Тёмный
No video :(

HVAC 082 Liquid line Receiver, King Valve 

Love2HVAC with Ty Branaman
Подписаться 50 тыс.
Просмотров 20 тыс.
50% 1

hvacrschool.co...
www.achrnews.c...
• Liquid Receiver Tank F...
sporlanonline....

Опубликовано:

 

22 июл 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 51   
@archiearon654
@archiearon654 3 года назад
Aha! So THAT'S how a receiver it looks on the inside!.. These cut out components really add value to your videos! Makes it more interesting and easier to understand how the components work. Thank you once again for your awesome videos. More power to your channel.
@love2hvac
@love2hvac 3 года назад
For me the pictures in the book never did it justice. I would cut it open to see for myself. I'm glad you like it.
@unknownsf0
@unknownsf0 2 года назад
Couldn’t agree more on this !
@mike-yp1uk
@mike-yp1uk Год назад
Wow I can watch this content instead of tv I actually do. The level of knowledge just intrigues me as I enjoy learning how stuff works
@svensudels1
@svensudels1 5 месяцев назад
Thank u so much for cutting into this equipment and showing us how it actually works inside. Very informative. Thank u again for making these videos!
@stuzman52
@stuzman52 3 года назад
Good tip Ty about loosening the packing nut before opening the valve.
@faithraisemeup7749
@faithraisemeup7749 Год назад
Thank you for the video. It helps me to understand what is receiver and king valve.
@unknownsf0
@unknownsf0 2 года назад
Great video, this is awesome! I just made a video on the cycle and it was great hearing you talk about different ways of subcooling liquid.
@wtfman5313
@wtfman5313 3 года назад
I've used a liquid receiver from a decomm'd unit for years to seperate oil from refrigerant when recovering large systems. Worked pretty dern good.
@love2hvac
@love2hvac 3 года назад
thats a great tip. I cut open a recovery tank recently. I was surprised at how much oil was in the bottom!
@CHOMAHOMA
@CHOMAHOMA Год назад
Always great and very relevant information given on this channel. Thank you.
@love2hvac
@love2hvac Год назад
Thank you!
@broncheemims8493
@broncheemims8493 3 года назад
Thanks for explaining liquid line receivers
@victorleon1563
@victorleon1563 3 года назад
I've installed a lot of freezer rooms and cold rooms with out a reciever. No need for them (not all ways)- nice clear sight glass and no problems with pump down.
@speciosa146
@speciosa146 3 года назад
Thank you Ty for these great videos, could you show of more of that see-through refrigeration system. Thats really cool.
@love2hvac
@love2hvac 3 года назад
That belongs to Lake Tech college in Eustis Florida. Courtesy of Bryan Orr. Here is the another view of it ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-kXRASGrst8o.html
@speciosa146
@speciosa146 3 года назад
@@love2hvac Thats fantastic, thank you. Can you tell me a little about that low side float valve? Ive never seen one of those before and dont really understand how it works.
@knavin813
@knavin813 5 месяцев назад
informative Thanks!
@mzdriss
@mzdriss 2 года назад
awesome can't thank you enough
@huamincai9888
@huamincai9888 2 года назад
Amazing work! Thanks a lot.
@LivingInWild
@LivingInWild 10 месяцев назад
So, the king valve is in the back sitting position while the system is running. And to inject the refrigerant and also detect the system pressure, I have to make it mid sitting. After the injection was done, the king valve should be in the back sitting position, then disconnect the charing hose? Is my interpretation correct?
@love2hvac
@love2hvac 9 месяцев назад
Yes that is correct. Remember mid seat is usually less than 1 full turn
@tonyp6088
@tonyp6088 2 года назад
Legend!
@rickadams6285
@rickadams6285 3 года назад
Great videos, you spoke of brazing low side to high side to lower liquid line temp, does this increase capacity?
@love2hvac
@love2hvac 3 года назад
Some call it a heat exchanger, others a subcooler. It dosen't increase capacity but transfers energy from one side to another. There is arguments on both sides. I can discuss some of the ideas but it really gets into engineering. Too much to type out .
@MrHarbinged
@MrHarbinged 3 года назад
@@love2hvac Would be a nice video idea.
@rickadams6285
@rickadams6285 3 года назад
OK I understand, so if the low side is brazed to high side to transfer heat as you say, it would be very critical when measuring for subcooling you make sure you take temp before this point where the 2 lines are brazed together other wise you would not get true subcooling ?
@al-ameenallu9927
@al-ameenallu9927 2 года назад
Ty,actually how liquid refrigerent is pumped from large receiver to expansion device as size of tube inside through which liquid flow to expansion device is very small compared to receiver area...is it because of capillarity? Or due to high pressure due to compression.
@love2hvac
@love2hvac 2 года назад
High pressure if compression pushes into the receiver, that pressure pushes against the liquid, the liquid is pushed threw the liquid line to the metering device. The 3/8 line is plenty big to handle the liquid. It's usually foot till 7.5 ton
@zackwalker2642
@zackwalker2642 Год назад
How can you tell if its 80 percent full, if its not see through?
@love2hvac
@love2hvac Год назад
Using a heat source and a thermal imager
@DanO181919
@DanO181919 2 года назад
Question… if you get a burn out on a compressor (system tested positive for acid) do you recommend replacing the evap due to acid in the system? Also, do you recommend using a Rx-11 flush on the lines set once the evap and the coMpressor has been removed. Last question… can the Rx-11 flush clean out the receiver appropriately or do you suggest changing out the receiver too. Thanks.
@love2hvac
@love2hvac 2 года назад
Great questions. Your best bet is an oversized liquid line filter drier and suction line drier specifically for acid cleanup. You will have to return every 72 hrs until it's cleaned. If you where replacing the systems I would recommend a lien set cleaner that shoots a pig through similar to hilmors set. I would not recommend Rx-11 especially in the evaporator, or receiver, because it is very difficult to remove the product. That can be more of an issue than the acid. Some manufacturers have bulletins especially against the use of the product. If you have a suction accumulator it should be replaced with the compressor. There is a screen inside that clogs up. A liquid receivers is not required to be replaced as the filter drier is after it allowing protection. There is also a product called acid scavenger. However I recently learned it can also cause other issues because of how it chemically reacts.
@DanO181919
@DanO181919 2 года назад
@@love2hvac Thank you!!
@chrisleon7312
@chrisleon7312 2 года назад
Does the refrigerant sit on top of the oil or the other way around? If the oil sits on top of the refrigerant, the oil would never find it's way back to the compressor if there's always refrigerant in the LL receiver.
@love2hvac
@love2hvac 2 года назад
Most of the time the oil is missed with the refrigerator, but when it's not the oil will be at the bottom.
@chrisleon7312
@chrisleon7312 2 года назад
@@love2hvac I'm sure you meant 'miscible' and 'refrigerant', but hey, not everyone payed attention at school...
@fabiodarocha2842
@fabiodarocha2842 3 года назад
Ty. Liquid line receivers are for commercial units only right!
@netochangs
@netochangs 3 года назад
Some air conditioner they have Liquid line receiver
@fabiodarocha2842
@fabiodarocha2842 3 года назад
@@netochangs residencial ones?
@love2hvac
@love2hvac 3 года назад
Yes micro channel residential condensors sometimes have receivers
@shine-cg9uf
@shine-cg9uf 3 года назад
When dealing with liquid receivers on walkin coolers/freezers can I take the temperature at liquid line n b4 receiver to get a subcooling temperature? I hear guys say u can't take subcooling with receiver but dick wirz has a great book commercial refrigeration for ac techs n his diagrams show temp probes at condenser outlet n b4 receiver. So I'm curious why I hear u can't or shouldn't take subcooling temperature with receiver in system.
@love2hvac
@love2hvac 3 года назад
hvacrschool.com/subcool_receiver/ I think this explains it best. Dick Wirz is a great guy. Subcooling with a receiver can easily lead to a flooded receiver. Check out the article, and I will look for Mr Wirz example your talking about.
@shine-cg9uf
@shine-cg9uf 3 года назад
@@love2hvac chapter 7 troubleshooting. Basically shows diagrams of wer to put temp probes for subcooling reading. No mention of why not to do this. Thanks ty appreciate ur feedback. Thanks 👍
@sparkyedu
@sparkyedu 4 месяца назад
dude is Australian don't sound Australian sounds American
Далее
HVAC 083 The 3 position service valve
10:41
Просмотров 22 тыс.
HVAC  069 suction line accumulator
12:34
Просмотров 22 тыс.
HVAC 106 Scenario Restriction and non-condensable
14:02
HVAC SERVICE VALVE LEAKING
8:11
Просмотров 12 тыс.
Advanced Refrigeration - Charging
16:38
Просмотров 83 тыс.
HVAC 093 Flash gas revisited with a deeper view
14:48
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
DIY Vapor Compression Refrigeration System
28:06
Просмотров 1,1 млн
What is a King Valve?
4:20
Просмотров 39 тыс.
HVAC Suction Line Accumulator Tank! How it Works!
8:35