Тёмный

How To Vent & Plumb a Toilet (in 2024) 

Hammerpedia
Подписаться 118 тыс.
Просмотров 2,3 млн
50% 1

Grab Your FREE Cheat Sheet:
1. *** Free Toilet Venting Guide: hammerpedia.com/vent
2. *** 2 Free Bathroom Plumbing Plans: hammerpedia.co/diagram
3. *** Pick The Proper DWV Fitting: www.hammerpedia.co/fittings
⭐ Checkout Our Collection of Bathroom Plumbing Plans: ⭐
hammerpedia.com/bathroom-blue...

Опубликовано:

 

28 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 457   
@Hammerpedia
@Hammerpedia 2 года назад
Grab Your FREE Cheat Sheet: 1. *** Free Toilet Venting Guide: hammerpedia.com/vent 2. *** 2 Free Bathroom Plumbing Plans: hammerpedia.co/diagram 3. *** Pick The Proper DWV Fitting: www.hammerpedia.co/fittings ⭐ Checkout Our Collection of Bathroom Plumbing Plans: ⭐ hammerpedia.com/bathroom-blueprint
@EatShee-I-it
@EatShee-I-it Год назад
Re check your information from 5:15 about the IPC code regarding 3 toilets. Check the footnotes of table 710.1(1). There are footnotes on allot of these tables that are basically exceptions to the rule. Hope that helps your future study.
@EatShee-I-it
@EatShee-I-it Год назад
Actually, I stand corrected. That is my local IPC code. You are correct about the National IPC.
@ahci9585
@ahci9585 Год назад
So in Santa Maria California, is it IPC or UPC
@ferdinandtamayo369
@ferdinandtamayo369 Год назад
2Szx
@dpoarch
@dpoarch Год назад
@@ahci9585 california is UPC. Santa Maria may have additional codes
@bruceackman4526
@bruceackman4526 Год назад
I’ve been a plumbing wholesaler over 30 years. This is the best introduction to venting a fixture I’ve seen.
@TDlv12
@TDlv12 Год назад
Union?😅 Chicago still requires 3"x2" tee to vent a toilet. Most counties got different codes.. u should mention that. Venting by Wye u can add a sink to this vent and make wet vent..
@erikrobbins964
@erikrobbins964 Год назад
Yeah we always use 2 inch
@chrisb9902
@chrisb9902 Год назад
I hope you're not being serious.
@darincatanzarite6230
@darincatanzarite6230 6 месяцев назад
Man your videos are the shit! I love how you get straight to the point and answer all questions with no confusion! As a plumber it takes years of doing it to understand! Great job!
@canavarRo69
@canavarRo69 Месяц назад
Does it necessarily have ti be a closet bend or can be a long sweep 90 ?
@gregabrams5792
@gregabrams5792 8 месяцев назад
Best plumbing video on the internet. So good that I bought the venting course on the website. Highly recommend!!
@phylwilton1827
@phylwilton1827 Год назад
Really clear and detailed plumbing lesson. Exactly what I needed, to gain some confidence about what I must do myself.
@XC-Z-cv8qw
@XC-Z-cv8qw Месяц назад
When the world needed him the most, he returned
@makmak151515
@makmak151515 Год назад
Really like this guys voice and manner. Easy to listen to easy to understand. Am going to recommend to my friends and family
@timschosek4871
@timschosek4871 Год назад
He sounds like Owen Wilson
@gyo1439
@gyo1439 Год назад
Theses videos have easily taught more than the several DIY books i've read. The images are great
@depARTmentUhaul
@depARTmentUhaul Год назад
I just use my outhouse, no vents, codes or problems. Every six months I move over five feet and fill the old hole with the soil from the new hole. I'm super green and believe in giving back to nature.
@antoniowanton2563
@antoniowanton2563 Год назад
You died of dysentery.
@Ruben901
@Ruben901 Год назад
I bet spiders bite you alot
@nicoleharrison9645
@nicoleharrison9645 Год назад
Perhaps your outhouse is already on wheels, but when I read that you moved it, I immediately imagined you picking up one side and pulling in on its wheels, 😆.
@mattgrommesh4125
@mattgrommesh4125 Год назад
I mean, without a vent that outhouse I'd going to stink
@cenknight
@cenknight Год назад
😂👏👏👏
@delfinsanidad4887
@delfinsanidad4887 Год назад
Explanation is so understandable easy to follow. No hidden tricks. Bless you mr hammer
@Hammerpedia
@Hammerpedia Год назад
Lol thanks and blessing to you as well,
@miltonjasso5843
@miltonjasso5843 2 года назад
THANK YOU !!!! I'm literally working on my master Bathroom and this information got in the rigth time. Appreciate you time and effort to create this video !!. 👍🏼😉
@Hammerpedia
@Hammerpedia 2 года назад
Good to hear
@xiongen6560
@xiongen6560 2 года назад
Thank you so much for this content. I am happy to finally see you uploading more content.
@daldalo1675
@daldalo1675 7 месяцев назад
Really liked how easy it is to understand. Thank you
@barbarasmith9325
@barbarasmith9325 Год назад
I’m so thankful for you. I need a video on tying a guest house into the main septic tank line underground
@shar935
@shar935 2 года назад
3 years been waiting for your videos! Please don't cut us off again 🙏. Please Keep these great contents coming.
@Hammerpedia
@Hammerpedia 2 года назад
Thanks.
@tab529
@tab529 Год назад
Water Closet need not be vented This is one fixture unit that do not require to be vented
@NiceMuslimLady
@NiceMuslimLady Год назад
@@tab529 It CAN be done...but, there are special conditions required for it to actually be useful. If you have a high water table, for example, a ventless WC won't work well...unless you don't mind your bathroom smelling like a sewer. If your WC is on an upper floor, the long drop can cause problems because of the lack of venting. So...you might end up having to go back and installing a vent for the WC anyway.
@Skanzool
@Skanzool Год назад
Now this is a guy who actually knows what he's talking about. Nice video. Thank you for posting.
@johnbushur6080
@johnbushur6080 Год назад
Good stuff. Hope to see you again before another 3 years go by!
@davidmizak4642
@davidmizak4642 Год назад
You deliver excellent content to your audience. It's very interesting material. All of your effort put into creating this video is much appreciated. I'm truly grateful for your help!
@Hammerpedia
@Hammerpedia Год назад
Thanks David
@chrisb9902
@chrisb9902 Год назад
Don't fall for this horrible advice.
@Eastbaypisces
@Eastbaypisces 11 месяцев назад
​@@Hammerpedia when venting is it on to vent at an angle, so it could go up wall instead of right in middle of bathroom
@Beanz931
@Beanz931 11 дней назад
I had a friend in the military tell me my old toilet wasn’t vented that’s why it didn’t work. He got orders and never fixed the toilet for me. I live in the sticks and it’s not a big enough project to get a plumber out here. The people had an addition made. So I have one good toilet. But, it sure would be nice to have the other be there for more than cleaning. Thank you.
@LifeDiscovery88
@LifeDiscovery88 Год назад
cant wait to watch more of your contents ! like how to drain kitchen? or laundry room? how to connect multiple bathrooms? or multiple kitchen? please!!!
@samurilip
@samurilip 5 месяцев назад
Dude thank you for making this explanation so simple to comprehend
@isaacgichuki99
@isaacgichuki99 10 месяцев назад
need more videos from your animation they are great keep up the good work
@vienneliao2748
@vienneliao2748 3 месяца назад
Thank you so much such a wonderful video ❤❤
@user-dk7nl3xk2t
@user-dk7nl3xk2t 10 месяцев назад
Great video! Clear and inclusive! Thanks!
@marval550
@marval550 2 года назад
Awesome visuals! 👍 Great explanations! Thanks!
@liogonzalez8813
@liogonzalez8813 Год назад
Very educative video. Am not a plumber but it doesn't hurt to know. Thank you!
@beatorres6871
@beatorres6871 Год назад
👌❤️
@dorlynleger
@dorlynleger Год назад
Thank God you’re back, more videos please
@Hammerpedia
@Hammerpedia Год назад
Thank you sir.
@jerrypissonme
@jerrypissonme 11 дней назад
Great explanations sir!
@oderusurungus4438
@oderusurungus4438 Год назад
Sometimes a "wye" fitting won't work because the Joist space is too short and may possibly be more expensive as you need to use a 2" 45 fitting to make it ready to plumb the vent vertically. The most appropriate fitting in this instance is a 3x2 "tee" on it's back. If backwash venting/ wet venting then a wye is most definitely in order.
@baldknobfarmstead5167
@baldknobfarmstead5167 2 месяца назад
Please do more videos! Laundry plumbing would be great.
@harshmalkan8470
@harshmalkan8470 2 года назад
Educational. Enjoyed it. Thanx.
@cullensanner4355
@cullensanner4355 Год назад
I would love to see you make more videos! I love your videos very much
@CurlsOG420
@CurlsOG420 Месяц назад
GREAT information once Again! thank you
@relginparing6770
@relginparing6770 8 месяцев назад
Thank you for your video 😊
@HamiltonTileGA
@HamiltonTileGA Год назад
This is going to help a lot of ppl!!!
@oldtimefarmboy617
@oldtimefarmboy617 Год назад
One thing I would like to see addressed would be vented covers for the vent pipe that exits the building. As a custodian for 25 years I have seen times when the wind is blowing from the right direction hard enough, it will create a suction on the vent system strong enough to actually pull the water out of all of the traps. I have actually seen a toilet gurgling because enough water had been sucked out that it had become low enough that the air flow could not pull more water out but not so low that there was an open space for the air to flow without going through a small amount of water. The best traps in the world do not amount to a pile of packing peanuts if your sewer vent is sucking the water out and leaving a path for sewer gas to enter the building after the wind dies down.
@spiritualistgirl
@spiritualistgirl Год назад
i have a prob. its windy and the walls rumble, and the vent PVC stack..is vibrating..loud..but my parent n partner cant hear it??.. infra sound? it iiss that.. as i emptied all the tanks, toilet and turned off mains water.. its out of alignment..maybe leaking on the roof/???.. any ideas??
@oldtimefarmboy617
@oldtimefarmboy617 Год назад
@@spiritualistgirl The range of men's hearing is different from the range of women's. Like the eyesight of insects that feed on flower nectar range into ultraviolet and some predatory animal's eyesight range into the infrared. If the wind is blowing hard enough to cause your walls to rumble there is most likely nothing you can do to prevent the PVC stack from vibrating either. You would either need to build a wall that blocks the wind or make major modifications to the building. A vent pipe vent cover is not going to fix what your problem is.
@adamplummer2190
@adamplummer2190 Год назад
This is the orfice effect that carbs on small engines and old cars used. There are ways of siphoning using this same effect.
@mackellyman5642
@mackellyman5642 Год назад
How about a STUDOR VENT?
@davidmcmullen3780
@davidmcmullen3780 Год назад
Bullshit. Vents pull air in and release it the wind will never affect a vent the wind will only affect gas appliances. Studor vents only allow air in not out.
@anthonyhitchings1051
@anthonyhitchings1051 Год назад
Nice presentation, Sir
@luismatos2239
@luismatos2239 Год назад
Saludos Muy buena explicación Se entiende perfectamente Eres buen instructor de plomería Gracias, se te agradece Bendiciones 👍✊
@jameslowmanjr6141
@jameslowmanjr6141 2 года назад
Funny how this was on my timeline. I did Vo-Tech in carpentry for 3 years. We remodeling a home for training. I got the master bathroom. The instructor said this is your Budget and this is the code book. Code books are easy. 2 things. Minimum size max size. Min 2” max 4”. Done. But venting toilet problem. Instructor told me about this venting and said all other vents to it. I Learned this back in 1987. The instructor said what the video talked about. Why do you see odd things like a 3 inch vent pipe or in some cases a 4 inch vent pipe. If you have the room run one or two of them because somewhere in the codes you can only have so many vent pipes in to one. Like in the bathroom bathtub , 2 sinks , toilet all into a little 1.5 or 2 inch vent pipe that would not pass codes because if all of the appliances are running at the same time it ends up not being adequate venting. What was I gonna say he’s the instructor.
@rupe53
@rupe53 Год назад
... up north they don't get too strict on the vent size inside the house but going through the roof MUST be at least 3 inches because the more water flows the more likely it will frost up in the winter. Yeah, there's lots of older homes with 1 or 2 inch vents and those are probably single bath houses.... AND... it seldom goes to -20 outside.... BUT... that's why we have a new code. (because some DO freeze up)
@jameslowmanjr6141
@jameslowmanjr6141 Год назад
@@rupe53 I had to do some work on my septic lines. Went outside where the bathroom was started walking around kicking the dirt poking the dirt. It should be a four-inch pipe that comes off and comes right up to the top of the ground somewhere in this area. Nope not the case. This was like two years ago three years ago. My neighbors like what are you doing. Digging a hole running another check and vent pipe. He shaking his head. Well I got it all done. I see this on RU-vid about a month ago two months ago I can’t see when I posted. Maybe it was just a post from a state that said they change the codes or something. But I was always taught when I was in that field that’s how you run your vent pipes. As soon as I put mine in my wife comes out of the bathroom and goes what did you do to the toilet. She says it sounds like a vacuum cleaner when you flush it now. I said I eliminated back pressure lack of venting I allowed the water to go where it needs to go without any restriction so it creates a vacuum in the toilet bowl now. Because how fast the water is leaving the toilet. Now it’s a good thing because when we put the new environmental lesser water toilet in. It will flush perfectly.
@OSHomestead
@OSHomestead 2 года назад
Appreciate the information.
@robertkattner1997
@robertkattner1997 2 года назад
In some countries the toilet drains straight outside into an open cement box. Vent not necessary. Also the toilet doesn't have a trap so that fresh air blows on your butt.
@edwardmccoy274
@edwardmccoy274 11 месяцев назад
Side inlet combo, left or right hand. Side inlet elbow is handy to have in a tricky situation.
@johndoe6032
@johndoe6032 Год назад
Thanks for all of the great info! I'm looking to actually cut out a vent pipe to an old basement toilet that's been removed and the waste pipe has been capped. Do you see any issues with simply cutting the pipe out between the concrete floor and ceiling of the basement and capping off both ends? The roof vents have weather caps to prevent water from gathering at the bottom of the capped vent pipe. I had a plumber mention that he would do this, but I opted at the time to not pay him to do it and don't know if it was any more involved than he described. Thanks!
@beatorres6871
@beatorres6871 Год назад
Without this presentation I'd be lost in installing my main toilet and wet venting. thank you so kindly. Many blessings your way Gbu always ❤️🌹 greetings from El Paso Tx Upper Valley West Side.
@rogerbeaird3320
@rogerbeaird3320 4 месяца назад
Great content thanks for the knowledge 🇱🇷🇱🇷🇱🇷
@cowboy_broke
@cowboy_broke Год назад
This is great 👍 The new UPC horizontal dry venting is terrible.
@lvhr6176
@lvhr6176 Год назад
Excellent video, I am building my own house and we are at the Plumbing stage right now and having a difficult time finding a plumber to do the job, I do have a decent plumbing experience but never plumbed a whole house before, all I need is a plumbing plan to follow, any help or suggestions will be greatly appreciate it. Thanks you
@gonzalezfd
@gonzalezfd Год назад
Thanks for the video. Do you have a video for plumbing a kitchen?
@rayray8687
@rayray8687 2 года назад
I guess things have changed now in 2022 with these fancy newfangled porcelain devices but I still like the way toilets were ‘vented’ in 1922 - there was a louvred vent on the back wall of the outhouse and you just left the door open for a few minutes for cross-venting. I’m afraid to poop now in case I’m in violation of a code!
@jonathansfissella8249
@jonathansfissella8249 Год назад
Great illustration for the homeowners to understand just what you're talking about. "Okay so what you're telling me is that there is an air pipe in my sewer pipe to vent sewer gasoline where? " Or i know about the trap star and p cap, just dont overcharge me.
@deanguando1335
@deanguando1335 Год назад
Thanks for the information.
@valentinasmith8673
@valentinasmith8673 2 года назад
Thanks for you video it's great idea i see from Corpus Cristi,Tx 🙂👍
@Hammerpedia
@Hammerpedia Год назад
You are welcome!
@AsHellBored
@AsHellBored Год назад
so much great info
@user-wd5sj8dt4w
@user-wd5sj8dt4w Год назад
You should make more of these but do commercial plumbing !!
@bubbavox
@bubbavox 7 месяцев назад
Thanks for all the great resources. I'm assuming this is Sketchup -- what do you use to model drain pipe and fittings? In the past I used 'pipe along path' which simply converted lines to pipes of chosen diameter.
@youknowkbbaby
@youknowkbbaby Год назад
Plumbing is the most important human invention.
@ohhi1134
@ohhi1134 Год назад
I don't know why I watched this, but it was very informative.
@johngibbs7944
@johngibbs7944 Год назад
Just 2 minutes into this and I give 2 thumbs up!
@MartyHuie
@MartyHuie Год назад
Thank you for this video it really helps homeowner here about to start a house and was wanting to put in a wall hung toilet looking to understand it's venting and then also wear clean out potentially would need to be, can you advise?
@D.N.R.911
@D.N.R.911 Год назад
Thanks for sharing!
@CountDracula-qo2ch
@CountDracula-qo2ch Год назад
thank you very good best explanation
@orlandosanfeliz2956
@orlandosanfeliz2956 Год назад
Muy buena 👌 explicación ,las medidas son muy buenas cómo parte de la orientación.
@XRPBankster
@XRPBankster 11 месяцев назад
Haha you said more on. Haha. Great video it helped Mucho 🤙
@tylersmith293
@tylersmith293 Год назад
Thanks Owen Wilson.
@stuartkorte1642
@stuartkorte1642 Год назад
Wow, thanks. A little more complex than grandpa’s outhouse.
@abike3969
@abike3969 Год назад
Thank you got the guide
@scottwebber652
@scottwebber652 2 года назад
Did a similar install but just used a t vs. the 45 like the vid. Don’t use it as much so ittl lose the water in toilet on windy days. Question is does the 45 angle prevent the water loss ? I kept it at 3” size not reduced.
@SoopahKEN
@SoopahKEN Год назад
what program did you do this in and would this be a great way to learn how to build a small shed? or do you recommend another program?
@dwightrivera3281
@dwightrivera3281 Год назад
Wow amazing video
@alfredosalazar526
@alfredosalazar526 Год назад
As a service plumber, i appreciate at least a 3 inch vent line for a toilet and no reduction in size from original inlet. so if the toilet flange is 4 inches i expect the rest of the main line to be 4 inches other wise use a 3 inch toilet flange. and the same for the vent if im on the roof and the vent pipe is 3 inches i expect the rest of the vent to be 3 inches and to not reduce to 2 inches.
@catsmeow5566
@catsmeow5566 Год назад
Thank you for this. My home has every fixture (except a defunct shower that does not even have a trap) S-trapped, but my late plumber tried to fix it with circuit vents. They don't work very well though. My tub's trap will not hold water & I have it plugged up to keep sewer gases out. I'm planning to move a toilet to an exterior wall, install a new tub/shower, and a vanity (I'm swapping my laundry room with a tiny bathroom that is unusable). The DFU bit is useful.
@adamplummer2190
@adamplummer2190 Год назад
They have one way check valves for vents that may be worth adding for the sink. Also the main sewer line vent may be too small.
@catsmeow5566
@catsmeow5566 Год назад
@@adamplummer2190 I do have one through the roof-- looks to be about 2" pipe. I plan to tie in the washing machine, tub/shower, & toilet to that vent but the kitchen sink, lavatory, and other bathroom groups in the house will have their own separate vents.
@adamplummer2190
@adamplummer2190 Год назад
@@catsmeow5566 make sure if it goes sideways it's above any water points or it can fill with stuff. May need to be snaked.
@catsmeow5566
@catsmeow5566 Год назад
@@adamplummer2190 Yeah, all vents will be vertical for minimum 6" above flood level. For the ones not connected to main vent they will have their own individual vents that go through the wall, follow it up, and then elbow around the eaves and then elbow again to go above the roof. That is how the circuit vents are done. I am considering some AAVs for some of them since there is at least one atmospheric vent. The AAVs would be accessible for maintenance/replacement. Might need an AAV for kitchen sink specifically bc there is a window less than 6" above and if I tried to angle it around the window I'd hit electrical.
@kristy313106
@kristy313106 Год назад
You are the best!
@bradley3549
@bradley3549 Год назад
I was always under the impression that pumbing can never get So I was very surprised to see the 4" into 3"!
@garlandlew6408
@garlandlew6408 2 года назад
That shit was informative! Thanks for the info.
@shockingshorts8043
@shockingshorts8043 3 месяца назад
Usually that's when it's just a stack that just goes straight up out the roof and all of the plumbing is literally on that stack usually but that's pretty much only happening in older houses very older houses with maybe one maybe two bathrooms
@johnbeckwith1361
@johnbeckwith1361 Год назад
So glad I only do permitted remodeling. I get to plumb according to what works based upon my multi-decades of experience.. Obviously there is more than one way to make it work...the code books offer at least 2 different ways.
@ryanfrizz
@ryanfrizz Год назад
why can't the journeyman I work with teach me like this instead of calling me dumb for asking questions lol
@ricksanchez6411
@ricksanchez6411 7 месяцев назад
Ask a master, the always Cary the upc code book, I’ve been plumbing 40 years. Journeyman plumbers can only do a limited amount of work. A master plumber is required for any plumbing company
@jerrycasana1157
@jerrycasana1157 Год назад
Thanks for sharing
@robertjackson1407
@robertjackson1407 Год назад
Thank you 😊
@JohnMiller-ee9pn
@JohnMiller-ee9pn 2 года назад
You should have made mention of the dry vent rules for the DIY pro.
@DaveTan65
@DaveTan65 Год назад
They did this in Fukushima and it kinda worked.
@user-bi8ty1zp5q
@user-bi8ty1zp5q 3 месяца назад
Do we need to install vent for each fixture such as wc, lavatory,foot drain. If the fixture WC unit distance is less than 6ft from rise stack. In this case do need to provide vent in horizontal pipe or from vertical stack. Also share UPC, IPC latest version pdf file
@rabbytca
@rabbytca Год назад
All these diagrams I come across show the toilet fixture draining into a horizontal lateral and it travels over to the stack to get the waste down to ground level. Does one need to move the stack and the wall below if it is directly under the toilet fixture's outlet to create a horizontal flow before it goes vertical?
@soewin9784
@soewin9784 Год назад
Thanks.
@Cozcacuauhtli
@Cozcacuauhtli Год назад
THANKS
@TDlv12
@TDlv12 Год назад
Chicago still requires 3"x2" tee to vent a toilet. Most counties got different codes.. u should mention that. Venting by Wye u can add a sink to this vent and make wet vent..
@fredsalter1915
@fredsalter1915 Месяц назад
Great vid, sir! But I never could understand what is meant by "street-45" or "street-L". What does "street" mean? Thanks!!!
@hydemom811
@hydemom811 10 месяцев назад
excellent
@adanabundrz7017
@adanabundrz7017 2 года назад
Thank you sr
@Michael-jm5ix
@Michael-jm5ix Год назад
Can I use the 3 inch vent behind the toilet to install a wall mounted toilet and use the adjacent lavatory as a vent, would this be sufficient to code? I would then close up the closet flange.
@mattalbrecht7471
@mattalbrecht7471 2 года назад
Very nice video
@Hammerpedia
@Hammerpedia Год назад
Thanks
@dgb5820
@dgb5820 Год назад
Great video I will need to install a vent as the plumber did not
@lxxlss
@lxxlss 11 месяцев назад
thanks
@user-jg2ev4ke4h
@user-jg2ev4ke4h 11 месяцев назад
How long/high above the ground should be the venting tube? I have bad smell coming out of the toilet and someone suggested the venting tube was too low (like 30 inches above ground). Thanks
@joshcowart2446
@joshcowart2446 2 года назад
I was told in CE that UPC got rid of the toilet limit on 3” and just bases it on dfus. I haven’t look in the code book to verify yet because it’s usually irrelevant as I always run a 4” main anyway except in specific situations. As for the unlimited trap arm in IPC, is there an exception for flat roughing or for toilets because there is a limitation on trap arms. In IPC (the best code for trap arms) it’s based on 1/4” per foot fall. If the trap arm has this slope then at a certain point it will be an S trap. So you divide the ID of the pipe and multiply by 1’ and this is you max length. 3” would be 12’. The upc has seemingly arbitrary numbers. 1 1/2” is 3’ 6”, 2” is 5’, and 3” is I believe 10’. I do commercial so we mostly stack rough so there may be some exceptions I’m not aware of. I didn’t know if the length was allowed to be longer because a toilet is anti-siphoning
@daddy1571
@daddy1571 Год назад
Good question. I know that a WC waste arm was 6' maximum in our old Oregon Specialty Plumbing Code book,but they switched to UPC the last update! It's unbelievable. The things you're allowed to do,like running 4 WC on one 3" waste line. 8 WC on 4" too. I run 4" mains as well. It's just as easy as 3",but you're covered in case of fixture overload or additions.
@joshcowart2446
@joshcowart2446 Год назад
@@daddy1571 I work with upc everyday in Austin and as far as I know it has the same 3” 3 toilet limit. It is limiting with trap arms. We didn’t have any maximum for a wc trap arm. It was just the trap arm length for whatever size you chose. UPC, though seems to have completely arbitrary trap arm lengths. Like 5’ for 2”. I don’t know where that comes from. In IPC it’s 8’ based on the fact that when graded at 1/4” per ft you have 8’ before it’s an s trap. As for using 4”, when I started that’s all we used. I started in a small town. We one hardware store with a decent selection but still limited. The rest of our stock got delivered once a week. For this reason we only ran 4”. It automatically cut in half the amount of stock you have to keep. I only used 3” on repairs.
@daddy1571
@daddy1571 Год назад
@@joshcowart2446 Small towns are good places to grow up in. Probably what makes you a great plumber lol!(I'm from one too) I got a diagram from my city inspector that shows 8 WC on a 4" line. As long as you run vents between the last WC and your first WC you can run 8. Circuit vented branch is the specific name that it's called according to the diagram. I used it on an underslab rough this year. You just can't use combos looking up for your WC(I asked but the inspector explained why it couldn't). You have to turn them on a horizontal grade,then 90 up for your WC.
@joshcowart2446
@joshcowart2446 Год назад
@@daddy1571 yes I agree. Just in terms of plumbing I can think of how small town people are better. In the city, everything is an emergency. I’ve been called out for an emergency that turns out to be not at all what I would consider an emergency. Small town people, due to not having 24 hr plumbers available, know how to deal with things. They can get by until a plumber can get there. They either know more about how to do things themselves or they’re much more willing to make due. As for the circuit vent, yeah I’ve never actually done one but I remember being taught about them. I thought you were talking about sewer pipe sizing. I don’t know how the Oregon code is but from what I hear from lots of plumbers is UPC is stricter than IPC. I have to deal with both so I should know the differences because Austin is UPC but every city around Austin is IPC. The only thing I can think of off the top of my head is the UPC is more strict in terms of trap arm length. The rest I’d say they’re more similar than they are different.
@tonydoggett7627
@tonydoggett7627 Год назад
Australia only uses 100mm or 4 inch for all toilet piping. Vent pipe 50mm or 2 inch. All toilets are dual flush.
@Alexanderbuilds2001
@Alexanderbuilds2001 Год назад
Could I just use a continuous 4in pipe from toilet to sewage tank?
@mikealba3729
@mikealba3729 Год назад
Please make more videos!!
@WCFAsyncQueryable
@WCFAsyncQueryable 4 дня назад
Is the reduction from 4 to 3 inches required or is 4 inch drain pipe (without reduction) ok with UPC? BTW, if so, is it better?
@thudang3039
@thudang3039 Год назад
Thank you. =)
@plagueless9829
@plagueless9829 Год назад
You can use a tee instead of a wye and street 45°
Далее
Продавец года 😂
00:59
Просмотров 2,6 млн
When you know she has a wig 💇🏻‍♀️ #shorts
00:19
Что-то пошло не так 😂
00:15
Просмотров 417 тыс.
How To Vent & Plumb A Toilet (Step by Step)
2:01
Просмотров 1,8 млн
Plumbing Slope Rule and Why it is CRITICAL
10:08
Просмотров 78 тыс.
Продавец года 😂
00:59
Просмотров 2,6 млн