I think i mess this board up? - Electrician 

N Bundy Electrical
Подписаться 108 тыс.
Просмотров 37 тыс.
50% 1

If we can get this video up to 2000 likes I’ll start the Unilite giveaway
Back johns job and I’m not to happy with the result,
I think I messed this board up
Use code BUNDY25 at unilite.co.uk/product-categor... for 25% off
Use code BUNDY10 at www.expertelectrical.co.uk for 10% discount
Join this channel to get access to perks:
/ @nbundyelectrical
This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.

Опубликовано:

 

9 июн 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 163   
@nickbuckle646
@nickbuckle646 2 года назад
Hello Nick. I recommend when doing SWA cable to strip the double insulated layer once you have the cable in the D.B, score it first, but with bigger sizes you run the risk of ripping the cores insulation on the gland as you pull the cores through.
@effervescence5664
@effervescence5664 2 года назад
Very nice board and extremely functional. There's two types of commercial/industrial, one where it's fit and forget and that's the fit out forever, the second is where they're constantly changing layouts. You've dressed the cable nicely for the latter and honestly that's preferable for most of the places we work.
@ryandraper8525
@ryandraper8525 2 года назад
Looks very pretty, but by cutting the cpc to fit at the top now make those circuits potentially not future proof. There is plenty of room in the enclosure to run all conductors to the the base and back up again, terminating as you have done. This way any adjustments or future board changes are not restricted by the length of the cables left by the previous installer. Also, the swa's are spaced too far apart making future additions untidy. I agree with the comment regarding the use of a box trunking and a slot or large bushes.
@bikerchrisukk
@bikerchrisukk 2 года назад
you can just imagine the spark many years from now going back for a wiring fault, they open up the cover expecting a birds nest of cables and see your work and thinking ahhh thank god. Tidier than most I see mate 👏
@stefanovanenio
@stefanovanenio 2 года назад
yeah, as some of the other guys have said, id have put 2 rows of 3 on one side as there could be another 6 or even 18 armoured cables going in depending on phase. assuming that i woud have most likley used some metal trunking accross the top of the board and down either side (the sides for aesthetics) to give myself another 200mm across the top of the board. otherwise, internally very neat.
@peterstephenmahon7632
@peterstephenmahon7632 2 года назад
probably would have put a big lump of metal trunking on top and jig sawed out a nice space on the of the board just for space, that said it's not a full on old school industrial environment, where equipment could be changed on a monthly basis, it's lovely and neat but you have restricted it a bit, maybe split either side of the termination at the top and connections from the bottom up, in the board leaving the room for expansion, cheers for your output 👍 top guys
@DazEssex
@DazEssex 2 года назад
Smart good boards to work with. I’d Normally run length 4x4 or 6x6 galv trunk over the top and maybe down one side paxolin through to the Db future proof it a little.
@austenpsmith
@austenpsmith 2 года назад
Great work as always and thanks for the insights
@karlhowells3822
@karlhowells3822 2 года назад
I use thease boards a lot they are great we use finger trunking in the Db which looks very neat and clean. I would also use banjo rather than earthing nuts. But tidy
@brianwood5220
@brianwood5220 2 года назад
Looking great Nick. Tidy board too. Thanks for sharing.
@tommymack3210
@tommymack3210 2 года назад
That board looks neat. I feel like commercial/industrial is more relaxed, chill, get to have fun and banter/bond with the colleagues. Where as residential is more stress because this 1 customer is paying for your time. Also I see that in commercial people like to wire things with more loops and larger bends. Which actually makes sense, because in commercial you have a lot of that same work to do. If you were to bend all those wires in perfect 90 degrees, it would take much more time. Also the next sparky to come in wont necessarily be so precise and throw it in, then it just looks crap😬. But almost every electrician can leave things in a slack bend
@user-fn4kl4ft8r
@user-fn4kl4ft8r 2 года назад
Would definitely of slotted the board and put trunking on with paxolin, as it looks difficult now to add more circuits neat in the future.
@GeoB24
@GeoB24 2 года назад
Lovely work mate only question would be did u put bootlace ferrules or pin crimps on them cables ?
@ccgymer
@ccgymer 2 года назад
Never thought about putting the cpcs in the bottom, I've always come from the top, I can see why you've done it though to keep them clear of any future SWA'S going into the top of the board. but I put metal trunking on the top and either pax or 4x 50mm bush and lockrings so I don't have to worry about other SWA'S coming into the top of the board lid and catching the cpcs.
@harryryan6661
@harryryan6661 2 года назад
I do the same mate especially with these Schneider boards, only problem I find with them is looming the earths having a 100x100 trunking above works a treat
@chaseohara4781
@chaseohara4781 Год назад
Click on neutral and that board footprint is pretty common in residential in North America now. It's always interesting to see the different standards.
@cumberland1234
@cumberland1234 2 года назад
Looks good, personally I’d run an earth cable from the bolt which is connected to the SWA up to the earth rail, I don’t know what the MI states on this but it’s belt and braces.
@onewheelnut
@onewheelnut 2 года назад
Great looking work topnotch, one thing I'd change, put isolators next to board or board next to isolators, half the time taken.
@unorthodox_kid7029
@unorthodox_kid7029 2 года назад
Funny because I’m doing this on a job in Canary Wharf at the minute had framework for about 8 risers to do and had 4 giant panels mounted for lighting and power 🤣 board looks neat but I’d of slotted the top of the DB used paxalin and fixed a header trunking on top that way you’ve got plenty of space to gland into the top. Frameworks ok but im picky and like them cut to length not over hanging and it needs end caps.
@RichardArblaster
@RichardArblaster 2 года назад
Great job. I've been up in one of those VNA trucks before, very nervous as I'm not very good with heights. 😆😆😆
@garryrandall6972
@garryrandall6972 2 года назад
Looking very neat there Nick.
@garethwatson7999
@garethwatson7999 2 года назад
I see Unilite in the UK becoming similar to Toughbuilt in the States, I really rate both their stuff.
@shuaibmohammed4749
@shuaibmohammed4749 2 года назад
Well done board looks good picked up some good tip from you
@ianbird6997
@ianbird6997 2 года назад
Looks prefect mate top work👍
@ronanotoole1973
@ronanotoole1973 Год назад
Artisan Electrics wouldn't get a look in :D Great work as always.
@fraserreid719
@fraserreid719 2 года назад
Header trunking or righting bunching of armours. 50% capacity of that board remaining for future use so need to think of the future work
@kingcobrauk
@kingcobrauk 2 года назад
Perhaps we have been doing ware house work wrong all these years but we use that really large trunkings that you used to fix your tray too for holding all our cables as they run all around and at multi levels just used tray to get up or down between. So are we the only ones doing this? You didn't say but I hope you are fitting metal straps on the tray once all the cables are installed?
@Alchemetica
@Alchemetica 2 года назад
SO. Adam is out and Stacey is in? Adam, that's the risk you face when you take days off 🤣🤣🤣🤣🤣 An interesting video where we get to see some of the wiring and layout of a warehouse. The forklift in floor guidance wire is a brilliant safety and time saving system. To have how it functions explained is a first for me.
@arrondaly2219
@arrondaly2219 2 года назад
Lovely work Bro 🤟🏼
@afghansun
@afghansun 2 года назад
Nice and neat job as always
@impactvision
@impactvision 2 года назад
I presume this industrial unit is near Avonmouth/Severn beach? That noise you can hear is the Severnside Sirens.
@ForTheBirbs
@ForTheBirbs 2 года назад
What an awesome system with that forklift!
@sparky1543
@sparky1543 2 года назад
Use these boards on every job we do. Neat but next time, 6x6” trunking header on the top, jigged out, paxoline in between, earths go in the top not the bottom. Great boards to use, they also do a rcbo without flying leads. U
@cheeseburgerbeefcake
@cheeseburgerbeefcake 2 года назад
From the uneducated perspective, looks like a nice board, it has cables and doesn't look like a huge mess of pretty coloured spaghetti! As someone else mentioned, these kinds of install are set and forget (apart from testing), when it's offices or education space, the change is neigh on constant so the real trick there is maintaining a nice looking install!
@dennisw5058
@dennisw5058 2 года назад
Looks neat, I would of had two rows on left-hand side, giving room for future cables on right-hand side. So you not got crossing over each other
@garethwatson7999
@garethwatson7999 2 года назад
We normally hang those FLT chargers off the Uni strut with a couple of Zebadies, better to keep them off the floor or the muppets always drive their FLT forks into them when the pull up to charge it.
@garyhowson9068
@garyhowson9068 2 года назад
Really fancy trying one of these unilites
@jasonbowe9767
@jasonbowe9767 2 года назад
That board is very well done 👍🏻
@three-phase562
@three-phase562 2 года назад
Top job on the install fella, but what is this Artisan think you keep mentioning!?!
@davidclarke2513
@davidclarke2513 5 месяцев назад
As a recently retired Industrial sparks of some 50 years I would have destroyed you if you had left those armoured cables as you first terminated them but as you altered the radius of the bends I would say that your connections were fine.if you want to see good distribution board connecting take a visit to the Norwich & Norfolk Hospital where I connected a fair few of them
@Cardetailingburnley
@Cardetailingburnley 2 года назад
Nick it looks very good
@autoSRI
@autoSRI 2 года назад
Looking pretty tidy inside the only real criticism I’d have it you shouldn’t have spaced the cables out like that they should have come in closer or on one side as you have essentially made it impossible for the next person to make it look tidy when they use the rest of the board as there is no tidy places to put glands
@tommymack3210
@tommymack3210 2 года назад
Agreed, could have put the cables closer
@greggsmith4539
@greggsmith4539 2 года назад
I always put metal trunking top and bottom that way plenty of space for more armoured’s and stops having to drill into a live board
@davidcullen2130
@davidcullen2130 2 года назад
Wow bro like always amazing job looks amazing nice neat tidy really good and funny content. Poor Adam and his mum hahahahah 🤣 Adam's mum what. 😭🤣🤣. I seen that trick for armoured cables use ratchet tie straps to hold it into place and it will stay where its been put to make it nice and neat and straight. I know normally it's used on bigger armoured cables.
@PhilipWillsWorld
@PhilipWillsWorld 2 года назад
Great give away, thanks.
@tangoengineering
@tangoengineering 2 года назад
Bootlace crimps are for clexible cable pin crimps should be used on 6491x type stranded cable
@keithjackett9895
@keithjackett9895 Год назад
You should have cut All the cables Long enough to reach the furthest Breaker and then Dress the slack back on itself. same for Neutrals an Earth cables, also there is no need for boot lace Ferrals on Solid cable- they for stranded cable only.
@s3an175
@s3an175 2 года назад
No header on a board that size and using the whole plate on the top for a few cables? Future proofing would be to overrun a header across the top to cover the total size of the board which would then allow you to lose the slack in side the trunking and keep the board simple inside. Like the piranha nuts, better than banjo’s and give you more space to bring the glands closer together.
@haydenuk02
@haydenuk02 2 года назад
Great work and thanks for sharing this with us take care
@cyrillynch907
@cyrillynch907 2 года назад
Great one
@jamieblatantsparky
@jamieblatantsparky 2 года назад
If a contractor took up the whole top of the board like that on one of my jobs I would make them replace it , 50% of the board circuits is taking up by 100% of the top , none and neat inside and a good job , but allways thing of the next guy
@dangranet7621
@dangranet7621 2 года назад
Would have to disagree ! Not here for anyone else , I’m thinking of my responsibility and reputation not others - and how difficult or easy I like the job to play out ! If the next guy is in a tough spot because of my good work unfortunately that is tough! He’s not paying for my time the customer is.
@jamieblatantsparky
@jamieblatantsparky 2 года назад
@@dangranet7621 bet your works total dogshit with that kind of attitude, considering maintenance and additions to work is part of the regulations
@sparky1543
@sparky1543 2 года назад
@@dangranet7621 🤦🏼‍♂️ you wouldn’t last long on a site then with bad moves like that.
@paulharrison6408
@paulharrison6408 2 года назад
Agree. Idiotic spacing of cables.
@robertburrows6612
@robertburrows6612 2 года назад
Ferals on breakers , something I wouldn't do unless the manufacturer instructions state you should use them
@Timetochange76
@Timetochange76 2 года назад
I agree. A bit time consuming and unnecessary. As long as the conductors are suitability terminated then it's satisfactory. DB is very neat though, great job. 👍
@TheMattSturgeon
@TheMattSturgeon 2 года назад
Agree it isn't strictly necessary. Often ferrels aren't "manufacturer approved" for stranded cable either... But they will make the termination last longer if the cable is going to be re-inserted several times in its lifespan (e.g. EICRs). Sometimes it's the little (unnecessary) touches that separate a good job from a top quality job 😉 ...Not saying I'd bother though, in most cases 😂
@landroverlandyman
@landroverlandyman 2 года назад
Looking pretty good to me. 👍
@dennisreid3866
@dennisreid3866 2 года назад
Dennis Reid Have you seen the new Armeg cross head driver?
@lh2589
@lh2589 2 года назад
I'd say Adams had long enough to comment now mate. Have words!!!
@colin125gwr
@colin125gwr 2 года назад
that forklift is wicked
@dimitar4y
@dimitar4y 2 года назад
that forklift is kinda dope.
@datsunruss
@datsunruss 2 года назад
Looks good to me Nick.👍
@iScoTT29
@iScoTT29 2 года назад
Schindler boards earth bar location is terrible imo. No where to leave enough slack on cpc’s much prefer the Eaton range.
@paulharrison6408
@paulharrison6408 2 года назад
Eaton superior design imo certainly I terms of the casing as you have a removable top and bottom plate for access. Scneider casing is dogshite in comparison. Schneider dB inside however I prefer the earth at the top gives more room down the side of the breakers as its only live and neutral so gives 33% more room! Eaton casing with schneider internals would be the perfect commercial DB imo.
@ionutth4895
@ionutth4895 Год назад
Id love working like that :)
@TheHomeent
@TheHomeent 2 года назад
Can't believe you left that first cable dressed like that, where is your pride. Mt ocd couldn't leave those dressed like a row of condemned houses. You needed to get the bends made so the cables sat straight before stripping for the gland. Adam wouldn't have made that mistake. Lol
@tysondundas1947
@tysondundas1947 2 года назад
Don't tie rap in the DB. Heat grouping & poor for fault finding/ testing. I'd leave some slack but that's how I was trained.
@Chunkymunky84
@Chunkymunky84 2 года назад
That glanding is brutal mate they are all pissed 😆 your eyes painted on son lol u wouldn't get away with that in ireland.
@jurassicsparks5220
@jurassicsparks5220 2 года назад
It’s not the only thing that’s “pissed” though. I’d say 98% of irelands population is.
@iotelectrical
@iotelectrical 2 года назад
Looks smart pal
@kevinwilliams1203
@kevinwilliams1203 2 года назад
Unilite stuff yes yes yes please nick 😉👍😄
@garywateridge
@garywateridge 2 года назад
nice job
@briwire138
@briwire138 2 года назад
Looks a good job to me.
@rhysboni6329
@rhysboni6329 2 года назад
Don't use ferrules on SWA, pin crimps if required. Ferrules only for tri rated
@scottsparky1
@scottsparky1 2 года назад
Cpcs are in the wrong terminal and wrong side
@Shane23373
@Shane23373 2 года назад
Them knifes good class tryed buying 1 there and it’s €24 postage 😞😞😞😞
@persona250
@persona250 2 года назад
That cable does not require a ferrule .
@dretrodealerakasparkz5406
@dretrodealerakasparkz5406 2 года назад
“Eye it up” theres the domestic side coming out 😜
@ChickenWizy
@ChickenWizy 2 года назад
goood stuff boyos
@dodegkr
@dodegkr 2 года назад
earths and input swa angles, residualcurrent for commercial, savery for to spec, artisan for wallet empty, bundy for domestic cja for across the board
@DaleMarriott1337
@DaleMarriott1337 2 года назад
jokari ;) Just wondering how them live connections are live without the slider across
@NBundyElectrical
@NBundyElectrical 2 года назад
they weren't mate, didn't realise about the sliders til after trying to test
@DaleMarriott1337
@DaleMarriott1337 2 года назад
@@NBundyElectrical Yellow thing on top of board is for moving them over ;) different world I guess to you I'm having same issue doing domestic mainly cable routes I find a nightmare.
@intercity125
@intercity125 2 года назад
Are the conductors now suitably rated for the circuit after the bundling derating factor is taken into account for that many tied together? Only big question with using ties to make it neat...
@AndyK.1
@AndyK.1 2 года назад
I thought he said he was going to remove the cable ties
@deanmoore8245
@deanmoore8245 2 года назад
Earthing Nuts are a waste of terminals right there. Just gutter bolt them to the steel board.
@paulharrison6408
@paulharrison6408 2 года назад
100% no need as got separate earth core!!
@neilmccartney9987
@neilmccartney9987 2 года назад
Great job and video. From a plumbers view anyway 😜
@HeathenGeek
@HeathenGeek 2 года назад
Did they not give you a 5 metre tape measure? 😥😥😥
@AndyK.1
@AndyK.1 2 года назад
Can’t hear Stacy. Or is she on the other channel ?
@Evansallelectrical
@Evansallelectrical 2 года назад
Where is Mike (Residual Current) ?
@nw5835
@nw5835 2 года назад
Friday night - down the pub.
@craigmorrison2459
@craigmorrison2459 2 года назад
I can’t understand why you’d fit a dab like that and not put trunking along the top to gland into, it would be easier for you and for the next person to gland into .
@stevejacklin8462
@stevejacklin8462 2 года назад
Not a proper industrial Spark. No Cable or core numbers, and didnt take 2 weeks to install.
@alanbeard4871
@alanbeard4871 2 года назад
Hi Nick I didn't think we were meant to use ferrules on stranded wire, just on multi stranded. Because the stranded wire doesn't distort enough to guarantee a good connection.
@tonyblair3779
@tonyblair3779 2 года назад
Should only use on flex
@RobertLow18
@RobertLow18 2 года назад
Looks good, might need to invest in that knipex stripper you used to strip sheath off SWA core. Don’t think you’re meant to put ferrules on that type of cable btw!
@dimitar4y
@dimitar4y 2 года назад
ferrules just help with keeping all the strands together so you can insert easier + some strain relief.
@RobertLow18
@RobertLow18 2 года назад
@@dimitar4y hi yes I know what ferrules are used for, I use them myself. I only meant that they should not be used on this type of stranded core cable
@dimitar4y
@dimitar4y 2 года назад
@@RobertLow18 doesn't matter since the conductors will be crushed by the terminals. Again, it's to keep the few strands together. when you flex the cable there's a good chance they'll go out of alignment and piss you off.
@RobertLow18
@RobertLow18 2 года назад
@@dimitar4y yes I know it’s to keep the strands together, I am an electrician and use ferrules regularly. But they shouldn’t be used on this type of cable
@TheMattSturgeon
@TheMattSturgeon 2 года назад
efixx did a really good video going into the nuances of what cable classes you can/should use ferrels on. Basically, most ferrels are type tested on flex (class 3), a few are type tested on stranded (class 2). It comes down to manufacturers instructions and engineering judgement. Ferrels are pretty much required for flex in screw terminals, because there's a good chance of the screw damaging the flex strands. But there's no hard and fast rules on stranded. Some argue that they don't do any harm if the terminal will "crush" the cable anyway, since it's effectively "extra" crimping. The counter argument is that (depending on crimp brand), they may not be type tested for stranded cables. But BS7671 only tells us to _consider_ manufacturers instructions, not to follow them as gospel. We are entitled to use our engineering judgement. Whilst ferrels aren't required on stranded conductors, they do still do a good job of holding all the strands together. Often you see strands spreading out (e.g. as cables are dressed into a box), causing the connection to loosen. This is less likely when ferrels are used. So there is some benefit, even if it's not the main intended use of the crimps. I wouldn't recommend using crimps that aren't type tested against the cable class your using unless you are going to further compress/crush the connection... E.g. with a screw terminal or cage clamp.
@007floppyboy
@007floppyboy 2 года назад
I hope you de-rated all the MCBs to allow for that grouping in the DB, group of six in an unventilated enclosure, is not the same as swa's on perforated rack.
@Woodkin007
@Woodkin007 2 года назад
Did Nick used to be a plumber?...not the most considerste placement of swa cables
@RichardArblaster
@RichardArblaster 2 года назад
Is Stacy an apprentice?
@MrEvoSham
@MrEvoSham 2 года назад
Definitely a Whitney. It's not right but it's okay.
@gordonmackenzie4512
@gordonmackenzie4512 2 года назад
Unilite bundle.
@mickbroadbent6750
@mickbroadbent6750 2 года назад
it looked ok to me
@chayjones9624
@chayjones9624 2 года назад
When’s the next van video coming?
@AndyK.1
@AndyK.1 2 года назад
I’m amazed how many ppl want to see a 10 year old van ? 😂
@sunshine3187
@sunshine3187 2 года назад
Did you self Tap the tray to the perlin? Good God man 😂
@ccgymer
@ccgymer 2 года назад
🤣
@johng.1703
@johng.1703 2 года назад
there is no I in team... but there is a me.
@notoriousclothingonline6071
Im in! Love @unilite stuff
@chanellistrik
@chanellistrik 2 года назад
terlihat bagus ko
@SteveNail
@SteveNail 2 года назад
And the link to Johns RU-vid page and Staceys Instagram is? 😂
@calmeilles
@calmeilles 2 года назад
Missing. 😀
@paulharrison6408
@paulharrison6408 2 года назад
No need to put flyleads on as swa has cable has an earth core. Db casing is earthed so what's the point as armour is earthed through that. Deffo should have used trunking on top to allow future cables. If not then at least put cables closer! Very selfish and no rhought for others lol!
@artisanelectrics
@artisanelectrics 2 года назад
Boom ❤
@chanellistrik
@chanellistrik 2 года назад
hai artisan
@andrewuk8363
@andrewuk8363 2 года назад
Artisan electrics v nick bundy electrical fuse board wire off who's quicker and who's looks better. Could be dummys side by side (the boards I meant)
@dimitar4y
@dimitar4y 2 года назад
looks nice but lacks that consumer panel clean look for sure.
@wroteboat
@wroteboat 2 года назад
perfect nick super job and with adam not there bye bye now
@andrewuk8363
@andrewuk8363 2 года назад
It's industrial and not in your house so doesn't have to look anything other than dirty in no time at all nick....
Далее
Getting Bored Of These Now
9:08
Просмотров 14 тыс.
ROLLING DOWN
00:20
Просмотров 5 млн
Hugely Under priced this job!!
18:12
Просмотров 34 тыс.
WE BOUGHT A STOLEN CAR THAT TRIED TO OUTRUN THE POLICE
23:19
Over The Top? DATA Cables In Domestic
16:04
Просмотров 66 тыс.
Crush and screen rock
1:35:00
Просмотров 464 тыс.
I Invented Something That Actually Works!!
21:30
Просмотров 39 тыс.
Being Stalked - So I Did This...
20:39
Просмотров 25 тыс.
The Ultimate Builder Tool Van! 🚐
2:30
Просмотров 8 тыс.