Тёмный

How to Wire-Up a Yaskawa V1000 AC Drive 

GalcoTV
Подписаться 125 тыс.
Просмотров 248 тыс.
50% 1

How to wire up a Yaskawa V1000 AC Drive presented by Katie Nyberg for Galco TV. Buy the items featured in this video at 800-337-1720 or visit: www.galco.com/shop/V1000-Yaska...
The V1000 is a world‑class compact current vector drive that defines a new world standard. Demands for efficient production and better maintainability are on the rise, spurred by global competition. Yaskawa drives have earned a reputation for high performance, high functionality, and high quality.
To find the full line of Yaskawa Products visit: www.galco.com/find/Yaskawa?sou...
Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/email/
Connect with us!
plus.google.com/+GalcoIndustrial
/ galcoindustrial
/ galcoindustrial
/ galcoindustrial
/ galco-industrial-elect...
Don't forget to like and comment on this video, and subscribe to our channel!
Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
www.galco.com/safety
With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.
LEGAL DISCLAIMER:
While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.

Наука

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 69   
@JaykeSapalaran-iq3qs
@JaykeSapalaran-iq3qs Месяц назад
Great video tutorial very informative and easy to understand, Thank you for sharing your knowledge,❤️🇵🇭
@mostafaradwan3826
@mostafaradwan3826 9 лет назад
Very helpful , Thanks
@sampetrosyan5334
@sampetrosyan5334 9 лет назад
Good job. Thank you
@joseaguirre2055
@joseaguirre2055 5 лет назад
Would be great if you guys made the communication video too
@smartydebansi
@smartydebansi 5 лет назад
thank you
@ashishlalpd7152
@ashishlalpd7152 3 года назад
Hai , If we want more than two speeds in our application like 10%,20%,30%,40%,50% how the wiring should do on the drive.. Looking forward to your support.
@imranaslam9688
@imranaslam9688 8 лет назад
dear sir there is no load connected to the drive . when ever i push the run button it shows oc . i think the fualt may be in the hardware . can you pleas tell me which ic refers to the current detection ???
@lct9031
@lct9031 4 года назад
hi there... is it possible to use the analogue output of 1st drive and connect it to the analogue input of the 2nd drive for PID control? i would like the speed of the 2nd drive to change according the the amps of the 1st drive
@pauloyoshizaki2103
@pauloyoshizaki2103 2 года назад
Yaskawa - Robótics - Automação - Globalizado - Future - Global .
@ahmeraslam9276
@ahmeraslam9276 3 года назад
How to run source mode run reverses direction in my case only running forward direction
@Electrical-Automation
@Electrical-Automation 5 лет назад
How to remove ope03 error during up down command set
@FurkanAli-ih9dp
@FurkanAli-ih9dp 5 лет назад
Emergency terminal Dirac me kon se hote ha
@bismillahelectronicsindust9824
@bismillahelectronicsindust9824 4 года назад
Hi medam i have yaskawa drive v1000 fault is cpf06 can you tell me thanks
@fahimasghar6375
@fahimasghar6375 5 лет назад
Nice video Miss.but if it's possible to draw a control diagram to understand more easily. Thanks
@abhirupbera804
@abhirupbera804 3 года назад
A1000 vfd Default analog output is 0-10v. How to change it to 4-20mA?
@josephferraris
@josephferraris Год назад
Thank you maam,how to wiring a L1000a maam?
@JaskaranSingh-cr6wd
@JaskaranSingh-cr6wd 8 лет назад
sir, may u tell me what is the use of photocoupler and pulse train input and outputs in v1000 please
@GalcoIndustrial
@GalcoIndustrial 8 лет назад
+Jaskaran Singh The photo coupler outputs can be programmed to turn on a transistor based on a status of the drive, such as DRIVE IS RUNNING or DRIVE IS AT ZERO SPEED for example. This output signal could be used to turn on a light or give a signal to a PLC for example. The pulse train input is used to control the output of the drive or as a feedback signal. This pulse train could come from an encoder that is turned by a different part of the machine for example, then the drive output could match the speed of the encoder. The pulse train output provides an high frequency output that that can be programmed to show a monitored value of the drive such as output frequency for example. This signal could be used to feed another V1000 drive’s pulse train input so that it will match the speed of the first drive.
@What-is-thehandle
@What-is-thehandle 5 лет назад
Hello Galco! Thank you for making this video's you've made a customer out of me! Im starting frim scratch on a milling machine. I need to put together a complete control panel from scratch. can you please make a video going over configuring it this vfd for milling machine application? Thanks! i ask because i just purchased this drive to replace a faulty drive on a mill at work. The settings for the old 90's yaskawa drive don't translate well to the updated drive. Stuff like acceleration time, deceleration time. Braking ect. Id hate to set my DC braking wrong and de-magnitize the expensive spindle induction motor. Maybe I can get an email to send a copy of the machine specifications for the drive settings to have help help translating them?
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
It sounds like you have taken on an extensive project that would be well beyond the scope of our videos, so we probably won't be able to make a video for that kind of instruction, cuz it would have to be hours in length and as you may have noticed most of our video's are only 2 to 6 minutes in length. For that kind of help you would need to talk to 1 of our engineers or a product manager may also be able to help. Give us a call at 800-337-1720 and ask for our Yaskawa product manager.
@parveennarwal4119
@parveennarwal4119 2 года назад
Hii miss How to remove ope01 alarm fault yaskava v1000
@Miralstorycorner2
@Miralstorycorner2 8 лет назад
sir plz can you tell that how to clear a "call" fault communication transmission error appear when drive power on
@GalcoIndustrial
@GalcoIndustrial 8 лет назад
+ahmad rehman do you have have serial communications connected to the drive? Here is a link to the technical manual, www.galco.com/techdoc/yask/v1000_tc.pdf, if you go to page 255, it list possible causes for that alarm. On page 397 it shows how to perform a self-diagnostics test of the communications in the drive to confirm the drive is good.
@addagarlabalaram4739
@addagarlabalaram4739 6 лет назад
Naku drive vfd contactor tho wiring kavali
@CM-oy2kd
@CM-oy2kd 5 лет назад
Thanks
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Welcome
@richiepadilla5611
@richiepadilla5611 6 лет назад
When i connect s1 to sc becomes reverse direction instead forward direction ...why? s2 to sc It reverse direction in properly
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
To correct motor rotation usually all you have to do is to swap any two motor leads.
@ramanaidu3049
@ramanaidu3049 6 лет назад
Please enter avery parameters. And wiring .
@simeonson6162
@simeonson6162 5 лет назад
If i put a push button who springs back on S1 how can i manage it that the motor keeps on spinning until i press a off button?
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Look up the "3-wire" start/stop configuration and wiring in your user manual.
@LamNguyen-um4tq
@LamNguyen-um4tq 6 лет назад
excuse me! Can you send the diagram which you connected between the Inverter and External equipments in this video to me, please! Thanks the best.
@LamNguyen-um4tq
@LamNguyen-um4tq 6 лет назад
my gmail address is: Forestkhanh@gmail.com.... Thank my gorgeous woman!
@imranaslam9688
@imranaslam9688 8 лет назад
sir can you please tell me how oc fault can be repaired ???
@GalcoIndustrial
@GalcoIndustrial 8 лет назад
+Imran Aslam An OC fault is an overcurrent fault, this can be caused by many factors. This could include motor load issues, the motor itself, wiring, drive parameters or a defective drive. If the drive had been running fine for a period of time and no parameters have been changed, you can assume that it is not a parameter issue. If the drive is set-up to run in V/Hz mode, I would suggest disconnecting the motor from the drive and then start the drive. If the drive still faults out on OC, typically that means the drive is defective. If the drive doesn’t fault out, with the motor still disconnected, I would testthe motor and wiring to ground using a megger. This will check to see if anything is breaking over to ground with high voltage. If that tests good, I would try to run the motor with the it uncoupled from the load. Measure the current, using a true RMS or an analog current clamp, on the three output wires to make sure they are balanced and below the full load amps of the motor. If that looks good, reconnect load and re-measure the current to make sure it isstill below full load amps of the motor. If the drive faults and the current is below the full load amps of the motor the drive could be defective. If the current is above, then check the load on the motor. See the Yaskawa manual for more information on possible causes for an OC fault.
@taiapple5999
@taiapple5999 7 лет назад
thanks you...
@deankoch7305
@deankoch7305 2 года назад
When your boards fail what makes you feel like you doing anything for anybody in this situation?
@thakorjagdish8759
@thakorjagdish8759 6 лет назад
Please sir potentiometer connection in the drive
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Connect the wiper to terminal A1, the clockwise end to V+, and the CCW end to VC, ok?
@dutrung2546
@dutrung2546 5 лет назад
What fault ope12, thanks
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Is not listed in the manual so you will have to give us a call at 800-337-1720 and ask for a product manager or contact the factory directly.
@whitneyhurt194
@whitneyhurt194 6 лет назад
Are the control inputs 24vdc or 110vac?
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
The inputs directly to the drive terminals are 24 volt. However a 110Vac option card is available if needed.
@whitneyhurt194
@whitneyhurt194 6 лет назад
GalcoTV thank you
@tendaimtizva6404
@tendaimtizva6404 Год назад
wire with cct with diagram alongside
@diegoantonio7142
@diegoantonio7142 7 лет назад
excuse me, i need use the potentiometer to control a C.A motor whith yaskawa v1000. first I need to configure the parameters current, voltaje, RPM, Frecuency. in yaskawa and then operate in remote mode??? thanks
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
OK Diego, go to parameter E1-01 and verify the line voltage set correctly for your application, E1-03 = 1 (by default for 60Hz motor) be sure you have correct V/F pattern selected, then go to E2-01 load motor rated current (FLA), E2-04 for number of poles, and E2-11 for motor rated power in KW. Now you want to run a rotational Auto-tune, just make sure your motor in not coupled to the machine before running autotune, ok?
@srinathvenkatesha8273
@srinathvenkatesha8273 7 лет назад
please help us to configure VFD with computer interface
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Ok the drive uses RS422/485 with MEMOBUS protocol (the manual shows MODBUS next to the memobus labeling too). Do you have the software?
@srinathvenkatesha8273
@srinathvenkatesha8273 7 лет назад
Yes I have
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Ok well with most startup you load your motor data first, determine a reasonable ACCEL/DECEL time for you application, program max speed and then you probably want to Autotune it.Is the motor uncoupled from the machine?
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Let us know how you make out, ok?
@srinathvenkatesha8273
@srinathvenkatesha8273 7 лет назад
it is not detecting the drive
@niels1497
@niels1497 3 года назад
Please crimp your cables appropriately next time. Do not use bare strands in screw terminals.
@pablojosealvarezalvarez5671
Por favor en español
@lilxeno8778
@lilxeno8778 6 лет назад
اريد الترجمه للعربيه
@mahmoudradwan1040
@mahmoudradwan1040 5 лет назад
يا ريت أريدها مثلك
@user-zz2px9kn1x
@user-zz2px9kn1x 6 лет назад
Можно перевод
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Не все видео, но если у вас есть вопросы, да, мы можем помочь на любом языке
@Godor1
@Godor1 4 года назад
Lady is very pretty, it is hard to concentrate on drive itself.
@MR-nl8xr
@MR-nl8xr 7 лет назад
2:11. WARNING: To everyone using Remote Inputs with a Potentiometer to control their equipment with a Yaskawa VFD. Make sure you look at your Yaskawa VFD's Control Circuit Diagram (it is available in the first few pages of your Yaskawa VFD Manual) to find what Ohms level Potentiometer it NEEDS. If you use a Potentiometer with a different Ohm's level than what the Yaskawa VFD NEEDs, you could BURN YOUR MOTOR at motor start up.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Our manual shows a 2K ohm Potentiometer for the V1000 . Max did you damage your motor with this drive?
Далее
Yaskawa V1000 Motor Parameter Setup
2:52
Просмотров 94 тыс.
How to Wire Up an ABB ACS150 Drive
5:43
Просмотров 181 тыс.
Yaskawa A1000 AC Drive Basic Start Up Using the Keypad
9:45
YASKAWA V1000 SÜRÜCÜ HIZLI DEVREYE ALMA
11:46
Просмотров 23 тыс.
Industrial Control Panel Basics
5:58
Просмотров 757 тыс.
How to troubleshoot and diagnose a non-working VFD
8:49