Тёмный

How to solve scanner soundcanon ir 2016, 2018, 2020, 2022, 2025, 2030, 2318, 2320, 2420, 2422. 

Tech Humayun kabir
Подписаться 7 тыс.
Просмотров 1,7 тыс.
50% 1

How to solve scanner sound
canon ir 2016, 2018, 2020, 2022, 2025, 2030, 2318, 2320, 2420, 2422.
All Error codes
E000-0000 E001-0000 E001-0001 E002-0000 E003-0000 E003-0001 E007-0000 E010-0000 E019-0001 E019-0002 E052-0000 E100-0000 E196-0001 E196-0002 E197-0000 E500-0001 E520-0001 E520-0002 E531-0001 E531-0002 E540-0001 E540-0002 E540-0003 E540-0005 E542-0001 E542-0002 E542-0003 E542-0005 E575-0001 E575-0002 E584-0001 E584-0002 E716-0000 E719-0000 E719-0002 E733-0000 E736-0000 E739-0000 E744-0001 E744-0002 E744-0003 E744-0004 E805-0000 E808-0000.
Code: E000-0000
Startup error
The temperature detected by the main or sub thermistor does not rise to the specified value during startup control.
Check the fixing film connector. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0000
Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature (240 deg C) during temperature control.
Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0001
Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature (295 deg C) during temperature control.
Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E002-0000
Low temperature during temperature control.
The target temperature is not reached during temperature control.
Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0000
Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0001
Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.

Опубликовано:

 

19 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 4   
@rayanbinkabir6629
@rayanbinkabir6629 3 года назад
You are the best
@sumonghosal6350
@sumonghosal6350 8 месяцев назад
Thank you sir.
@georgebrocomputer8140
@georgebrocomputer8140 20 дней назад
Canono iR 2318L ful trning video chahiye
@VinitaKashyap-eu9lp
@VinitaKashyap-eu9lp 2 месяца назад
Sir machine ka scanner me na light a rhi aur nhi koi sound aur aage peeche b nhi ho rha h kya kre
Далее
Most common fault on a Dead Laptop
23:52
Просмотров 2,3 млн
Canon IR3245 Error Code E000020-0000 Solution...
9:36
iPhone 16 Ultimate Battery Test!
13:25
Просмотров 1,1 млн