Inside an Enphase Micro Inverter 

Ben's Solar and Battery
Подписаться 6 тыс.
Просмотров 31 тыс.
50% 1

Let's take a look inside an Enphase IQ7+ micro inverter!

Опубликовано:

 

20 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 143   
@DavidPozEnergy
@DavidPozEnergy 3 года назад
I love the music while cutting around the perimeter. Thanks for taking it apart.
@benssolarandbattery
@benssolarandbattery 3 года назад
Haha, thanks! That saw sounds terrible...
@vinitsingh8962
@vinitsingh8962 3 года назад
@@benssolarandbattery That small thing that you took out in starting, it was a fuse. I know that because I have worked in power supplies that has same kind of fuse in it, it was shown to other repair person but they couldn't find the fault because it's a unusual shaped fuse. The second red thing is M.O.V (metal oxide varistor), Now here is what I know, I think happened there, when a high voltage surge came it make the M.O.V conductive and it short out the live and neutral phase, so that the fuse can blow up and save the whole circuit from blowing up. Now, you have to just replace, that fuse and M.O.V and bring that thing back to life. Please bring it back to life again, and do not let it end in a landfield. That video was great, I appreciate your work and time spent on it, to open it. Great man. 👍
@vinitsingh8962
@vinitsingh8962 3 года назад
Hey Davidpoz, thanks a lot for recommending this channel, But I didn't want to just see it opened up, I want to see it back in the life again and in working condition. 👍👍
@vinitsingh8962
@vinitsingh8962 3 года назад
I wish, you can do that.
@RetroElectric
@RetroElectric 2 года назад
Yes!
@KevinGebo
@KevinGebo 3 года назад
I've always wanted to see inside the IQ series micros, thanks Ben! The red disc is a varistor. They protect against minor voltage spikes by clamping voltages outside a certain range to ground. If surge is to high or too long duration they blow up (and then trip the thermal fuse that should be next to it). I only know this because last year a tree took out my overhead power drop going to my house and knocked off the neutral. With L1 and L2 still connected it caused significant voltage spikes on my 120v circuits which fried a bunch on electronics, smart switches, control boards etc. Upon investigation, every varistor (little red disc) was melted. That was a sucky day 😂
@RetroElectric
@RetroElectric 2 года назад
Me too
@murkymurph8355
@murkymurph8355 Год назад
That sounds like a bad day! How would you protect against that happening again in the future?
@sitechca70
@sitechca70 Год назад
Thanks for the work taking it apart. So much for Enphase's claim of "no electrolytics like string inverters". Bunch of them on the DC side. Early end of life failures are usually caused by electrolytics.
@DIYwithBatteries
@DIYwithBatteries 3 года назад
Thanks for revealing the schematic behind that sticky thing 😂 liked it. 👍
@RetroElectric
@RetroElectric 2 года назад
Yes. Now we don’t have to
@serversurfer6169
@serversurfer6169 3 года назад
Send it to Big Clive so he can tell us how it works! ✊🤓💜
@sergeyblinov4957
@sergeyblinov4957 3 года назад
If varistor was blown, there is a small chance, that IGBT transistors of inverter bridge weren't failed. Probably, blown varistor and fuse (in plastic "film capacitor"-like case) - may be the only failed components. About surge protection. Carefully selected varistors by voltage / energy parameters (i suggest DIY devices), and good grounding plays the main role in such protection. Also, implementing of isolation transformers (1:1) between solar array common AC output "bus" and house wiring - can increase protection level.
@RetroElectric
@RetroElectric 2 года назад
😁
@davidramsay6142
@davidramsay6142 2 года назад
Great video. This satisfies my curiosity so I will never have to take on the potting grunge. Good man.
@RetroElectric
@RetroElectric 2 года назад
Agree
@benlee803
@benlee803 Год назад
Disclaimer. I am an electronics engineer and a trained proffessional (40 years of experience) so anyone who tries anything mentioned here will be doing so completely at their own risk. I just wanted to thank you for sharing this. It inspired me to look into the very similar IQ6 microinverters that took a grid hit and took out 16 units. I shaved off the top off of the area (with my table saw, ruined my shirt) just around where you lost small cube part that came off of the board. I was able to solder in a 3.15A 300V fuse mouser part 504-SS-5H-3.15A-APH ($0.57) and a similarly located MOV mouser part number 871-B72214P2171K102 ($0.38) Soldered the leads onto the leads on the board (I carefully trimmed them). Hooked it up and it started working normally. Next I will put potting compound on this one. The next ones I will cut a hole with a hole saw directly over the location of the parts to replace. They will all be protected and probably work and the cost will be less than $100 total (including 12 pack of 805 Beer). ***I will be installing a MidNite Solar Surge Protection Device (MNSPD-300-AC Amazon $111) Close to the incoming AC power feed at the main breaker panel that should prevent this from happening again and as a bonus protect my home electronics. On a side note the MOVs used are designed to take anywhere from 1 to 15 grid events depending on the severity. This means if you lost 1 to a grid event then the other ones have used up one of their "9 Lives" it would be a great idea to try and protect the ones that are still working.
@BenMitro
@BenMitro 3 года назад
That was a pretty good tear down - thanks. Would love to see the other side of that board, but I get the work to get to it. I can't see the value proposition of micro-inverters, its like getting 23 cars to do the job of one truck...
@rowlandcrew
@rowlandcrew 2 года назад
Hi Ben, that disk is an MOV and the dark cube looks like a capacitor that was probably over- voltaged or failed. other capacitors and maybe some of those relays appear to have allowed too much voltage to be across the MOV. An MOV always flow current, just more when voltage goes up, but nonliearly and are intended to filter out millisecond spikes on the ac lines, within the limits of "small" over current or limited energy . Great entertainment watching you tear it appart.
@freethink3r
@freethink3r Год назад
Thanks for taking the time to make this video! I have always wanted to know what is inside an IQ7 microinverter
@arleneallen8809
@arleneallen8809 3 года назад
Another example of throw-away technology rather than something made to be repaired or recycled. A lot can be said for microinverters, but if its like cell phones and we just throw them away, I would prefer a central, repairable unit.
@OverUnity7734
@OverUnity7734 3 года назад
Agreed, I don't recall seeing a video detailing the savings of making AC at the panel vs making AC at a box inside the house .
@jfbeam
@jfbeam 3 года назад
Technically, it is "serviceable", but the casing will be completely destroyed getting into it. That's the trade-off for rapid manufacturing, and simple IP## sealing.
@TurreTuntematon
@TurreTuntematon 2 года назад
I think it would be very difficult to achieve repairability of these as they are sealed to withstand rain, sun, snow, moisture for 25 years. Same with optimisers from Solaredge. Then again, there should occur no repairs for 25 years.
@RetroElectric
@RetroElectric 2 года назад
Yes
@RetroElectric
@RetroElectric 2 года назад
I love taking things apart! A man after my heart!
@rocktech7144
@rocktech7144 Год назад
Component details would be COOL
@jameshancock1515
@jameshancock1515 2 года назад
Thanks for your show . you helped me decide on the purchase . after watching this the ac side would need some type of surge protection or the solar units would not work. and power surges happen her all the time. Will stick to my solar unit the way it is with out the Enphase connection to my house current that would destroy it in less than a week. do not currently have Inverter connected to the house circuits direct . using 2 separate sources of electric power
@RetroElectric
@RetroElectric 2 года назад
Agree
@wd9dau
@wd9dau 3 года назад
Not potted. Encapsulated with what looks to be Silastic. Keeps moisture away from the board.
@elmerkilred159
@elmerkilred159 3 года назад
Is that like Silly Putty?
@wd9dau
@wd9dau 3 года назад
@@elmerkilred159 No, it is an epoxy like material that consists of two liquids that when mixed end up as a flexible solid when it hardens. Silly Putty does not harden.
@knurlgnar24
@knurlgnar24 2 года назад
This was potted, not encasulated. Encapsulation is a rigid material that acts as the case and is the sole protective layer, potting is something that fills a mold and the mold is left on. High quality potting materials have a low durometer when cured like what we see here.
@offgridwanabe
@offgridwanabe 3 года назад
Hey save those 4 capacitors they will come in handy.
@RetroElectric
@RetroElectric 2 года назад
Your shop must look like mine!!! 😂😂😂😂
@TomCee53
@TomCee53 2 года назад
Not if he knows nothing of electronics.
@leen.3785
@leen.3785 3 года назад
glad i didnt try taking them apart, that looks like a nightmare...
@benssolarandbattery
@benssolarandbattery 3 года назад
Definitely terrible. I looked for other people who'd done it with the IQs on RU-vid, couldn't find anyone. Now I know why! 🤣
@billjohnson3344
@billjohnson3344 3 года назад
What was the nature of the condition that caused this damage? Curious why enphase won't warranty this. They claim to have a 25 year warranty (in the US), and this is a new model.
@benssolarandbattery
@benssolarandbattery 3 года назад
It was a grid surge that took out all of the micros in the system. They do recommend installing surge protection, but say that the micros should be able to withstand small surges. This system did not have a surge protector. Whether that would have saved it, we'll never know.
@SmedleyButler1
@SmedleyButler1 2 года назад
what kinds of surge protection would be best? the kind northern Arizona wind and solar have in all their kits, that might be from midnight solar that look like police blue lights?
@KetansaCreatesArt
@KetansaCreatesArt 2 года назад
Hello Ben. Its very obvious that this is just like a DC to AC (or AC to AC booster) inverter, with variable input. I dont know whether you took it appart to study the electronics, or just fun, but this can be easily repilicable with simple board modules available in market right?
@davesmith2233
@davesmith2233 2 года назад
I think there's a helluva lot more to it than that. I'd really like to see some detailed photos of the circuit board to see what's in there, and in particular what their "55nm ASIC" actually is, I'd have expected an R-series ARM to drive things rather than a complete ASIC... is it a creatively-described FPGA with a soft-core to control things?
@jameshancock1515
@jameshancock1515 2 года назад
In order for me the consider this now it would have to be covered on the ac side under the warranty or a protection circuit installed on that side that can be reset or replaced.
@billd7829
@billd7829 2 года назад
Wow thanks. I been wondering if there are circut boards in them. Gotta bunch of them for scrap. Not worth the time and effort to take em apart.. thanks for the great video..
@jameshancock1515
@jameshancock1515 2 года назад
that being said I still save $60 per month on my electric bill and this is only my first 12 v build. will add on till I have 48 v system then connect it directly to the house with a grid disconnect interface.
@grantmyers7593
@grantmyers7593 2 года назад
I have 8 of those from a surge that happened to me.
@RetroElectric
@RetroElectric 2 года назад
😬
@Just_An_Idea_For_Consideration
@Just_An_Idea_For_Consideration 2 года назад
I bet they now wish they had warrantied that unit
@RetroElectric
@RetroElectric 2 года назад
👍
@vinitsingh8962
@vinitsingh8962 3 года назад
Maybe, that blown thing was fuse. I have repaired power supplies, they have similar fuses. And 2nd red colour popped thing is M.O.V (metal oxide varistor).
@vijaypalsingh5371
@vijaypalsingh5371 2 года назад
Very nice information .
@afsalpoozhithodi3429
@afsalpoozhithodi3429 2 года назад
Thank you very much man..
@smbrob
@smbrob 2 года назад
If it did get problems because of the surge from the connected AC, then why was this the only one that broke? Because they are all connected in parallel, so every inverter would get the same high voltage. So I say it just broke and should be replaced.
@benssolarandbattery
@benssolarandbattery 2 года назад
On this install, 29 out of 30 died. If there's one one that's dead, that's most definitely a warranty issue.
@Dutch_off_grid_homesteading
@Dutch_off_grid_homesteading 3 года назад
heya niice to see it wans at the inside
@okidoki1394
@okidoki1394 4 месяца назад
Excuse me but I see u’ve no idea mate! This burnt red dish is a varistor that must protect against high voltages. It’s highly probable your micro inverter has suffered a high voltaje punch, probable directly from an irregularity in the power net or, perhaps, by a discharge Inma storm… 😬🤯
@scottswf238
@scottswf238 2 года назад
Great channel! I’m curious, saw your encharge videos, can you set up one up connected directly to a main panel that the battery couldn’t run if all circuits were on? Assuming then in a power failure it would fault because it couldn’t manage the load then you could turn the proper circuits on off and leverage it? I’d like to avoid a sub panel.
@benssolarandbattery
@benssolarandbattery 2 года назад
Hey thanks Scott! I don't believe it would work like that. It needs to be hooked to the smart switch to be managed, but also because the encharges only put out 240v, the smart switch has an autotransformer that kicks in when the grid is down. Hate to say it, but you may be better off running a sub panel.
@scottswf238
@scottswf238 2 года назад
@@benssolarandbattery thank you! I’d have the smart switch either way. Just hoping to avoid going with 3 encharge 10s (we have a 5 ton AC and pool pump) or a sub panel. I was wanting to start with one Encharge 10 and then add on in future years.
@benssolarandbattery
@benssolarandbattery 2 года назад
@@scottswf238 you could add a load control panel such as a Lumin and run a smaller battery that way. I assume you'd want to use your air conditioner on battery, but pool pump might not be necessary.
@scottswf238
@scottswf238 2 года назад
@@benssolarandbattery really helpful. Thank you!
@thedavesofourlives1
@thedavesofourlives1 2 года назад
Throw in pot of warm water to loosen potting compound
@bp4888
@bp4888 2 года назад
Yeah the burned component seems to be a MOV (metal oxide varistor) that functions like a surge protector. Sometimes it malfunction and mess up the whole inverter.
@leen.3785
@leen.3785 3 года назад
was the string blowing breakers every time your turned them back on?
@benssolarandbattery
@benssolarandbattery 3 года назад
No, but one of the breakers was tripped when we got there. Didn't trip when reset.
@fisherus
@fisherus 3 года назад
Makes for a good live mouse trap, Ben, just think of the possibilities of repurposing. Oh, I forgot you're not an off-grid prepper
@benssolarandbattery
@benssolarandbattery 3 года назад
I may not be off grid... yet. 😉
@GurdeepSingh-bu6ee
@GurdeepSingh-bu6ee 3 года назад
Hey. Is it possible that the wiring connector was loose or not made right. Created spark and toeasted. My gut feeling say so. So, please make sure the connectors are made tight and snap sound is heard.
@RetroElectric
@RetroElectric 2 года назад
Good point
@agustrogberg842
@agustrogberg842 3 года назад
Nice video!!! I was wondering if someone connected DC input to a battery to use it as snap inverter during night
@benssolarandbattery
@benssolarandbattery 3 года назад
Thanks! Definitely not. The entire array (minus 1 panel) went out at the same time during the day, plus it was a customer who would most definitely not attempt that.
@ntnblr
@ntnblr 3 месяца назад
What is the reason for microinverter being dead, they have 25yr warranty
@benssolarandbattery
@benssolarandbattery 3 месяца назад
Grid overvoltage, or grid surge. Read the fine print!
@williamjohnston3770
@williamjohnston3770 3 года назад
Wow I'm so surprised that they won't warrant it. I've replaced 2 or 3 in the last year or so. What was their justification? So sorry to hear that and thanks for sharing. This makes me think twice about installing Enphase equipment.
@benssolarandbattery
@benssolarandbattery 3 года назад
Apparently grid surges aren't covered under warranty. Surprised me too. It was a little suspect though, as 29 out of 30 in the system were dead at the same time.
@williamjohnston3770
@williamjohnston3770 3 года назад
Ben I'm so surprised about this. I've been installing them for over 10 years.
@benssolarandbattery
@benssolarandbattery 3 года назад
@@williamjohnston3770 8 years here, never once had them deny a claim. Also never had 29/30 micros be taken down by a surge before!
@maddeusdoggeus1
@maddeusdoggeus1 2 года назад
@@benssolarandbattery was there anything that could have been done to prevent this? I was just about to pull the trigger on these or the new 8’s…… A little worried now…😳
@benssolarandbattery
@benssolarandbattery 2 года назад
@@maddeusdoggeus1 I would definitely recommend adding a surge protector to the system closest to your service entrance. It could have helped in this situation for sure. That being said, stuff happens. Whacky voltages can get through in the right conditions.
@StatmanRN
@StatmanRN 2 года назад
I think this just talked me out of using them.
@benssolarandbattery
@benssolarandbattery 2 года назад
To be fair to them, out of over 10,000 of them we've installed, this was the first time something like this has happened.
@SmedleyButler1
@SmedleyButler1 2 года назад
could a surge protector like northern Arizona wind and solar use, prevent this?
@benssolarandbattery
@benssolarandbattery 2 года назад
It could, depending on how big of a surge it was.
@rogerkerkmann
@rogerkerkmann 3 года назад
It's strange they put a varistor in there to protect it but if you can't fix it what good is it 🤔🙄👍
@benssolarandbattery
@benssolarandbattery 3 года назад
Is it actually a varistor? I was just guessing. 😁
@rogerkerkmann
@rogerkerkmann 3 года назад
@@benssolarandbattery yeah looks like it there designed to absorb the surge and then blow the fuse I've done a lot of varistor bypasses in the hospital goes between neutral and hot causes hell with leakage current, looks like it melted down the fuse and holder
@RetroElectric
@RetroElectric 2 года назад
Haha
@elmerkilred159
@elmerkilred159 3 года назад
That looks pretty simple in design to replicate. What is the round disk gizmo?
@benssolarandbattery
@benssolarandbattery 3 года назад
I have no idea!
@TurreTuntematon
@TurreTuntematon 2 года назад
Yeah right. They have worked 10 years on the ASIC and software and is even more advanced with the IQ8. And then off course the IP.
@ridemfast7625
@ridemfast7625 9 месяцев назад
@@TurreTuntematon And yet multiple people in this thread mentioned multiple Enphase MI's being taken out in one event. And why is the communication/Envoy warranty so short? And their MI's have to be online 100% or no warranty.... Thats "advanced"? hahaha
@TurreTuntematon
@TurreTuntematon 8 месяцев назад
@@ridemfast7625 M series? That’s like the first model of iPhone so yes it was not that advanced back then. Now it’s IQ8.
@ridemfast7625
@ridemfast7625 8 месяцев назад
@@TurreTuntematon Old Iphones dont burn up.. And iPhones have been available a lot longer then any Enphse MI.. And IQ's are limited on solar panel size. And theirs the Envoy short warranty you neglected to comment on. And IQ8 has challenges when coupled with other manufacturer batteries.. And how long have IQ8's been in the field? hahaha
@HelmutTschemernjak
@HelmutTschemernjak 2 года назад
I Ben, do you have more information on the Solar stand you have in the video start picture. What kind of model/vendor. Regards from Germany
@benssolarandbattery
@benssolarandbattery 2 года назад
Hi Helmut, this is the Sunmodo Sunturf system. Thanks for watching!
@HelmutTschemernjak
@HelmutTschemernjak 2 года назад
Hi Ben, thank you so much. Have a good weekend.
@kinosi
@kinosi 2 года назад
Do Enphase microinverters work without Envoy and Q Relay? Thank you
@benssolarandbattery
@benssolarandbattery 2 года назад
I've never used the Q relay, so I'd assume that's not for the US. They will work without an envoy here with a standard grid profile and no monitoring.
@kinosi
@kinosi 2 года назад
@@benssolarandbattery Thanks for answering. I was thinking about buying a Enphase microinverter but after contacting with Enphase I will choose another mark. They told me it is necesary to use the three devices together (microinverter, QRelay and Envoy) otherwise it may not work. Very expensive for a basic intallation.
@benssolarandbattery
@benssolarandbattery 2 года назад
@@kinosi what grid power do you have there?
@kinosi
@kinosi 2 года назад
@@benssolarandbatteryI'm from Spain, we have 230V here.
@Repsol1krr
@Repsol1krr 2 года назад
Solark is the best by far 🤙
@benssolarandbattery
@benssolarandbattery Год назад
They do different things well.
@pvon128
@pvon128 3 года назад
Thanks for the view. I see a Solar Edge and Sol Ark inverter. Where are you using the microinverters? How so you choose between a IQ7 and IQ 7+
@benssolarandbattery
@benssolarandbattery 3 года назад
We use microinverters on most installs these days. We use IQ7+ for the 350-400w panels and IQ7A for anything bigger. My Solaredge was installed when Solaredge was reliable. They aren't reliable anymore unfortunately but mine is still kicking.
@strykerace
@strykerace 3 года назад
what was the nature of the issue that made it out of warranty?
@benssolarandbattery
@benssolarandbattery 3 года назад
Grid surge took out 29/30 of the micros. If they hadn't all gone out at the same exact time, I'm sure they would have warrantied them.
@strykerace
@strykerace 3 года назад
@@benssolarandbattery seems fishy that they can opt out of warranty when something breaks during use.
@benssolarandbattery
@benssolarandbattery 3 года назад
@@strykerace unfortunately it is in their warranty documents under section 8. (c).
@TurreTuntematon
@TurreTuntematon 2 года назад
@@strykerace Lol. No electronic device is warranted if the current is not what it’s supposed to be. Hook your TV to a high voltage outlet and see what happens.
@FraLin
@FraLin Год назад
you should find somebody with an electronic knowledge to explain it. I see microprocessorsvand condensers but no semiconductors like MOSFET or diodes.
@fly4fun24
@fly4fun24 Год назад
they claim it is 25Y warranty
@benssolarandbattery
@benssolarandbattery Год назад
They do, but not if there's a grid surge unfortunately.
@gb6041
@gb6041 7 месяцев назад
No matter what, enphase is too expensive
@surenbono6063
@surenbono6063 2 года назад
..they should somehow add a fan with air in/out air valve somewhat waterproofing it..that will significantly prolong it's life..also a surge protection replaceable fuse
@benssolarandbattery
@benssolarandbattery 2 года назад
Surge protection with a replaceable fuse would be great but a fan would be detrimental based on bearing life and dust/dirt.
@surenbono6063
@surenbono6063 2 года назад
@@benssolarandbattery ...it should be able to be lubed or replaced as well.. either as a blow out or intake fans where the air valve keeps it waterproof..or the internal part are thin layered with waterproofing with something like nail polish or similar..
@rickgagne3996
@rickgagne3996 Год назад
They make a nice product, but if it fails there's no customer support. They will tell you that it failed due to the grid or you "misused it". They never gave me a response as to what is considered misuse. They will talk to you once every 3 days so plan on it taking a while.
@benssolarandbattery
@benssolarandbattery Год назад
I've only had them give me issues when it was clear that the system got hit by a surge and almost all of the inverters failed. Otherwise, they're great.
@____________________________.x
@____________________________.x 2 года назад
That asic is huge? This is just a conversion circuit, why does it need all that I/O, there’s nothing much to monitor?
@benssolarandbattery
@benssolarandbattery 2 года назад
I don't know much about circuit boards, but it is a small grid tie inverter packed in there.
@wva5089
@wva5089 2 года назад
We should send one of these to mr bigclive
@RetroElectric
@RetroElectric 2 года назад
👍
@edwardstanley2195
@edwardstanley2195 2 года назад
The surge protection did what it was supposed to do.
@njphil1279
@njphil1279 2 года назад
It'd definitely a warranty claim
@benssolarandbattery
@benssolarandbattery 2 года назад
According to Enphase, it wasn't. I read the fine print on the warranty and they can deny it for anything that they think is a power surge. Trust me, I tried!
@DallasAya
@DallasAya 2 года назад
Hook it up to the solar backwards and wait for the sun to come up and the capicators will explode
@wiggyb854
@wiggyb854 Год назад
Used a pair of pliers for a hammer when there was a hammer right next to him, that’s when I closed the video!
@benssolarandbattery
@benssolarandbattery Год назад
You've never met an electrician, have you...
@wiggyb854
@wiggyb854 Год назад
@@benssolarandbattery actually my father was one and he did it to 🤣
@rajeshraju2364
@rajeshraju2364 6 месяцев назад
ഉള്ള സ്ട്രിങ് ഇൻവെർട്ടറിനെ നാനോ ടെക്നോളജി ഉപയോഗിച്ച് ചെറുതാക്കി.... അത്രേം ഉള്ളു... Dc കേബിളിന്റ നീളം കുറച്ചു കാശു കൂട്ടി.. അത്രേം ഉള്ളു 😂
Далее
Installing Enphase Micro Inverters
9:43
Просмотров 56 тыс.
Курск - врата Рая / Новости / Шпак
1:14:35
Vladimir Putinin Bakıda rəsmi qarşılanma mərasimi
13:06
New Enphase IQ8 MicroInverters
6:55
Просмотров 18 тыс.
Enphase Solar Install Kensington
12:30
Просмотров 2,1 тыс.
Enphase Review - Are Enphase microinverters any good?
12:53
Changing An Enphase M-215 Inverter
11:13
Просмотров 843
Enphase Vs SolarEdge
11:05
Просмотров 42 тыс.
Failed Enecsys 360w solar microinverter teardown (018)
15:54