Тёмный

How to Wire Up an ABB ACS150 Drive 

GalcoTV
Подписаться 125 тыс.
Просмотров 181 тыс.
50% 1

How to Wire Up an ABB ACS150 Drive presented by Katie Nyberg for Galco TV.
Buy the items featured in this video at 800-337-1720 or visit: www.galco.com/shop/ACS150-ABB-...
Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/email/
Connect with us!
plus.google.com/+GalcoIndustrial
/ galcoindustrial
/ galcoindustrial
/ galco-industrial-elect...
Don't forget to like and comment on this video, and subscribe to our channel!
The ACS150 provides additional capability and range to support small AC induction motor and machinery applications. The acs150 has an easy to use operator interface and is simple to set up, configure, and apply. ABB component drives meet the requirements of OEMs, system integrators and panel builders. The drive is ideal for food and beverage, material handling, rubber and plastics, and woodworking applications.
Features of the ABB ACS150:
- General Purpose
- Volts/Hertz Control
- 0.5 to 3hp 240V, to 5hp 480V
- 1 & 3-Phase Units
- Protected Chassis (IP 20)
Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
www.galco.com/safety
With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.
LEGAL DISCLAIMER:
While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.

Наука

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 97   
@TipuSultan-bf3om
@TipuSultan-bf3om 5 лет назад
very good explanation
@dehyaasultan5826
@dehyaasultan5826 7 лет назад
thanks for this video
@sshashlan
@sshashlan 9 лет назад
Thanks for the show, and keep these tutorials coming
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Welcome
@EricP36
@EricP36 9 лет назад
Good video!
@jacoboborjas8601
@jacoboborjas8601 5 лет назад
excellent video thanks
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Thanks
@traiazeddine
@traiazeddine 3 года назад
Thanks a lot, Madame.
@bestgrover007
@bestgrover007 8 лет назад
nice video
@PiyushKumar-jd3ou
@PiyushKumar-jd3ou 3 года назад
nice video 👍👍👍👍
@bijaneshkumarbrman9432
@bijaneshkumarbrman9432 5 лет назад
All videos good
@Hasifariff
@Hasifariff 5 лет назад
Hi.i have this installation for small motor.it uses 1-phase incoming supply and outgoing 3- phase.How does it happen?Is there any transformer intergrated in this ACS 150?
@jacoboborjas8601
@jacoboborjas8601 5 лет назад
have a nice day
@jacoboborjas8601
@jacoboborjas8601 5 лет назад
thanks my vdf working very well
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Glad we could help
@Rajput-kb5in
@Rajput-kb5in 6 лет назад
When I press reverse pushbutton its shows REV on the acp and I get 24v on DI2 but the motor doesn't run in reverse direction. Any solutions please?
@jorgecharca5103
@jorgecharca5103 3 года назад
Muchas gracias por compartir sus conocimientos y experiencias. Mi preguntas es ¿ que pasa si a la electrobomba lo hago trabajar con un presostato y no con el variador de frecuencia? una vez mas gracias por su respuesta.
@ibrahimgungor6101
@ibrahimgungor6101 3 года назад
thanks you
@cthor64
@cthor64 3 года назад
The manual seems to indicate the relay output can be wired for 230v, but its not clear how this is done. The 24vdc is covered here, but I’m hoping to use this relay yo run a very small pump (less than .5A). I have this ACS150, single PH 230v input, output 240v 3ph to 3HP motor. When I pull the trigger (remote button on saw arm) I want to use this relay to fire the pump, just like lighting a “running light”. Any ideas,
@FarhanAli-ns5xb
@FarhanAli-ns5xb 7 лет назад
very nice
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Thanks!
@mamunmahmud314
@mamunmahmud314 5 лет назад
Thanks
@danieljuanbarrueta1565
@danieljuanbarrueta1565 2 года назад
HELLO THERE. IF I ONLY USE THE START/STOP INPUT IN REMOTE MODE, WILL I BE ABLE TO USE THE DRIVE´S POTENCIOMETER ?
@kesavachawali5807
@kesavachawali5807 4 года назад
If there is a fault, the supply to the motor is cut off due to the OLR in my power circuit. Then how does the red indicator bulb glow? When there is no power to the VFD?
@daveinarmstrong
@daveinarmstrong 3 года назад
I would like to purchase a potentiometer to remotely control the speed of this unit. Where do I find the specs for this potentiometer?
@abdelhalimsetif5449
@abdelhalimsetif5449 4 года назад
Hi I'm looking for analog output wiring (motor speed)
@raymondlekalakala8404
@raymondlekalakala8404 10 месяцев назад
Heaven on earth
@malekrizwan4993
@malekrizwan4993 7 лет назад
super
@pluspoint5171
@pluspoint5171 6 лет назад
please make video about flowneter setting
@pluspoint5171
@pluspoint5171 6 лет назад
thanks
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Welcome, glad you liked it
@blachfordm
@blachfordm 7 лет назад
Where does Katie connect the +24V Source to in her setup? Trying to wire up the ABB ACS150 for a momentary contact paddle switch.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
5th terminal from left should be the +24volt output but you will also need a jumper from com to gnd so you can use the internal 24volt supply for your inputs.
@junaidahmad1454
@junaidahmad1454 3 года назад
Can you please tell me in comment box for the third common wire of both led
@maicon6437
@maicon6437 6 лет назад
muito bom
@runbou3485
@runbou3485 Год назад
THANK
@omkarmalvankar7657
@omkarmalvankar7657 4 года назад
How to select vfd for motor can you guide
@suriyabala5860
@suriyabala5860 4 года назад
I am using this vfd ,,and vfd display is not working , how to repair ,are installed another display ,,pls explain
@ashkirkwood315
@ashkirkwood315 7 лет назад
Is this machine suitable for a 5 pin UK 3 phase plug? 3 Phase + N + E.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Yes this drive can be used in the UK, it meets all US, UK and European stardardsWe suggest connecting the Neutral and Earth ground wires together at the drives chassis ground terminals. Connect the line phases L1, L2 and L3 to U1, V1 and W1 terminals on the drive only. There is also an EMC filter built into the drive, depending on your particular power feed system, you may want to change the plastic screw to metal screw to connect the EMC filter and make it active. Hope this helps.
@deepak9640
@deepak9640 7 лет назад
i had installed pot but it is not controling, which parameter should i change that speed could be controled by pot and i am using acs5050-01-045a-4
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Ahh well let me assume that you mean the ACS550, because there is no such drive as ACS5050, ok? The drive defaults to the Analog input 1 or AI1 at X1 terminals 2, 3, and 4. Do you have a copy of the User manual for this dirve?
@deepak9640
@deepak9640 7 лет назад
yes it is acs550. i had downloded its user manual from abb website.It was running on remote mode by using speed pot but person who was handling this drive before me had done something to it and now pot is not working some parameters are also missing i can only change rpm by drive keypad prameter 11 ,1105. please help
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Ok if you have keypad ACS-CP-A first make sure you have the "REM" symbol in the upper left corner of the display, (remote mode) if not simply push the LOC/REM button to put back into remote mode of operation. If still doesn't work you may have to default the drive.
@StupidPeasant
@StupidPeasant 6 лет назад
What does U and I stand for on the input switch?
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
The U stands for voltage input (0-10volt input), and the I makes it a current input (0-20ma).
@magdalenafortaleza404
@magdalenafortaleza404 5 лет назад
can somebody tell me what is the part number of the motor?
@mochprianto5561
@mochprianto5561 4 года назад
How to fix alarm a5031
@electricaltech4u45
@electricaltech4u45 6 лет назад
What is digital input & analog input plz mention. thanks
@sircmanaloto1296
@sircmanaloto1296 5 лет назад
digital input is the contact from relay or switch, analog input is either voltage or current which comes from sensors analog outpur or other devices has analog output..
@electricaltech4u45
@electricaltech4u45 5 лет назад
@@sircmanaloto1296 thanks
@jacoboborjas8601
@jacoboborjas8601 5 лет назад
hi I like your video I would like to know how to connect a potentiometer to use it remotely thanks
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
The Speed pot can easily be wired remotely , just make sure you use shielded cable and only ground the shield at the drive's chassis ground, ok?
@cheickdembele4303
@cheickdembele4303 5 лет назад
Hi i'm a i want to ask you What's the definition of GND ?
@CarloshGonzalez
@CarloshGonzalez 5 лет назад
Ground
@muhammadawais6336
@muhammadawais6336 5 лет назад
hi thier was any job in uae on goloco service center
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Not sure what you are asking, can you ask a different way?
@mssolarcompanylodhran3881
@mssolarcompanylodhran3881 5 лет назад
Hello! Frome where has nc/no indicator negative wire tekena? Please replay me.
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Forgive us, but your question makes no sense, can you ask in a different way?
@seimela
@seimela 2 года назад
i have purchased two Si-EtherCat modules from Galco they gave me ,they gave 67 lead time ,i waited ,after 67 days they say i will only get them in January 2023 ,i have requested refund to no avail ,i need help
@Lo7q7le7guste7mrtf
@Lo7q7le7guste7mrtf 4 года назад
Huh. So you don't need to bolt the motor down to see if it works or not. I was taught to always bolt it down. But I guess it's only really needed when it actually has some working load to it. To stop it from going around.
@SuperSameer333
@SuperSameer333 7 лет назад
hello Katie i am not able to start this drive,is it necessary to connect AI I have connected 3 phase mains & motor connection but drive not starting
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Hello, Is the drive in local or remote mode, and have you attempted to configure the drive yet?
@SuperSameer333
@SuperSameer333 7 лет назад
no,actually i am not able to start the drive,I mean please tell me how to start the drive,I have ABB ACS 150 drive,0.75KW ABB make AC motor,3 phase supply,is there anything else to start the drive
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Hey, We'll help you get your drive up and running, so we'll start with some questions for you and work from there. Let’s start with “Does display light up?” If so, look for “LOC” in upper left corner of display. If says REM, push the LOC/REM button to indicate LOC. Then push the start button (with green symbol on it) and turn up the speed pot on face of the drive. If it still doesn’t run, then what does the display say, is it faulted?
@SuperSameer333
@SuperSameer333 7 лет назад
thank you galco. only display light up,it shows nothing.its a new drive.
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Ok Shrikant, So this means that you do not have the drive wired up yet, correct? Is the drive mounted yet? Line Power leads to U1 V1 W1, ground wire to chassis terminal. Motor leads to U2 V2 W2, ground wire to chassis terminal. Do you have a manual available? We can link you to one if you need it.
@metinkara8488
@metinkara8488 3 года назад
👏👏👏👏👏👏🙏
@junaidahmad1454
@junaidahmad1454 3 года назад
In this video you didn't tell us the third wire of both led where we connect
@chihiaaymen2189
@chihiaaymen2189 7 лет назад
Comment brancher et programmer une bouton RST externe op Mercie d'avance
@chihiaaymen2189
@chihiaaymen2189 7 лет назад
Pour un variateur abb acs 150
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Avez-vous une copie du manuel?
@sunillohani5757
@sunillohani5757 6 лет назад
Please help me for overcoming the error -F0035 in ACS 150
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Looks like you have a problem with your output power wiring. Please verify you have the input line power connected to U1 V1 W1 and motor leads connected to U2 V2 W2, very critical. If ok then verify your grounds are connected per the manual recommendations.
@sunillohani5757
@sunillohani5757 6 лет назад
I checked input supply between R & Y =398volt, Y &B =398V and B&R =405 V. But this error continue after a fraction of minutes
@sunillohani5757
@sunillohani5757 6 лет назад
I also disconnected output wires which were for motor but still condition was same
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Please reference the terminal numbers
@sunillohani5757
@sunillohani5757 6 лет назад
Input power supply OK
@bilalbelkacem4903
@bilalbelkacem4903 3 года назад
problème dans la carte de puissance (rint) de abb
@ConservTab-sv3kx
@ConservTab-sv3kx 5 лет назад
Am I at Disney world
@magdalenafortaleza404
@magdalenafortaleza404 5 лет назад
Im in a whole new world with you...
@hamadagdoo2010
@hamadagdoo2010 4 года назад
U1/L V1/N W1 380 or 220 ?
@benachourmahmoud732
@benachourmahmoud732 5 лет назад
Comment reset alarme Fault F0035
@mehmeteminyagmahan428
@mehmeteminyagmahan428 Год назад
who is name this women?
Далее
ABB ACS 150 Two wire connection and parameters
14:30
Просмотров 22 тыс.
СМОТРИМ YOUTUBE В МАЙНКРАФТЕ
00:34
Просмотров 630 тыс.
ABB ACH580 HVAC Drive Basic I/O Connections
5:01
Просмотров 10 тыс.
How to Wire-Up a Yaskawa V1000 AC Drive
5:20
Просмотров 248 тыс.
How to install the ACS355 machinery drive
3:43
Просмотров 92 тыс.
How To: Troubleshoot VFDs
11:30
Просмотров 30 тыс.
What is the Difference between VFD and Soft Starter?
7:30
ABB ACS-150 AC Drive Basic Start Up & Operation Demo
5:00
КРУТОЙ ТЕЛЕФОН
0:16
Просмотров 7 млн
Что стало с Windows Phone?
0:43
Просмотров 265 тыс.