Тёмный

How to Test for continuity and insulation on a Wash heater Element 

Richard Saupe
Подписаться 615
Просмотров 104 тыс.
50% 1

To Check Your element you will need a multi meter or have access to one!
just place probes on each terminal and look for a resistance of 20 ohm's to 70 ohms
if you get nothing at all this is called "OPEN CIRCUIT" and means your element needs replacing!
regards
Richard Saupe
Appliance repairman Ltd
Call 0800 44 88 999 or 01206 434 999
or visit www.appliancerepairman.co.uk
from Appliance Repairman Colchester Essex

Хобби

Опубликовано:

 

21 дек 2011

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 13   
@robertbotman4881
@robertbotman4881 6 лет назад
For general knowledge.... On my Bosch Nexxt 300 series WFMC2201UC, the specifications from the repair manual are as follows. Measure resistance all parts disconnected. Heater 13.7 - 15.2 ohms NTC 22.8 - 27.4 kilo ohms @68 degrees F. Water inlet valves 2.7 - 4.5 kilo ohms. Drain pump 140 - 200 ohms. Hope this helps some people with their repairs.
@richardsaupe
@richardsaupe 6 лет назад
Absolutely
@jeyleno6619
@jeyleno6619 7 лет назад
Thanks a lot, Richard. Very important information on insulation and resistance values!
@mohammedlahmadi122
@mohammedlahmadi122 10 лет назад
Thanks Richard. good explanation.
@Metallochem
@Metallochem 11 лет назад
Thanks very much Richard! Very helpful.
@TheRober806
@TheRober806 7 лет назад
Ol means open line not overloaded 👍
@rabbbie99
@rabbbie99 10 лет назад
Please, my Hotpoint Aquarius WM62P is starting to fill with water then the breaker in my fuse box is tripping. If I disconnect the wires to the heater element (leaving the thermistor wires connected). and try it, machine then works ok and goes through the cycle without tripping the power. I have a multimeter and checked the resistance of the element, I get 26 ohms which seems correct. I don't have a megometer (Insulation tester) to check that. All the wiring to and from the element looks good. Do you think it is the element that is needing replaced due to an insulation fault?
@noitamotuaeng5249
@noitamotuaeng5249 5 лет назад
OL means 'Open Loop'
@InefableTheo
@InefableTheo 5 лет назад
Help, please. I got no resistance when I checked my element. Do I need to buy a new one?
@richardsaupe
@richardsaupe 5 лет назад
Inefable Theo, if no resistance, it means open circuit, if you have your multi meter set up properly.... so yes needs element :)
@isaamali2888
@isaamali2888 3 года назад
Hi my machine samsung washer shows me code CH i changed heater but still shows me the code can you tell me what i do thank u
@margarethobbs2471
@margarethobbs2471 7 лет назад
You you did not press the test button on mega meter
@BarrySlisk
@BarrySlisk 7 лет назад
Maybe if you had zoomed in a little we could se what was going on.
Далее
How To Test Water Heater Element With Multimeter
11:38
Просмотров 220 тыс.
Replace heating element in a washing machine
4:04
Просмотров 116 тыс.
How to use a multimeter like a pro, the ultimate guide
12:55
Insulation Resistance Testing
24:46
Просмотров 377 тыс.
How To Tell If Your Water Heater Element is Bad
4:34
Просмотров 139 тыс.
How To Tell If Your Water Heater Element Is Bad
13:46
Просмотров 844 тыс.
Вечный ДВИГАТЕЛЬ!⚙️ #shorts
0:27
Эй Рамазан # DamirAgroDizel
0:17
Просмотров 3 млн