Тёмный

HVAC Chiller Approach Explained 

HVACTIME
Подписаться 43 тыс.
Просмотров 46 тыс.
50% 1

This hvac training videos goal is to teach hvac technician on how chiller approach works and what to do with it. I give an indepth look at condenser approach and evaporator approach. This online chiller training is great for entry level chiller tech looking to expand their knowledge. This applies to water cooled chiller and air cooled chiller. This can also help with centrifugal chiller surge. Chiller surging is commonly a heat exchanger issue.
Also check out these great training channels
‪@HVACKnowItAll‬
‪@acservicetechchannel‬
Check out Merch Store! my-store-b413f9.creator-sprin...
You can contact me at Hvactimetx@gmail.com
Support the channel through, venmo.com/code?user_id=316085...
Zelle @ Hvactimetx@gmail.com
#chiller #hvac #hvactrainingvideos #hvactechnician #chillertech #chillerapproach

Опубликовано:

 

14 июл 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 72   
@HVACTIME
@HVACTIME Месяц назад
Level up your chiller career! HVACTIME Chiller Academy offers interactive courses, that can go in the field with you to learn, designed by chiller veteran to guide you through complex chiller systems. Learn at your own pace and gain the expertise to thrive. Limited-time Early Bird Discount available! chilleracademy.com
@PTF491
@PTF491 3 года назад
Best commercial hvac channel on youtube
@HVACTIME
@HVACTIME 3 года назад
Thank you
@davidwilliams729
@davidwilliams729 Месяц назад
Thank you for helping me understand chillers.
@andrewedis9907
@andrewedis9907 2 года назад
Im from the UK and I don't see thses very often so thankyou for the video.
@buildingstatux7720
@buildingstatux7720 3 года назад
Best chiller channel ever
@HVACTIME
@HVACTIME 3 года назад
Thank you
@rupertstaana3382
@rupertstaana3382 3 года назад
Great video once again!
@nathandaubis819
@nathandaubis819 2 года назад
A SOLID MOMENT IN HISTORY KEEP UP THE GOOD WORK.
@LatinTurkNYC
@LatinTurkNYC 2 года назад
Excellent info! Great video! Thank you!
@sbitschy
@sbitschy 2 года назад
Great video and commentary on the reasons we pay attention to approach. Particularly found useful your commentary on adjusting water flow rates and the impacts of these adjustments
@MrEric100000000
@MrEric100000000 2 года назад
Fantastic explanation as usual. Keep up the great work!
@HVACChillin
@HVACChillin 3 года назад
Great video as always
@jackbauer4612
@jackbauer4612 2 года назад
Great explanation.
@kevinthomas3539
@kevinthomas3539 2 года назад
Another great great video
@hkhsm359
@hkhsm359 3 года назад
Nice video. Great knowledge. Thanks for sharing
@dodgerblue182able
@dodgerblue182able 2 года назад
Excellent description of approach. When I was an apprentice, a journeyman tried to tell me the delta T between incoming and leaving water was the approach. I spent a couple years believing that, lol!
@kasimshaikh3750
@kasimshaikh3750 Год назад
That happens a lot more than it should.
@MR-backup
@MR-backup 7 месяцев назад
I am having Chief, Assistant Chief's, and Leads tell me it's called "being inverted".
@jeffreykubiak5126
@jeffreykubiak5126 Год назад
Great video,thanks 👍
@MegaDee911
@MegaDee911 2 года назад
Very good information.
@nickyengle9668
@nickyengle9668 2 года назад
Liking your videos btw,wish we had this 30 yrs ago.
@saliyamadushanka2887
@saliyamadushanka2887 Год назад
Best explain .❤
@salehabdullah399
@salehabdullah399 4 месяца назад
Really good explanation
@Astrojamus
@Astrojamus 2 месяца назад
can i just say thank you I just got the building engineer position and I came from hvac background and I have enough knowledge to be able to get by but I never got to diagnosing the big boy stuff. I hate when I look up explanations and its a video of a tonka truck dropping off and picking up hot/cold water its like dude i want to know exactly what's going on in that tank so i can understand!!!
@nakiapringley5391
@nakiapringley5391 2 года назад
Great video 💯💯💯💯💯💯
@joshstevens9826
@joshstevens9826 2 года назад
I really like that u r trying to get young guys interested in large tonnage machines. Im the youngest chiller mechanic that we have and im 40. Our vets are retiring this year
@arc3075
@arc3075 2 года назад
It takes several years of hands on experience to effectively PM a LTC. As for service and troubleshooting that will require even longer period under the watchful eye a qualified technician.
@mahendrachoudhari9598
@mahendrachoudhari9598 Год назад
so gret learning chillers fanda thank s sir
@mhtvsarra5775
@mhtvsarra5775 2 года назад
Nice explanation sir
@raghus2395
@raghus2395 2 года назад
Good content brother 🤠
@HVACTIME
@HVACTIME 2 года назад
Thank you
@chrisroday7128
@chrisroday7128 Год назад
Mmmm sweet knowledge
@AKK105
@AKK105 25 дней назад
A very informative and detailed video. Can you recommend a textbook for chiller maintenance and repairing? Thanks
@genegonzalez4713
@genegonzalez4713 2 года назад
. The closer these temperatures are to each other, the more efficient the heat transfer.
@genegonzalez4713
@genegonzalez4713 2 года назад
I think I was referring to the Approach temperature
@genegonzalez4713
@genegonzalez4713 2 года назад
One of the tools a chiller plant engineer or operator should always have is a ( PT CHART) pressure and temperature chart. Another tool needed is the pressure drop chart needed to determine flow rate on each chiller barrel. Now a days they have a ultrasonic flow meters on your bldg automated system
@genegonzalez4713
@genegonzalez4713 2 года назад
Approach also tells us how efficient the heat exchanger transfers heat. If the tubes in the water cooled condenser are dirty your approach temperatures will go up and vice versa. Punching the tubes is a good idea, and keeping tower water clean and filtered
@jweschler
@jweschler Год назад
Very good video. I’d like to add that the reason the approach goes up when the water flow is too low is because the water will go into laminar flow (as opposed to turbulent flow). Laminar flow is when the flow is so low that the water flows down the center of the tubes and is stationary on the tube edge where the heat transfer is taking place. Think of a small stream with very low flow. You’ll see the water and leaves flowing down the center and the water is stagnant on the sides. Turbulent flow has all the water mixing up going through the tubes. In a chiller, when you approach laminar flow, you loose you’re approach very quickly.
@HVACTIME
@HVACTIME Год назад
I agree, this has been a very challenging topic of discussion on this channel overtime.
@MR-backup
@MR-backup 7 месяцев назад
You mean for a Flooded Type Condenser Barrel, right?
@toyinorodare4072
@toyinorodare4072 2 года назад
Thank you for this video. Please do mention the unit of Temperature you are working with either °F or °C
@HVACTIME
@HVACTIME 2 года назад
Good point, I was using °F
@alpena2835
@alpena2835 6 месяцев назад
Can you list acceptable ranges for each type of approach in fahrenheit please? Condenser approach Evaporator approach Cooling tower approach Thank you 🙏🏼
@pridemechanical815
@pridemechanical815 2 года назад
Can you recommend any good chiller classes given by manufacturers to help us build a chillers division?
@dhanagopals2973
@dhanagopals2973 9 месяцев назад
Need more details wanted
@vrejbaghoomian7765
@vrejbaghoomian7765 23 дня назад
Hi , I have 3 "Carrier 5H80" compressors in tandem configuration , besides the oil equalizers on hand hole lower connection , there is also piping on the same hand hole on upper hole which are connected to all 3 compressors , do you know what is it for ?
@politiciansthrowstones
@politiciansthrowstones Год назад
Is that bottom on the hybrid the subcooler? Is there a subcooler on the flooded barrel?
@mwdub02
@mwdub02 2 года назад
What’s the best approach value on a 80 ton CGAM for the evap EX? I was running 7 degrees the other day. Just getting into chillers recently and your videos have inspired me to take this path.
@HVACTIME
@HVACTIME 2 года назад
A typical range is between 3F to 10F
@joshstevens9826
@joshstevens9826 2 года назад
I know 0° approach is ideal. But that also depends on the design. Some chillers are designed for a 2° approach. So if u r running 0° you r running the chiller outside of the design of the chiller.
@brad8665
@brad8665 2 года назад
Trane centrifugal is 2°
@TheMinecraftACMan
@TheMinecraftACMan Год назад
You briefly mentioned WSHP with co-ax coils. Just curious what information can be gleaned from condenser approach on those systems? My first thought would be that a higher approach would mean that coil was likely starting to get fouled, what would you consider a normal approach on such a system?
@HVACTIME
@HVACTIME Год назад
The approach will be higher, typically around 10F
@genegonzalez4713
@genegonzalez4713 2 года назад
Approach temperature? In essence the Chiller approach is the temperature difference between the water and the refrigerant.
@genegonzalez4713
@genegonzalez4713 2 года назад
When you talk about Approach as far as a chiller system you should be very specific because each component has his approach there are Different types of Approach: 1. Condenser Approach Temperature 2. Evaporator Approach temperature 3. Cooling tower Approach 4. AHU Approach Temperature
@HVACTIME
@HVACTIME 2 года назад
I specified chiller approach
@arifminhaj6521
@arifminhaj6521 2 года назад
What the causes if the approach temp of evaporator is negative sensors are New
@HVACTIME
@HVACTIME 2 года назад
What machine is this on?
@localchumb
@localchumb Год назад
I have a question, is the chiller the condenser? I'm asking because my teacher was calling it an evaporator but he may have misspoken and I don't want the wrong idea in my head :(
@HVACTIME
@HVACTIME Год назад
A chiller will have an evaporator and a condenser. The condenser can be water cooled or air cooled
@derrickgarcia303
@derrickgarcia303 Год назад
Are you familiar with Smart air cooled chiller?
@HVACTIME
@HVACTIME Год назад
I am their water cooled but not air cooled.
@MyBallzGotShocked
@MyBallzGotShocked 2 года назад
I notice these are large scale water medium devices. Would these designs be viable in residential scenarios?
@HVACTIME
@HVACTIME 2 года назад
No, wouldn't be efficient enough. And requires more advanced service ability and cost. Some of the original residential system used chilled water but the industry quickly moved away from it.
@achempel46
@achempel46 Год назад
In residential it's more important to look at superheat, subcool, delta t, and static pressures. I have the measure quick app for ease of getting all these in one place and reporting that information at the end of the job. It will throw you off if you look at condenser approach often it's negative which is a sign of liquid line restriction but there's no measurable difference from the condenser outlet and entering the expansion valve.
@MR-backup
@MR-backup 7 месяцев назад
@@HVACTIME " Some of the original residential system used chilled water but the industry quickly moved away from it. " - And now green measures are making residential go back to it 😆😆😆😆
@enternaty
@enternaty 2 года назад
Hello Buddy, we appreciate your clips on the Centrifugal Chillers; Do you have any clips on adjusting the metering valve on the MqQuay / Daikin Centrifugal Chillers. As it seem though you adjust the pilot valve, the main valve, seems to be very lazy in responding, any advice?
@enternaty
@enternaty 2 года назад
I have a 500/ton McQuay Centrifugal Chiller @ 4160 Volts, where the Discharge Superheat is suppose to be 15-18 *F with the liquid injection off @ 100% however, im just getting carryover which is preventing the oil from returning to the Oil sump to maintain the Oil level required. Discharge superheat is falling to 1*F
@jacobmintz3399
@jacobmintz3399 3 месяца назад
Deez
@genegonzalez4713
@genegonzalez4713 2 года назад
Try to be more accurate direct and concise about your chiller tutorials, when you use lot of rhetoric it sounds a though you don't know what you're talking about
@saoodkhan_sorry
@saoodkhan_sorry 2 года назад
U was speaking like u was asleep. So 👎. I m sorry but its real.
Далее
HVAC Tech School: Understanding Chiller Surge
10:08
Просмотров 305 тыс.
HVAC Chiller Refrigerant Recovery Procedure
8:32
Просмотров 20 тыс.
🔧Chillers - Condensers
15:07
Просмотров 215 тыс.
Chiller Surging During Centrifugal Chiller PM
14:19
Просмотров 20 тыс.
What is VGD in Centrifugal Compressor
8:58
Просмотров 1,3 тыс.
Air Cooled Chiller Recovery
7:55
Просмотров 716
Why does Discharge Superheat Matter?
12:27
Просмотров 2,6 тыс.