How to Wire a Subpanel 

Tim Wilborne
Подписаться 87 тыс.
Просмотров 369 тыс.
50% 1

Опубликовано:

 

2 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 193   
@KevinCoop1
@KevinCoop1 Год назад
Tim, I need to apologize to you! Your video popped up and I watched it again. I saw my original comment. I am so sorry that I did not tell you how good your video and accurate your information was! Very well done! Respectfully, Kevin
@TimWilborne
@TimWilborne Год назад
Thanks Kevin, I'm glad I popped back into your feed!
@kevinwhite3102
@kevinwhite3102 3 года назад
I'm an Electrician in Arkansas and we put 2 ground rods on the main service to the house and one on sub panels.
@thomasmarable6818
@thomasmarable6818 2 года назад
Thats all I do in Virginia
@johnbrandon1416
@johnbrandon1416 Год назад
This video I finally found is like hanging out with your smart friend.
@TimWilborne
@TimWilborne Год назад
Not the smartest but hopefully I help with the basics. Thanks for watching 😁
@ziggyjohnston5302
@ziggyjohnston5302 5 месяцев назад
@@TimWilborne humble. Even better
@Dukemeistro
@Dukemeistro Год назад
You are an excellent teacher!
@TimWilborne
@TimWilborne Год назад
Thank you! 😃
@camandbrenny
@camandbrenny 3 года назад
Hey great job Tim thank you much for sharing... found this very helpful.. and from a guy whose just getting started on some youTube content myself truly enjoyed it.
@TimWilborne
@TimWilborne 3 года назад
Thanks!
@montimitchell5931
@montimitchell5931 Год назад
So you’re saying a sub panel needs ground rods driven into the ground and not ran back to the main panel?
@TimWilborne
@TimWilborne Год назад
No. In my locality, sub panels that are in separate buildings must have both a ground from the main panel and a ground rod. You need to check your local laws and codes.
@danielpascoe719
@danielpascoe719 2 года назад
This may be a stupid question.. but if one piece of equipment needs like 90 amps... does it draw from the panel as a whole? Or do you need to have like... say a bunch of unused breakers?
@jeffcox9930
@jeffcox9930 3 года назад
Good video. Better than most, Maybe in future a video about the theory and differences between wiring a standalone main panel and main panel subpamel. Example why you split the neutral bus and ground bus.
@TimWilborne
@TimWilborne 3 года назад
Great suggestions Jeff, thanks for watching!
@KevinCoop1
@KevinCoop1 3 года назад
I'm not a controls guy, I worked as design engineer for contractors and consultant from 1983-2018. Since you mentioned it in your video, what is your perceived purpose for the one or two ground rods in the electrical system? Not all sub-panels get them as stated, only if in a different building. Respectfully, Kevin
@TimWilborne
@TimWilborne 3 года назад
Hi Kevin. As far as one vs two ground rods, NEC 250.56 requires a second ground rod if the ground has a resistance of 25 ohms or more. I don't want to get into the argument of whether all sub panels should have grounds or not.
@KevinCoop1
@KevinCoop1 3 года назад
Tim Wilborne I totally agree with you on higher than 25 ohms requires second rod. In my code classes, it was suggested that it is cheaper to just drive two and forget it. Testing time would be higher cost than installing the second rod. What I meant by not all sub panels need ground rods, keeping this conversation in dwelling units, if you have a 200 amp main service panel in a dwelling, it is required to have all available grounding electrodes connected to it. Now put a 100 ampere sub panel in the middle of the dwelling next to the kitchen. No ground electrodes are required. Put another 60amp sub panel in a detached garage, a connection to grounding electrode is required. Note: this requirement of ground electrodes in separate buildings flip flopped back and forth several times between 1981 and 2005 NEC. Not looking for any arguments. Hope this clarifies my comment. Respectfully, Kevin
@ericwotton2046
@ericwotton2046 2 года назад
@@KevinCoop1 I beleive the main purpose of the ground rods in a simple dwelling is for lighting protection. Thats why a sub-panel in an annex building needs a ground rod. It gives a bath for nuisance current to bleed off the system. It also helps the whole electrical system have a reference to work with, one common ground. This becomes important in large buildings with multiple tranformers and sensitive equipment.
@KevinCoop1
@KevinCoop1 2 года назад
@@ericwotton2046 Sorry I did not get back to you earlier! You are correct!
@tenkill
@tenkill Год назад
@@ericwotton2046 if you are running 50 feet out to a garage underground and in plastic conduit. would a secondary rod be needed to ground the sub panel from lightning generated electricity coming through the main panel and out to the garage?
@bobridge5271
@bobridge5271 3 года назад
You said that live-to-neutral is 120V but that live-to-live is 220V.....shouldn't that be 240V ? Also, is the neutral bonded with earth in the main panel ? Many thanks in advance for your reply.
@TimWilborne
@TimWilborne 3 года назад
220, 230, 240,... They are all the same depending on the area you live in. Same with 110, 115, 120. Yes in the main panel the ground and neutral are bonded together. Nowhere else.
@davidhardin1402
@davidhardin1402 2 года назад
There is a long history on what we used in the past as far as volts go. We actually used 100 volts back in the day and the progressed to 110, 115, 120.
@JeremiahL
@JeremiahL 2 года назад
I noticed that your ground wire is significantly smaller than your supply conductors? Are ground wires sized differently than supply conductors?
@jspeed51
@jspeed51 3 года назад
I liked the Napoleon Dynamite dancer in the last scene there.
@drs4649
@drs4649 3 года назад
On a subpanel, aren’t neutrals and grounds supposed to be totally separate??
@TimWilborne
@TimWilborne 3 года назад
Yes there are David.
@throughoureyes5160
@throughoureyes5160 2 года назад
So heres what we have going on. We have a main pole that has 200 amp service to it. We have a shed that is about 350 to 400 feet away and we'd like to install a sub panel to feed an A.C. and a fridge. I think I need a 50 amp breaker at the main box then run #6 UF wire to the sub panel which will have two 15 amp breakers, one to feed an outlet for the A.C. and one to feed the outlet for the fridge. Does this sound like the right set up? Also would I need to worry about voltage drop or would this set up enable The A.C. and fridge to run without fault even with voltage drop. I have literally just started to learn about all this in the last week. Treat me like a toddler when answering please. haha
@tablatronix
@tablatronix 2 года назад
Do feeder terminals have to be torqued for copper?
@TimWilborne
@TimWilborne 2 года назад
ALL screw terminals are supposed to be torqued.
@thomassmearcheck2819
@thomassmearcheck2819 Год назад
im confused when you hooked up a white neutral to a breaker
@TimWilborne
@TimWilborne Год назад
The double pole is 220V
@thomassmearcheck2819
@thomassmearcheck2819 Год назад
Nice video tim ! but shouldn't the 3 wire be black and red to double breaker and white to neutral
@TimWilborne
@TimWilborne Год назад
@@thomassmearcheck2819 No one said this was 3 wire...that is typically for when your application requires a neutral.
@x7warrior735
@x7warrior735 2 года назад
Great Job ⭐⭐⭐⭐⭐ What type/size wire to run 115 ft to a sub panel to 200 Amp Main Breaker Box ?
@WhitneyWarsaw-wq3yt
@WhitneyWarsaw-wq3yt Год назад
Question...installed sub panel into our shop, when testing its running 110v at box and outlets..but nothing is working?
@TimWilborne
@TimWilborne Год назад
How an electrician to check it out. I won't cost much and you'll know everything is safe.
@mohavie2360
@mohavie2360 5 месяцев назад
could you hook up the ground of the subpanel to the ground of the main panel instead of running a seperate ground to the subpanel?
@TimWilborne
@TimWilborne 5 месяцев назад
No.
@tomsmith2395
@tomsmith2395 2 года назад
I am finishing my basement and was going to add a 100amp sub-panel right next to the current box. What size feeder wire should I use?
@mattk.5258
@mattk.5258 Год назад
11:30 Ground rods are super easy with a portable 30lb jack hammer, i've hammered in tons of them that way.
@TimWilborne
@TimWilborne Год назад
Yes, there's an attachment for a hammer drill that works well also. Thanks for watching!
@johnbrandon1416
@johnbrandon1416 Год назад
It seems hard to find a video or information, easy, about wiring/power cables, running from my house to my disconnected garage when my garage is not really disconnected. Its a 1975 house with an attached walkway to the garage with power cables running up in the attic all the way. Im missing something.
@rustycalvera977
@rustycalvera977 2 года назад
Is the panel box itself (equipment ground) grounded with just the two screws holding the grounding bar to the panel case? On the face of it, it doesn't seem sufficient.
@adamwagner7105
@adamwagner7105 Год назад
Not bad, but still need to watch another video to pull the power and run the conduit. Not a full subpanel install video. Basic "wire any panel" with the exception of the ground bar being different in a sub panel.
@kennethriviere3221
@kennethriviere3221 3 года назад
Simple but very informative. Just helped me on a project.
@TimWilborne
@TimWilborne 3 года назад
Great to hear!
@newday8172
@newday8172 Год назад
Why would you use a white( neutral) wire in combination with a black( hot) wire for a double pole breaker? Shouldn't it be 3 wire,red and black to double pole white to neutral and ground to ground?
@TimWilborne
@TimWilborne Год назад
Not all equipment requires a neutral. In many cases, only 2 legs of 120VAC and a ground are required.
@newday8172
@newday8172 Год назад
@Tim Wilborne appreciate your answer. Just a quick question. When wiring a sub panel, it should not be wired were the ground and neutral are bonded? What type of panel is that. Does it come not bonded?
@TimWilborne
@TimWilborne Год назад
@@newday8172 That could vary depending on where you are located but for the most part they are only bonded at the main panel, they are separate at sub panels.
@joro18d93
@joro18d93 Год назад
You didn’t explain wiring the right side as you said you would.
@TimWilborne
@TimWilborne Год назад
Seems like I did, what parts was unclear?
@eagle5720
@eagle5720 3 года назад
Why a inverter put out current through its neutral leg? I wire a 120v inverter to a two circuit 70amp breaker box and I'm get current through the neutral but I return the inverter cause its 3000watt pure sine wave inverter and can't start my vaccum and my other 2500 watt pure sine wave inverter could run my entire house.
@wildwoodtop
@wildwoodtop 3 года назад
4:38 also some child tamper-resistant / idiot protective safety built in 😊
@jaydonballman1135
@jaydonballman1135 Год назад
Can I add a neutral lug kit where that bonding screw went or is it good enough if it’s on one of the busses, I’m gonna add a grounding bar as well.
@bsmith8564
@bsmith8564 2 года назад
You exceeded code on a couple things, good for you. Ground rods only need 6 feet of separation and NMB needs strapping within 12 inches from the box not 6. I could not tell if the grounding electrode was continuous between ground rods as is required due to ground rod clamps are rated for one conductor only.
@thomasmarable6818
@thomasmarable6818 2 года назад
12" if cable clamp in box 8" if no clamps
@bsmith8564
@bsmith8564 2 года назад
@@thomasmarable6818 Correct, he has boxes with listed clamp. So 12" is maximum.
@bsmith8564
@bsmith8564 2 года назад
Just been going through my 08 code book and can't find the 8 inch requirement, Got a code reference? Thanks.
@thomasmarable6818
@thomasmarable6818 2 года назад
Its in article 334 not sure about 2008 but my state is on 2017 code cycle
@bsmith8564
@bsmith8564 2 года назад
@@thomasmarable6818I found it. 314.19(C) 334 is NM cable and only references 12 inch.
@Ho_ten
@Ho_ten 2 года назад
Great video for sure. Very informative. So I went to the link on determine wire size and distance. I am running a #6 (copper) from the house to my shed sub-panel. it's 165 feet. Probable will running a window unit at some point. Not running anything big, maybe a fridge, computer, small air compressor. So is number #6 to small at that distance or should I run #4? Setting up a 50 amp panel in the shed. Thanks!
@dnwrd34
@dnwrd34 9 месяцев назад
Did you get the link to work? I couldn't.
@RighttothePointDIY
@RighttothePointDIY 4 года назад
Thank you for a very well done video. I’m putting in a sub panel for a basement apartment. It will have a dryer and an electric stove so I’m going to have a sub panel. My question is related to the ground rod. I initially was going to put my panel on an inside wall but that would mean I would need to run the ground right up through the ceiling and then down to the outside. Can I assume that’s not ideal and I should put the panel on an outside wall? Also, can ground rods be drilled through the concrete slab and into the ground underneath the slab? I’m thinking no but I thought I would check.
@TimWilborne
@TimWilborne 4 года назад
Definitely want to check with local codes on the ground rod. At least here you could have it one an inside wall and run the ground to the nearest outside wall. I have no idea on the concrete slab, never ran into that situation. I would consult a local electrician, you'll be dollars ahead.
@RighttothePointDIY
@RighttothePointDIY 4 года назад
Tim Wilborne Thanks Tim. I will do that.
@dannycalk8051
@dannycalk8051 3 года назад
When you're past your outside main you do not run a ground from the panel to the outside, if you do you're defeating your purpose of having a ground path back to the main panel where the power supply enters the residence, if you ask an electrician be sure and ask someone who knows the code and has experience with installing sub-panels.
@Alphasig336
@Alphasig336 3 года назад
Having two grounds creates a potential for a ground loop within same building. You can use your main panel ground.
@AraceaeFanatics
@AraceaeFanatics Год назад
Okay, this was super helpful. We're running a sub panel into our shed to run an ice machine and a time clock, and this video helped with some of our questions, but everything inside the shed will be 120v, so do you have a video of how you connect this inside the main panel to feed the sub panel? Inside the shed will only be an ice machine, a time clock, and a couple outlets and 2 led ceiling lights. All 110, so we wouldn't need 240 coming into the shed. We'll have a separate breaker in the main panel for this shed, but how do we connect that breaker for 120v and 100 amps? The 100 amps is the bosses decision.
@traceyfrink6574
@traceyfrink6574 8 месяцев назад
That bit is called an AUGER BIT
@TimWilborne
@TimWilborne 8 месяцев назад
I can't recall, did I call it something different in the video?
@aammiranda
@aammiranda 6 месяцев назад
Great video. Why aren’t the neutral and ground bonded in a sub panel?
@TimWilborne
@TimWilborne 6 месяцев назад
You need to check your local electrical codes but here, they can only be bonded in one place, the main panel.
@usmarinekenny
@usmarinekenny Месяц назад
They aren’t bonded in a subpanel to eliminate a parallel path of current back to the panel on the ground and neutral. Since the white neutral is the return for current to flow back to the source, if you were to bond the ground to it, it would then share a path with the neutral and share the current flowing back and becomes a current carrying conductor which it was not meant to do. The ground is only suppose to carry current in a fault condition ie short circuit or ground fault. This is why they are separated. I hope that helps and was understandable.
@spencerwyche2552
@spencerwyche2552 3 года назад
I like to go close to the back of the stud so I won have toi use nail plates.
@taylorlightfoot
@taylorlightfoot 3 года назад
You then have to worry about nails from the outside siding into the "back" side of the stud. Always drill an appropriately sized hole in the middle of the stud. If you're using the correct size drywall screws, you don't need to worry about nail plates.
@homershamlimited2889
@homershamlimited2889 Год назад
Where can I get your T-shirt?
@TimWilborne
@TimWilborne Год назад
We never put that shirt out publicly but we get enough request that we should! Here are the shirts we have. timwilborne.creator-spring.com/
@rikityrik
@rikityrik Год назад
Don’t quit your day job there buddy…. Oh wait, nevermind. Jk lol. Enjoyed this, good information and well put together. Thanks for sharing! Btw that panel you flashed on the screen looked killer!!🤩
@TimWilborne
@TimWilborne Год назад
Haha, I know to stay in my lane. That panel that I showed was artwork and that takes many years of practice.
@chongxiong2491
@chongxiong2491 Год назад
Would there be a case were a residential complex would have 480 coming in
@TimWilborne
@TimWilborne Год назад
Maybe on large chillers used for the whole building, elevators, etc but not inside the dwelling.
@jamesleung1528
@jamesleung1528 Год назад
very good directions, good teacher for all electrical contractors,
@x7warrior735
@x7warrior735 2 года назад
Excelent Job ⭐⭐⭐⭐⭐
@TimWilborne
@TimWilborne 2 года назад
Many thanks
@GymChess
@GymChess 3 года назад
For anyone new at a workplace or wherever it's needed or required, the "cosmetic" part of it takes a long time to get a feel for. It can really be a pain in the neck to sit for hours bending and twisting cables and wires only for the looks.
@TimWilborne
@TimWilborne 3 года назад
Yes. I don't know if you ever stop trying to improve on that!
@GymChess
@GymChess 3 года назад
@@TimWilborne And don't ask me how I know... I remember being new at a place and how much time it took to mess around with the wiring and to make it look good, etc. The tasks per se weren't difficult even though I'd never set my foot there before let alone worked with those things in my life. Once you knew exactly what to do and how to do it right it was okay. The trickiest might've been reading the charts correctly, like connecting certain components on to the boards. Anyway, to cut a long story short, the job lasted for 2 months when I had to quit. I used too much time in someone's opinion. In MY opinion, kicking someone out after 2 months is ludicrous.
@LightWalker03
@LightWalker03 7 месяцев назад
Thank you much
@TimWilborne
@TimWilborne 7 месяцев назад
You are very welcome
@StoicThrower
@StoicThrower 2 года назад
I appreciate your mention of the ground rod installation. I believe when my place was done, I may have had one of those vendors that cut the rod short. I'm running into bleed over issues with one circuit on a 100-amp panel and have a few suspicions.
@ericwotton2046
@ericwotton2046 2 года назад
I'm curious what you mean by bleed over issues? Could you elaborate?
@StoicThrower
@StoicThrower 2 года назад
@@ericwotton2046 Voltage is being split between the neutral and the ground wire without tripping the breaker.
@ericwotton2046
@ericwotton2046 2 года назад
@@StoicThrower Interesting, is it just one circuit causing the issue? Your panels are all networked properly with grounds and neutrals separated back to the main service panel (where they combine.) You might have a ground fault within that circuit either an appliance or improper wiring in the brach wiring. A ground rod really wouldnt effect this much unless multiple transformer are involved.
@StoicThrower
@StoicThrower 2 года назад
@@ericwotton2046 yep. One circuit. Checked it all. Replaced every receptacle. Wired correctly. Nothing was plugged in. Never did find a definitive reason for it. Ran a new 20 amp circuit with no drama.
@seanvandermolen7287
@seanvandermolen7287 2 года назад
i don't think that grounding rod should have been installed in the first place. The grounding bond should only be at the mains panel. By adding another ground rod, you can potentially create another path back to source through earth that would cause the issue you're talking about. The bleed is current on ground where it should not be.
@wiley0714
@wiley0714 2 года назад
Ya lost me. If I had a double pole breaker. That means I have one breaker that has two outputs. I would put my black wire into one of them. And then I would put my red wire into the other pole. Let's say I had 12 three wire. I would have a bear ground wire, a red wire and a black wire, and the white wire would be the neutral wire. I don't understand why you would put a white wire which is generally a neutral wire into your breaker?
@TimWilborne
@TimWilborne 2 года назад
Not all 220VAC requires a neutral. For example this is a common dryer plug that you would use a 2 w/ ground...black, white, ground. amzn.to/3SJ7GpD
@classicv8dude268
@classicv8dude268 Год назад
I’m using white wire for 20 amp breakers
@ProjectDadLife
@ProjectDadLife 2 года назад
Great video! Subscribed.
@TimWilborne
@TimWilborne 2 года назад
Thanks!
@christopher_roger
@christopher_roger Год назад
No main on the sub panel?
@TimWilborne
@TimWilborne Год назад
Not required but can be there. Remember this varies by locality so check codes applicable to your area.
@christopher_roger
@christopher_roger Год назад
@@TimWilborne it does vary. A requirement for some, a convenience for all. You can back feed a breaker equal to or larger than than the feeder breaker in the main if the sub doesn’t have a main.
@lowkey1080
@lowkey1080 3 года назад
I appreciate this video. Learned something new watching this video. Keep up the good work!
@TimWilborne
@TimWilborne 3 года назад
Thanks, will do!
@oralreid7714
@oralreid7714 7 месяцев назад
You are really good.. thank you sir..
@TimWilborne
@TimWilborne 7 месяцев назад
Thank you :)
@aammiranda
@aammiranda 6 месяцев назад
Thank you very much; you are awesome
@TimWilborne
@TimWilborne 6 месяцев назад
Happy to help!
@340rps
@340rps 4 года назад
The part I needed to see you sped up the video!! ... connecting the main supply wires to the panel.
@TimWilborne
@TimWilborne 4 года назад
What do you need help with?
@policebo
@policebo 3 года назад
Great Great Great video man. seriously I watch a lot of videos on different topics. You nailed this one!
@TimWilborne
@TimWilborne 3 года назад
Awesome! Thank you!
@Mark-m9z4q
@Mark-m9z4q 2 года назад
Thank you for such a good video. God Bless.
@TimWilborne
@TimWilborne 2 года назад
You are welcome
@colbylammers382
@colbylammers382 3 года назад
I rarely post a comment but this was precisely what I needed. Also you had a few tips that were spot on
@TimWilborne
@TimWilborne 3 года назад
Great to hear Colby!
@theallaroundguy2399
@theallaroundguy2399 3 года назад
What is the main difference between a main panel and a sub panel? Is it just that in a sub panel the ground and the neutral wires have to be on their own bars?
@TimWilborne
@TimWilborne 3 года назад
Basically. The neutral and grounds must be isolated and a sub panel is powered out of a main panel.
@theallaroundguy2399
@theallaroundguy2399 3 года назад
@@TimWilborne I also have another question if you have time. If you were to open up a panel on a new home with three pin wiring and you were to open up a panel on an older home with only two pin wiring how would you tell the difference right off the bat just by looking? Not for sure if you understand this question or not.
@PedroPerez-gn6jl
@PedroPerez-gn6jl 3 года назад
Lee Sales kk
@David-zv2em
@David-zv2em 4 года назад
when you use a double pole, why do some people refer to it as 240 and some refer to it as 220 like you did. What is the difference? Thanks.
@TimWilborne
@TimWilborne 4 года назад
Nothing. 220, 230, 240, and occasionally the label 200 VAC single phase are all the same. Even across the US there are variations on which term is used
@mdhsabh
@mdhsabh 4 года назад
@@TimWilborne 110V used to be the standard, so power was called 110/220. Since the standard is 120, it's 120/240. 240=2*120.
@jw6829
@jw6829 3 года назад
I’m putting a breaker box in a cargo trailer and using a 50 amp rv plug would I wire the breaker box the same way
@TimWilborne
@TimWilborne 3 года назад
RV wiring has it's own section of NEC code, check it out.
@jw6829
@jw6829 3 года назад
Thank you I’ll check it out
@PaulJones-bo8gt
@PaulJones-bo8gt 2 года назад
Excellent video
@TimWilborne
@TimWilborne 2 года назад
Thank you very much!
@Rico702Vegas
@Rico702Vegas Год назад
So 120V + 120V = 220?? Man I need more math lessons lmfao. You are definitely not an electrician.
@TimWilborne
@TimWilborne Год назад
Here is your video #jerkalert 😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂 😂😂😂😂😂😂😂😂 ru-vid.comCjHqWe-JZpg
@elsolitario8020
@elsolitario8020 3 года назад
Thanks for the video it helps a lot for my next project. Actually what size of wire i can use from the main panel to the subpanel? Thanks again.
@user-pt8dz7uk7e
@user-pt8dz7uk7e 3 года назад
Dear Tim I have a detached garage 40 foot from the house. I understand that I need a ground bar seperate from the neutral bar. Can I run a seperate grounding rod to this garage subpanel grounding bar? What is a floating ground? Can I run the conductors from the house to the lugs on the sub panel or do I need a seperate disconnect at the subpanel? Thanks
@thomasmarable6818
@thomasmarable6818 2 года назад
Yes you run it to the groundbar plus a ground conductor from your main panel
@robertknull456
@robertknull456 3 года назад
I need to add more circuits. I have a 100 amp fuse box and I would like to add a sub panel with about 16 to 24 circuits. Can I add a sub panel rated for 125 amps to a 100 amp main panel?
@francoisdesmarquis8548
@francoisdesmarquis8548 2 года назад
Need an upgrade to 200 amp
@urhuck1eberry
@urhuck1eberry 4 года назад
You got a lot done in 12 mins. Lol
@TimWilborne
@TimWilborne 4 года назад
Yes I usually do a half a days work while drinking my coffee :)
@Dieselfreek26
@Dieselfreek26 3 года назад
This video was great. I'm in the process of wiring a sub panel into my new garage and the panel did not come with a ground buss. Thank you for the solid info
@TimWilborne
@TimWilborne 3 года назад
Glad it helped
@heroknaderi
@heroknaderi 4 года назад
I appreciate your time. I’m installing a few in my house.😁👍😎 I have a split bus panel. And I’m using my skills and still keeping the rule of six😁
@TimWilborne
@TimWilborne 4 года назад
Glad to help!
@ozzmann3217
@ozzmann3217 3 года назад
What do I do if I have a full main breaker box and want to add a sub panel ? Is there a Way to grab one of my other breakers for the sub panel? I’m not going to use this as my only source just want to see if my project is even possible I basically have a full breaker and the original basement outlet and so many others outlets and lights are on one single 15 amp breaker so I wanted to add a circuit for basement for my workshop and sub panel seems the only choice i have
@joshuacassino7297
@joshuacassino7297 3 года назад
Hello. I currently have a 40amp sub panel and need to accommodate an extra 60amps in it. In the 40amp sub panel there is a 15 amp and a 30amp. What size breaker do I need in the main?
@jakearmstrong4563
@jakearmstrong4563 Год назад
I don’t mean to be that guy I just would absolutely never use that bit it is just too comically large to even justify picking up instead of a paddle bit. Seriously a whole set of diablos is like $20
@TimWilborne
@TimWilborne Год назад
You mean spade bits? Nah, I can't agree with you on that one. An auger bit takes less effort. Let the rolls do the work. And I have shorter ones for tight spaces but this one is much easier on the body.
@jakearmstrong4563
@jakearmstrong4563 Год назад
@@TimWilborne alright fair enough i concede
@goose1451
@goose1451 4 года назад
You mentioned a link to calculate the wire size based on load and distance. Do you have that available? I’ll be running to a sub panel 100’ run from the main. I’m unclear on exactly what type of feeder breaker I need. But will need at least 75 amp feeder.
@TimWilborne
@TimWilborne 4 года назад
Hi Wes. See link below. www.theautomationstore.com/wiring-determining-wire-size-and-voltage-drop-for-amps-240-120-vac/
@goose1451
@goose1451 4 года назад
@@TimWilborne 2AWG it is! Thank you
@4RyanEck
@4RyanEck 2 года назад
@@TimWilborne thanks Tim, do you also have a chart that shows the size for neutral and ground for the sub panel?
@briannorton3205
@briannorton3205 2 года назад
Great video, Tim!
@TimWilborne
@TimWilborne 2 года назад
Thank you.
@Roadglide911
@Roadglide911 3 года назад
220v arc welder and a 220v air compressor. What size sub panel and gauge wire should I use? Approx 150’ run from disconnect to building.
@mikey4016
@mikey4016 3 года назад
Not all 240V arc welders are the same and not all 240V air compressors are the same. First you would need to know the maximum amperage draw from them, then you would need to go to a voltage drop calculator such as: www.southwire.com/calculator-vdrop I think the NEC allows a maximum voltage drop of 5%, but I would shoot for no more than a 2% voltage drop, even though Southwire recommends a 3% voltage drop.
@MrWaalkman
@MrWaalkman 4 года назад
I was going to tell you to stay in your lane, but you're already there. Looks like you've done this a time or two. :) I'm not saying that I'm an old electrician, but I still remember doing new installations using TW wire (and thank your lucky stars if you haven't had to pull that garbage into a conduit - however, it does do a great job of pointing out if you haven't reamed your conduit properly). I was taught to strip the sheathing off of the Romex cable prior to running it into the panel, and it does make for a little bit tidier of a job. But that's really just how my Journeyman beat it into me, rather than any personal preference (my personal preference being not to be beaten anymore than I had to be). Anymore, I would just go ahead and run the second ground rod and be done with it. Copper water lines into the house is a thing of the past. And to anyone who wants to do their own wiring, I would suggest visiting a construction site under the guise of being potential buyers and look around to see how the "AHJ" (Authority Having Jurisdiction) wants it done. But be fully prepared to have your job turned down even if you have done your wiring the exact same way as the pros. It's just a homeowner thing, and complaining to the AHJ is only going to make it worse. Oh, and: 1) Bring donuts and coffee. 2) Show up just before first break. 3) Keep a sharp eye out for the boss, and if he/she is not there, chat up one of the electricians to see if they would be interested in helping you out. Keep in mind that some shops treat "side work" as a firing offense, which is why you have to make sure that the boss is elsewhere. 4) Don't be a jerk. Pay in cash. And in slow times like these, the AHJ will turn down everyone's jobs pretty regularly to keep his inspector buddies from getting laid off. As an electrician, shop owner or otherwise, it is in your best interest to pay this bribe since what you don't want to see is your normal inspectors having to move on and then you have to break in a new one.
@TimWilborne
@TimWilborne 4 года назад
Early in my career I pulled some 500 MCM wires one time, I realized really quickly that I better stick with controls.
@MrWaalkman
@MrWaalkman 4 года назад
@@TimWilborne Oh yeah, that's a workout. Not to mention running the conduit for those cables, including busting a hole for two 4" conduits *horizontally* through a concrete footer. Ever run a jackhammer horizontally? No fun...
@TimWilborne
@TimWilborne 4 года назад
I never have found the programming port on a jack hammer to make it work.
@MrWaalkman
@MrWaalkman 4 года назад
@@TimWilborne LOL! The programming port was where my journeyman was going to put his boot if I whined about running the jackhammer. :) That really was the installation from heck. We had a heavy rain the day before it was to be inspected (so it was still open for inspection), and the ditch where we had our two 4" PVC runs got completely backfilled with sand. The conduits, being empty, naturally rose to the top of the ditch and were sticking out every fifty feet or so. So we had to hand dig the ditch again, this time being careful not to break our conduits. I was happy to see that run get finished. Pulling the wire wasn't too bad, we used a capstan puller, and each of us young bucks got to pull the wire off of one spool each. I've been involved in worse pulls... :) Another really bad ditch was one that fed a pad mount transformer and went down the center of an alley to the vault. It had eight "known" crossings. A combination of water, telephone, cable TV, power, as well as a sewage line below all of it. It also had one "unknown" crossing which the city neglected to locate for us, and we naturally found it, and removed it, for them. It was an abandoned water line that the city had simply capped off rather than removing. We ripped the unmarked line right out of its corporation (what the city water crew called the connection between the main and the smaller water line). Ever see how much water can come out of a 3/4" hole at 800 PSI? It's prodigious... The city tried to blame us, claiming that we were responsible for items that they had missed. Right. Our company wasn't having any of that nonsense, and the city got to fix and pay for the damage. It wouldn't have been as bad but the corporation was mounted at about twenty degrees from horizontal and the water pressure undercut a large portion of the parking lot to an attorney's office which collapsed into the ditch. Of course the ditch filled up in no time at all, and that little hole was now providing the center of Colorado Springs with a decent sized stream for the kids to play in. So there's always an upside. And this was also one of those runs that had to be encased in concrete, so we had that to deal with as well once the carnage got cleaned up. We also had to run a ditch for our power behind a strip mall that we were wiring. We had contracted a guy to cut the trench with his Ditch Witch. The only located line was a telephone line marked for us by Ma Bell. As the dutiful apprentice, I offered to hand dig that section out for him. He said "Don't bother, I can feel the cable with my stinger". Nonetheless I went to the truck to get a shovel, but by the time that I had gotten back the stinger on the Ditch Witch was wrapped up in an array of multicolor wires from the cable. Kinda reminded me of a Christmas tree... He had hit a one thousand pair cable that carried the long distance calls from Colorado Springs to Denver. As well as being used for communications to and from Norad. So yeah, not a good cable to have an accident with... Ma Bell (Mountain Bell) employees started popping up like popcorn all over the place. They were easy to spot, white shirts, black slacks, and all with unpleasant looks on their faces. The downtime was $1,000 a minute. The bonding company refused to cover the damage, citing "stupidity". That was the end of his company, and much of his personal possessions. My boss did a back door deal with him to buy his Ditch Witch so that he could have a bit of cash to live off of until he could sell his house to cover (a portion of) the damages. Ma Bell wasn't taking any prisoners on this one. He offered to help cut a new ditch, which had to go thirty or forty feet in both directions from the damaged spot (you have to remove a large section because the wire insulation gets ruined closer to the cut). The Ma Bell splicers said "Thanks, but you've done enough". The first thing that the splicers did when they had their new ditch dug, was to dig out "thrones" for themselves in the wall of the ditch to provide a place for them to sit while they made their splice. Pretty obvious to me that they were going to be there for awhile. It took them thirty hours to splice in a new section.
@TimWilborne
@TimWilborne 4 года назад
@@MrWaalkman Yes I knew I guy that hit one of those 1000 pair cables. Not fun.
@atrank
@atrank 4 года назад
I have a sub panel in a garage, fed by 4 wires (2 hot, neutral, and ground). The neutral bar in the sub panel is not bonded to ground and I believe/read it should NEVER be bonded in a sub panel. I have 3 things attached to the sub panel- a three prong outlet for a compressor, an air conditioner (3 wire), and an electric garage heater (3 wire). All are 240v (or 220?). I do not have a separate grounding rod for the sub panel. The sub is 4 feet from the main panel and I added a grounding bar to the sub panel. *****The question is... should the ground for each of the 3 connections be connected to the ground bar or neutral bar in the sub panel? I cannot find the answer anywhere!!! Thanks!
@TimWilborne
@TimWilborne 4 года назад
Ground should always be connected to ground. Ground is a non current carrying conductor. Neutral is a current carrying conductor. Never mix them up.
@atrank
@atrank 4 года назад
@@TimWilborne thanks!
@daniielzarate
@daniielzarate 4 года назад
Hello Tim So I would like to know if it legal and not against the code to come out from a 200A 208y/120v 3phase panel to a 100A 208y/120 single phase?
@TimWilborne
@TimWilborne 4 года назад
Yes it is legal but reach out to a local Electrician so you can get the details right
@blackseabrew
@blackseabrew 3 года назад
I'm and automation engineer who live on a farm. Been upgrading wiring and panels. The most recent of which was installed almost 50 years ago when I was three. One question...why does the ground rod need to be at least 6' from the panel? As in what's the real purpose of the distance? Not the NEC answer.
@TimWilborne
@TimWilborne 3 года назад
Where does it say that in NEC code? It is suppose to be a few feet from the structure, I assume so it is truly grounded and not up against the footers of the building and if you have two ground rods then they must be 6' apart, but I've never heard that they have to be 6' from the panel.
@richardmclendon8314
@richardmclendon8314 4 года назад
Can I run a subpanel from another subpanel? I have a subpanel about 20 feet from where I want to install one. My main breaker panel is about 100 feet away.
@TimWilborne
@TimWilborne 4 года назад
Probably but your should get an electrical to have a look to determine if you can for sure
@Stevenyoung100
@Stevenyoung100 3 года назад
Literally the best teacher.
@TimWilborne
@TimWilborne 3 года назад
Thank you Steven!
@pramodkarande9855
@pramodkarande9855 4 года назад
What is gfci outlet
@TimWilborne
@TimWilborne 4 года назад
Gound Fault Circuit Interrupter... Depending on where you are located they may be referred to as a Residual Current Device.
@Montanafield
@Montanafield 3 года назад
When running the feed from main panel to sub panel is the conduit required if inside wall?
@danschuster5187
@danschuster5187 3 года назад
I didn't know u knew electrical too my man
@TimWilborne
@TimWilborne 3 года назад
Just the basics, not the art of doing it like an everyday electrician :)
@mipuntodevista3988
@mipuntodevista3988 3 года назад
Question: Is it ok to add a subpanel to the main panel even so the main panel does not have a main breaker? Hope my question makes sense. Thanks in advance!
@wiley0714
@wiley0714 2 года назад
Your main panel would have a main breaker. Then in your main panel you would install another breaker which would send power to your sub panel. If you put in a 200 amp panel you would have two 100 amp breakers. On one leg of that panel you could install let's say a 50 amp breaker and then run power from that into a subpanel.
@masterroaster1109
@masterroaster1109 4 года назад
So I'm running a 12/2 to a 20 amp in my sub, do I connect white and black to the breaker screw and the ground bar?
@masterroaster1109
@masterroaster1109 4 года назад
And the ground to the ground bar?
@TimWilborne
@TimWilborne 4 года назад
No. You should consult an electrician before proceeding. It will be a small price to make sure you don't burn anything up.
@bradleycoles8273
@bradleycoles8273 3 года назад
what size subpanel are you using in the video?
@marlpierre8985
@marlpierre8985 Год назад
100
@marlpierre8985
@marlpierre8985 Год назад
100
Далее
How to Install and Wire a Sub Panel
35:23
Просмотров 1,3 млн
How to Install a Subpanel
12:36
Просмотров 1,3 млн
How To Install A Garage Sub Panel
28:27
Просмотров 386 тыс.
How to Wire an Electrical Panel - Square D
9:40
Просмотров 3,3 млн
Wiring a Tiny House Sub Panel
23:02
Просмотров 66 тыс.
How To Install A Sub Panel Next To Existing Main Panel
16:01