Great video - thank you! Question: at 11:34, the plumber describes a quick connect safety valve - it prevents gas flow even if the ball valve is open unless the hose is attached. I've searched online for that sort of connector but am coming up short. Can you post names of manufacturers and any model numbers? Thanks!
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! We recommend checking Century Fuel Products or MB Sturgis such as this one: amazon.com/M-B-Sturgis-Inc-Generator-Disconnect/dp/B01N6NLDB6?th=1 Please ensure appropriate sizing based off your application. Thanks!
@michaelh7770
@michaelh7770 Год назад
All the needed quick connect couplings are included with the generator. The female couplings have a poppet that is closed until the mating connection is made.
@mixalis11111
@mixalis11111 Год назад
The AC service tech did an excellent job explaining - very clear, detailed and organized on his thoughts. The other two guys were agonizing to try follow their sayings. Other than knowing why and how to install a hard start kit, the rest is not comprehended. The electrical section was the worst - I have no idea what he was doing because he did not explain anything!
@DuroMaxPower
@DuroMaxPower Год назад
Hi! Thanks for the feedback!
@alexromo9091
@alexromo9091 10 месяцев назад
I agree the electrical part of it was vague but there are other diy videos that explain that portion a whole lot better.
@darrylmarsh8252
@darrylmarsh8252 9 месяцев назад
Does anyone know what brand hard start he used??
@bobbygene8274
@bobbygene8274 5 месяцев назад
Get a soft start. Not a hard start. @@darrylmarsh8252
@benbohannon
@benbohannon Месяц назад
First time I’ve ever seen wirenuts used in a breaker box (by an electrician). Wooo
@user-yq2fd4zm4p
@user-yq2fd4zm4p Месяц назад
Regardless of the interlock, you should always turn off your main breaker before ever hooking up your generator, its just best practice!
@DuroMaxPower
@DuroMaxPower Месяц назад
Agreed, but that is what the interlock reinforces.
@southernoutdoors1862
@southernoutdoors1862 4 месяца назад
Great video I wish I had seen this before!!! Would have saved me money trying to use a portable for whole house backup power! I have gone through inverter route because of the clean power and sensitive electronics ie computers routers tv etc! So serious question I think the DuoMax XP16000IH inverter is my solution to whole house back up clean power with out having to parallel 2 9k is there a way to convert the XP16000IH from propane to LPG? If there is I will order asap thanks again for this informative video!!!!!
@southernoutdoors1862
@southernoutdoors1862 4 месяца назад
Sorry for the confusion is there a way to convert the XP16000IH from LPG to Natural gas
@DuroMaxPower
@DuroMaxPower Месяц назад
There will be a 16,000 Watt Tri Fuel Inverter coming soon.
@j.p.4541
@j.p.4541 4 дня назад
Brilliant video, concise and easy to understand. I do have a question, how much should I expect to pay for an install like this?
@DuroMaxPower
@DuroMaxPower 2 дня назад
It will vary by location however on the high side we would say budget for $2,000 but should definitely come in under that.
@j.p.4541
@j.p.4541 2 дня назад
@@DuroMaxPower Great thank you!
@Moondoggy1941
@Moondoggy1941 3 дня назад
7:41 The quick and easy way to measure that. 1) Measure from the half way into the threads to the wall and subtract 3" that will put the ell against the wall. 2) If using a bracket measure the bracket subtract 3" from the wall and subtract the thickness of the bracket. The second valve is redundant, remove it, it will cause a flow issue.
@DuroMaxPower
@DuroMaxPower 2 дня назад
Thanks for the feedback!
@joemooskie4444
@joemooskie4444 11 месяцев назад
Good video, but i installed a transfer switch next to my breaker panel . I can control which room i want powered. I am on propane , so i want to power certain rooms this will conserve on propane.
@DuroMaxPower
@DuroMaxPower 10 месяцев назад
Glad you chose the option that works best for you! There is definitely more than one way to achieve power independence. Thanks for choosing DuroMax Power Equipment!
@desl.1153
@desl.1153 6 дней назад
question i have a Druomax hybrid Elite DS 1300 EH DUAL FUEL. If i convert it to natural gas would it power up my Central air and refrigerator, TV and some lights????
@DuroMaxPower
@DuroMaxPower 2 дня назад
We do not recommend converting or altering the fuel system.
@carmenlena2010
@carmenlena2010 Год назад
Where did you find the Start Assist (Hard Start Kit)? The link on Amazon shows a different device with more than 2 cables.
@DuroMaxPower
@DuroMaxPower Год назад
Yes on Amazon, however the model will vary based on the AC unit you are using.
@marvin6148
@marvin6148 9 месяцев назад
Does your 3/4 inch inside diameter natural gas hose hook up to that generator via a 3/8 inch male flare On the generator? In the video I saw an elbow piece on the generator with a quick disconnect to that three-quarter inch natural gas hose. Where did you get that please?
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
Hi There! That elbow is included with the DuroMax Tri Fuel Generator.
@sergetorres611
@sergetorres611 6 дней назад
what size is the gas hose 3/4?.. I have a 30 amp set up and was going to change to 50 amp set up.. I have a soft start on my ac( awesome) but I have to go to a bigger generator and also a natural gas generator.. I'm writing this while on my 30 amp set up in Htown on day 3 without power from Hurricane Beryl!! Thanks for the video!! all the gas pipes are 3/4 for the hose and set up.. 1x3/4x3/4,?
@DuroMaxPower
@DuroMaxPower 2 дня назад
all 3/4" from the utility to the included DuroMax NG hose.
@dlpaez2714
@dlpaez2714 2 дня назад
where i can buy the hose and the quick conector ??? i live in houston tx thank you
@everss02
@everss02 11 месяцев назад
I'd prefer a soft start assist on the AC, but I guess a hard start works and is cheaper.
@DuroMaxPower
@DuroMaxPower 10 месяцев назад
There is always more than one way to get to the finish line whether its hard-start or soft-start, Transfer Switch vs Interlock.
@bobbygene8274
@bobbygene8274 5 месяцев назад
Soft start is the way to go.
@HyperSin
@HyperSin 8 месяцев назад
What about the thd damaging sensitive electronics, is there something i can use that wont cost an arm and a leg
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
With almost a million Generators sold, THD issues are nearly non-existent.
@devavilluri
@devavilluri 6 месяцев назад
Hello, thanks for great video. I see you used gas valve "matco norca 600 wog-150 swp" can you please post links to where I can purchase this but more importantly the gas pipe that connects to this valve and then in turn to the generator Natural Gas inlet. Appreciate if you can point me to right place to buy so I can avoid buying wrong items. Thanks
@DuroMaxPower
@DuroMaxPower 6 месяцев назад
Hi There Here is the link to the valve: www.grainger.com/category/plumbing/plumbing-valves/shut-off-valves/ball-valves/manual-ball-valves?attrs=Max.+Pressure%7C600+psi+WOG&filters=attrs. The above valve and pipe will need to be sized to your specific meter so please measure and then the pipe will be available at most local hardware/plumbing store.
@devavilluri
@devavilluri 6 месяцев назад
@@DuroMaxPower Thank you for quick reply - in the video there is specific call out to make sure to buy the hose that matches with valve, can you please list the hose that goes with that - as it was stated only those hose inlet nozzle can open the valve and hence a compatible hose should be brought with the item together
@justinhighdesertkeeper9251
@justinhighdesertkeeper9251 Год назад
Nice vid. Where is the Capasder kit found?
@DuroMaxPower
@DuroMaxPower Год назад
Hi Justin, They are available from micro-air.com as well as other online retailers.
@gregm7991
@gregm7991 Год назад
The correct web address is micro-air.com 😊
@DuroMaxPower
@DuroMaxPower Год назад
@@gregm7991 Correct - thanks for the correction Greg!
@adamcarpenter2207
@adamcarpenter2207 День назад
Will this generator ruin my electronics in my appliances?
@porschenut5610
@porschenut5610 8 часов назад
Why was the start assist used instead of a soft start device?
@JDEC1
@JDEC1 8 месяцев назад
Nice setup but since that generator is bonded to the frame don't you need a ground rod at the generator when connecting to the service panel though your inlet box?
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
Hard to speak in generality, however most applications for inlet to panel do not require bonding as the panel is bonded.
@mafosa9563
@mafosa9563 Год назад
"Impressive!"
@DuroMaxPower
@DuroMaxPower Год назад
Thank you!
@alanrodgers4156
@alanrodgers4156 2 месяца назад
I live in Houston with a detached garage and natural gas. My gas meter is located on the front of the house to the left side and my electric meter located on the rear right outside side of the garage. My breaker box is located on the adjacent side of the electric meter inside the garage. My question is do I have to run a solid gas line underground, towards the rear of my house, where I need to locate my generator or can I use a quick connect and connect only when needed?
@DuroMaxPower
@DuroMaxPower Месяц назад
A licensed Electrician should be able to run an inlet toward the side of the house where the fuel supply would be to save the hassle.
@moblack5883
@moblack5883 3 дня назад
@@DuroMaxPoweryep my electrician told me that today
@ProjektSol
@ProjektSol 6 дней назад
my electrical box does not have a main disconnect, will this be an issue? can i get one added in order to install the interlock kit?
@DuroMaxPower
@DuroMaxPower 2 дня назад
Yes, we recommend consulting with a local licensed Electrician.
@jrvane11
@jrvane11 Месяц назад
Do you need to cut the neutral wire on the generator in order to go from a bonded neutral to floated neutral condition?
@DuroMaxPower
@DuroMaxPower Месяц назад
No - we do not recommend altering the neutral on the Generator.
@awesomedee5421
@awesomedee5421 Год назад
If the generator turns off from too much load, will it automatically stop the gas flow or will that be an explosion ready to happen?
@DuroMaxPower
@DuroMaxPower Год назад
The regulator system in the generator is a "Zero Flow" regulator that will turn off the flow of gas into the engine if it is not running or shuts off unexepectedly. As always, for safety purposes it is suggested to turn off the natural gas supply at the valve installed by the plumber when the generator is not running.
@milesfromthemidwest
@milesfromthemidwest 5 месяцев назад
I bought the generator in this video, does it require a pressure regulator on the natural gas supply line?
@DuroMaxPower
@DuroMaxPower 5 месяцев назад
This Generator includes the pressure regulator.
@rickyc6673
@rickyc6673 Месяц назад
Is it necessary to replace the regulator at the meter by gas company? I heard when u use generator and use natural gas it needs a bigger regulator.
@DuroMaxPower
@DuroMaxPower Месяц назад
It will dependent on your service line.
@jbhobbyist9372
@jbhobbyist9372 2 месяца назад
Does your gas disconnect need to be in the horizontal position or can it be in the vertical position?
@DuroMaxPower
@DuroMaxPower Месяц назад
Either direction will work.
@jeffnash8537
@jeffnash8537 Месяц назад
Is a 250cfm meter and 125 ft of gas line from the meter at the road to the house enough volume for this generator? Mine is hard to start up but once running it’s ok. Only gas appliance is the kitchen stove.
@DuroMaxPower
@DuroMaxPower Месяц назад
For the XP13000HXT Generator the required fuel pressure at all load ranges are 6.0 - 9.0 inches of water column for Natural Gas. The BTU requirements are 225,000 BTU at full load.
@stormyoung713
@stormyoung713 2 дня назад
Wish they would have shown that in the video.
@nateitscake88
@nateitscake88 3 дня назад
I have gas but not sure if it puts out enough pressure for the 15000HTX... Anyone know what pressure in inches of water is normal for a gas meter?
@DuroMaxPower
@DuroMaxPower 2 дня назад
It will vary by location and utility however for DuroMax Generators you would want about 6-9 inches of water column.
@PhoeNix-gr2vz
@PhoeNix-gr2vz Год назад
When relocating breakers, it is obvious the wires are cut to the place it wire was set to. (What does 9ne do if the breaker wires are to short at the re location of the breaker?)
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! Since every jurisdiction is slightly different you would need to consult with a local electrician to confirm what would be code compliant.
@PhoeNix-gr2vz
@PhoeNix-gr2vz Год назад
@@DuroMaxPower Thank you for you reply. It does make since and since I am not an electrician I will contact a certified one in my region before playing with such dangerous thing. Thanks again
@TheBucktowncrazy
@TheBucktowncrazy 9 месяцев назад
Question I just bought and received my new tri-fuel 13000 generator. Regarding the soft start, I have a 3.5 ton American Standard ac unit. Is the soft start a universal product, or do i need to purchase a soft start that is made by American Standard? Of course, I'm going to consult with an ac tech to install it. Just asking so i can purchase it. Thanks
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
It will be made by an aftermarket company - usually Microair. It does need to be compatible with your AC unit, but not the same brand as the soft start manufacturer-wise.
@TheBucktowncrazy
@TheBucktowncrazy 8 месяцев назад
@DuroMaxPower I have another question. I just purchased and received my 13000 TRI-Fuel generator from yall. I see that the 15000 tri-fuel is being advertised. My 13000 is still in the box with the band wrapped around the box. If I want to send the new one back and pay the difference for the 15000 tri-fuel is that possible??? Thanks
@ronaldnaeyaert3653
@ronaldnaeyaert3653 8 месяцев назад
What size gas connection was used, 1/2 or 3/4?
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
DuroMax Tri Fuel Generators use a 3/4" Natural Gas Hose
@rickymejia48
@rickymejia48 Месяц назад
Hello where Can I buy the gas hose and the quick connect fittings in the Houston area ? Please advise
@DuroMaxPower
@DuroMaxPower Месяц назад
Hello... These are included with the purchase of a DuroMax Tri Fuel Generator. However if needed to purchase, please call us at 844-DUROMAX and we can get you hooked up!
@dlpaez2714
@dlpaez2714 2 дня назад
@@DuroMaxPowerhow long are this hose that came whit the generator???
@aholmes6612
@aholmes6612 Год назад
Which is better for an inverter generator, hard start or soft start?
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! That will be dependent on your Central A/C. Please check the manufacturer specs to confirm the best unit for your application.
@johnwilliamson4511
@johnwilliamson4511 Год назад
Soft start. With soft start inrush current to compressor is filtered through a potential relay before it starts compressor
@johnwilliamson4511
@johnwilliamson4511 Год назад
Thus controlled. With hard start assist additional torque is added inline straight to compressor capacitor to start compressor. It's forced or a "hard" assist and not "soft" or controlled. I'm and HVAC specialist 20 plus years trade in.
@mcofield490
@mcofield490 7 месяцев назад
Isn't an inverter generator necessary to protect electronic devices? Almost every product in a home today has a computer board. How is a Westinghouse generator safe without an inverter and does Westinghouse sell a tri fuel inverter generator? Thank look forward to your response.
@DuroMaxPower
@DuroMaxPower 5 месяцев назад
They are not necessary for electronic devices. While putting out a cleaner signal todays portable, open-frame Generators are safe for most electronics.
@smacleod69
@smacleod69 8 месяцев назад
This hurt my eyes. You are better off with a soft start kit for the air conditioner and is there an internal regulator for the natural gas in the generator ?Because I don't see one on the gas pipe itself.
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
DuroMax Tri Fuel Generators have a built-in regulator for Propane and NG. They do not require an external regulator for NG.
@carmenlena2010
@carmenlena2010 Год назад
I never saw where the plumber used the uchannel bracket. Does anyone know?
@DuroMaxPower
@DuroMaxPower Год назад
Thanks for the catch! It is shown at 26:14 as a brace and support for the gas line.
@bobbygene8274
@bobbygene8274 5 месяцев назад
He used a section of 7/8" unistrut with a 3/4" "strut strap" to secure the pipe with.
@user-ti4td1kc5q
@user-ti4td1kc5q 26 дней назад
What natural gas hose is that and where can we buy it
@DuroMaxPower
@DuroMaxPower 23 дня назад
It is available from us at DuroMax by calling 844-DUROMAX.
@ljs2001
@ljs2001 29 дней назад
Does this generator have bonded neutral? Is that something of a concern?
@DuroMaxPower
@DuroMaxPower 23 дня назад
DuroMax open frame Generators are considered Floating Neutral Generators. This means that they do not have a bond from the Generator frame to the neutral. The ground and neutral are connected together in the stator housing, but since the stator housing is on rubber motor mounts there is no continuity from the Generator to the frame.
@equinn2005
@equinn2005 11 месяцев назад
Did the generator come with the remote start kit, im looking to put one on mine but cant seem to find one
@DuroMaxPower
@DuroMaxPower 10 месяцев назад
The only DuroMax Generators that currently come with remote start are our Inverter line of Generators.
@equinn2005
@equinn2005 9 месяцев назад
So what is the inverter inline type? I have the XP13000HX and I would like to have a remote start for it.
@m9ovich785
@m9ovich785 Год назад
The only flaw I saw in this video is the Cable from outside is not properly secured to the back of the Panel Box. The Inlet box on the outside is big enough to allow a Hole in the wall to accommodate a Cable Clamp. Thanks. Mike M.
@DuroMaxPower
@DuroMaxPower Год назад
Hi Mike! You are not the only one - we also caught this on the final walk through. Rest assured it was cleaned up with a clamp.
@jamesdavison6394
@jamesdavison6394 Год назад
Lol i noticed right away - i even said out loud "hey man you gonna secure that thing" lololol
@pf5658
@pf5658 Год назад
I need this done at my house. How much is this particular unit?
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! The DuroMax XP13000HXT Tri Fuel Generator currently goes for about $2,499 and is available from many of your favorite retailers. Check out our site for more info.
@jerryvandyke9216
@jerryvandyke9216 6 месяцев назад
Are duromax generators available in Canada?
@DuroMaxPower
@DuroMaxPower 6 месяцев назад
Please check our Where to Buy: www.duromaxpower.com/pages/see-retailers
@gary-gilbert
@gary-gilbert 8 месяцев назад
Some videos say that style quick connect restricts the gas flow and will cause your generator not to run properly. I'm not sure if that is true or not.
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
Ours were all tested with this style and are designed to operate with it. No restriction issues whatsoever.
@bobbygene8274
@bobbygene8274 5 месяцев назад
You purchase the quick connect that will support the required BTU flow for your unit at full load.
@thomasaccuntius9946
@thomasaccuntius9946 Год назад
In my area you cant use galvinized pipe for any gas work, it's black iron or others.
@DuroMaxPower
@DuroMaxPower Год назад
Oh thats rough! Whereabouts are you located?
@VHP7044
@VHP7044 Год назад
Galvanized pipe should not be used with Nat Gas, Propane, Gasoline, Oil or Diesel Fuel. Only use carbon steel pipe.
@craigharrison715
@craigharrison715 6 дней назад
is a start assist and a soft start the same thing?
@DuroMaxPower
@DuroMaxPower 2 дня назад
Different manufacturers call it different things but yes. We recommend the Micro Air soft start for use with our Generators.
@Spaceballs30
@Spaceballs30 7 месяцев назад
Where is the part of the video that shows the required pressure you need at your natural gas connection, testing to verify the pressure is adequate, and then adjusting as needed? That's SUPER important in this application.
@DuroMaxPower
@DuroMaxPower 6 месяцев назад
Yes those are all valuable steps you mentioned.
@bobbygene8274
@bobbygene8274 5 месяцев назад
They didn't cover that step.....
@rupe53
@rupe53 Год назад
fairly straight forward production but fails to mention the size of the gas meter, which will be too small about 80% of the time. You'd be amazed at how much gas a gen set needs.
@DuroMaxPower
@DuroMaxPower Год назад
Thanks for watching! Due to the different applications and regions, customers are always advised to check with their local municipality for the most accurate information regarding their utility service capabilites.
@harry_hands
@harry_hands Год назад
Love the video but not the irritating looping background sound the editors call "music" but I call NOISE.
@DuroMaxPower
@DuroMaxPower Год назад
Thank you for watching!
@napoguevara6450
@napoguevara6450 Год назад
Air Conditioner Soft Starter ICM Controls ICM870-16A Soft Start Controls, Built-in Start the best no no hart star
@DuroMaxPower
@DuroMaxPower Год назад
Yes using soft start and hard start with air conditioners are the way to go!
@ghyo1
@ghyo1 Месяц назад
@@DuroMaxPower OK, but which should be used- soft start or hard start?
@pettypendergrass8596
@pettypendergrass8596 Год назад
I know everything, but i never heard of a start assist. that is the 'coolest' modification.
@DuroMaxPower
@DuroMaxPower Год назад
We think your comment was even cooler!
@Threedog1963
@Threedog1963 6 месяцев назад
Hard start kits help a home AC system even without a generator. We had one installed on a system after the first compressor failed within 5 years. After installing it, the next AC system lasted 15 years.
@fearlessfreep
@fearlessfreep Год назад
Is there a link to the hard-start AC kit?
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! Yes all of the items are listed in the description and here is the Micro-Air Easystart www.amazon.com/stores/page/56795066-0CB3-4DDA-8245-9DEFACD860F4?ingress=2&visitId=48e2611b-83be-4fb6-9594-7e18df2d49c2&ref_=ast_bln You will need to confirm compatibility with your AC unit.
@ghyo1
@ghyo1 Месяц назад
@@DuroMaxPower The hard start capacitor described, installed, and tested is not linked anywhere. Was that part of the video a mistake?
@phucung2678
@phucung2678 4 дня назад
Do anybody have the idea how much it cost for all the labor and Parth excluding a generator?
@moblack5883
@moblack5883 3 дня назад
Somebody quoted me $360 in Texas
@DuroMaxPower
@DuroMaxPower 2 дня назад
We would estimate around $2,000 but should come in cheaper than that. That would be on the high side. Please always consult licensed professionals.
@jossymacknil5441
@jossymacknil5441 5 дней назад
Whats the cost per day to run that generator let say the 13000?
@DuroMaxPower
@DuroMaxPower 2 дня назад
Will vary by fuel, with Beryl we have heard on Natural Gas in Houston it averaged about $20 a day.
@shaunmccarron8475
@shaunmccarron8475 3 месяца назад
Is that pre meter ?
@DuroMaxPower
@DuroMaxPower Месяц назад
Never pre-meter
@joelcalvillo-lm5gn
@joelcalvillo-lm5gn 7 месяцев назад
lol everyone read my mind about adding a soft start it’s the way to go, and you don’t need a 13,000 watt generator to turn on the condenser.
@DuroMaxPower
@DuroMaxPower 7 месяцев назад
Very true - Soft Start is the way to go!
@boby115
@boby115 Год назад
Not bad but let’s address a few things that may not have been mentioned or overlooked #1 now that a load is being added to the system let’s calculate the total BTUs, including the new generator and determine if the gas meter can handle the total load (this may include a call to the local gas utility to let them know your intentions on adding a load; especially if their computer system is set up for spike load readings). #2 those things on top of the meter are not called unions they are referred to as meter nuts. #3 let’s try to use an adjustable wrench on those service valves, pipe wrenches tend to marr the brass lugs on service valves. # 4 let’s try to incorporate a sediment trap at the generator and hose connection. And #5 it’s recommended that you take gas pressure readings (lock up & working) , this would involve all the gas appliances in the house plus your newly installed generator (running all at once for working pressure).Hope some of this information helps and stay safe out there.
@DuroMaxPower
@DuroMaxPower Год назад
Hi Bob! Thanks for the input and we encourage homeowners to consult with their gas utility company to ensure adequate natural gas delivery.
@boby115
@boby115 Год назад
@@DuroMaxPower , developing a customer/installing contractor checklist is one of the best ways to stay consistent and put an end to all the “ I thought” comments. Having worked for a full service gas utility for 35 years and now consult from time to time in my retirement, I can assure you keeping all the affected people on the same page is one of the best things you can do. I’m always amazed when I am gathering information for a claims report or sitting at a deposition table, people make statements like “ we never thought to contact the utility“ or “ we don’t have a set procedure, we only have the installation manual“ . Believe me there’s a reason why Airline pilots have a checklist ✅.
@robsapplianceplus6071
@robsapplianceplus6071 Год назад
#6 That is not an inverter generator and therefore not the correct type generator if you plan on using any electronics.
@boby115
@boby115 Год назад
@@robsapplianceplus6071 , you are correct 👍 and should be another thing added to the checklist. With all the different circuit boards on appliances today I believe these types of generators will be become obsolete one day.
@JohnCap523
@JohnCap523 Год назад
Actually, when adding gas load, it’s mandatory to inform the utility. That meter is not rated for that load assuming there’s heating equipment already attached. Additionally, the utility should install the takeoff point (tee), not a contractor, at the time they replace the meter (assuming the gas service is sufficient for the added load). Other comments: never apply pipe dope (sealant) to the first two threads; never wrench a close nipple like he did which damages the threads (and yea, that nipple leaked); never turn off the gas supply before closing all inside valves (and turning off any appliances with power to them such as a furnace or boiler or power vented water heater) or else any operating appliances will suck the gas out of the pipes requiring a lot more purging once the supply is restored. Lastly, the “coupler” to the right of the tee Tony installed, is not actually a coupler, but a pipe end protector, and while Tony didn’t install it, it should not be used as a coupler.
@cireflores9088
@cireflores9088 Месяц назад
Whats the diameter of the pieces of pipe did you used ?
@DuroMaxPower
@DuroMaxPower Месяц назад
Looks like it is 3/4"
@DuroMaxPower
@DuroMaxPower Месяц назад
It was 3/4" pipe.
@cireflores9088
@cireflores9088 Месяц назад
Thank you sir
@Nihilumbra
@Nihilumbra Год назад
Работа спецов 👍😎🇷🇺, ребята подскажите ,что такое pipe dope? Спасибо 😉
@DuroMaxPower
@DuroMaxPower Год назад
Привет рад ответить на это! Пайпинг для труб представляет собой герметик для резьбы, обычно известный как «майка для труб». Он используется на трубах, чтобы обеспечить уплотнение между резьбовыми соединениями. 🙂
@Nihilumbra
@Nihilumbra Год назад
@@DuroMaxPower спасибо, очень приятно получить от вас ответ. У нас в стране герметик данного вида не встречается. Пришлось почитать на английском 😂👍
@donhgr
@donhgr 8 дней назад
First thing to turn off by utility company is electricity and second is the gas when a disaster happens LOL
@herewegoagain4041
@herewegoagain4041 5 дней назад
U do know about the on/off valve at the place matural gas pipe come out the ground. Also there is a main breaker to turn off power feed from power line😊
@DuroMaxPower
@DuroMaxPower 2 дня назад
NG managed to stay on for all affected by Beryl. We do agree power is first.
@abecoulter8550
@abecoulter8550 Год назад
tri-fuel, i count 2, petrol and LPG
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! Gasoline, Propane and Natural Gas are the fuels this Generator accepts.
@rodgraff1782
@rodgraff1782 Год назад
Most utility company’s don’t allow contractors tamper with their gas meters
@DuroMaxPower
@DuroMaxPower Год назад
That is correct, they do not allow you to tamper with them. However, nearly all gas companies allow for additions to be added on to the home owners side.
@rodgraff1782
@rodgraff1782 Год назад
@@DuroMaxPower Adding a gas line to the customers side is not the problem. Dropping the gas meter is not allowed in most cases.
@jamesdavison6394
@jamesdavison6394 Год назад
"allow" Lololol so what
@rodgraff1782
@rodgraff1782 Год назад
@@jamesdavison6394 In my area, the utility company installs block off plates inside the unions They are the only ones who can initially turn the gas on. After they remove the sealing caps and turn the gas on, they Install lead seals on the meter fittings, so the can tell if anyone has messed with it. It’s a pretty hefty fine out here. Guess it’s not a problem where you are.
@jamesdavison6394
@jamesdavison6394 Год назад
@@rodgraff1782 yeah okay i hear that, i was being short. I'm a sparky, and i was dealing w/ PG&E out in bay area CA for 20 yrs. ... if i had to wait on them to change-over power most of the time i would have still not completed a portion of those jobs - i left there 3 yrs ago lol. I Fully understand Not messing w/ the Line side however. Thanks for your reply - Take Care out there
@thekat9593
@thekat9593 13 дней назад
Thread protector instead of coupling was installed original, classic. Should have changed it out while opportunity was presented.
@quisqueyapride5534
@quisqueyapride5534 3 дня назад
Ok good but how much is going to cost me to hire those guys? 1rs things 1rs how much?
@DuroMaxPower
@DuroMaxPower 2 дня назад
The installation cost will vary by location but we can guarantee it will be cheaper than a Home Standby installation.
@dlpaez2714
@dlpaez2714 2 дня назад
@@DuroMaxPowerI live in Houston, i need this jod in my house who can help me ?? i need the hose to , thank you
@christian14329
@christian14329 День назад
Please know Inverter generators are for your home use and power generators are for your power tools use!! Modern Appliances have chips that require inverters to handle fluctuation of loads, otherwise you could burn your appliances chips.
@gustavovega9921
@gustavovega9921 9 месяцев назад
Great video, however to be safe you must hire a professional plumber and electrician. Don't mess with gas is not worth getting hurt. Sometimes in life you got to pay for the safety of you and your family Cheeers
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
Great point!
@wmjohnson7063
@wmjohnson7063 2 дня назад
I thought galvanized pipe was bad to use.
@DuroMaxPower
@DuroMaxPower 2 дня назад
Code will call for different type by jurisdiction. Always consult a local, licensed plumber to confirm what can be used.
@MR-kl2ul
@MR-kl2ul 2 месяца назад
Have a solar powered backup to the gas powered backup 😉
@DuroMaxPower
@DuroMaxPower Месяц назад
All well prepared plans should account for all 3: solar power, fuel power and battery power.
@davidlemay4761
@davidlemay4761 28 дней назад
Natural gas is not volatile enough to start a cold engine.😮
@DuroMaxPower
@DuroMaxPower 23 дня назад
Tens of thousands of these units currently in service say otherwise.
@WV591
@WV591 7 дней назад
so we have to hire 3 technicians and buy the generator.
@DuroMaxPower
@DuroMaxPower 5 дней назад
Depending on the setup it could be 2 or 3 licensed technicians.
@bird289
@bird289 2 дня назад
...Or you can follow the video and do it yourself.
@Bob-cx4ze
@Bob-cx4ze 22 часа назад
I can't help wondering if Troy got paid for his appearance in generators.
@avflyguy
@avflyguy Год назад
One caution 🤔🤔 These hi-watt open frame generators are *not* *_inverter_* generators. The voltage and frequency (60hz) vary considerably. While they may be fine for most electric motors, lights, hotplates, electric stoves, hair dryers, elec space heaters and some coffee makers and the like, it is *NOT ADVISABLE* to use this power for sensitive electronics. TV's , computers, chargers, maybe even HVAC or anything that needs a constant clean wave of 60 hertz pure sine wave. The 60 cycles per second on this type generator are like a runaway train. Electronics simply can not handle wide variations either side of pure sine wave power. One possible fix is a good high quality UPS (Universal Power Supply) for electroics. It may try to stabilze dirty power to cleaner sine wave. APC and ISO makes some good backup power supplies.
@DuroMaxPower
@DuroMaxPower Год назад
Hi There! While you are correct that the unit shown is not an inverter Generator, they are safe for home use as we have spent countless resources testing and the customer base to speak for it. We also agree that a full portable home power backup setup should include surge protectors and/or VFI UPS's which are also commonly used with utility power. While no power into a home is perfect, with the right precautions nearly all accidents can be avoided.
@rwstarke
@rwstarke Год назад
I have a uninterruptible power supply (UPS) on my electronics (computer equipment, routers, TV, cable box). My UPS's seem to beep & click when connected to the generator. I have a stupid power strip plugged into the battery backup side with items plugged into the strip. All I have to do is move one plug to the surge protector side. And then turn off UPS. Surge protector should still work.
@avflyguy
@avflyguy Год назад
@@rwstarke The reason your UPS is clicking is because it is not seeing a clean 60 cycle (stabilized) power load coming in. Your problem is a surge (voltage- either to high or to low) so much so it's seeing dirty power, varrying power (voltage) but moreso it's not seeing 60 cycle pure sine wave. The power strip will not fix that. It's risky w/ just power strip - all that does is (don't count on it) is protect spike voltage surge, *not* 60 cycle sine wave. In a way, it's good that the UPS is trying to do it's job...just to much flucuation. Best fix is an inverter generator or a good size power battery bank (some mistakenly call solar generators) They don't _generate_ anything.
@rwstarke
@rwstarke Год назад
@@avflyguy Thanks. I know why the APC UPS clicks. I just use the Surge Protection (with EMI/RFI Filter) side of the UPS and not the Back-up Battery side. I do have a couple 300W Portable Power Stations and solar panel briefcase for just in case emergency power.
@avflyguy
@avflyguy Год назад
@@rwstarke Ah- You should be good. I've been using the APC Back-UPS Pro 1000 VA and have very pleased with it. Keeps desktop, modem, switch, wi-fi running a long time, with 26 inch monitor off. During the Texas freeze out a couple of years ago, were able to keep internet going and used laptops/phones and it went a good 15-20 hours (very low load on) I still would not trust any electronics on a non inverter generator. I got a Champion 2500i inverter dual fuel, so now it'll be safe on all electronics and will keep the furnace running (nat gas).
@ddynoah9208
@ddynoah9208 9 месяцев назад
If the gas company can't push the gas it's no good
@ahgaming2720
@ahgaming2720 8 месяцев назад
That generator can run on petrol too
@DuroMaxPower
@DuroMaxPower 8 месяцев назад
We agree, thats why 3 fuel choices are better than 1.
@jimmymack6938
@jimmymack6938 Месяц назад
your video is tight like that fade
@DuroMaxPower
@DuroMaxPower Месяц назад
Only the crispiest
@chetmyers7041
@chetmyers7041 15 дней назад
4:08 Be sure to buy a new nipple, because we crush this one during removal.
@DuroMaxPower
@DuroMaxPower 5 дней назад
Thanks!
Далее
90% Don't Know About This Fatal Generator Connection
11:17
HOME STAND-BY GENERATOR....EVERYTHING you need to KNOW!
18:58
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Cheap vs. Expensive Generator (Surprising Results)
25:49
Home Generator Interlock Kit Installation - EASY!
12:56
Дарю Самокат Скейтеру !
0:42
Просмотров 7 млн
50 YouTubers Fight For $1,000,000
41:27
Просмотров 138 млн
Дарю Самокат Скейтеру !
0:42
Просмотров 7 млн