Тёмный

Ignition lockout baxi solo  

The Mental Gas man
Подписаться 3,7 тыс.
Просмотров 10 тыс.
50% 1

All videos are for the intended use by gas safe registered engineers only, such procedures should not be copied or performed by non competent and unqualified persons.
3T Gas Ltd - Heating and Boiler repair specialists in West Midlands
www.3tgas.co.uk
0800 9997870
Instagram the_mental_gas_man
MENTalk mental health advocate
www.MENTalk.online
Baxi ,Worcester Bosch , Viessmann, vaillant, ATAG, main , megaflo, ferroli, Ravenheat, navien , grundfos, wilo, Heatgeek, Intergas , talon , heatrae sadia , adey, boiler repairs , boiler servicing, central heating , boiler installation, new boilers , power flushing , vdi2035, magna clean , adey chemicals , faulty pumps , faulty pcb’s , diverter valves , balancing , efficiently , gas engineers
‪@thementalgasman3tgasmainte317‬

Опубликовано:

 

11 фев 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 28   
@normanboyes4983
@normanboyes4983 2 года назад
That is an amazing and a sad story too. The landlord had clearly been ignoring the tenants reports of the problem and he was then expecting successive gas engineers to ‘sort out’ any issues on periodic inspection visits. Tenants run the risk of having notice served on them if they are too much bother. Amazing that the boiler was still working at all and a shame the previous gas engineers did not follow through so diligently as you did, but I figure they would have met resistance from the landlord for any additional work over and above the inspection fee. The tenant struck gold when you turned up - let’s hope the landlord implements your recommendations. Good job.😀👍
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Booked to fit parts looking forward to getting this one going
@normanboyes4983
@normanboyes4983 2 года назад
@@thementalgasman3tgasmainte317 I love a happy ending.😀👍
@huyongquan6554
@huyongquan6554 Год назад
shame for landlord, not for the previous engineer who be instructed just for safety check and can not get paid for additional job.
@leehingley380
@leehingley380 Год назад
Appreciate the upload, this video helped me diagnose my problem and resolve with a burner clean (was worse than the one in your video) Top man 👏
@aminsajawal3935
@aminsajawal3935 2 года назад
I missed out on that 1 lol 😂. Great video as always
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Saved the best till last 😂
@frankiepc8119
@frankiepc8119 Год назад
I was told by Baxi never to wash the burner out with water because it can crack when heat is applied and possibly if not perfectly dry water could trickle into the fan exhaust and find it’s way into the electric motor . Have you ever been told this and is it something you are still doing now , nice to hear your comments . Regards Frankie
@stephenayers8242
@stephenayers8242 2 года назад
Can't believe the tenants just accepted this!!! Crazy Landlord just trying it on👎🏻 Good vid, would have been good to see all working after👍🏻
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
I’ll be going back to replace parts so I’ll upload the 2nd part
@ryandow3954
@ryandow3954 2 года назад
@@thementalgasman3tgasmainte317 Looking forward to the 2nd part to this, will be great to see it actually being sorted after 6 years 🙈😂
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
@@ryandow3954 I should be doing it tomorrow, I’m a little concerned that I’d it’s been leaking for a long time that the condense water may have Damaged bottom of hex where it’s been Seeping through , well soon find out when I pour a litre of water through the flue 🤷🏽‍♂️
@ryandow3954
@ryandow3954 2 года назад
@@thementalgasman3tgasmainte317 That's a good point, on the video the condition inside didn't look too bad for it having been leaking all that time so you might be lucky! I'll keep my fingers crossed 🤞😎
@zaramohammed1516
@zaramohammed1516 24 дня назад
What if light is flashing red
@davebayliss3142
@davebayliss3142 2 года назад
This happens all the time , I feel your pain 😡
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
I’m used to it now customers bill doubled tho 💯
@joncoke8208
@joncoke8208 2 года назад
Hi mate ive got a potterton promax(same boiler) which fires fine but after 20 mins starts making vibrating noises then goes off, co2 was 7.2 whats your thoughts
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Co2 is too low , that needs to be around 9% , after about 20 mins it should be modulating down hence why co2 is so low , these gas valves are very sensitive to adjustment 👍🏽also check condense is clear but my money is on the co2 being to low
@joncoke8208
@joncoke8208 2 года назад
@@thementalgasman3tgasmainte317 thanks mate much appreciated arent these factory set gas valves which we can’t adjust?
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Officially yes , I had a baxi engineer out on warranty call yrs ago to one of these boilers with co2 way out engineer just turned up and adjusted the valve advised that’s what they always do , I’ve had baxi techs tell me do it aswell in the past
@joncoke8208
@joncoke8208 2 года назад
Fuk doing that on a landlords cert! Would of walked in and back out, whats the sump seal like tho change?
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Easy enough 4 bolts and it drops down , depends on weather the bottom of the hex is damaged as to weather it seals again 🤷🏽‍♂️
@mike004692
@mike004692 2 года назад
honestly some land lords need jailed
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Agreed 😏
@davebayliss3142
@davebayliss3142 2 года назад
Flow switch on this boiler is in a really stupid place , bad design
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 года назад
Agreed there not the easiest to remove
@davebayliss3142
@davebayliss3142 2 года назад
And electrics right under the water
Далее
Baxi solo part 2 fitting the sump
7:54
Просмотров 4,1 тыс.
UNO!
00:18
Просмотров 716 тыс.
EASY Potterton Promax IGNITION FAULT REPAIR
5:08
Просмотров 2 тыс.
The Bearded Plumber° Ignition Lockout/Error
3:21
Просмотров 2,8 тыс.
Potterton promax main heat exchanger replacement
8:59
Baxi faulty fan & air pressure switch
14:18
Просмотров 10 тыс.
Baxi Solo 2 No ignition
4:49
Просмотров 10 тыс.
Potterton Suprima boiler fix
14:40
Просмотров 31 тыс.