HVAC Breaker Tripped?? DON’T Just Reset It!! 

Quality HVACR
Подписаться 104 тыс.
Просмотров 32 тыс.
50% 1

- SUPPORT THE CHANNEL -
www.patreon.co...
- Check out @TruTech Tools, LTD -
www.trutechtoo... (Use promo code “QUALITYHVAC” to save 8%)
- HVAC TACTICAL -
hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%)
- FOLLOW ME -
Instagram: @qualityhvacr
- BUSINESS INQUIRES -
qualityhvacrtn@gmail.com
- TOOLS I USE -
Veto OC140 Case:
vetopropac.com...
Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtoo...
Fieldpiece VP87 Vacuum Pump:
trutechtools.c...
Fieldpiece MR45 Recovery Machine:
trutechtools.c...
Fieldpiece Hose Kit:
trutechtools.c...
Fieldpiece SR47 Refrigerant Scale:
www.trutechtoo...
RLS Refrigerant Press Tool Kit:
www.trutechtoo...
Solderweld Brazing Kit:
trutechtools.c...
Fieldpiece SC480 Meter: www.trutechtoo...
Fieldpiece SC680 Meter: www.trutechtoo...
Fieldpiece SM380V Digital Manifold: www.trutechtoo...
Supco Magnetic Umbrella: www.trutechtoo...
Supco Coolpressor:
trutechtools.c...
Supco Jumper King:
trutechtools.c...
Fieldpiece DR82 Leak Detector:
trutechtools.c...
#hvacrepairs #hvac #compressor

Опубликовано:

 

10 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 68   
@gourmetcookingwithkids3390
@gourmetcookingwithkids3390 11 месяцев назад
A few things to note: 1- always open/close disconnect with your left hand. There’s a reason the lever is on the right side. This way your body isn’t in front of the panel when you energize or de-energize it. I’ve seen them blow and it’s isn’t pretty, especially if you’re standing in front of it. 2- check those compressor terminals and ohm out the windings 3- open up that electrical panel and tighten the wires on the breaker - many times a slightly loose wire will cause heat, tripping the breaker Great videos man, keep up the great work!
@oscarmiranda2000
@oscarmiranda2000 10 месяцев назад
That’s really great advice thanks !
@maness2112
@maness2112 11 месяцев назад
My luck the breaker would trip again at 1 am.
@user-nf8jr2ov8x
@user-nf8jr2ov8x 11 месяцев назад
Lol😂😂😂😂
@actechchris
@actechchris 11 месяцев назад
Me too🤦🏻‍♂️
@AllTattedUp13
@AllTattedUp13 11 месяцев назад
Big facts brother 😂
@topher8634
@topher8634 11 месяцев назад
I would measure for voltage drop across those contacts with it pulled in and loaded up. Anything over 1 volt should be replaced. I usually do if the scale switches from the mV to V scale. That will usually tell you if the contacts are pitted. Won't tell you if the contactor is mechanically sticking or dragging though. A visual inspection is a good idea too. The three pole contactor is the most common reason I find for a tripped breaker. That or a blown fuse in a fused disco. Sometimes the single phasing will overload the breaker and trip it before the IOL shuts the motor down.
@bossJAD_hvacr-plu-ar
@bossJAD_hvacr-plu-ar 11 месяцев назад
Thanks for that info man! That 3-phase compressor doesn't need a run cap. Still attending a class in an HVAC school and they don't mentioned that, or maybe they just forgot.
@JOSHIEWAY
@JOSHIEWAY 9 месяцев назад
I THANK him SO much for being on RU-vid he really HELPING ME OUT IN MY HVAC career I just graduated with MY universal EPA certification
@cjones6776
@cjones6776 11 месяцев назад
Check disconnect with a thermal imager. The contacts may look good, but will heat up and trip the breaker.
@austinespinoza4292
@austinespinoza4292 9 месяцев назад
Thank you so much for the videos you make I’ve learned so much about HVAC from you and it helped me land my first job in the field All I can say is thank you again and we miss your vids
@joshuaespinoza6331
@joshuaespinoza6331 7 месяцев назад
Same here brother. I'm learning alot. Hey, are we related? We have the same last name. 😀
@ScubaCody
@ScubaCody 3 месяца назад
This guy and Word of Advice tv are the two channels I watch 99.9% of the time! Both are amazing techs! Good luck with your journey! Ac Service Tech LLC is also a very good channel to watch too!
@williamfabian8063
@williamfabian8063 11 месяцев назад
In my opinion, been in the business 30 plus years, That is the type of call where I just go ahead an replace the part. Zach definitely seems to be one of the most honest guys I have seen out there , but when you are dealing with the commercial side, the $$ amount is so minor that it shouldn't matter on an item like that. It will take a minimum of 2-3 weeks to get approval. More than likely you will get a call back in that 2-3 weeks, Time is money, and the amount of travel time to the job, then getting up to the roof and accessing the equipment is time!! Just Change it.!!
@philltafolla
@philltafolla 11 месяцев назад
I would have replaced the contactor , cleaned the condenser, and took CFM amp readings 😃🤷🏻‍♂️
@reghardsteynberg3006
@reghardsteynberg3006 11 месяцев назад
Client needs to give approval or you will not get paid for spares. That's why Zak qoute for repairs
@supabiscuit
@supabiscuit 11 месяцев назад
I’ve learned to never assume power is coming in on the top of the disconnect…. Which works till you go to pull a fuse as the bottom end will always be hot
@richardthomas1743
@richardthomas1743 11 месяцев назад
Thumbs UP! Thanks for taking us along.
@zoubiryagoubi1901
@zoubiryagoubi1901 7 месяцев назад
I like the tool box you said we're going to got it bellow on the description but I didn't find it yet
@potentialhvac6074
@potentialhvac6074 11 месяцев назад
I would have pulled the cover off the contactor and checked the contacts.... guess it doesn't matter if they replace it anyways... nice veto bag!
@iiiphase4606
@iiiphase4606 11 месяцев назад
Check compressor terminals. Could have a loose\burnt wire. Takes two seconds. Ps what shoes you rocking? Thinking about switching out of work boots
@rugged1987
@rugged1987 11 месяцев назад
Haha, perfection sticker there shop is 20mins from our shop interesting seeing they service stuff down in TN I live in northern KY btw.
@javierherrera2407
@javierherrera2407 11 месяцев назад
Hello Zach, greetings from Cuba, your videos are very good and instructive.
@robalexander7348
@robalexander7348 11 месяцев назад
Well done Zac, i look forward to the next follow up vid 👍 Au
@zekenzy6486
@zekenzy6486 11 месяцев назад
Great Video. Thank you for sharing. Does 3 phase Condenser fan Motor and Blower fan Motor have Capacitor ?
@Josh-px6xb
@Josh-px6xb 11 месяцев назад
No
@jessepickle
@jessepickle 11 месяцев назад
That's a sweet case with the probes
@FreddyPrieto94
@FreddyPrieto94 7 месяцев назад
since that middle leg was a possibility of not getting good contact that caused the tripped breaker, would doing a voltage drop while unit is running help verify anything?
@vicentepacheco3500
@vicentepacheco3500 11 месяцев назад
Thanks!
@hvaclifeatx7012
@hvaclifeatx7012 11 месяцев назад
Great video 👌
@timothysears6970
@timothysears6970 11 месяцев назад
My new favorite channel!
@kevindavis8117
@kevindavis8117 8 месяцев назад
Haven’t seen any videos in awhile
@PatrickSmith87
@PatrickSmith87 11 месяцев назад
Use some of that YT money and buy some upgraded multimeter leads with some alligator clip attachments
@jwoutdoors1451
@jwoutdoors1451 11 месяцев назад
Making me jealous with the wireless stuff 😅
@AllTattedUp13
@AllTattedUp13 11 месяцев назад
Probes suck homie. Stick with the fieldpiece digital guages. I have a set of fp and yellow jacket probes and they just collect dust man. 😂
@bigdaddy5948
@bigdaddy5948 9 месяцев назад
Makes all that moving around look easy. Wait till he's in his 60s. Lol
@christophera4406
@christophera4406 11 месяцев назад
Loose lugs on breaker
@zoubiryagoubi1901
@zoubiryagoubi1901 7 месяцев назад
Nice job bro like it
@coreybomhoff4784
@coreybomhoff4784 11 месяцев назад
You can remove the contractor faceplate to check for pitted plates
@AllTattedUp13
@AllTattedUp13 11 месяцев назад
I haven't had them or seen them in a few years. But I remember when damn earwig bugs would get in contacts and get smashed when contact closed and they would prevent the power from making lol. Kinda miss them calls, they was easy 😂
@topher8634
@topher8634 10 месяцев назад
@@AllTattedUp13 ants is what I see a lot of the time. The buzzing talks to them I think.
@TheDoghigh
@TheDoghigh 11 месяцев назад
should add the appion charging T to that kit of yours
@kevindavis8117
@kevindavis8117 8 месяцев назад
Where has he been?
@PabloHernandez-bm8kf
@PabloHernandez-bm8kf 11 месяцев назад
while they approve the field of the pieces. Did you do this review? And is there a refund when you do the repair?
@JesseDoesHVAC
@JesseDoesHVAC 11 месяцев назад
Zach have you considered a chest mounted gopro or something similar?
@alejandrorodriguez9336
@alejandrorodriguez9336 10 месяцев назад
Are you going to be giving away those 3 veto bags that you mentioned in one of your shorts, if so, how can I enter the giveaway.
@metzemog9181
@metzemog9181 4 месяца назад
What hive is that?
@dannygonzalez5844
@dannygonzalez5844 3 месяца назад
Who need approval to remplace a part in Miami ?? ...lol ..the owner right away , is so god dam hot in here and i need that ac running ...me ok well sir that gonna cost you $2k you've the magnetic contact and the compressor both dead , the owner wait what ?? Whit that money i can buy a new system,.. Me not sir a new unit like this go to cost you at least 6k ..the owner ohh man i love how this hot feel right now 😂😂😂
@jeremialfoso5859
@jeremialfoso5859 10 месяцев назад
Hello friend, I have a question, if you could help me please, my question is the following: I have a two-story house, each floor is 1000 square feet and the height of each floor is 18 feet. My question: How can I calculate how many frigorias I need for my house? My question. The thing is that many air conditioning brands only give calculations for ceiling heights of 9 feet and they say that if they are more feet high the calculation is different but they don't say how I've been trying to find an answer for weeks and there isn't one and I would like an air packge unit for the whole house, my question in summary would be how should I calculate the frigories of my house by the height of my house which is too high
@caru3257
@caru3257 10 месяцев назад
Manual D gives you the formula to calculate the cooling load.
@josemartinez-4570
@josemartinez-4570 10 месяцев назад
What size is your inclosed trailer?
@thepoopsoup
@thepoopsoup 11 месяцев назад
20 amp pretty low for that unit?
@jaytee0516
@jaytee0516 11 месяцев назад
What’s the brand/style of your work pants?
@jaytee0516
@jaytee0516 11 месяцев назад
^^
@meirleibovich1305
@meirleibovich1305 11 месяцев назад
shoes you use?
@quintinmullen4266
@quintinmullen4266 11 месяцев назад
What brand was that little black pouch
@ApartmentMaintenance
@ApartmentMaintenance 11 месяцев назад
Veto
@muniznick
@muniznick 11 месяцев назад
Did I see a non Veto tool pouch on your belt.
@GurukirpaAircool
@GurukirpaAircool 10 месяцев назад
Sir I like with you join Air condition life injoy
@maysramohmmedali7506
@maysramohmmedali7506 10 месяцев назад
I want to communicate with you
@paulrozinski1488
@paulrozinski1488 11 месяцев назад
You’d be surprised how quick you get approval when you leave the system off. Tell them that you suspect that the contractor is bad and you don’t feel comfortable leaving the system on in that condition. WHY should you have to wait, chase down the right person, then drive back there again to replace a simple part. This is not being a prick, it’s being a realist. Your time and effort are valuable, others ( who are willing to pay ) are waiting. You’re not at their beck and call !!!!
@richardthomas1743
@richardthomas1743 11 месяцев назад
👎@paulrozinski1488 ,
@ttaylor6185
@ttaylor6185 11 месяцев назад
That's called being a liar.
@bossJAD_hvacr-plu-ar
@bossJAD_hvacr-plu-ar 11 месяцев назад
If you follow him for a long time, you will notice that he is not that kind of person. He value honesty and quality work in his customers.
@13raxx67
@13raxx67 11 месяцев назад
I hope you're never put in a position of power.
@paulrozinski1488
@paulrozinski1488 11 месяцев назад
@@ttaylor6185 no it’s not, he said it himself…. that’s contractor doesn’t look good . He’s acting under an abundance of caution
@jhatfield2755
@jhatfield2755 8 месяцев назад
Compressor sound like poop
Далее
Horrible HVAC Design & How I FIXED it!!
21:10
Просмотров 38 тыс.
아이스크림으로 진짜 친구 구별하는법
00:17
This One CONFUSED Me…
15:25
Просмотров 50 тыс.
American Standard replaced Carrier .. MUST WATCH !!
12:47
Failed Compressors - Don't JUST REPLACE IT
24:59
Просмотров 61 тыс.
DON’T Assume Anything…HVAC Repairs
15:55
Просмотров 35 тыс.
Commercial or Residential HVAC | Which Do I Prefer??
21:43
Commercial HVAC Preventative Maintenance
16:34
Просмотров 25 тыс.
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59