Тёмный
No video :(

How to use smart load for Deye hybrid inverter 

Kyle Zhang
Подписаться 883
Просмотров 29 тыс.
50% 1

It tells how to Smart Load function about Deye hybrid inverter

Опубликовано:

 

28 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@ramondasta5560
@ramondasta5560 2 года назад
Best low fans noise I have listened.
@forextrading2615
@forextrading2615 19 дней назад
Hi can you please help me the smart load never switches when the solar is zero.It stays on. What do you think is wrong. Battery settings is ON at 100 and off at 90
@lnostdal
@lnostdal 3 месяца назад
Seems there's a problem with this feature. When the battery SOC is 100%, the PV input Watt will be close to 0 - so smart load never triggers. Setting smart load trigger ON before 100% won't work in all circumstances, because battery SOC can approach 100% in parallell with smart load operation. A deadlock scenario basically. Any workaround for this?
@jimmyflorrs7146
@jimmyflorrs7146 Год назад
Hi Kyle, I configured the Deye inverter for off grid setup and connected all my loads directly to the inverter. No export to grid or to home load. But I still have power flowing in the grid. How can I zero out this power to the grid (I have sufficient power from Panel and Battery)?
@palmertshuma2389
@palmertshuma2389 Год назад
Check out the direction of your current transformer (CT)
@JRLsolarhub
@JRLsolarhub 3 года назад
hello Kyle, currently i am having a problem with my parallel, 2units -5kw hybrid. everytime the battery reached low voltage value/setting, it shuts-off for around 3 minutes before the grid enter. what is the correct settings pls.thank you
@kylezhang8343
@kylezhang8343 Год назад
please check FW version
@virgo9691
@virgo9691 Год назад
good day, i have 2pcs deye hybrid inverter connected in parallel can i also connect their smartload ports in parallel???
@kylezhang8343
@kylezhang8343 Год назад
Hi can
@kirodon
@kirodon Год назад
what the range you set foe the herts
@dibmatar3707
@dibmatar3707 2 года назад
Hello , the smart load its cutting off based the percentage of batteries only , although when the power of panels has decreased less than the power of smart load its stay on, any suggestions
@kylezhang8343
@kylezhang8343 Год назад
Hi please check whether the "grid on is always on"
@technik87
@technik87 3 года назад
Can you show function of microinverter connected to GEN input? Can it work without PV array connected to PV inputs? It will work when grid power is off? I want to retrofit hybrid inverter (SUN-3K-SG04LP1) to my microinverters PV installation (SUN1200G).
@kylezhang8343
@kylezhang8343 Год назад
Hi for the hybrid inverter it can work without PV connected even AC couple with mciroinverer
@user-ti7yw6qx4x
@user-ti7yw6qx4x 3 года назад
Hi what is the purpose of SMART load aside from addtional AC output??
@DanBurgaud
@DanBurgaud 2 года назад
Assume you have an overhead water tank. You want to pump water up into this tank when the level is very low, and stop pumping up when water level reaches full. This can happen randomly during the day or night. Now, let us assume you have Deye solar system in your home. You obviously would prefer to Pump Water into overhead tank during the day using Solar instead of at night and consume battery stored energy. Here is where SMART Load comes to play. You now connect the water pump to this Smart Load and set Deye Smart Load: 1. when Battery level reaches a nice level (in this example 92% to 86%) 2. and/or when the Sun is very strong (in this example >600W, higher if your smart load is big). 3. and/or when there is Grid Power (in this example he first did it without GRID, and later tried with GRID). Now, the water pump will be ON only when Water level is Low and Battery is high and Sun is very strong (with or without GRID). In cold countries in NA or Europe, they have water tanks for heating instead. They connect their Water Heater Tanks into Smart Load and let the Sun heat up the water tank. For agricultural applications, you can connect Irrigation Pumps in smart load to pump water during day only. Smart Load is for "non-critical" applications where devices can be turned off without any detrimental effect to you.
@borgessolar285
@borgessolar285 2 года назад
@@DanBurgaud tankou
@janco333
@janco333 Год назад
Also good for running the pool pump in summer
@mouradmourad7378
@mouradmourad7378 Год назад
Can I display the smart on my phone screen??
@kylezhang8343
@kylezhang8343 Год назад
didn't get it
Далее
Smart Load feature on Deye inverter used to max.
13:00
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 619 тыс.
Deye 8 kw hybrid Inverter. Updating the firmware
9:36
Deye inverter: Smart Load settings powering 2 geysers
4:24
SunSynk Work Modes Setup
15:40
Просмотров 65 тыс.
Deye napelemes inverter beüzemelés
24:03
Просмотров 9 тыс.
My last Deye video and questions that were asked.
8:26
DEYE Hybrid Inverter Setting and Installation
15:21
Просмотров 114 тыс.
Ajdarlar...😅 QVZ 2024
00:39