Ideal Icos / Isar Boiler Service - HF FAULT CODE - Leeds Plumber - No Hot Water 

Allen Hart
Подписаться 125 тыс.
Просмотров 38 тыс.
50% 1

Ideal icos boiler service. Today we're going to do a service on a Ideal icos open vent heat only boiler.
It also has a HF Fault. Say Fault on Ideal Isar. NO HOT WATER, NO CENTRAL HEATING.
This boiler's also got a HF fault, or an FH fault alternate. On the display it goes FH or HF. Whichever way around. And that's normally, it could be PCB, it could be circuit board. Instructions say it could be circuit board, and it shows you how you can test for that. But it's normally electrodes. And we're going to change the electrodes on this job anyway. I think boiler's about 13 or 14 years old. So it's about time to have the electrodes done.
We're going to strip this down and we're going to do a full service on it. If you're going to take a case off a boiler you must be Gas Safe registered and competent to do so. We've also done... There's electrical checks on this, and they are...
They are?
What do I need to do?
Oh! Okay. So we need to turn the boiler off at the spur, and take the fuse out, keep that on you.
We did a video, didn't we, on safe isolation?
Yeah.
But what we're doing with this case now, with this magic pen?
Checking if it's still-
PUP. What's PUP mean?
PUP. PUP means is prove, use, and prove.
So we're proving the pen works. We're going to use the pen. And then we would prove the pen again. And that's just a Fluke voltalert.
We just got a couple of screws underneath here to take this front cover off. And then this front cover just lifts off. And it's the Ideal icos HE 18 kilowatt open vent boiler, or heat only boiler.
So Richard's just removing four screws. Two on the bottom. Two on the top. And then we're just going to take that front cover off. We've also got some bits for this. So we've got the electrode kit and then we've got the electrode flamesensing. And we've also got a new condensate trap because the other one is blocked. It's blocked there but we'll talk about that soon.
We've got a problem with this boiler. This boiler's gurgling. And if we take these screws out of the bottom here water will come out of here because this pipe underneath... here, that pipe... is blocked. So we need to try and clear that blockage. But once we've done that, I'll show you inside here. And we're also going to change these as well.
Always read the installation and servicing instructions. And in there it'll tell you exactly what you need to do. So we're just going to take out this screw here. I'm going to take off that pipe there. There's also some leads that needs unplugging on there. Careful with that. Just check all the seals. Replace, if needed. We've then got some screws, or bolts, or nuts at back. Three. And then three screws at front. These ones. Just that there.
And that's your burner. Just be careful with that. And if we have a look inside there. Look at all that. So that's the old probe there. I'm just going to change that one. So it's all stripped down now and we've changed the electrodes. If this was the combi, so if this was the isar, there would be a little valve in there. I'll just show you. There'd be a Schrader valve in the back of there and you'd pump the expansion vessel up as well. Drain the boiler. Pump the expansion vessel up. On this one it's got a remote expansion vessel there. So, what we're going to do, we're going to drain it down and we're going to pump that one up instead. And just check it.
Just going to remove these screws now and take this front cover off. We just need to clean inside there. If you can see in there, we've still got a puddle of water in there. And as I say this were full of water. I've also got some new pins because the one in the boiler snapped. So I've got some new pins as well. They're in now. I have washed that through a bit, but we need to wash it a bit more. And as I always say, this should only be done by a Gas Safe registered engineer or somebody who is competent to do so. We will be testing this with all the testing equipment. We've got a flue gas analyzer and we'll be testing this. So please, please do not DIY with gas. It's just not worth it for the sake of how much it cost to get somebody who can do a good job for you. But it's very important to get it serviced. So if you've got one of these boilers then please give your local gas engineer a call and get them to come and do your service.
Just put the burner back on there. We've still got the condensate trap to take out. We're going to do that last. And then we're just going to put the fan back in now. Just need to nip that back up and also tighten the fan back in. We've put all the leads back on. And I still need to do that trap underneath here.
We're just going to put front cover back on now. And then that pipe up top there is where we need to check this. So that pipe on the top is where we check this one with the flue gas analyzer. So yeah.

Хобби

Опубликовано:

 

17 июн 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 88   
@davidoshea1536
@davidoshea1536 4 года назад
Great video as always Allen 🌟, looking forward to seeing the next one 🔥♥️
@AllenHart999
@AllenHart999 4 года назад
Thanks so much!
@simonmander4314
@simonmander4314 4 года назад
I find it quite common to find the black sheath on the lead to the sensing electrode is breaking down on these. But not hard to replace it.
@dangas6422
@dangas6422 4 года назад
Richard has awesome portfolio 😍😍😍😍
@AllenHart999
@AllenHart999 4 года назад
Richard will do really well. Thanks for the comment.
@paulkelly3254
@paulkelly3254 4 года назад
He will find the rest easy if he’s starting with the icos😆 good experience
@paulkelly3254
@paulkelly3254 4 года назад
Get him to change the pump on an isar😆 see if he’s still smiling then, or a PRV on a Worcester junior that’s 14 yrs old😆
@SalimKhan-gk1fh
@SalimKhan-gk1fh 4 года назад
Everyone is quick to slag off the ideal isar but I’ve seen a few go 10 +years without any trouble at all Just goes to show the importance of PROPER servicing, not just do a quick FGA then p...s off !!!! I looked at an ideal logic today,serviced every year for seven years and believe it or not I was the first to remove the burner assembly and flush out the heat exchanger!! , u won’t believe the crap that came out! Sounded a lot quieter afterwards
@hdhanji8006
@hdhanji8006 4 года назад
Agreed, the problem rests with customers not wanting to pay the right amount for a proper service and engineers resorting to probe and go jobs which brings down standards in the industry. Manufacturers partly to blame too for allowing fga readings to mitigate a strip down service - as we all probably know, a ratio of 0.004 is still too high and will read much lower if serviced properly
@maxnavsa4470
@maxnavsa4470 4 года назад
@@hdhanji8006 too many shit engineers who want the big money and then do quick shit job and piss off to the next victim to rip them off.
@SalimKhan-gk1fh
@SalimKhan-gk1fh 4 года назад
max navsa yes well said max, that’s the point I was getting across, like the 1st proper service I done on the logic after 7 shit ones
@neo_265
@neo_265 3 года назад
Just love watching this with subtitles on.....it loves your accent. “Richard just removing farts cruise tilt bomb on top....”!!!! Hahaha
@AllenHart999
@AllenHart999 3 года назад
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@jimmorris5700
@jimmorris5700 4 года назад
Can I add my penny’s worth , about gas boilers . ideal concord 37 years old so time to change ! waiting for free swop never came (OAP but no benefits ) then last year son in law stripping flats offered me a 2/3 looks like new vaillant ecotec 38. so didn’t choose it ! stripped fitted an certified , so seen all inside , and well I’m impressed the insides look far far superior to any Allen worked on in pics , well placed good fittings an well only small criticism is rather tight fitting an hard to remove water filter BUT. If that’s the only complaint it’s a damn good piece of kit . Now one point I live in a soft water area an don’t suffer the hard water problems Allen shows a lot , at new it was teamed with a magnaclean so that’s there as well , not bad for £50 lol . So a totally unbiased non expert or plumber review of the best boiler on the market .
@Rebasandofronteras
@Rebasandofronteras 2 года назад
Amazing videos Allen really educating and full of helpful information! Question:is it normal for this boiler to fire up every 5 to 10 min all night?
@shaunhartnell2696
@shaunhartnell2696 3 года назад
I switched one off this week.. 24 kw version leaking on the main hx where it joins onto the burner assembly as well as a noisy gas valve.. and kettling
@snoman1999
@snoman1999 3 года назад
Hi Shaun is this an expensive operation as I think this is what is wrong with ours (same model) TiA 👍🏽
@zxcherry7356
@zxcherry7356 7 месяцев назад
Hi Allen im doing one of these boilers keep getting an intermittent LF fault.?
@chrissyboast3008
@chrissyboast3008 5 месяцев назад
I have an ideal Icos …it comes on ..burns for ten minutes then goes off. Comes back on again, but goes on and off every five minutes thereafter….can you ad use as to what needs doing ?
@bodrulamin1
@bodrulamin1 5 месяцев назад
How much does something like this cost in full. I have the same boiler which is displaying a c fault with a flashing burner light. The issue is the radiators are getting hot whilst the thermostat is turned off. Any help please. I tried resetting and also changing the thermostat to a brand new one. It’s a Honeywell thermostat system.
@adamhay1428
@adamhay1428 4 года назад
Not bad boilers if looked after. I take the trap off and flush thru into a bucket below washing the burner and sump out into it.
@illuminate06
@illuminate06 4 месяца назад
How do you put that boiler on service mode high and service mode low?
@karenwernham3668
@karenwernham3668 Год назад
so we have water leaking from the right hand side of the boiler at the bottom, how much would it cost to call plumber out to fix
@kennethireland1807
@kennethireland1807 2 года назад
Why does my boiler only run for 5 mins and then shuts down it keeps doing this . I have a new water pump , programmer , thermostat pcb board in the boiler . I have the thermostat set on 30 degrees and the boiler stat set on no 5 which is maximam . It takesd hours to heat the house as it keeps stopping any ideas
@toby7738
@toby7738 4 года назад
Hi Allen. Thanks for the video and the time and effort you put into this channel. After replacing the fan I LDF the gas connection to the fan and run the boiler to check for gas soundness before replacing the inner cover as this gas connection is disturbed during the service. On one occasion the rubber grommet in this connection, which is visible in your video, fell out so LDFing this connection afterwards reassures me the grommet is still there and seated correctly. Obviously a tightness test would be of no use as this gas connection is north of the gas valve. Just wondering if and how you check this.
@rayc1503
@rayc1503 3 года назад
Use a combustible gas leak detector a.k.a gas sniffer
@MrElliott1979
@MrElliott1979 Год назад
Why ? The fan pulls the gas into the burner
@wobble00710
@wobble00710 Год назад
Hi, top video If a boiler readings check our etc, is there really a need to strip down burner / heat exchanger and flush etc. In a service? Just regarding combi boilers in general, not the boiler in video.
@CorradoTDI
@CorradoTDI Год назад
These need a good clean every 2 years - debris build up in the sump and then block the trap. You need a soft brush to clean the heat exchanger which wasn't shown.
@Brijoolz
@Brijoolz 4 года назад
We have a local authority who mostly had Ideal Turbo 2 boilers, that we replaced with these. Not sure which was worse. I had an Ideal Minimiser for about 8 years. Another poorly thought out boiler. Impossible to clean properly (believe me, I tried!). The burner is upside down. If they’d turned it upside down it might have worked ok. But the oxide used to pile up around the electrodes and make it fail. That gravity stuffs’ a bit of a bu**er!
@SRobinson1485
@SRobinson1485 2 года назад
Hi alan my ideal is showing H1 Fault what could that be
@TheIcebon
@TheIcebon 4 года назад
Those fins in the heat exchanger if left un serviced/cleaned cake up like cement, which most are like that I go to
@AllenHart999
@AllenHart999 4 года назад
I do not think these had ever been done. Thanks.
@victor-hn1bh
@victor-hn1bh 3 года назад
Nice to see full strip down, unfortunately, many local authorities and private customers are not prepare to pay for the extra time needed to do such a professional job sad but true. Money, profits, determine how long one can spend on each job. It's a piety but there lot of truth in it. Most companies allow only 1 hour for a service. We your draining down and repressureizing expansion vessel, depending on system some times that can take time on its own.
@waseem4030
@waseem4030 Год назад
Hi Has anyone experienced with ideal icos he12 boiler? It is giving H6 error, I tried to find out which error is it but couldn’t find I changed PCB still problem didn’t go. Can anyone help me out? Thanks
@liverbird46
@liverbird46 4 года назад
Hi Allen, hope you don't mind me asking, what's your opinion of the Ideal Vogue boiler?
@AllenHart999
@AllenHart999 4 года назад
Anne Evans Amazing Boiler
@liverbird46
@liverbird46 4 года назад
Thank you
@keithlowe5245
@keithlowe5245 4 года назад
Hi Alan, wondered why you don’t show your electrical safety checks, would be good for the folks, cheers
@AllenHart999
@AllenHart999 4 года назад
Keith Lowe They are in this video, No point showing same thing over and over. Thanks ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-fRai6J4UcQ4.html
@efosajacob1286
@efosajacob1286 9 месяцев назад
Hi. I have the same boiler that you were working and its dripping water, what do you think the fault is?
@AllenHart999
@AllenHart999 9 месяцев назад
It could be lots of things. Please call someone out to check it out. Thanks.
@paulkelly3254
@paulkelly3254 4 года назад
The icos and isar got a bad name because of warmfront schemes, loads fitted but maintenance not as good as it should be. I service a friends which he’s had since 2005, not much gone wrong with it, just electrodes etc, important to have your boiler serviced PROPERLY, not a FGA test then bugger off☹️
@MasuMaurycy
@MasuMaurycy 4 года назад
Maybe You should clean a top of the hex befor u replace those electrods ? It will be much easier.
@darrentaff8374
@darrentaff8374 4 года назад
Hi Allen i have the same boiler it's started a banging sound like pipes knocking together if that makes sense . We've relyde on the emersion to get hot water . Till better times . Any advice cheers
@AllenHart999
@AllenHart999 4 года назад
darren taff You need to call someone out to check it, Could be loads of things. ❤️
@darrentaff8374
@darrentaff8374 4 года назад
@@AllenHart999 thank you
@kevincranfield5235
@kevincranfield5235 4 года назад
Your external pump will be faulty
@darrentaff8374
@darrentaff8374 4 года назад
@@kevincranfield5235 thank you
@claireh8415
@claireh8415 2 года назад
@@AllenHart999 Weve got the same boiler and same problem as above, however we still have hot water but no heating. A family friend who is qualified had a quick look + said the heat exchange is gone. He advised us its not worth fixing and to get a new boiler, Im wondering would we still have hot water if heat exchange is gone?
@timhancock6626
@timhancock6626 4 года назад
Let not forget the PCB got as far as Version 9 before it was fully reliable. I can only say that they put right virtually all of the things they got wrong on the Icos/Isar on the Logic. Don't mention the blue PCB...I mentioned it once, but I think I got away with it....
@steowens8243
@steowens8243 4 года назад
Yh but then more faults with the logic occured 🤣
@hosseinkarimzadeh3085
@hosseinkarimzadeh3085 3 года назад
hi your purpose of that part to clean main exchanger you open fan take top cover but you did not show how you clean m exchanger
@AllenHart999
@AllenHart999 3 года назад
pour water down. Thanks.
@kennethireland1807
@kennethireland1807 2 года назад
i have no fault lights up just the C symbol and that stupid blue light flashing at me waiting for it to start again
@geoffreyhoward-smith9486
@geoffreyhoward-smith9486 2 года назад
Hi Allen I want to change my heat exchanger for a new one do I have to drain the complete water system down?
@AllenHart999
@AllenHart999 2 года назад
You need to call a gas Engineer. Thanks.
@nickirlam4811
@nickirlam4811 4 года назад
👍👍👍❤️
@mistermartin82
@mistermartin82 4 года назад
something is very very badly wrong if the earth case of a boiler is showing as live with a none contact tester. if it did show live I'd leg it until gas and electric were turned off
@AllenHart999
@AllenHart999 4 года назад
I had this on a job once, All the earth had been wired to the live.
@dickiedubs3137
@dickiedubs3137 15 дней назад
I do wonder why ideal make boilers, apart from.the new vogue I struggle naming a good one....the icos and isar are horrible
@milkman100001
@milkman100001 4 года назад
the condensate trap on these boilers were a joke. having said that i have one still working in one of my rented properties.
@AllenHart999
@AllenHart999 4 года назад
What issues did you have? Thanks.
@milkman100001
@milkman100001 4 года назад
@@AllenHart999 you couldnt clean them out.just very hard access
@justsendmelocation5068
@justsendmelocation5068 4 года назад
Ideal shytcos Them insulation pads fall into the burner because the retaining clips perish. This causes the burner to cause a hole in the combustion chamber.
@maxnavsa4470
@maxnavsa4470 4 года назад
I had the isar, one of the worst boilers you can ever get. I had problems from day one. Customer service by ideal was even worse. I would have to call them atleast 4 to 5 times a year. Me my my young children spent So many days and weeks without heating in the midst of cold winters. Ideal were never bothered. Always get a qualified engineers to fix/service boilers but i can see why people resort to diy. Some really bad gas men out there giving the trade a bad name. I had my baxi serviced last week by baxi them self and the trap is still full of gunk. Im sure its supposed to be cleaned as part of the service. Allen your the only decent gas man that does top job.
@trevor311264
@trevor311264 3 года назад
No, you only need to be gas safe registered if you are being paid to do it, otherwise you only have to be competent.
@AllenHart999
@AllenHart999 3 года назад
Was does competent mean?
@trevor311264
@trevor311264 3 года назад
@@AllenHart999 only a court can answer that one!
@johnboy1232
@johnboy1232 4 года назад
First time I have seen a heat only boiler but the combi versions were possible the worst boiler ever . I worked on them a lot , cramped to work on luminium heat exchanger that leaked from 5 years onwards an absolute money pit . That trap was so shallow as well The retaining pin design was changed to the type you fitted by a manufacturer visit as I believe there was a problem with the insulation panels falling down . As a general rule not worth bothering fixing and I used to fully strip and clean them every year .A disaster for Ideal that tarnished their brand for years.
@frankyparker6004
@frankyparker6004 Год назад
Ye harth them never been servist
@mrbachittarsingh9243
@mrbachittarsingh9243 4 года назад
Icos not too bad but the isar is the devils work! Horrible boiler.
@petersutton3054
@petersutton3054 4 года назад
Absolutely nightmare boiler if not looked from the start riddled with problems
@AllenHart999
@AllenHart999 4 года назад
This one was full of water as condensate was blocked, Not sure it had ever been serviced. Thanks for the comment.
@rayc1503
@rayc1503 4 года назад
The condensate trap must have been designed by elves. I carry a couple 9n the van. Pcb electrodes and insulation retaining clips. Tbf lack of servicing gets these boilers. To recharge the ev is a pain in the ar*e the aav is even worse. Still all bread 'n' butter right. Keep all the burner seals and gaskets as van stock they rarely last. 👍 Allen great Hart 🙂
@galaxydave69
@galaxydave69 4 года назад
The work of the devil
@AllenHart999
@AllenHart999 4 года назад
Thanks for the comment.
@farukadam1696
@farukadam1696 4 года назад
Probably this boiler need replacing absolutely rubbish boiler Regards Faruk
@AllenHart999
@AllenHart999 4 года назад
It’s been faultless really for 14 years. Thanks.
@anthonycannon740
@anthonycannon740 4 года назад
To be honest they are a good boiler if serviced properly,
@olalekanoyedokun4494
@olalekanoyedokun4494 3 года назад
I had a call from customer that hot water come hot and cold. When I got there, I found out that the boiler was Ideal Isar, installed in a cupboard and looked unkept. When I open the casing, there are lot of corrosion, rusty and has been leaking for only God knows. It was so compact that you cant even get your hands around the components. Why would anyone installed this type of boiler in a tiny cupboard. I quickly put the casing back and zoom off. I would not touch that on Friday afternoon
@frenchfrench4514
@frenchfrench4514 4 года назад
Scrap the boiler or walk away. You can leave this boiler thinking its safe and then the next day the burner box/heat engine gasket/seal (top or bottom)will fail and it will be leaking products of combustion the day after you think you've left it safe. There's no way of knowing when this seal will fail and you can't inspect it or change it, its put together in the factory and is hidden (especially the bottom one) and corrodes from the inside out I worked for Ideal for 4 years, I've condemned 100s of these boilers. That would be my advice anyway, this boiler can get you into trouble or give you a bad name.
@victor-hn1bh
@victor-hn1bh 4 года назад
Would you carry out co checks around burner and bottom of heat exchanger, This is why it's good to take analyser records / print and store . This boiler he worked on in This video there say properly had sludge due to age and No CH filter or hibitors added annually.
@frenchfrench4514
@frenchfrench4514 4 года назад
@@victor-hn1bh Yes, i used to put the probe around the orange seals and if I detected anything the boiler would be condemned. A good way to tell is immediately check the inside of the inner case to see if it is stained anywhere, if it is then the boiler is leaking fumes usually. I dont not work on these boilers now though, I only worked on them because I worked for Ideal, I wouldn't go near them now privately unless I was taking it off the wall.
@victor-hn1bh
@victor-hn1bh 4 года назад
Will be watching out and looking carefully when I get one of these, as I tend to work on all different models
@kevint3845
@kevint3845 4 года назад
Ideal for the skip, not a well thought out unit at all, certainly not designed for ease of working on ie maintaining them, taken loads of them out, hopefully even more soon.
@allenhart5605
@allenhart5605 4 года назад
Should be good now for a few years.
Далее
2DROTS vs WYLSACOM! КУБОК ФИФЕРОВ 1 ТУР
07:25
LF Code Ideal Icos Hints and Tips
16:32
Просмотров 14 тыс.
Hidden heating leak that can't be found!!
4:49
Просмотров 21 тыс.
Plumbers from hell left this behind
14:56
Просмотров 75 тыс.
Amazing weight loss transformation !! 😱😱
0:24
ДОМИК ИЗ АРБУЗА #юмор #cat #топ
0:40