Тёмный

Plumbing Slope Rule and Why it is CRITICAL 

Todays Task
Подписаться 58 тыс.
Просмотров 83 тыс.
50% 1

Have an Idea for a video send us an email at mytodaystask@gmail.com
Thanks for Watching todays video. The Products used in today's video are lists below as affiliate links.
Want to send tools for Demo?
PO Box 6451 Logan UT 84341
(Tools will not be returned)

Хобби

Опубликовано:

 

1 сен 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 106   
@barrymilam9665
@barrymilam9665 9 месяцев назад
If you are using 3" pipe or bigger, you can slope it at 1/8 inch per foot by plumbing code. I'm a master plumber and I've been doing it for 51 years. Also the p-trap is a trap seal by holding 2'' of water so sewer gases are unable to Escape into a structure.
@sherazwilliam1358
@sherazwilliam1358 4 месяца назад
Sir, quick question, I am new to this and just wondering, if your doing an 2'' pipe is the pitch 1/4?
@conorlarkin7135
@conorlarkin7135 4 месяца назад
@@sherazwilliam1358yes
@DontLookBehindYou1
@DontLookBehindYou1 4 месяца назад
​@@sherazwilliam1358 just in case he doesn't get back with you, yes in the IPC code it's 1/4 inch for smaller than 3 inch pipe.
@CashflowMeDaddy
@CashflowMeDaddy Год назад
Please do a test for too much slope. We are all told all the time that too much slope causes clog because water would leave the solids behind. But I have had several plumbers swear up and down to me that it's a myth. That they have never seen a clog caused by too much slope.
@shafiqahmad6658
@shafiqahmad6658 Год назад
That's what I thought exactly.
@suspicionofdeceit
@suspicionofdeceit Год назад
It’s absolutely a myth.
@DontLookBehindYou1
@DontLookBehindYou1 4 месяца назад
I've been plumbing for quite some time and this always seemed mythish to me. I can see it somewhat, but it mostly seems to be applicable when the water can get pulled from a ptrap... I guess "too much slope" can be relative to the situation and amount of solids, etc
@shyft09
@shyft09 3 месяца назад
I've heard this in connection with the sewers in London and Paris which work with gravity and are over a 100 years old, but they were made with bricks, it might be something passed on from that time even though now we use smooth PVC pipes which maybe don't have that problem
@billfong5509
@billfong5509 Год назад
your show is helpful and informative. I run a hotel in such a cold place ( -50c) and have a lot of challenges with the plumbing systems. I found useful tips on how to prevent frozen pipes and improve the slope of the sewer line. Thank you for sharing and experience with me. I appreciate it!
@devinnorsworthy9154
@devinnorsworthy9154 8 месяцев назад
Jesus... how many feet beneath the ground does your pipes have to be??
@allwrong3114
@allwrong3114 Год назад
LOL! Great experiment and very entertaining! Getting ready to re-plumb my tiny old house. This practical demonstration was helpful!
@JTTTTx
@JTTTTx 11 месяцев назад
Plumber here-Actually there is a compound that has been created to duplicate the 💩. All toilets are tested with it. It Is somewhat like half cooked oatmeal. The other thing is called “ drain line carry “. Our plumbing system design takes this into consideration- for all layouts , it’s what we do. Venting, fixtures and fixture layout all are factors here. Pro tip- there is a limit to how far the solids will travel in any system even with the proper pitch. As I recall, it’s 45 feet with a 1.60 gallon flush, 2% pitch and 3” pipe.
@devinnorsworthy9154
@devinnorsworthy9154 8 месяцев назад
That's also why it is beneficial to have other lines assisting in carrying that waste. Like tubs, sinks, etc. I set up a system today. Have to finish it tomorrow.
@latonyaricks3294
@latonyaricks3294 Год назад
I know he was eating a candy bar….but somehow I cringed every time….lol. Awesome video.
@jodymorris9590
@jodymorris9590 Год назад
Absolutely loved Today’s Task today now to find my snickers snack..!
@sjstevens6375
@sjstevens6375 Год назад
Suggestion - put food coloring in the water next time so you can see it.
@devinnorsworthy9154
@devinnorsworthy9154 8 месяцев назад
People don't want the dye in/on the pipes.
@FrustratedBaboon
@FrustratedBaboon 3 месяца назад
@@devinnorsworthy9154 WTF are you talking about? He said for the experiment.
@devinnorsworthy9154
@devinnorsworthy9154 3 месяца назад
@@FrustratedBaboon 😄 🤣 😂
@bonniehoellein
@bonniehoellein Год назад
WOW Joel, Just wow
@Nick32176
@Nick32176 3 месяца назад
Eating a little chunk of snicker before throwing into the experiment saved him from a big trouble. very smart guy.
@lizlund7091
@lizlund7091 Год назад
I smell an experiment for a school project! Awesome!
@dannynamadula221
@dannynamadula221 Год назад
Appreciated. Good demonstration. Keep it up
@NYC_Plumber_Guy
@NYC_Plumber_Guy Год назад
Great video thank you for taking the time
@katrinaloving6625
@katrinaloving6625 Год назад
We had to replace ours line very informative and if anything your kids looked they where having fun learning
@shanehowle8894
@shanehowle8894 Год назад
Informative and very entertaining- thank you
@oh.you.know09
@oh.you.know09 Год назад
Ahahaha you're so dang funny! 🤣 I love how your videos are informative and entertaining at the same time!
@theresabeauchamp194
@theresabeauchamp194 Год назад
Joel ty for video but can you also explain regarding the different ply toilet papers with the plumbing system??
@kakashigaiden24
@kakashigaiden24 Месяц назад
hahaha you change it multiple times, i like the way you test things, consistency is the key.
@dianeh.3327
@dianeh.3327 Год назад
reminds me of Caddyshack! super informative as always!
@frankchythlook152
@frankchythlook152 4 дня назад
That's what it was! I was trying to think if it was The Jerk or another movie of that era. Thanks!
@AshwanikumarSainiARTER
@AshwanikumarSainiARTER 9 месяцев назад
The experiment is very useful to understand the dynamics, Thanks:-) As I understand 1/4inch per foot is the slope for a pipe with 2.5 inch or less diameter pipe or is it the same for all diameter pipes?
@butterflies222
@butterflies222 Год назад
Great video Joel!
@robertpaget809
@robertpaget809 6 дней назад
Don’t forget to put the cistern water in on the flush
@mattd8411
@mattd8411 3 месяца назад
Good job thanks for the time and dedication this took. Seems like sometimes its higher up so that would help also wonder if a vent would have helped.
@sethbeske268
@sethbeske268 Год назад
Great experiment it shows us what plumbing systems are like when the new houses are built great Job Joel I am from Wisconsin watching Bonnie’s channel for a long time and now this one so awesome!!! 👍❤️ keep up the great work Joel!
@SusyTH
@SusyTH Год назад
Interesting! And Thanks!
@ibrahimmohammed4368
@ibrahimmohammed4368 9 месяцев назад
great work
@Mountain-Man-3000
@Mountain-Man-3000 Год назад
I feel like this is an argument against low-flow toilets....
@TheRTM
@TheRTM 4 месяца назад
Question: Is there a meter or digital gauge that can be placed on the pipe to give you an accurate read on what the slope is?
@chadcutkomp6780
@chadcutkomp6780 3 месяца назад
I'll NEVER look at a snikers the same way. Hahahaha!!!!
@Southpaw07
@Southpaw07 Год назад
You got an A+ for the demo. 😂
@knowleskarateacademy3347
@knowleskarateacademy3347 Месяц назад
What slope would be considered too much?
@sandyc6569
@sandyc6569 Год назад
Loved the bloopers!! 😅😅😅
@erinbrown9897
@erinbrown9897 9 месяцев назад
The entire video was a blooper.
@millanightingale7062
@millanightingale7062 Год назад
This was a great video
@theCZarate
@theCZarate 10 месяцев назад
I am about to run lines for a new adu... and your video gave me all the knowledge i need it... ear a subcribe
@TodaysTask
@TodaysTask 10 месяцев назад
Welcome aboard!
@edthelasttribe9580
@edthelasttribe9580 Месяц назад
😂 ideally you check whole run with level as longs the bubble sticking out a bit on the other end of level that’s all it matters… toilet usually flushes the water at more faster phase than you pouring the bucket of water.. if you raise the soiled stack to high , you will have siphoning problems inside the toilet pan… you can do calculations referring to the plumbing water regulations, but most of time it’s experience how you use the level and how you install the soiled stack from the first place .
@vasili_pasioudis
@vasili_pasioudis 11 месяцев назад
An update to this video would be the perfect opportunity to MythBust that over sloping may risk water over running and leaving solids behind. Is this true or old wives tales from the times of clay pipes + requirement of minimizing water velocity into municipality sewer lines.
@FrustratedBaboon
@FrustratedBaboon 3 месяца назад
I keep a much higher slope based on the length of the pipe because you lose the momentum, a toilet pipe is usually less than 24" in length to the vertical 4" drain.
@guskalo1981
@guskalo1981 Год назад
I'm having a nightmare of a time with one of the bathrooms in the office building I look after with a bad slope and urea buildup.
@AnthonySomes
@AnthonySomes 8 месяцев назад
Good demo. Improvement suggestion. Colored water to see better in pipe
@kookia213
@kookia213 7 месяцев назад
Just to understand, when you say 1/4 inch for every foot => that is the height / depth of the leverage you need to position under the beginning of the tube? (like the black thing you put under it to simulate?). Thank you.
@mannylopez4133
@mannylopez4133 2 месяца назад
for every horizontal foot you elevate 1/4'". 4 feet elevate 1 inch. 12 inches elevate 12 *1/4 of an inch which will be 3 inches.
@sulimanorlanes8167
@sulimanorlanes8167 9 месяцев назад
Please make sa video of too much slope. thanks.
@kevinalfrey2633
@kevinalfrey2633 9 месяцев назад
I keep thinking off the baby Ruth pool scene on candy shack 😂
@shellyplant78
@shellyplant78 Год назад
i love joel and ive noticed kids always hang around because joel has chocolate but if joel wasn't using chocolate the kids wouldn't be hanging around
@mistervelux
@mistervelux Год назад
😂😂😂
@shannonser5368
@shannonser5368 Год назад
This is the first time you didn’t know s**t! 😆 Had to say it. 💜
@coatknight
@coatknight Год назад
media.tenor.com/-AYZ8Z08BbsAAAAM/spaceballs.gif
@Bamacher59
@Bamacher59 2 месяца назад
Great video but try venting the pipe 2-in vent pipe
@jking3892
@jking3892 Год назад
LOL ,, everybody wants to take a bite of the snickers
@nosferadu
@nosferadu 3 месяца назад
I will never eat Snickers again.
@dannydanny9875
@dannydanny9875 Год назад
Science Rules, Joel!
@murphmurph2124
@murphmurph2124 Год назад
Bananas soaked in dark coffee work great 👍
@oscarc6949
@oscarc6949 4 месяца назад
So I have a 100 foot run drain to main sewer line.. so .25 for every foot means i need to drop it 25 feet..! Lol thats no possible.. im i missing something..?!
@TodaysTask
@TodaysTask 4 месяца назад
I see what you are saying, but 100 x.25 25 inches not feet. So it would be roughly 25 inches deep.
@Monterrico14
@Monterrico14 2 месяца назад
Con Oscar!
@duckyone20
@duckyone20 Год назад
Listen. I know I'm a grown adult but for some reason the snickers and toilet paper made me chuckle. Great information as always though! I think you just wanted a snickers though lol
@caseycarlino10
@caseycarlino10 Год назад
I think a babe Ruth would’ve been better, think Caddy shack pool scene 😂
@TodaysTask
@TodaysTask Год назад
What was I thinking Baby Ruth would have been way better. "Cadyshack"
@duckyone20
@duckyone20 Год назад
@@TodaysTask you'll have to redo it now 😂
@ivysweets
@ivysweets Год назад
Lol it made me chuckle too and I’m also a grown adult! 😂😂 great video Joel!
@charliep5139
@charliep5139 Год назад
Once I saw the pile of Snickers bars, I knew this dude was legit... nice video. next time, color the water to make it easier to see or maybe put some glitter or something in it for that first plain water demonstration. Also, it seems like it would've been easier to find an extra toilet somewhere and rig it up on a table to do the demo instead of the ladder thing, heh.
@jasonholman1209
@jasonholman1209 Год назад
People say that it’s 1/4 or 1/8 inch per foot required but that is code MINIMUM.
@foxy5833
@foxy5833 Год назад
Enjoy those snickers!
@user-zx5rz9fu5b
@user-zx5rz9fu5b 7 месяцев назад
Maybe put the snickers bar in before the toilet paper... i usually don't wipe before i poop LOL
@sandyc6569
@sandyc6569 Год назад
Nooooo Did it have to be Sneakers? Why not Almond Joy!! 😂😂🤣🤣😂😂
@annaahmed8144
@annaahmed8144 Год назад
Haha, hi Sandy, I’m from England, I too love a Snickers (many years ago it used to be called a “Marathon” bar here). I wish he’d used a Mars bar - urgh, soooo sweet/sickly. Love all the new house build videos and looking forward to seeing the final grand reveal.
@sandyc6569
@sandyc6569 Год назад
@@annaahmed8144 Yeah or that one!! 🤣🤣 I to am excited for their future for sure!! 🥳🥳🥳
@MrRain-hk4zi
@MrRain-hk4zi Год назад
Nice demonstration. Poor use of the Snickers, you should have ate them first 🤔😉
@rachellehmann9962
@rachellehmann9962 Год назад
You should let the boys and Olivia participate in a more vlogs
@TodaysTask
@TodaysTask Год назад
I really like when they can help.
@roberte.6892
@roberte.6892 Год назад
We get it bro. We got it about 45 seconds in.
@shyft09
@shyft09 3 месяца назад
If only RU-vid had some kind of button you could click to switch to another video once you "got" it
@nikkihillhouse
@nikkihillhouse Год назад
nice video, but I would have eaten those before the video started,, 🙂
@alpinehs
@alpinehs 9 месяцев назад
😂 interesting video
@roylcraft
@roylcraft Год назад
Attach a 1" block to the end of a 4ft level, done!
@gregjones3453
@gregjones3453 9 месяцев назад
try 1/2'' block! Its called 1/8" per foot, we do it everyday on 4" and bigger pipe.
@hopelessnerd6677
@hopelessnerd6677 7 месяцев назад
Is this really a fair test, since there's no corn in a snickers bar to provide buoyancy? At least you took a bite out of it first. LOL!
@SlackerU
@SlackerU 4 месяца назад
That's not 2% slope, 2% is 1/4 per foot so I imagine you're just under 1% when the bubble is touching the line. I wish you had 100ft of pipe to video flow rates at different slopes for stormwater-drainage. I know the flow-charts are very accurate. For stormwater drainage a 4inch smooth-wall pipe actually needs 2.8% slope to achieve 3-feet-per-second velocity for self-cleaning capabilities. I have a stormwater playlist if you're bored with extra pipe to play with.
@budtackett8347
@budtackett8347 4 месяца назад
thats about normal ,small tank is a double flusher every time!
@prnfl
@prnfl 3 месяца назад
i really don't understand why you don't just have a bidet and less paper waste down the toilet
@TomatoTriVias
@TomatoTriVias 6 месяцев назад
Id rather use 5% slope instead of 2%.
@jonathanklopf7581
@jonathanklopf7581 11 месяцев назад
your not using enough water.
@Kittyk4ttori
@Kittyk4ttori Год назад
Need a vent lmao?
@misscracka
@misscracka 11 месяцев назад
Not working cause your table too long and it's tubing so it's level on the back side.
@august3231
@august3231 Год назад
ᑭᖇOᗰOᔕᗰ
@ResumeProInsight
@ResumeProInsight 3 месяца назад
you wasted the chocolate, never waste food like that...
@SPURVWastewaterProgram
@SPURVWastewaterProgram 2 месяца назад
Candy bars are heavier than poop.
@TodaysTask
@TodaysTask 2 месяца назад
I wish I would have known that.
Далее
Drainage Pipe Slope and Trench Depth Calculation
8:40
Просмотров 155 тыс.
Getting the Correct Pitch for Drain Lines
4:04
Просмотров 78 тыс.
How To Vent & Plumb a Toilet (in 2024)
6:59
Просмотров 2,3 млн
Running a sewer line part 2
27:45
Просмотров 133 тыс.
The #1 DWV Plumbing Mistake (and how to prevent it).
3:07
Prohibited Fittings & Connections
17:04
Просмотров 41 тыс.
Tips to Get Proper Pitch for Drain Pipe
4:11
Просмотров 49 тыс.
Level for Plumbing
6:16
Просмотров 25 тыс.
И НЕ ГОВОРИ, ЧТО НЕ БЫЛО😬🩸
0:37
Клаустрофобы, вы тут?😮
0:35
Просмотров 4 млн